SAP ABAP Class CL_PPELIACT_CNTL (iPPE Application Object ACT)
Hierarchy
EA-IPPE (Software Component) SAP iPPE
   AP-PPE (Application Component) Integrated Product and Process Engineering
     CPPEACT (Package) ACT-Specific iPPE Objects
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CL_PPELIENG_CNTL iPPE Engine Controller Object Class 20000913
Properties
Class CL_PPELIACT_CNTL  
Short Description iPPE Application Object ACT    
Super Class CL_PPELIENG_CNTL iPPE Engine Controller Object Class 
Instantiability of a Class 0  Private 
Final    
General Data
Message Class    
Program status     
Category 0   
Package CPPEACT   ACT-Specific iPPE Objects 
Created 20000913   SAP 
Last change 20050615   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PPENV Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 PPET Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 PPET1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
4 PPET2 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
5 PPET4 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CL_PPELIACT_CNTL has no interface implemented.
Friends
Class CL_PPELIACT_CNTL has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 ENV_CHECK_EXT_ACTIVE Static Attribute Private Type reference (TYPE) XFELD Customer Check is Active 20030129
2 ENV_CHECK_EXT_INST Static Attribute Private Object reference (TYPE REF TO) IF_EX_IPPE_ACT_CHECK_EXT BAdI Interface IF_EX_IPPE_ACT_CHECK_EXT 20030128
3 INSTANCE Static Attribute Private Object reference (TYPE REF TO) CL_PPELIACT_CNTL Only Instance of Class 20000913
4 PLANTYPE_COMP_TAB Static Attribute Private Type reference (TYPE) PPET2_COMPONENT_PLAN_TAB Components Table for Task List Types 20010814
Methods
# Method Level Visibility Method type Description Created on
1 CLASS_CONSTRUCTOR Static method Public Constructor CLASS_CONSTRUCTOR 20000913
2 GET_ENV_CHECK_EXT_INST Static method Private Method Read Instance of Customer Check BAdIs 20030128
3 GET_INSTANCE Static method Public Method Gets the Instance of the Class 20000913
4 GET_PLANHDR_OF_PXXXID Static method Public Method Collection of Routing Nodes for Updating Production Version 20021127
5 GET_PLANTYPE_COMP_INSTANCE Static method Public Method Read the Class of Specific Task List Type in Process Struct. 20010815
6 GET_PLANTYPE_OD_TYPES Static method Public Method Determine Type of Supported Object Dependency 20021128
7 GET_PLANTYPE_TMS_UPDATE_TYPE Static method Public Method Determine Type of Time Stamp Update 20021017
8 PAMOD_READ_BY_CRIT Static method Public Method Read Mode According to Criteria 20030825
9 PA_MODC_DELETE Static method Public Method Delete MODC Records 20001106
10 PA_MODD_READ_BY_AENNR Static method Public Method Read PAMODD Records According to Change Number 20021008
11 PA_MODD_READ_BY_RPPNT Static method Public Method Read PAMODD Records According to Reporting Points 20050208
12 PA_MODD_READ_BY_TAIDSAP Static method Public Method Read PAMODD Records According to Time Analysis Attributes 20021008
13 PA_MODX_READ_BY_RES Static method Public Method Read PAMODD/PAMODC Records According to Resources 20021008
14 PA_MOD_MAINT Static method Public Method Create/Change MODD/MODC Records 20000922
15 PA_MOD_READ Static method Public Method Read MODD/MODC Records 20000922
16 PN_MAINT Static method Public Method Create/Change ACT Node 20000922
17 PN_READ Static method Public Method Read the Objects and Attributes of ACT Nodes 20000919
18 PN_READ_BY_ACT Static method Public Method Where-Used List for Activities and Operations 20030903
19 PN_READ_BY_CRIT Static method Public Method Read Activities/Operations According to Criteria 20030825
20 PN_READ_SINGLE Static method Public Method Read the Data for an Activity Node 20001216
21 PRELACT_EXTRACT Static method Private Method Separate PRELID and PRELACT Entries Before Saving 20021114
22 PRIOC_READ_BY_CRIT Static method Public Method Read Component Assignments by Criteria 20030825
23 PRSEQ_READ_BY_CRIT Static method Public Method Read Sequence Relationships by Criteria 20030825
24 PR_MAINT Static method Public Method Create/Change a Relationship 20021008
25 PR_READ Static method Public Method Read the Relationships of an Activity 20000925
26 PR_SEQ_READ Static method Public Method Read a Relationship of a Node 20000925
27 PR_SEQ_READ_AND_ARRANGE Static method Public Method Read the Relationships Below a Node 20001124
28 PR_SEQ_READ_SINGLE Static method Public Method Read a Sequence Relationship 20010405
29 PXARCID_AUTHORITY_CHECK Static method Public Method Authorization Check for Archiving Function 20041220
30 PXARCID_MAINT Static method Public Method Maintenance of the Archiving Indicator 20041220
31 SECRES_READ_BY_CRIT Static method Public Method Read Mode With Secondary Resources by Criteria 20030917
32 SET_ACTHD_UPDATE_TIMESTAMP Static method Private Method Update the Production Version (Reset the Time Stamp) 20021017
33 SET_ENVIRONMENT Static method Private Method Set a Range Table for Activity Customizing Types 20021004
34 SET_HDR_UPDATE_TIMESTAMP Static method Private Method Update the Production Version (Reset the Time Stamp) 20010713
35 SET_PNODID_UPDATE_TIMESTAMP Static method Private Method Update the Production Version (Reset the Time Stamp) 20030819
Events
# Event Type Visibility Description Created on
1 READ_ERROR Static Event
(1)
Public
(2)
PNREAD Error 20000921
Types
Class CL_PPELIACT_CNTL has no local type.
Method Signatures

