SAP ABAP Class CL_PPEUIACT_CNTL (Screen Controller)
Hierarchy
EA-IPPE (Software Component) SAP iPPE
   AP-PPE (Application Component) Integrated Product and Process Engineering
     CPPEACT (Package) ACT-Specific iPPE Objects
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CL_PPEUIENG_CNTL Controller Class for all Screens 20000630
2 Interface implementation (CLASS c. INTERFACES i_ref)  IF_PPEGUIREL_CNTL Create/Delete iPPE Relationships 20020128
3 Interface implementation (CLASS c. INTERFACES i_ref)  IF_PPENIENG_CNTL Interface for application objects for network graphic 20011121
Properties
Class CL_PPEUIACT_CNTL  
Short Description Screen Controller    
Super Class CL_PPEUIENG_CNTL Controller Class for all Screens 
Instantiability of a Class 0  Private 
Final    
General Data
Message Class    
Program status     
Category 0   
Package CPPEACT   ACT-Specific iPPE Objects 
Created 20000630   SAP 
Last change 20050301   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PPERP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 PPET Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 PPET2 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
# Interface Abstract Final Description Created on
1 IF_PPEGUIREL_CNTL Create/Delete iPPE Relationships 20020128
2 IF_PPENIENG_CNTL Interface for application objects for network graphic 20011121
Friends
Class CL_PPEUIACT_CNTL has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 ACTHD_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Routing header data was read 20021022
2 ACTOPR_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Operation Data Read 20031120
3 ACT_ARC_MODE Static Attribute Public Type reference (TYPE) PPE_ARC_MODE Archiving Status 20050222
4 ACT_FIRST_SCREEN Static Attribute Public Type reference (TYPE) PPE_TS_SCRNAME Activity Detail Screen: First Screen 20021031
5 ACT_GREYFLAG Static Attribute Public Type reference (TYPE) XFELD Greyflag Buffer 20010116
6 ACT_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Activity data has been read 20001204
7 ASS_JUMP_FLAG Static Attribute Public Type reference (TYPE) XFELD Is set when assignment list is to be started 20010427
8 CMP_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Components Loaded 20001205
9 COLOR_BACKGROUND Constant Public Type reference (TYPE) CHAR4 'C000' Color of Background 20020118
10 COLOR_BLUE Constant Public Type reference (TYPE) CHAR4 'C100' Color Blue 20020118
11 COLOR_BLUE_INTENSIV Constant Public Type reference (TYPE) CHAR4 'C110' Color Intensive Blue 20020118
12 COLOR_WHITE Constant Public Type reference (TYPE) CHAR4 'C200' Color White 20020118
13 COMP_AENNR_NAME Static Attribute Public Type reference (TYPE) CHAR10 General Component Name of the Change Number 20020918
14 CURRENT_PLANTYPE Static Attribute Public Type reference (TYPE) PPE_PLANTYPE Current Task List Type 20010710
15 CURRENT_PLANTYPE_ASSIGNLIST Static Attribute Public Type reference (TYPE) PPE_PLANTYPE Current Task List Type: Assignment List 20010807
16 CURRENT_PRODUCTIONVERS Static Attribute Public Type reference (TYPE) PPET2_PRODUCTIONVERSION Current Production Version 20010427
17 CURR_EXCL_ACT_TAB Static Attribute Public Type reference (TYPE) PPET2_FIELD_SEL_TAB Current Field Exclusion Table: Activity 20021029
18 CURR_EXCL_CAPA_TAB Static Attribute Public Type reference (TYPE) PPET2_FIELD_SEL_TAB Current Field Exclusion Table: Capacity Requirements 20021025
19 CURR_EXCL_COMP_TAB Static Attribute Public Type reference (TYPE) PPET2_FIELD_SEL_TAB Current Field Exclusion Table: Assignment 20021025
20 CURR_EXCL_MODE_TAB Static Attribute Public Type reference (TYPE) PPET2_FIELD_SEL_TAB Current Field Exclusion Table: Mode 20021025
21 CURR_EXCL_OPR_TAB Static Attribute Public Type reference (TYPE) PPET2_FIELD_SEL_TAB Current Field Exclusion Table: Operation 20031120
22 DD07T_ACTTYPE Static Attribute Private Type reference (TYPE) PPET2_DD07V_TAB DD: Texts for Domain Fixed Values (Language-Dependent) 20010409
23 DD07T_MATCOFLG Static Attribute Private Type reference (TYPE) PPET2_DD07V_TAB DD: Texts for Domain Fixed Values (Language-Dependent) 20010423
24 DD07T_MATCOFLG_RED Static Attribute Private Type reference (TYPE) PPET2_DD07V_TAB DD: Texts f. Domain Fxd Values (Language-Dependent) for Line 20010807
25 DD07T_RESTYPE Static Attribute Private Type reference (TYPE) PPET2_DD07V_TAB DD: Texts for Domain Fixed Values (Language-Dependent) 20011221
26 DD07T_SEQTYPE Static Attribute Private Type reference (TYPE) PPET2_DD07V_TAB DD: Texts for Domain Fixed Values (Language-Dependent) 20010409
27 FIELD_EXCL_ACT_TAB Static Attribute Private Type reference (TYPE) PPET2_FIELD_EXCL_TAB Table of fields that cannot be displayed: Activity 20021029
28 FIELD_EXCL_CAPA_TAB Static Attribute Private Type reference (TYPE) PPET2_FIELD_EXCL_TAB Table of fields that cannot be displayed: Capacity Reqmts. 20021025
29 FIELD_EXCL_COMP_TAB Static Attribute Private Type reference (TYPE) PPET2_FIELD_EXCL_TAB Table of fields that cannot be displayed: Assignment 20021025
