SAP ABAP Class CL_SATC_AC__UI_VDCT_FILTER_STD (Standard skin: Filter)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-DWB-TOO-ATF (Application Component) ABAP Test Frameworks ( ATC, CheckMan, Code Inspector)
     SATC_ABAP_CHECK__UI (Package) INTERNAL: - *NO* REUSE - UI "CheckMan" style
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  IF_SATC_AC__UI_VDCT_FILTER Selection criteria on 'Findings' in SAP GUI 20081114
Properties
Class CL_SATC_AC__UI_VDCT_FILTER_STD  
Short Description Standard skin: Filter    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package SATC_ABAP_CHECK__UI   INTERNAL: - *NO* REUSE - UI "CheckMan" style 
Created 20081114   SAP 
Last change 20140121   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 IF_SATC_AC__UI_VDCT_FILTER Forward declaration interface (INTERFACE i DEFINITION DEF...  Forward declaration interface (INTERFACE i DEFINITION DEF...
Interfaces
# Interface Abstract Final Description Created on
1 IF_SATC_AC__UI_VDCT_FILTER Selection criteria on 'Findings' in SAP GUI 20081114
Friends
Class CL_SATC_AC__UI_VDCT_FILTER_STD has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 C_ID Constant Private See coding Ids for mapping ranges vs domain restriction 20081114
2 FG_META_DATA Static Attribute Private Type reference (TYPE) IF_SATC_AC__UI_VDCT_FILTER=>TY_T_META_DATA Descritions of relation between domain and criteria 20081114
3 F_CRITERIA Instance attribute Private Type reference (TYPE) TY_S_CRITERIA 20081114
4 F_CURRENT_HASH Instance attribute Private Type reference (TYPE) I 20120521
5 F_EXCLUDE_XMPT Instance attribute Private Type reference (TYPE) IF_SATC_AC__UI_VDCT_FILTER=>TY_D_OPTION IF_SATC_AC__UI_VDCT_FILTER=>C_XMPT_RESTRICTION-ACTIVE Exclude verdicts on exempted objects 20081114
6 F_ID Instance attribute Private Type reference (TYPE) SATC_D_ID Unique ID - hex 16 - in raw format 20081114
7 F_SETTINGS_ACCESS Instance attribute Private Object reference (TYPE REF TO) CL_SATC_AC_UI_SETTINGS_DIALOG 20120403
Methods
# Method Level Visibility Method type Description Created on
1 CONSTRUCTOR Instance method Public Constructor 20091218
2 __CONVERT_DOMAIN_TO_RANGE Instance method Private Method Convert Domain to Range Representation 20081114
3 __CONVERT_RANGE_TO_DOMAIN Instance method Private Method Convert Range to Domain Representation 20081114
4 __IS_PRIORITY_VALUE_VALID Instance method Private Method 20120305
5 __NOTIFY_CRITERIA_CHANGED Instance method Private Method 20120521
Events
Class CL_SATC_AC__UI_VDCT_FILTER_STD has no event.
Types
# Type Visibility Typing Associated Type Description Created on Type Source
1 TY_S_CRITERIA Public See coding 20081114 begin of ty_S_Criteria, package_Range type range of devclass, appl_Comp_Range type range of ufps_Posid, dlv_Unit_Range type range of dlvunit, obj_Type_Range type range of trobjtype, obj_Name_Range type range of sobj_Name , module_Range type range of satc_D_Id, msg_Key_Range type range of sychar12, q_Std_Range type range of sychar02, prio_Range type range of int1, resp1_Range type range of syuname, checksum_Range type range of satc_D_Ui_Checksum, completion_State type range of satc_D_Ac_Compl_State, end of ty_S_Criteria
Method Signatures

Method CONSTRUCTOR Signature

Method CONSTRUCTOR on class CL_SATC_AC__UI_VDCT_FILTER_STD has no parameter.
Method CONSTRUCTOR on class CL_SATC_AC__UI_VDCT_FILTER_STD has no exception.

Method __CONVERT_DOMAIN_TO_RANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_RANGE_OPTION Call by reference Type reference (TYPE) SYCHAR02 'EQ', 'CP', ..... 20081114
2 Exporting E_RANGE_SIGN Call by reference Type reference (TYPE) SYCHAR01 'I' or 'E' 20081114
3 Importing I_DOMAIN_OPTION Call by reference Type reference (TYPE) SYCHAR02 'EQ', 'NE', 'CP', 'NP', ... 20081114

Method __CONVERT_DOMAIN_TO_RANGE on class CL_SATC_AC__UI_VDCT_FILTER_STD has no exception.

Method __CONVERT_RANGE_TO_DOMAIN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_DOMAIN_OPTION Call by reference Type reference (TYPE) SYCHAR02 'EQ', 'NE', 'CP', 'NP', .... 20081114
2 Importing I_RANGE_OPTION Call by reference Type reference (TYPE) SYCHAR02 'EQ', 'CP', ..... 20081114
3 Importing I_RANGE_SIGN Call by reference Type reference (TYPE) SYCHAR01 'I' or 'E' 20081114

Method __CONVERT_RANGE_TO_DOMAIN on class CL_SATC_AC__UI_VDCT_FILTER_STD has no exception.

Method __IS_PRIORITY_VALUE_VALID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PRIORITY Call by reference Type reference (TYPE) SATC_AC_UI_FILTER_VALUE 20120305
2 Returning RESULT Value transfer Type reference (TYPE) ABAP_BOOL 20120305

Method __IS_PRIORITY_VALUE_VALID on class CL_SATC_AC__UI_VDCT_FILTER_STD has no exception.

Method __NOTIFY_CRITERIA_CHANGED Signature

Method __NOTIFY_CRITERIA_CHANGED on class CL_SATC_AC__UI_VDCT_FILTER_STD has no parameter.
Method __NOTIFY_CRITERIA_CHANGED on class CL_SATC_AC__UI_VDCT_FILTER_STD has no exception.
History
Last changed by/on SAP  20140121 
SAP Release Created in 720