Method CLASS_CONSTRUCTOR Signature

Method CLASS_CONSTRUCTOR on class CL_PPELIACT_CNTL has no parameter.
Method CLASS_CONSTRUCTOR on class CL_PPELIACT_CNTL has no exception.

Method GET_ENV_CHECK_EXT_INST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ACT_IMPL Call by reference Type reference (TYPE) C Kennzeichen für eine aktive Implementierung 20030128
2 Exporting EX_CHECK_EXT_INST Call by reference Object reference (TYPE REF TO) IF_EX_IPPE_ACT_CHECK_EXT BAdI-Interface IF_EX_IPPE_ACT_CHECK_EXT 20030128
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Steuert das Message-Handling der iPPE-Engine 20030128
# Exception Resumable Description Created on
1 FACTORY_CLASS_ERROR Fehler beim erzeugen des BADI's 20030128

Method GET_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_INSTANCE Call by reference Object reference (TYPE REF TO) CL_PPELIACT_CNTL iPPE Application Object ACT 20000913

Method GET_INSTANCE on class CL_PPELIACT_CNTL has no exception.

Method GET_PLANHDR_OF_PXXXID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_ACTHD_UPDATE Call by reference Type reference (TYPE) PPET2_GUID_PLANTYPE_TAB Arbeitplanköpfe für Knoten-Aktualisierung mit Plantypen 20031111
2 Exporting ET_PNODID_UPD Call by reference Type reference (TYPE) PPET_GUID_TAB Arbeitsplanobjekte für Zeitstempelupdate 20030819
3 Exporting EX_ACTHD_UPD_TAB Call by reference Type reference (TYPE) PPET_GUID_TAB Arbeitplanköpfe für Knoten-Aktualisierung 20021127
4 Exporting EX_HDR_UPD_TAB Call by reference Type reference (TYPE) PPET_GUID_TAB Arbeitplanköpfe für Einstiegsaktualisierung 20021127
5 Importing IM_APPLOBJ_TYPE Call by reference Type reference (TYPE) PVS_APPLOBJ_TYPE Anwendungsobjekttyp des iPPE 20021127
6 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message-Handling der iPPE-Engine 20021127
7 Importing IM_PALTID_TAB Call by reference Type reference (TYPE) PPET_PALTID_TAB Puffertabelle für PALTID-Sätze 20021127
8 Importing IM_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Plantypen der iPPE-Prozessstruktur 20030130
9 Importing IM_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_TAB Puffertabelle für PNODID-Sätze 20021127
10 Importing IM_PRELID_TAB Call by reference Type reference (TYPE) PPET_PRELID_HIST_TAB Puffertabelle für PRELID-Sätze 20021127
# Exception Resumable Description Created on
1 INTERNAL_ERROR interner Fehler 20031020

Method GET_PLANTYPE_COMP_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_INSTANCE Call by reference Object reference (TYPE REF TO) IF_PPELIACT_PLAN_CNTL Current oo Instance 20010815
2 Importing IM_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Routing Types in the iPPE Process Structure 20010815
# Exception Resumable Description Created on
1 INSTANCE_NOT_FOUND No Instance Found 20010815

Method GET_PLANTYPE_OD_TYPES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_OPR_SELCO Call by reference Type reference (TYPE) C Vorgang Selektionsbedingungen 20030822
2 Exporting EX_ACT_PROC Call by reference Type reference (TYPE) C Aktivität Prozeduren 20021128
3 Exporting EX_ACT_SELCO Call by reference Type reference (TYPE) C Aktivität Selektionsbedingungen 20021128
4 Exporting EX_MOD_PROC Call by reference Type reference (TYPE) C Modus Prozeduren 20021128
5 Exporting EX_MOD_SELCO Call by reference Type reference (TYPE) C Modus Selektionsbedingungen 20021128
6 Importing IM_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Plantypen der iPPE-Prozessstruktur 20021128
# Exception Resumable Description Created on
1 CHECK_ERROR Fehler bei der Ermittlung des Aktualisierungstypes 20021128