30 FIELD_EXCL_MODE_TAB Static Attribute Private Type reference (TYPE) PPET2_FIELD_EXCL_TAB Table of fields that cannot be displayed: Mode 20021025
31 FIELD_EXCL_OPR_TAB Static Attribute Private Type reference (TYPE) PPET2_FIELD_EXCL_TAB Table of fields that cannot be displayed: Operation 20031120
32 ICON_DOCUMENT Constant Public Type reference (TYPE) TV_IMAGE '@AR@' Icon for Document 20020117
33 ICON_ERROR_SMALL Constant Public Type reference (TYPE) TV_IMAGE '@8O@' Small Icon Error 20020117
34 ICON_GREEN_LED Constant Public Type reference (TYPE) TV_IMAGE '@5B@' Icon Green LED 20020117
35 ICON_GREEN_LIGHT Constant Public Type reference (TYPE) TV_IMAGE '@08@' Icon Green Light 20020117
36 ICON_INACTIVE_LED Constant Public Type reference (TYPE) TV_IMAGE '@BZ@' Icon: Inactive LED 20020117
37 ICON_PARA_END Constant Public Type reference (TYPE) TV_IMAGE '@M2@' Icon: End Branch 20020117
38 ICON_PARA_START Constant Public Type reference (TYPE) TV_IMAGE '@5O@' Icon: Start Branch 20020117
39 ICON_RED_LED Constant Public Type reference (TYPE) TV_IMAGE '@5C@' Icon: Red LED 20020117
40 ICON_RED_LIGHT Constant Public Type reference (TYPE) TV_IMAGE '@0A@' Icon: Red Light 20020117
41 ICON_SEQ_END Constant Public Type reference (TYPE) TV_IMAGE '@HF@' Icon: End of Sequence 20020117
42 ICON_SEQ_NORMAL Constant Public Type reference (TYPE) TV_IMAGE '@0H@' Icon: Part of a Sequence 20020117
43 ICON_SEQ_START Constant Public Type reference (TYPE) TV_IMAGE '@HG@' Icon: Start of Sequence 20020117
44 ICON_SPACY Constant Public Type reference (TYPE) TV_IMAGE '@ @' Icon: Empty 20020117
45 ICON_WARNING Constant Public Type reference (TYPE) TV_IMAGE '@AH@' Icon: Warning 20020117
46 ICON_WARNING_SMALL Constant Public Type reference (TYPE) TV_IMAGE '@8R@' Small Icon: Warning 20020117
47 ICON_YELLOW_LED Constant Public Type reference (TYPE) TV_IMAGE '@BD@' Icon: Yellow LED 20020117
48 ICON_YELLOW_LIGHT Constant Public Type reference (TYPE) TV_IMAGE '@09@' Icon: Yellow Light 20020117
49 INSTANCE Static Attribute Private Object reference (TYPE REF TO) CL_PPEUIACT_CNTL Screen Controller 20000630
50 KLART Static Attribute Public Type reference (TYPE) PPE_KLASSENART Class Type of Current Node 20001204
51 KLASSE Static Attribute Public Type reference (TYPE) KLASSE_D Class of Current Node 20001204
52 LOCID_SIZE Static Attribute Public Type reference (TYPE) I Number of Characters for Location Type 20020116
53 LOCID_TEXT Static Attribute Public Type reference (TYPE) TEXT40 Description of Plant/Location 20041105
54 MATID_SIZE Static Attribute Public Type reference (TYPE) I Number of Characters for Material 20020117
55 MATID_TEXT Static Attribute Public Type reference (TYPE) TEXT40 Product/Material Description 20041105
56 MOD_FIRST_SCREEN Static Attribute Public Type reference (TYPE) PPE_TS_SCRNAME Mode Details Screen: First Screen 20010423
57 MOD_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Modes Loaded 20001209
58 MOD_RESTYPE_SEL_TAB Static Attribute Private Type reference (TYPE) PPET2_RES_TYPE_SEL_TAB Range Table for Current Resource Types 20010813
59 MOD_RES_TYPE_TAB Static Attribute Private Type reference (TYPE) PPET2_RES_TYPE_TAB Resources and Resource Types of an Activity 20010813
60 PLANTYPES_TAB Static Attribute Private Type reference (TYPE) PPET2_PLANTYPES_TAB Table of Different Routing Types 20020206
61 PNACTHD_DATA Static Attribute Public Type reference (TYPE) PPET2_PNACTHD_LI Additional Data for Current Routing Header 20021022
62 PNACTOPR_DATA Static Attribute Public Type reference (TYPE) PPET2_PNACTOPR_LI Additional Data for Current Operation 20031120
63 PNACT_DATA Static Attribute Public Type reference (TYPE) PPET2_PNACT_LI Additional Data for Current Activity 20001204
64 PNTYPE_ICON_ACT_TAB Static Attribute Public Type reference (TYPE) PPET2_PNTYPE_LARGE_ICON_TAB Interface Elements for ACT Node Types 20010223
65 PNTYPE_ICON_CMP_TAB Static Attribute Public Type reference (TYPE) PPET2_PNTYPE_LARGE_ICON_TAB Interface Elements for CMP Node Types 20010223
66 PRODV_TEXT Static Attribute Public Type reference (TYPE) TEXT40 Production Version Description 20041105
67 PVB_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Indicators have been read for current supply area assgts 20010718
68 PVTYPE_ICON_CMP_TAB Static Attribute Public Type reference (TYPE) PPET2_PVTYPE_LARGE_ICON_TAB Interface Elements for CMP Variant Types 20010223
69 SEQ_H_CURRENT_MODE Static Attribute Public Type reference (TYPE) CHAR1 Type of Current Sequence Screen 20010214
70 SEQ_H_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Sequence Relationship Read for Hierarchy 20010126
71 SEQ_ICON_TAB Static Attribute Public Type reference (TYPE) PPET2_LARGE_ICON_SEQ_TAB Table of Icons for Sequence Elements 20010223
72 SEQ_READ_FLAG Static Attribute Public Type reference (TYPE) XFELD Sequence Relationship Read 20010110
