SAP ABAP Class CL_RMXM_ROM_MR_PHASE (RMXM-TRF: Master Recipe Phase)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷ PLM-RM-TRS (Application Component) Transformation
⤷ RMXMTRF (Package) Main Package - Transformation: Tools
⤷ PLM-RM-TRS (Application Component) Transformation
⤷ RMXMTRF (Package) Main Package - Transformation: Tools
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_RMXM_ROM_MR_OBJECT | RMXM-TRF: Master Recipe ROM | 20030408 |
Properties
Class | CL_RMXM_ROM_MR_PHASE | |
Short Description | RMXM-TRF: Master Recipe Phase | |
Super Class | CL_RMXM_ROM_MR_OBJECT | RMXM-TRF: Master Recipe ROM |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | RMXMTRF | Main Package - Transformation: Tools |
Created | 20030408 | SAP |
Last change | 20110908 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_RMXM_ROM_MR_PHASE has no forward declaration.
Interfaces
Class CL_RMXM_ROM_MR_PHASE has no interface implemented.
Friends
Class CL_RMXM_ROM_MR_PHASE has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | C_OPR_NUM_MAX | Constant | Public | Type reference (TYPE) | NUM4 | 9999 | 4-Digit Number | 20030527 | |
2 | C_OPR_NUM_MIN | Constant | Public | Type reference (TYPE) | NUM4 | 0000 | 4-Digit Number | 20030527 | |
3 | MO_GR_OBJ | Instance attribute | Protected | Object reference (TYPE REF TO) | IF_RMXM_ROM_OBJECT | Common Interface for the ROM | 20030408 | ||
4 | MS_PHASE | Instance attribute | Protected | Type reference (TYPE) | RMXMS_PLPO | RMXM-TRF: Task List Operation | 20030408 | ||
5 | M_FLG_FIRST | Instance attribute | Protected | Type reference (TYPE) | FLAG | General Indicator | 20030828 | ||
6 | M_PI_NUM | Instance attribute | Protected | Type reference (TYPE) | R_FTNR | Line Number of Process Instruction | 20030527 | ||
7 | M_PI_NUM_INC | Static Attribute | Protected | Type reference (TYPE) | NUM4 | 4-Digit Number | 20030527 | ||
8 | M_QM_INC | Static Attribute | Protected | Type reference (TYPE) | QMERKNRP | Inspection Characteristic Number | 20030510 | ||
9 | M_QM_NUM | Instance attribute | Protected | Type reference (TYPE) | QMERKNRP | Inspection Characteristic Number | 20030510 | ||
10 | M_SUBOPR_INC | Static Attribute | Protected | Type reference (TYPE) | DEL_VORNR | Increment for automatic operation/activity numbering | 20030510 | ||
11 | M_SUBOPR_NUM | Instance attribute | Protected | Type reference (TYPE) | NUM4 | 4-Digit Number | 20030510 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CONSTRUCTOR | Instance method | Public | Constructor | CONSTRUCTOR | 20030425 |
2 | GET_ATTRIBUTES | Instance method | Public | Method | Reads the Attribute Values | 20030408 |
3 | GET_NEXT_PI_NUM | Instance method | Public | Method | Call Next Semantic Key of Process Instruction | 20030527 |
4 | GET_NEXT_QM_NUM | Instance method | Public | Method | Call Next QM Number | 20030510 |
5 | GET_NEXT_SUBOPR_NUM | Instance method | Public | Method | Call Next Suboperation Number | 20030508 |
6 | GET_PROCESS_PARAMETER | Instance method | Public | Method | Get the Process Parameters of the Process Operation | 20030915 |
7 | INIT_PI_SEM_KEY | Instance method | Public | Method | Initialize Key Fields of Process Instruction | 20030916 |
8 | SET_ATTRIBUTES | Instance method | Public | Method | Assigns Values to the Attributes | 20030408 |
9 | SET_PI_INCREMENT | Static method | Public | Method | Set Next Process Instruction Number | 20030527 |
10 | SET_QM_INCREMENT | Static method | Public | Method | Set Increment for Automatic QM Numbering | 20030510 |
11 | SET_SUBOPR_INCREMENT | Static method | Public | Method | Set Increment for Automatic Operation/Phase Numbering | 20030508 |
12 | TRANSFORM_PP_TO_PI | Instance method | Public | Method | Transform Process Parameters for Process Instruction | 20030915 |
Events
Class CL_RMXM_ROM_MR_PHASE has no event.