Method GET_PLANTYPE_TMS_UPDATE_TYPE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_TMS_UPDATE_ACTHD Call by reference Type reference (TYPE) C Zeitstempelaktualisierung am Arbeitsplankopf 20021017
2 Exporting EX_TMS_UPDATE_HDR Call by reference Type reference (TYPE) C Zeitstempelaktualisierung am Einstiegsobjekt 20021017
3 Importing IM_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Plantypen der iPPE-Prozessstruktur 20021017
# Exception Resumable Description Created on
1 CHECK_ERROR Fehler bei der Ermittlung des Aktualisierungstypes 20021017

Method PAMOD_READ_BY_CRIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_AENNR Call by reference Type reference (TYPE) PPET_AENNR_TAB Änderungsstände 20030825
2 Exporting ET_PALTID Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB Modus-ID's 20030825
3 Exporting ET_PAMODC Call by reference Type reference (TYPE) PPET2_PAMODC_LI_TAB Kapazitätsbedarfe 20030825
4 Exporting ET_PAMODD Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB Modusdauern 20030825
5 Exporting ET_PRIMRES Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Primärresourcen 20030912
6 Exporting ET_SECRES Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Sekundärresourcen 20030912
7 Exporting EV_COUNT Call by reference Type reference (TYPE) I Anzahl der Treffer 20030905
8 Importing IT_AENNR_SEL Call by reference Type reference (TYPE) PPENV_AENNR_SEL_TAB Selektionstabelle für Änderungsnummern 20030825
9 Importing IT_CHNGBY_SEL Call by reference Type reference (TYPE) PPET_CHNGBY_SEL_TAB Selektionstabelle für Änderer 20030825
10 Importing IT_CHNGDAT_SEL Call by reference Type reference (TYPE) PPET_CHNGDAT_SEL_TAB Selektionstabelle für Änderungsdatum 20030825
11 Importing IT_CREABY_SEL Call by reference Type reference (TYPE) PPET_CREABY_SEL_TAB Selektionstabelle für Anleger 20030825
12 Importing IT_CREADAT_SEL Call by reference Type reference (TYPE) PPET_CREADAT_SEL_TAB Selektionstabelle für Anlegedatum 20030825
13 Importing IT_MOD_LOCATION_SEL Call by reference Type reference (TYPE) PPENV_LOCID_SEL_TAB Selektionstabelle für Moduslokationen 20030825
14 Importing IT_MOD_SEL Call by reference Type reference (TYPE) PPET_ALTNUM_SEL_TAB Selektionstabelle für Modus 20030825
15 Importing IT_PRIM_RES_SEL Call by reference Type reference (TYPE) PPET2_PRIMRES_SEL_TAB Selektionstabelle für Primärresourcen 20030825
16 Importing IT_SEC_RES_SEL Call by reference Type reference (TYPE) PPET2_SECRES_SEL_TAB Selektionstabelle für Sekundärresourcen 20030825
17 Importing IV_AENNR_FLG Call by reference Type reference (TYPE) C PPET_TRUE Änderungsstände zurückliefern 20030905
18 Importing IV_COUNT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Nur Anzahl der Treffer bestimmen 20030905
19 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichtenbehandlung im iPPE 20030825
20 Importing IV_PALTID_FLG Call by reference Type reference (TYPE) C PPET_TRUE Alternativen-ID's lesen 20030905
21 Importing IV_PAMODC_FLG Call by reference Type reference (TYPE) C PPET_FALSE PAMODC-Sätze lesen 20030905
22 Importing IV_PAMODD_FLG Call by reference Type reference (TYPE) C PPET_FALSE PAMODD-Sätze lesen 20030905
23 Importing IV_PRIMRES_FLG Call by reference Type reference (TYPE) C PPET_FALSE ID's der Primärresourcen lesen 20030915
24 Importing IV_SECRES_FLG Call by reference Type reference (TYPE) C PPET_FALSE ID's der Sekundärresourcen lesen 20030915
# Exception Resumable Description Created on
1 ERROR Allgemeiner Fehler 20030825