73 TA_CURRENT_AENNR Static Attribute Public Type reference (TYPE) PVS_AENNR Change Status Currently Being Processed in Time Analysis 20010126
74 TA_CURRENT_PALTID Static Attribute Public Type reference (TYPE) PPET_PALTID_LI Mode Currently Being Processed in Time Analysis 20010126
75 TA_CURRENT_PNODID Static Attribute Public Type reference (TYPE) PPET_PNODID_LI Node Currently Being Processed in Time Analysis 20010126
76 TA_CURRENT_TAIDSAP Static Attribute Public Type reference (TYPE) PPE_TAIDSAP Currently Selected Key for a Time Analysis 20010125
77 VERID_SIZE Static Attribute Public Type reference (TYPE) I Number of Characters in Production Version Name 20040902
Methods
# Method Level Visibility Method type Description Created on
1 CHECK_RESSOUCE Static method Public Method Checks Resources and Their Classes, and Gets GUID 20001016
2 CLASS_CONSTRUCTOR Static method Public Constructor CLASS_CONSTRUCTOR 20010227
3 CREATE_PNACT Static method Public Method Creates New Activity Node 20001208
4 CTMENU_CHANGE_OBJTYPE Static method Public Method Change the Object Types of Grouping Nodes 20010425
5 CTMENU_SEQ_ON_OBJECT_DELETE Static method Public Method Delete the Sequence Relationships for an Object 20010424
6 GET_ACTIVITY_DATA Static method Public Method Gets Information about an Activity Node 20001129
7 GET_COMPONENT_DATA Static method Public Method Gets Information about a Component 20001205
8 GET_DOMAINNAMES_TAB Static method Public Method Read the Domain Names of an Object Type 20010423
9 GET_INSTANCE Static method Public Method Wrap Constructor, Call REGISTER_COMPONENT 20000630
10 GET_MOD_RESTYPE_SEL_TAB Static method Public Method Read the Private Table 'MOD_RESTYPE_SEL_TAB' 20010813
11 GET_MOD_RES_TYPE Static method Public Method Read the Type of a Current Resource 20010813
12 GET_PLANTYPE_DESC Static method Public Method Read the description of the routing type 20020206
13 GET_RESOURCE_DATA Static method Public Method Gets all Data for a Resource Node 20001017
14 GET_RESOURCE_GUID Static method Public Method Determines GUID of a Resource 20001008
15 KN_STATUS_SET Static method Public Method Set Output Status of Object Dependency 20021030
16 NET_GET_ACTIVITY_TYPE Static method Public Method Read the Activity Types for the Network Graphic 20010409
17 NET_GET_SEQUENCE_TYPE Static method Public Method Read the Sequence Types for the Network Graphic 20010409
18 NET_PRSEQ_CREATE Static method Public Method Create Sequence Relationship 20010409
19 NET_SET_INSTANCE Static method Public Method Give the instance to the network graphic 20011121
20 NET_START_NETWORK Static method Public Method Start the Network Graphic 20010409
21 READ_COMP_NAME Static method Public Method Read the Key for a Component by Name 20001205
22 READ_PVB_ACT Static method Public Method Read the Supply Area Assignments for an Activity 20010718
23 READ_PXTYPE_DESC Static method Public Method Gets the Description of a Customizing Object Type 20001210
24 READ_SINGLE_ACT Static method Public Method Read the Activity Data for an Activity 20001204
25 REFRESH_ALL Static method Public Method Create Initial Status 20001204
26 REL_SET_INSTANCE Static method Public Method Give the instance to the network graphic 20020128
27 SEL_PAMODD_COPYMODE Static method Public Method Inquiry: Which Mode Attributes Are to Be Copied 20010119
28 SEL_RELMDL_TYPES Static method Public Method Selection of MDL Customizing Types for Relationships 20001210
29 SEL_RELPR_TYPES Static method Public Method Selection of PR Customizing Types for Relationships 20001210
30 SEL_TAUSE Static method Public Method Which Data from the Time Analysis Is to Be Transferred? 20001210
31 SEQ_INSERT_OBJECT Static method Public Method Insert an Object into a Sequence Before Another 20010126
32 SET_ACT_STRUCT_TYPES Static method Private Method Set Interface Customizing Types and Tables 20010223
33 SET_EXCL_FIELD_TABS Static method Private Method Set Screen Field Tables to be Hidden 20021025
34 SET_MOD_RESTYPE_SEL_TAB Static method Public Method Set the Private Table 'MOD_RESTYPE_SEL_TAB' 20010813
35 SET_MOD_RES_TYPE_TAB Static method Public Method Set the Private Table 'MOD_RES_TYPE_TAB' 20010813
36 SET_PRODUCTIONVERSION Static method Public Method Set the Production Version 20010427
37 SET_SEQUENCE Static method Public Method Gets Sequence Relationship for a Node 20001204
38 TIMEANALYZE_ADJUST_DATA Static method Public Method Adjust the Time Analysis Data in the Mode Fields 20010131
39 TIMEANALYZE_COPY_DATA Static method Public Method Copy the Time Analysis Data to the Mode Fields 20010131
40 TIMEANALYZE_EXIT Static method Public Event handling method Time Analysis Completed for 'Exit' Event 20001025
41 TIMEANALYZE_GET_VWEA Static method Public Method Determine the SVDT for Transfer from Time Analysis 20010111
42 UPDATE_PAMODD_AFTER_SAVE Static method Private Event handling method Update Temp_PAMODD_Clipboard After Saving 20010111
Events
Class CL_PPEUIACT_CNTL has no event.
Types
Class CL_PPEUIACT_CNTL has no local type.
Method Signatures