Types
Class CL_RMXM_ROM_MR_PHASE has no local type.
Method Signatures
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IT_ALLOWED_CHILD_OBJ_TYP | Call by reference | Type reference (TYPE) | RMXMTY_ROM_ALLOWED_CHILD_TYP | Erlaubte Objekttypen der Kinder | 20030425 | ||
2 | Importing | I_OBJ_TYP | Call by reference | Type reference (TYPE) | RMXME_ROM_OBJ_TYP | Objekttyp des Rezeptobjektmodells | 20030425 |
Method CONSTRUCTOR on class CL_RMXM_ROM_MR_PHASE has no exception.
Method GET_ATTRIBUTES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EO_GR_OBJ | Call by reference | Object reference (TYPE REF TO) | IF_RMXM_ROM_OBJECT | Gemeinsame Schnittstelle für das ROM | 20030408 | ||
2 | Exporting | ES_PHASE | Call by reference | Type reference (TYPE) | RMXMS_PLPO | RMXM-TRF : Plan-Vorgang | 20030408 |
Method GET_ATTRIBUTES on class CL_RMXM_ROM_MR_PHASE has no exception.
Method GET_NEXT_PI_NUM Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | E_PI_NUM | Value transfer | Type reference (TYPE) | R_FTNR | Zeilennummer der Prozeßvorgabe | 20030527 |
Method GET_NEXT_PI_NUM on class CL_RMXM_ROM_MR_PHASE has no exception.
Method GET_NEXT_QM_NUM Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | E_QM_NUM | Value transfer | Type reference (TYPE) | QMERKNRP | Prüfmerkmalsnummer | 20030510 |
Method GET_NEXT_QM_NUM on class CL_RMXM_ROM_MR_PHASE has no exception.
Method GET_NEXT_SUBOPR_NUM Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | E_SUBOPR_NUM | Value transfer | Type reference (TYPE) | NUM4 | Nummer 4 Stellig | 20030510 |
Method GET_NEXT_SUBOPR_NUM on class CL_RMXM_ROM_MR_PHASE has no exception.
Method GET_PROCESS_PARAMETER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | ET_PROCPARA | Value transfer | Type reference (TYPE) | RMXMTY_ROM_CHILD | Kinder eines ROM Knotens | 20030915 |
Method GET_PROCESS_PARAMETER on class CL_RMXM_ROM_MR_PHASE has no exception.
Method INIT_PI_SEM_KEY Signature
Method INIT_PI_SEM_KEY on class CL_RMXM_ROM_MR_PHASE has no parameter.
Method INIT_PI_SEM_KEY on class CL_RMXM_ROM_MR_PHASE has no exception.
Method SET_ATTRIBUTES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_GR_OBJ | Call by reference | Object reference (TYPE REF TO) | IF_RMXM_ROM_OBJECT | Gemeinsame Schnittstelle für das ROM | 20030408 | ||
2 | Importing | IS_PHASE | Call by reference | Type reference (TYPE) | RMXMS_PLPO | RMXM-TRF : Plan-Vorgang | 20030408 |
Method SET_ATTRIBUTES on class CL_RMXM_ROM_MR_PHASE has no exception.
Method SET_PI_INCREMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_PI_NUM_INC | Call by reference | Type reference (TYPE) | FTNR_INC | Schrittweite für automatische Prozeßvorgabenummerierung | 20030527 |
Method SET_PI_INCREMENT on class CL_RMXM_ROM_MR_PHASE has no exception.
Method SET_QM_INCREMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_QM_INC | Call by reference | Type reference (TYPE) | QMERKNRP | Prüfmerkmalsnummer | 20030510 |
Method SET_QM_INCREMENT on class CL_RMXM_ROM_MR_PHASE has no exception.
Method SET_SUBOPR_INCREMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_SUBOPR_INC | Call by reference | Type reference (TYPE) | DEL_VORNR | Schrittweite automatische Vorgangsnumerierung | 20030510 |
Method SET_SUBOPR_INCREMENT on class CL_RMXM_ROM_MR_PHASE has no exception.
Method TRANSFORM_PP_TO_PI Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_MSG | Call by reference | Type reference (TYPE) | RMXMTY_MESSAGES | RMXM: Nachrichtentabelle | 20030915 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20030915 |
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 471 |