Method PA_MODC_DELETE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext-Umfeld des iPPE (z.B. Focus) 20031007
2 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE Model 20001106
3 Importing IM_NO_EVENT Call by reference Type reference (TYPE) C PPET_FALSE Do not trigger an event for interface refresh 20010111
4 Importing IM_NO_MSG Call by reference Type reference (TYPE) C PPET_FALSE Suppress Success Message 20010111
5 Importing IM_PALTID Call by reference Type reference (TYPE) PPET_PALTID_LI Alternative 20001106
6 Importing IM_PAMODC Call by reference Type reference (TYPE) PPET2_PAMODC_LI MODC Record 20001106
7 Importing IM_SENDER Call by reference Type reference (TYPE) PPET_SENDER Program Calling the LI Methods/Function 20010111
# Exception Resumable Description Created on
1 AENNR_NOT_VALID Invalid Change Number 20001106
2 AENNR_REQUIRED Change Number Required 20001106
3 MODE_DOES_NOT_EXIST Mode Does Not Exist 20001106
4 NO_AUTHORITY No Authorization 20001106
5 NO_DELETE Mode Was Not Deleted 20001106
6 NO_PAMOD Mode Does Not Exist 20001106
7 PALTID_ERROR Alternative Does Not Exist 20001106

Method PA_MODD_READ_BY_AENNR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_AENNR_TAB Call by reference Type reference (TYPE) PPET_AENNR_TAB Tabelle der betroffenden Objekte 20021008
2 Importing IM_AENNR Call by reference Type reference (TYPE) PPET_AENNR-AENNR Änderungsnummer nach der gesucht wird! 20021008

Method PA_MODD_READ_BY_AENNR on class CL_PPELIACT_CNTL has no exception.

Method PA_MODD_READ_BY_RPPNT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PAMODD Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB gefundene PAMODD Sätze 20050208
2 Importing IV_BUFFER_BYPASS Call by reference Type reference (TYPE) C Buffer nicht beachten 20050208
3 Importing IV_RPGUID Call by reference Type reference (TYPE) PPE_PGUID_REF Identifikation der Objektreferenz im iPPE 20050208

Method PA_MODD_READ_BY_RPPNT on class CL_PPELIACT_CNTL has no exception.

Method PA_MODD_READ_BY_TAIDSAP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PALTID_TAB Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB Alternativentabelle Modi 20021008
2 Exporting EX_PAMODD_TAB Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB Attributtabelle der Modi 20021008
3 Exporting EX_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Knotentabelle Aktivitäten 20021008
4 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL mit Message-Handler 20021008
5 Importing IM_TAIDSAP_TAB Call by reference Type reference (TYPE) PPET2_TAIDSAP_TAB Zeitanalyse Tab mit Guids der Alternativen 20021008
# Exception Resumable Description Created on
1 INTERNAL_ERROR allgemeiner Fehler 20021008
2 NO_NODES_FOUND keine Aktivitäten gefunden 20021008

Method PA_MODX_READ_BY_RES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_AENNR_RED_TAB Call by reference Type reference (TYPE) PPET_AENNR_TAB historische Stände aber ohne Zähler 20021008
2 Exporting EX_AENNR_TAB Call by reference Type reference (TYPE) PPET_COUNT_AENNR_TAB historische Stände der relevanten Modi 20021008
3 Exporting EX_PALTID_TAB Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB Tabelle der betroffenen Alternativen (nur GUID) 20021008
4 Exporting EX_PAMODC_TAB Call by reference Type reference (TYPE) PPET2_PAMODC_LI_TAB Tabelle der MODC-Sätze 20021008
5 Exporting EX_PAMODD_TAB Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB Tabelle der MODD-Sätze 20021008
6 Exporting EX_USED_ON_MODC Call by reference Type reference (TYPE) C Ressource ist Kapazitätsbedarf 'X' 20021008
7 Exporting EX_USED_ON_MODD Call by reference Type reference (TYPE) C Ressource ist terminierungsrelevant 20021008
8 Importing IM_CHECK_USE_ONLY Call by reference Type reference (TYPE) C PPET_FALSE Prüfung auf Verwendung 20021008
9 Importing IM_RESOURCE Call by reference Type reference (TYPE) PPET_PNODID_LI Ressourcenknoten 20021008

Method PA_MODX_READ_BY_RES on class CL_PPELIACT_CNTL has no exception.