Method CHECK_RESSOUCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_LOCID Call by reference Type reference (TYPE) PPE_LOCID Plant 20001017
2 Changing CH_RES_NAME Call by reference Type reference (TYPE) PVS_PNODE Resource Name 20001017
3 Exporting EX_CLINT Call by reference Type reference (TYPE) PPENV_CLASS-CLINT Internal Class Assignment 20001016
4 Exporting EX_PNGUID Call by reference Type reference (TYPE) PVS_PNGUID GUID for the Resource 20001016
5 Exporting EX_RESOURCE Call by reference Type reference (TYPE) PPET6_PNRES_LI Attributes of the Resource 20001016
6 Importing IM_CLASS Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Class 20001017
7 Importing IM_KLART Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Class Type 20001017
8 Importing IM_MODUSD Call by reference Type reference (TYPE) C PPET_TRUE Resource for Capacity Planning 20001017
9 Importing IM_PAGUID Call by reference Type reference (TYPE) PVS_GUID GUID for a Mode 20010409

Method CHECK_RESSOUCE on class CL_PPEUIACT_CNTL has no exception.

Method CLASS_CONSTRUCTOR Signature

Method CLASS_CONSTRUCTOR on class CL_PPEUIACT_CNTL has no parameter.
Method CLASS_CONSTRUCTOR on class CL_PPEUIACT_CNTL has no exception.

Method CREATE_PNACT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PNACT Call by reference Type reference (TYPE) PPET2_PNACT_LI Additional Data for Application 20001208
2 Changing CH_PNACTHD Call by reference Type reference (TYPE) PPET2_PNACTHD_LI Datenrucksack Arbeitsplankopf 20021023
3 Changing CH_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Nodes 20001208
4 Changing CH_PNODTX_TAB Call by reference Type reference (TYPE) PPET_PPETX_LI_TAB Corresponding Text Lines 20001208
5 Changing CH_PVBASS_TAB Call by reference Type reference (TYPE) PPET2_PVBASS_LI_TAB Table of Supply Area Assignments 20010718
6 Changing CS_PNACTOPR Call by reference Type reference (TYPE) PPET2_PNACTOPR_LI Datenrucksack Vorgang 20030825
7 Importing IM_NO_EVENT Call by reference Type reference (TYPE) C PPET_FALSE Allow Event 20010727
8 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message-Handler 20040108
# Exception Resumable Description Created on
1 PNACT_CREATE_ERROR Node Could Not Be Created 20001208

Method CTMENU_CHANGE_OBJTYPE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL with Message Handler 20010425
2 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Node in the Sequence 20010425
# Exception Resumable Description Created on
1 ERROR Test 20010426

Method CTMENU_SEQ_ON_OBJECT_DELETE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL with Message Handler 20010424
2 Importing IM_SEQ_OBJECT Call by reference Type reference (TYPE) PPET_PNODID_LI Node in the Sequence 20010424
# Exception Resumable Description Created on
1 ERROR Test 20010426

Method GET_ACTIVITY_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_PNACT Call by reference Type reference (TYPE) PPET2_PNACT_LI Aktivitätsdaten 20040205
2 Exporting EX_ACTTYPE Call by reference Type reference (TYPE) PPE_ACTTYPE iPPE Activity Type 20010126
3 Exporting EX_CLASS Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Node Class 20001129
4 Exporting EX_CMP_FOUND Call by reference Type reference (TYPE) C Component assignments exist 20010808
5 Exporting EX_DESC Call by reference Type reference (TYPE) PVS_DESC Description of iPPE Object Type 20010125
6 Exporting EX_ICON Call by reference Type reference (TYPE) PPE_ICON Node Icon 20001129
7 Exporting EX_KLART Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Node Class Type 20001129
8 Exporting EX_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Routing Type in iPPE Proc.Struct. 20010808
9 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Activity Node 20001129

Method GET_ACTIVITY_DATA on class CL_PPEUIACT_CNTL has no exception.