Method PA_MOD_MAINT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PALTID Call by reference Type reference (TYPE) PPET_PALTID_LI Alternative 20000922
2 Changing CH_PAMODC_TAB Call by reference Type reference (TYPE) PPET2_PAMODC_LI_TAB MODC Records 20000922
3 Changing CH_PAMODD Call by reference Type reference (TYPE) PPET2_PAMODD_LI MODD Record 20000922
4 Changing CH_PVSTX_TAB Call by reference Type reference (TYPE) PPET_PPETX_LI_TAB Texts 20000922
5 Exporting EX_CREATED Call by reference Type reference (TYPE) C Specifies whether new record generates 'X' or not 20001020
6 Exporting EX_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Nodes 20000922
7 Importing IM_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext im iPPE-Umfeld 20021129
8 Importing IM_COPY_CNT Call by reference Type reference (TYPE) INT2 0 Counts number of times copying routine has been accessed 20001220
9 Importing IM_CREATE_FLG Call by reference Type reference (TYPE) C PPET_TRUE Indicator: Create a New Mode 20001012
10 Importing IM_DEL_FLG Call by reference Type reference (TYPE) C PPET_FALSE Generate Deletion Record (Deletion with History) 20001020
11 Importing IM_EXISTS Call by reference Type reference (TYPE) C PPET_FALSE Indicator: Copy Alternative/Mode Exists 20001220
12 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE Model 20000922
13 Importing IM_NO_EVENT Call by reference Type reference (TYPE) C PPET_FALSE Suppress the Refresh Event 20010109
14 Importing IM_PADESC Call by reference Type reference (TYPE) PVS_DESC Description of iPPE Object Type 20001220
15 Importing IM_PALTID_EXT Call by reference Type reference (TYPE) PPET_PALTID_EXT External Description 20001220
16 Importing IM_PATYPE Call by reference Type reference (TYPE) PPET_PATYPE Technical Description 20001220
17 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Carrier Object Node of the PALTID Copy 20001220
18 Importing IM_RESET_SIGN Call by reference Type reference (TYPE) C SPACE Reset-Sign für Kurztexte 20020910
19 Importing IM_SENDER Call by reference Type reference (TYPE) PPET_SENDER Program Calling the Method/FM 20010109
20 Importing IM_SOURCE_OBJECT Call by reference Type reference (TYPE) PPET_AENNR ursprüngliches Objekt beim Kopieren 20020917
# Exception Resumable Description Created on
1 AENNR_NOT_VALID Invalid Change Number 20000922
2 AENNR_REQUIRED Change Number Does Not Exist 20000922
3 BUFFER_FAILURE Error During Buffer Processing 20000925
4 ECN_REQUIRED Change Number Required 20001024
5 MAINTAIN_ERROR Creation Error 20000925
6 MODUSC_NOT_VALID Invalid Mode 20001024
7 MODUSD_NOT_VALID Error in Mode D Record 20001024
8 NO_ASSIGNED_PAMOD No Mode D Record Found for Assignment of Mode C Records 20001024
9 NO_AUTHORITY No Change Authorization 20001026
10 NO_GUID Could Not Generate GUID 20000926
11 NO_PAMOD No Mode 20000922
12 PALTID_ERROR PALTID Error 20000922
13 PALTID_NOT_VALID Alternative not valid 20000922
14 UNKNOWN_SPRAS Unknown Language 20000922

Method PA_MOD_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PALTID_TAB Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB Node Identification 20000922
2 Exporting EX_AENNR_TAB Call by reference Type reference (TYPE) PPET_AENNR_TAB Change Numbers Read for Alternatives 20000922
3 Exporting EX_LOCKED_TAB Call by reference Type reference (TYPE) PPET_LOCKED_TAB gesperrte Objekte 20021213
4 Exporting EX_PALTTX_TAB Call by reference Type reference (TYPE) PPET_PALTTX_LI_TAB Alternative Texts 20000922
5 Exporting EX_PAMODC_TAB Call by reference Type reference (TYPE) PPET2_PAMODC_LI_TAB Application Data for PAMODC Records 20000922
6 Exporting EX_PAMODD_TAB Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB Application Data for PAMODD Records 20000922
7 Exporting EX_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Altenative Identification 20000922
8 Importing IM_AENNR Call by reference Type reference (TYPE) PPET_AENNR-AENNR Read with Change Number 20000922
9 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE Model 20000922
# Exception Resumable Description Created on
1 NO_AUTHORITY No Authorization to Read 20001026
2 PAACT_ERROR Error Reading the ACT Alternatives 20000922

Method PN_MAINT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PNACT Call by reference Type reference (TYPE) PPET2_PNACT_LI PNACT Record of the ACT Node 20000922
2 Changing CH_PNACTHD Call by reference Type reference (TYPE) PPET2_PNACTHD_LI Attribute des Arbeitsplankopfes 20021022
3 Changing CH_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI PNODID Record of the ACT Node 20000922
4 Changing CH_PNODTX_TAB Call by reference Type reference (TYPE) PPET_PPETX_LI_TAB Text Table for the ACT Node 20000922
5 Changing CS_PNACTOPR Call by reference Type reference (TYPE) PPET2_PNACTOPR_LI Attribute des Vorganges 20030825
6 Importing IM_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Context Environment in iPPE (E.g. Focus) 20001219
7 Importing IM_CREATE_FLG Call by reference Type reference (TYPE) C PPET_TRUE PNODID Record Can Be Created 20000922
8 Importing IM_EXISTS Call by reference Type reference (TYPE) C PPET_FALSE Indicator: Node Already Exists 20001201
9 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in iPPE Engine 20000922
10 Importing IM_NO_EVENT Call by reference Type reference (TYPE) C PPET_FALSE Suppress the Refresh Event 20010109
11 Importing IM_PNDESC Call by reference Type reference (TYPE) PVS_DESC External Description of the Type 20001201
12 Importing IM_PNODID_EXT Call by reference Type reference (TYPE) PPET_PNODID_EXT External Description 20001201
13 Importing IM_RESET_SIGN Call by reference Type reference (TYPE) C SPACE Reset-Sign für Kurztexte 20020910
14 Importing IM_SENDER Call by reference Type reference (TYPE) PPET_SENDER Program Calling the Method/FM 20010109
15 Importing IM_SOURCE_OBJECT Call by reference Type reference (TYPE) PPET_AENNR ursprüngliches Objekt beim Kopieren 20020917
16 Importing IM_SUBST_DATA Call by reference Type reference (TYPE) C PPET_FALSE Corresponding data will be deleted and the new data added 20010725
# Exception Resumable Description Created on
1 PNACT_CHECK_ERROR Error Checking the PNACT Record 20000922
2 PNACT_MAINT_ERROR Error Changing the PNACT Record in the Buffer 20000922
3 PNODID_CHECK_ERROR Error Checking the PNODID Record 20000922
4 PNODID_MAINT_ERROR Error Changing the PNODID Record in the Buffer 20000922
5 PNODTX_MAINT_ERROR Error Changing the PNODTX Record in the Buffer 20000922

Method PN_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Node Table 20000921
2 Exporting ET_PNACTOPR Call by reference Type reference (TYPE) PPET2_PNACTOPR_LI_TAB Vorgangs-Datentabelle 20030825
3 Exporting EX_AENNR_TAB Call by reference Type reference (TYPE) PPET_AENNR_TAB Table of Change Statuses 20001107
4 Exporting EX_LOCKED_TAB Call by reference Type reference (TYPE) PPET_LOCKED_TAB List of Locked ACT Nodes 20000922
5 Exporting EX_PALTID_TAB Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB Alternatives Table 20000921
6 Exporting EX_PALTTX_TAB Call by reference Type reference (TYPE) PPET_PALTTX_LI_TAB Table of Texts for Alternatives 20000921
7 Exporting EX_PAMODC_TAB Call by reference Type reference (TYPE) PPET2_PAMODC_LI_TAB PAMODC Record Table 20000921
8 Exporting EX_PAMODD_TAB Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB PAMODD Record Table 20000921
9 Exporting EX_PNACTHD_TAB Call by reference Type reference (TYPE) PPET2_PNACTHD_LI_TAB Arbeitsplankopf Datentabelle 20021022
10 Exporting EX_PNACT_TAB Call by reference Type reference (TYPE) PPET2_PNACT_LI_TAB Activity Node Table 20000921
11 Exporting EX_PNODTX_TAB Call by reference Type reference (TYPE) PPET_PNODTX_LI_TAB Text Table 20000921
12 Importing IM_LOCK_FLG Call by reference Type reference (TYPE) C Lock Node when Reading 20000921
13 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL with Message Handler 20000921
14 Importing IM_SYNC_FLG Call by reference Type reference (TYPE) C PPET_FALSE Objekte synchronisieren 20050607
15 Importing IM_WITH_TEXT Call by reference Type reference (TYPE) C PPET_TRUE Read with Texts 20000921
# Exception Resumable Description Created on
1 PN_READ_ERROR Error: Read Access 20001204

Method PN_READ_BY_ACT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_GRP Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB übergeordnete Teilarbeitspläne 20030903
2 Exporting ET_HD Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB übergeordnete Arbeitsplanköpfe 20030903
3 Exporting ET_OPR Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB übergeordnete Vorgänge 20030903
4 Exporting ET_STRUCT Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB zugehörige Zerlegungsbeziehungen 20030903
5 Importing IT_ACT Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Tabelle der gegebenen Aktivitäten 20030903
6 Importing IT_OPR Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Tabelle der gegebenen Vorgänge 20030903
7 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE-Modell 20030903
# Exception Resumable Description Created on
1 INTERNAL_ERROR interner Fehler 20030903