Method GET_COMPONENT_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CLASS Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Class 20001205
2 Exporting EX_ICON Call by reference Type reference (TYPE) PPE_ICON Icon 20001205
3 Exporting EX_ICON_LARGE Call by reference Type reference (TYPE) PPE_DESC_ICON Icon with Description 20010227
4 Exporting EX_KLART Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Class Type 20001205
5 Exporting EX_PDESC Call by reference Type reference (TYPE) PVS_DESC Description of iPPE Object Type 20001206
6 Exporting EX_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Component Data 20010719
7 Exporting EX_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI Variant Data 20010719
8 Importing IM_GUID Call by reference Type reference (TYPE) PPET_GUID-GUID Internal Identification for PVS Objects 20010719
9 Importing IM_OTYPE Call by reference Type reference (TYPE) PPET_GUID-OTYPE iPPE Object Type 20010719
10 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Component Node 20001205
11 Importing IM_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI Component Variant 20001205

Method GET_COMPONENT_DATA on class CL_PPEUIACT_CNTL has no exception.

Method GET_DOMAINNAMES_TAB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ACTTYPES Call by reference Type reference (TYPE) PPET2_DD07V_TAB Domain Names 20010423
2 Exporting EX_MATCOFLG Call by reference Type reference (TYPE) PPET2_DD07V_TAB Domain Names 20010423
3 Exporting EX_MATCOFLG_RED Call by reference Type reference (TYPE) PPET2_DD07V_TAB Domain Names 20010807
4 Exporting EX_SEQTYPES Call by reference Type reference (TYPE) PPET2_DD07V_TAB Domain Names 20010423

Method GET_DOMAINNAMES_TAB on class CL_PPEUIACT_CNTL has no exception.

Method GET_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_INSTANCE Call by reference Object reference (TYPE REF TO) CL_PPEUIACT_CNTL Screen Controller 20000630

Method GET_INSTANCE on class CL_PPEUIACT_CNTL has no exception.

Method GET_MOD_RESTYPE_SEL_TAB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_MOD_RES_TYPES_SEL_TAB Call by reference Type reference (TYPE) PPET2_RES_TYPE_SEL_TAB Current Resource Types: Range Table 20010813

Method GET_MOD_RESTYPE_SEL_TAB on class CL_PPEUIACT_CNTL has no exception.

Method GET_MOD_RES_TYPE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_RES_TYPE Call by reference Type reference (TYPE) PPET6_PNRESR_LI-TYPE APO Resource Type 20010813
2 Importing IM_RESGUID Call by reference Type reference (TYPE) PPET_GUID-GUID Internal Identification for PVS Objects 20010813

Method GET_MOD_RES_TYPE on class CL_PPEUIACT_CNTL has no exception.

Method GET_PLANTYPE_DESC Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PLANTYPE_DESC Call by reference Type reference (TYPE) PPE_PLANTYPE_DESC Description of Routing Types in the iPPE Process Structure 20020206
2 Importing IM_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Routing Types in the iPPE Process Structure 20020206
# Exception Resumable Description Created on
1 NOTHING_FOUND Routing Type Not Found 20020206

Method GET_RESOURCE_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_DIMENSION Call by reference Type reference (TYPE) PPE_DIMENSION Dimension der Ressource 20031212
2 Exporting EV_DIMENSION_BUCKET Call by reference Type reference (TYPE) PPE_DIMENSION_BUCKET Dimension des Bucketbedarfes 20031216
3 Exporting EX_CAP_FLG Call by reference Type reference (TYPE) XFELD Capacity Planning Indicator for the Resource 20001017
4 Exporting EX_CLASS Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Class 20001017
5 Exporting EX_CLINT Call by reference Type reference (TYPE) PPENV_CLASS-CLINT Internal Class 20001017
6 Exporting EX_DESC Call by reference Type reference (TYPE) PVS_DESC Description of iPPE Object Type 20010124
7 Exporting EX_ICON Call by reference Type reference (TYPE) PPE_ICON Icon for Operating Facility 20001017
8 Exporting EX_KLART Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Class Type 20001017
9 Exporting EX_PNODID_EXT Call by reference Type reference (TYPE) PPET_PNODID_EXT External Identification 20010813
10 Exporting EX_PNTEXT Call by reference Type reference (TYPE) PVS_PNODETX Short Text for Resource 20001017
11 Exporting EX_RES_DESC Call by reference Type reference (TYPE) PPE_RESOURCE_DESC Description of Resource Types 20011227
12 Exporting EX_RES_NAME Call by reference Type reference (TYPE) PVS_PNODE Resource Name 20001017
13 Exporting EX_RES_TYPE Call by reference Type reference (TYPE) PPET6_PNRESR_LI-TYPE Basic Types of Production Resources 20010810
14 Exporting EX_RES_UNIT Call by reference Type reference (TYPE) PPE_UNIT Unit of Measurement for Resource 20001027
15 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_NONE with Message Handler 20001017
16 Importing IM_PNGUID Call by reference Type reference (TYPE) PVS_PNGUID Node GUID 20001017
# Exception Resumable Description Created on
1 VALID_PNODID Invalid Node GUID Was Transferred 20001017

Method GET_RESOURCE_GUID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PNGUID Call by reference Type reference (TYPE) PVS_PNGUID Internal Number of PVS Node 20001008
2 Exporting EX_RES Call by reference Type reference (TYPE) PPET6_PNRES_LI Resource Attributes 20001011
3 Importing IM_CLINT Call by reference Type reference (TYPE) PPENV_CLASS-CLINT Internal Class 20001010
4 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL with Message Handler 20001016
5 Importing IM_RES_NAME Call by reference Type reference (TYPE) PVS_PNODE iPPE Node 20001008
# Exception Resumable Description Created on
1 NO_GUID No GUID Could Be Found 20001008
2 RESOURCE_DOES_NOT_EXISTS Resource Does Not Exist 20001008

Method KN_STATUS_SET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_STATUS_TEXT Call by reference Type reference (TYPE) C Ausgabetext des Status 20021030
2 Importing IM_KNOBJ Call by reference Type reference (TYPE) PPE_KNOBJ Nummer von Objekt mit zugeordneten Wissensbausteinen 20021030
3 Importing IM_TAB Call by reference Type reference (TYPE) KNTAB PPET2_KNOBJ_TAB-MODUS Tabellen-Id des Objekts 20021030
4 Importing IM_WITH_TEXT Call by reference Type reference (TYPE) C PPET_TRUE mit Textausgabe 20021030

Method KN_STATUS_SET on class CL_PPEUIACT_CNTL has no exception.

Method NET_GET_ACTIVITY_TYPE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ACTTYPE Call by reference Type reference (TYPE) C Activity Type as Text 20010409
2 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Nodes 20010409

Method NET_GET_ACTIVITY_TYPE on class CL_PPEUIACT_CNTL has no exception.

Method NET_GET_SEQUENCE_TYPE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_LNKTYPE Call by reference Type reference (TYPE) C Link Mode for Sequence Relationships 20010409
2 Exporting EX_MARKER_END Call by reference Type reference (TYPE) C Relationship End 20010409
3 Exporting EX_MARKER_START Call by reference Type reference (TYPE) C Relationship Start 20010409
4 Exporting EX_SEQTYPE Call by reference Type reference (TYPE) C Sequence Type Relationship 20010409
5 Exporting EX_SEQTYPE_TEXT Call by reference Type reference (TYPE) C Text for Sequence Relationship 20010409
6 Importing IM_PRELID Call by reference Type reference (TYPE) PPET_PRELID_LI Sequence Relatshp 20010409

Method NET_GET_SEQUENCE_TYPE on class CL_PPEUIACT_CNTL has no exception.

Method NET_PRSEQ_CREATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_AB Call by reference Type reference (TYPE) C Relationship type 20010409
2 Importing IM_PRELID Call by reference Type reference (TYPE) PPET_PRELID_LI Dependency 20010409
# Exception Resumable Description Created on
1 CREATE_FAILURE Error when creating 20010409

Method NET_SET_INSTANCE Signature

Method NET_SET_INSTANCE on class CL_PPEUIACT_CNTL has no parameter.
Method NET_SET_INSTANCE on class CL_PPEUIACT_CNTL has no exception.

Method NET_START_NETWORK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_EXCL_TAB Call by reference Type reference (TYPE) PPET_TYPE_NAME_TAB Exclusive Table for Node Types 20010409
2 Importing IM_HIDE_ASS Call by reference Type reference (TYPE) C PPET_FALSE Hide Assignment Relationships 20010409
3 Importing IM_HIDE_POF Call by reference Type reference (TYPE) C PPET_TRUE Hide Part-Of Relationships 20010409
4 Importing IM_HIDE_SEQ Call by reference Type reference (TYPE) C PPET_FALSE Hide Sequence Relationships 20010409
5 Importing IM_MODE Call by reference Type reference (TYPE) C PPET0_NET_MODE-SUBSTRUCTURE Call mode 20010409
6 Importing IM_MULT Call by reference Type reference (TYPE) C PPET_FALSE Multi-Level Display 20010409
7 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Source Node 20010409
# Exception Resumable Description Created on
1 NETWORK_ERROR Error Starting the Network Graphic 20010409

Method READ_COMP_NAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CLINT Call by reference Type reference (TYPE) PPENV_CLASS-CLINT Internal Node Class 20001205
2 Exporting EX_OTYPE Call by reference Type reference (TYPE) PVS_OTYPE iPPE Object Type 20001205
3 Exporting EX_PNTYPE Call by reference Type reference (TYPE) PVS_PNODE_TYPE iPPE Node Type 20001205
4 Exporting EX_PVTYPE Call by reference Type reference (TYPE) PVS_POSV_TYPE iPPE Variant Type 20001205
5 Exporting EX_PXGUID Call by reference Type reference (TYPE) PVS_GUID Node GUID 20001205
6 Importing IM_APPLOBJ_TYPE Call by reference Type reference (TYPE) PVS_APPLOBJ_TYPE Application Object Type for iPPE 20011214
7 Importing IM_CLASS Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Node Class 20001205
8 Importing IM_KLART Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Node Class Type 20001205
9 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Control 20020221
10 Importing IM_PNAME Call by reference Type reference (TYPE) PVS_PNODE Name of Node 20001205
11 Importing IM_PVNAME Call by reference Type reference (TYPE) PVS_POSVAR Variant 20001205
# Exception Resumable Description Created on
1 CMP_READ_ERROR Specified Component Not Found 20001205

Method READ_PVB_ACT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PAMODD_ALTNR_TAB Call by reference Type reference (TYPE) PPET2_PAMODD_ALTNUM_TAB Mode Table with Numbers for Alternatives 20010815
2 Exporting EX_PVBASS_TAB Call by reference Type reference (TYPE) PPET2_PVBASS_DYNP_TAB SA Assignment Table in Screen Format 20010718

Method READ_PVB_ACT on class CL_PPEUIACT_CNTL has no exception.