Method PN_READ_BY_CRIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_ACT Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB ID's der Aktivitäten 20030825
2 Exporting ET_ACTHDR Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB ID's der Arbeitspläne 20030923
3 Exporting ET_OPR Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB ID's der Vorgänge 20030825
4 Exporting ET_PNACT Call by reference Type reference (TYPE) PPET2_PNACT_LI_TAB Anwendungsdaten der Aktivitäten 20030825
5 Exporting EV_COUNT Call by reference Type reference (TYPE) I Anzahl der Treffer 20030905
6 Importing IT_ACTTYPE_SEL Call by reference Type reference (TYPE) PPET2_ACTTYPE_SEL_TAB Selektionstabelle für Aktivitätentyp 20030825
7 Importing IT_ACT_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Aktivitäten 20030825
8 Importing IT_CHNGBY_SEL Call by reference Type reference (TYPE) PPET_CHNGBY_SEL_TAB Selektionstabelle für Änderer 20030825
9 Importing IT_CHNGDAT_SEL Call by reference Type reference (TYPE) PPET_CHNGDAT_SEL_TAB Selektionstabelle für Änderungsdatum 20030825
10 Importing IT_CREABY_SEL Call by reference Type reference (TYPE) PPET_CREABY_SEL_TAB Selektionstabelle für Anleger 20030825
11 Importing IT_CREADAT_SEL Call by reference Type reference (TYPE) PPET_CREADAT_SEL_TAB Selektionstabelle für Anlegedatum 20030825
12 Importing IT_OPR_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Vorgänge 20030825
13 Importing IT_ROUTING_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Arbeitsplanköpfe 20030922
14 Importing IV_ACT_FLG Call by reference Type reference (TYPE) C PPET_TRUE Aktivitäten lesen 20031008
15 Importing IV_COUNT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Nur Anzahl der Treffer lesen 20030905
16 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichtenbehandlung im iPPE 20030825
17 Importing IV_OPR_FLG Call by reference Type reference (TYPE) C PPET_TRUE Vorgänge lesen 20031008
18 Importing IV_ROUTING_FLG Call by reference Type reference (TYPE) C PPET_TRUE Arbeitspläne lesen 20031008
# Exception Resumable Description Created on
1 ERROR Allgemeiner Fehler 20030825

Method PN_READ_SINGLE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_PNACTOPR Call by reference Type reference (TYPE) PPET2_PNACTOPR_LI Datenrucksack Vorgang 20030825
2 Exporting EX_AENNR_TAB Call by reference Type reference (TYPE) PPET_AENNR_TAB Table of Change Numbers 20001216
3 Exporting EX_PALTID_TAB Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB Table of Modes 20001216
4 Exporting EX_PALTTX_TAB Call by reference Type reference (TYPE) PPET_PALTTX_LI_TAB Table of Mode Texts 20001216
5 Exporting EX_PAMODC_TAB Call by reference Type reference (TYPE) PPET2_PAMODC_LI_TAB Secondary Resources 20001216
6 Exporting EX_PAMODD_TAB Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB Primary Resources 20001216
7 Exporting EX_PNACT Call by reference Type reference (TYPE) PPET2_PNACT_LI Additional Data for Activity Node 20001216
8 Exporting EX_PNACTHD Call by reference Type reference (TYPE) PPET2_PNACTHD_LI Datenrucksack Arbeitsplankopfdaten 20021022
9 Exporting EX_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Node Data 20010911
10 Exporting EX_PNODTX_TAB Call by reference Type reference (TYPE) PPET_PNODTX_LI_TAB Activity Node Texts 20001216
11 Importing IM_MSG_HANDLER Call by reference Type reference (TYPE) C PPET_MSG_HANDLER-DIALOG steuert das Ziel der Nachricht 20021009
12 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message Handling der iPPE Engine 20021009
13 Importing IM_PNGUID Call by reference Type reference (TYPE) PVS_GUID Activity GUID 20001216
14 Importing IM_WITH_TXT Call by reference Type reference (TYPE) C PPET_TRUE Read with Texts 20001216
# Exception Resumable Description Created on
1 PN_READ_ERROR Read Error 20001216

Method PRELACT_EXTRACT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PRELACT_TAB Call by reference Type reference (TYPE) PPET2_PRELACT_TAB 20021114
2 Exporting EX_PRELID_TAB Call by reference Type reference (TYPE) PPET_PRELID_TAB 20021114
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message Handling der iPPE Engine 20021114
4 Importing IM_PRELID_TAB Call by reference Type reference (TYPE) PPET_PRELID_TAB 20021114
# Exception Resumable Description Created on
1 PRELACT_EXTRACT_ERROR Fehler bei der Trennung von PRELID und PRELACT-Enträgen 20021114