Method READ_PXTYPE_DESC Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PDESC Call by reference Type reference (TYPE) PVS_DESC Description 20001210
2 Importing IM_OTYPE Call by reference Type reference (TYPE) PVS_OTYPE Object Type 20001210
3 Importing IM_PXTYPE Call by reference Type reference (TYPE) PVS_PNODE_TYPE Customizing - Node Type 20001210

Method READ_PXTYPE_DESC on class CL_PPEUIACT_CNTL has no exception.

Method READ_SINGLE_ACT Signature

Method READ_SINGLE_ACT on class CL_PPEUIACT_CNTL has no parameter.
Method READ_SINGLE_ACT on class CL_PPEUIACT_CNTL has no exception.

Method REFRESH_ALL Signature

Method REFRESH_ALL on class CL_PPEUIACT_CNTL has no parameter.
Method REFRESH_ALL on class CL_PPEUIACT_CNTL has no exception.

Method REL_SET_INSTANCE Signature

Method REL_SET_INSTANCE on class CL_PPEUIACT_CNTL has no parameter.
# Exception Resumable Description Created on
1 INSTANCE_ERROR Error 20020128

Method SEL_PAMODD_COPYMODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ATTRCOPY Call by reference Type reference (TYPE) C Attributes Should Be Copied 'X' 20010119
2 Exporting EX_CAPCOPY Call by reference Type reference (TYPE) C Requirements Should Be Copied 20010119
3 Exporting EX_KNOBJCOPY Call by reference Type reference (TYPE) C Object Dependency Should Be Copied 'X' 20010119
4 Exporting EX_LTXCOPY Call by reference Type reference (TYPE) C Long Texts Should Be Copied 20010124
5 Exporting EX_RESCOPY Call by reference Type reference (TYPE) C Resource Should Be Copied 20010119
6 Exporting EX_TACOPY Call by reference Type reference (TYPE) C Time Analysis Data Should Be Copied 'X' 20010119
7 Importing IM_ALTTXT1 Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
8 Importing IM_ALTTXT2 Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
9 Importing IM_ALTTXT3 Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
10 Importing IM_ALTTXT4 Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
11 Importing IM_ALTTXT5 Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
12 Importing IM_ALTTXT6 Call by reference Type reference (TYPE) PPE_TEXT Description 20010124
13 Importing IM_TEXT Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
14 Importing IM_TEXT2 Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
15 Importing IM_TEXT3 Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
16 Importing IM_TITLE Call by reference Type reference (TYPE) PPE_TEXT Description 20010119
# Exception Resumable Description Created on
1 NOTHING_SELECTED No Selection Made 20010119

Method SEL_RELMDL_TYPES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PXTYPE2 Call by reference Type reference (TYPE) PVS_PNODE_TYPE iPPE Node Type 20001210
2 Importing IM_OTYPE1 Call by reference Type reference (TYPE) PVS_OTYPE iPPE Object Type 20001210
3 Importing IM_OTYPE2 Call by reference Type reference (TYPE) PVS_OTYPE iPPE Object Type 20001210
4 Importing IM_PXTYPE1 Call by reference Type reference (TYPE) PVS_PNODE_TYPE iPPE Node Type 20001210
5 Importing IM_TEXT Call by reference Type reference (TYPE) PPE_TEXT Description 20001210
6 Importing IM_TITLE Call by reference Type reference (TYPE) PPE_TEXT Description 20001210
# Exception Resumable Description Created on
1 REL_NOT_FOUND Relationship Not Found 20001210

Method SEL_RELPR_TYPES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PRTYPE Call by reference Type reference (TYPE) PVS_PNREL_TYPE iPPE Relationship Type 20001210
2 Exporting EX_PRTYPE_LI Call by reference Type reference (TYPE) PPET_PRTYPE Extended Relationship Type 20010312
3 Importing IM_APPLREL_TYPE Call by reference Type reference (TYPE) PVS_RELOBJ_TYPE Relationship Application Type 20001210
4 Importing IM_OTYPE1 Call by reference Type reference (TYPE) PVS_OTYPE iPPE Object Type 20001210
5 Importing IM_OTYPE2 Call by reference Type reference (TYPE) PVS_OTYPE iPPE Object Type 20001210
6 Importing IM_PREL_TYPE Call by reference Type reference (TYPE) PVS_REL_TYPE iPPE Relationship Type 20001210
7 Importing IM_PRTYPE_TAB Call by reference Type reference (TYPE) PPET_PRTYPE_TAB PRTYPE Table, if already exists 20010312
8 Importing IM_PXTYPE1 Call by reference Type reference (TYPE) PVS_PNODE_TYPE iPPE Node Type 20001210
9 Importing IM_PXTYPE2 Call by reference Type reference (TYPE) PVS_PNODE_TYPE iPPE Node Type 20001210
10 Importing IM_TEXT Call by reference Type reference (TYPE) PPE_TEXT TEXT-101 Description 20001210
11 Importing IM_TITLE Call by reference Type reference (TYPE) PPE_TEXT TEXT-100 Description 20001210
# Exception Resumable Description Created on
1 CANCEL_ACTION User Termination 20010316
2 REL_NOT_FOUND No Relationship Found 20001210

Method SEL_TAUSE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_TAUSE Call by reference Type reference (TYPE) PPE_TAUSE Transfer Type for Time 20001210
2 Importing IM_ALTTXT1 Call by reference Type reference (TYPE) PPE_TEXT Texts for Alternatives 20001210
3 Importing IM_ALTTXT2 Call by reference Type reference (TYPE) PPE_TEXT Texts for Alternatives 20001210
4 Importing IM_TEXT Call by reference Type reference (TYPE) PPE_TEXT Description 20001210
5 Importing IM_TITLE Call by reference Type reference (TYPE) PPE_TEXT Description 20001210
# Exception Resumable Description Created on
1 TAUSE_NOT_FOUND No Selection Made 20001210

Method SEQ_INSERT_OBJECT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_GUID_TAB Call by reference Type reference (TYPE) PPET_GUID_SEL_TAB Contains PRGUIDs for the Relevant Sequence Relationships 20010731
2 Importing IM_INSERT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Add the Node to the Sequence? 20010131
3 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL with Message Handler 20010126
4 Importing IM_NEW_OBJECT Call by reference Type reference (TYPE) PPET_PNODID_LI Node to Be Appended 20010126
5 Importing IM_NO_EVENT Call by reference Type reference (TYPE) C PPET_FALSE Event Processing 20010731
6 Importing IM_SEQ_OBJECT Call by reference Type reference (TYPE) PPET_PNODID_LI Node in the Sequence 20010126
# Exception Resumable Description Created on
1 INTERNAL_ERROR interner Fehler 20040107
2 USER_ABORT Abbruch 20040107

Method SET_ACT_STRUCT_TYPES Signature

Method SET_ACT_STRUCT_TYPES on class CL_PPEUIACT_CNTL has no parameter.
Method SET_ACT_STRUCT_TYPES on class CL_PPEUIACT_CNTL has no exception.

Method SET_EXCL_FIELD_TABS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Plantypen der iPPE-Prozessstruktur 20021025

Method SET_EXCL_FIELD_TABS on class CL_PPEUIACT_CNTL has no exception.

Method SET_MOD_RESTYPE_SEL_TAB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_MOD_RESTYPE_SEL_TAB Call by reference Type reference (TYPE) PPET2_RES_TYPE_SEL_TAB Range Table for Resource Types 20010813

Method SET_MOD_RESTYPE_SEL_TAB on class CL_PPEUIACT_CNTL has no exception.

Method SET_MOD_RES_TYPE_TAB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_MOD_RES_TYPE_TAB Call by reference Type reference (TYPE) PPET2_RES_TYPE_TAB Current Resources Table 20010813

Method SET_MOD_RES_TYPE_TAB on class CL_PPEUIACT_CNTL has no exception.

Method SET_PRODUCTIONVERSION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_ASS_JUMP Call by reference Type reference (TYPE) XFELD PPET_FALSE Jump to Assignment List 20010427
2 Importing IM_ID Call by reference Type reference (TYPE) CHAR40 ID 20010427
3 Importing IM_LOCID Call by reference Type reference (TYPE) CHAR40 Location/Plant 20010427
4 Importing IM_PRODUCT Call by reference Type reference (TYPE) CHAR40 Material/Product 20010427
5 Importing IM_PRODVERS Call by reference Type reference (TYPE) PVS_GUID Production Version GUID 20010427

Method SET_PRODUCTIONVERSION on class CL_PPEUIACT_CNTL has no exception.

Method SET_SEQUENCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_SEQ_TAB Call by reference Type reference (TYPE) PPET2_SEQ_DYNP_TAB Activity-Node Relationship Sequence 20001204
2 Importing IM_ACT_ONLY Call by reference Type reference (TYPE) XFELD Checkbox Field 20001204
3 Importing IM_MULT_FLAG Call by reference Type reference (TYPE) XFELD Checkbox Field 20001204
4 Importing IM_PNODID Call by reference Type reference (TYPE) PNODID iPPE Node 20001204

Method SET_SEQUENCE on class CL_PPEUIACT_CNTL has no exception.

Method TIMEANALYZE_ADJUST_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PAMODD Call by reference Type reference (TYPE) PAMOD_DYNP Current Mode Record 20010131
# Exception Resumable Description Created on
1 NO_ADJUST Data was not adjusted 20010131

Method TIMEANALYZE_COPY_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PAMODD Call by reference Type reference (TYPE) PAMOD_DYNP Current Mode Record 20010131
2 Importing IM_TADUR_B Call by reference Type reference (TYPE) PPE_TADUR_B_MIN Gross Time from Time Analysis 20010131
3 Importing IM_TADUR_N Call by reference Type reference (TYPE) PPE_TADUR_N_MIN Net Time from Time Analysis 20010131
# Exception Resumable Description Created on
1 NO_COPY Nothing Copied 20010131

Method TIMEANALYZE_EXIT Signature

Method TIMEANALYZE_EXIT on class CL_PPEUIACT_CNTL has no parameter.
Method TIMEANALYZE_EXIT on class CL_PPEUIACT_CNTL has no exception.

Method TIMEANALYZE_GET_VWEA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_VWEA Call by reference Type reference (TYPE) PPE_VWEA Standard Value Determination Type 20010111

Method TIMEANALYZE_GET_VWEA on class CL_PPEUIACT_CNTL has no exception.

Method UPDATE_PAMODD_AFTER_SAVE Signature

Method UPDATE_PAMODD_AFTER_SAVE on class CL_PPEUIACT_CNTL has no parameter.
Method UPDATE_PAMODD_AFTER_SAVE on class CL_PPEUIACT_CNTL has no exception.
History
Last changed by/on SAP  20050301 
SAP Release Created in 46C1