Method PRIOC_READ_BY_CRIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Knoten-ID's 20030825
2 Exporting ET_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI_TAB Varianten-ID's 20030825
3 Exporting ET_PRELID Call by reference Type reference (TYPE) PPET_PRELID_LI_TAB Komponentenzuordnungen 20030905
4 Exporting ET_PRIOC Call by reference Type reference (TYPE) PPET2_PRIOC_LI_TAB Komponentenzuordnungen 20030825
5 Exporting EV_COUNT Call by reference Type reference (TYPE) I Anzahl der Treffer 20030905
6 Importing IT_ACT_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Aktivitäten 20030825
7 Importing IT_CHNGBY_SEL Call by reference Type reference (TYPE) PPET_CHNGBY_SEL_TAB Selektionstabelle für Änderer 20030825
8 Importing IT_CHNGDAT_SEL Call by reference Type reference (TYPE) PPET_CHNGDAT_SEL_TAB Selektionstabelle für Änderungsdatum 20030825
9 Importing IT_CLASS_SEL Call by reference Type reference (TYPE) PPET_CLINT_SEL_TAB Selektionstabelle für Klassen 20030825
10 Importing IT_CREABY_SEL Call by reference Type reference (TYPE) PPET_CREABY_SEL_TAB Selektionstabelle für Anleger 20030825
11 Importing IT_CREADAT_SEL Call by reference Type reference (TYPE) PPET_CREADAT_SEL_TAB Selektionstabelle für Anlegedatum 20030825
12 Importing IT_OPR_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Vorgänge 20030825
13 Importing IT_PNAME_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für PVS-Pnoten 20030825
14 Importing IT_PVNAME_SEL Call by reference Type reference (TYPE) PPET_POSVAR_SEL_TAB Selektionstabelle für Varianten 20030825
15 Importing IV_COUNT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Nur anzahl der Treffer bestimmen 20030905
16 Importing IV_IOCOMPONENT Call by reference Type reference (TYPE) PPE_IOCOMPONENT 20030826
17 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichtenbehandlung im iPPE 20030825
18 Importing IV_PNODID_FLG Call by reference Type reference (TYPE) C PPET_FALSE Knoten-ID's lesen 20030905
19 Importing IV_POSVID_FLG Call by reference Type reference (TYPE) C PPET_FALSE Varianten-ID's lesen 20030905
20 Importing IV_PRIOC_FLG Call by reference Type reference (TYPE) C PPET_FALSE PRIOC-Sätze lesen 20030905
# Exception Resumable Description Created on
1 ERROR Allgemeiner Fehler 20030825

Method PRSEQ_READ_BY_CRIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Knoten-ID's 20030825
2 Exporting ET_PRELID Call by reference Type reference (TYPE) PPET_PRELID_LI_TAB Sequenzbeziehungen 20030905
3 Exporting ET_PRSEQ Call by reference Type reference (TYPE) PPET2_PRSEQ_LI_TAB Sequenzbeziehungen 20030825
4 Exporting EV_COUNT Call by reference Type reference (TYPE) I Anzahl der Treffer 20030905
5 Importing IT_ACT_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Aktivitäten 20030825
6 Importing IT_CHNGBY_SEL Call by reference Type reference (TYPE) PPET_CHNGBY_SEL_TAB Selektionstabelle für Änderungsdatum 20030825
7 Importing IT_CHNGDAT_SEL Call by reference Type reference (TYPE) PPET_CHNGDAT_SEL_TAB Selektionstabelle für Änderungsdatum 20030825
8 Importing IT_COUPLE_TYPE_SEL Call by reference Type reference (TYPE) PPET2_MODECOUPLE_SEL_TAB Selektionstabelle für Art der Moduskopplung 20030825
9 Importing IT_COVER_FLG_SEL Call by reference Type reference (TYPE) PPET2_COVER_FLG_SEL_TAB Selektionstabelle für durchgängige Belegung 20030825
10 Importing IT_CREABY_SEL Call by reference Type reference (TYPE) PPET_CREABY_SEL_TAB Selektionstabelle für Anleger 20030825
11 Importing IT_CREADAT_SEL Call by reference Type reference (TYPE) PPET_CREADAT_SEL_TAB Selektionstabelle für Anlegedatum 20030825
12 Importing IT_CRTYPE_SEL Call by reference Type reference (TYPE) PPET2_CRTYPE_SEL_TAB Selektionstabelle für Anordnungsbeziehungen 20030825
13 Importing IT_OPR_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Vorgänge 20030825
14 Importing IT_PRED_ACT_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Vorgänger-Aktivitäten 20030825
15 Importing IT_ROUTING_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Arbeitspläne 20030905
16 Importing IT_SUCC_ACT_SEL Call by reference Type reference (TYPE) PPET_PNAME_SEL_TAB Selektionstabelle für Nachfolger-Aktivitäten 20030825
17 Importing IV_COUNT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Nur die Anzahl der Treffer lesen 20030905
18 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichtenbehandlung im iPPE 20030825
19 Importing IV_PNODID_FLG Call by reference Type reference (TYPE) C PPET_FALSE Knoten-ID's lesen 20030905
20 Importing IV_PRSEQ_FLG Call by reference Type reference (TYPE) C PPET_FALSE PRSEQ-Sätze lesen 20030905
# Exception Resumable Description Created on
1 ERROR Allgemeiner Fehler 20030825

Method PR_MAINT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PRELID Call by reference Type reference (TYPE) PPET_PRELID_LI Beziehung 20021008
2 Changing CH_PRIOC Call by reference Type reference (TYPE) PPET2_PRIOC_LI Anwendungsdaten Zuordnungsbeziehung 20021008
3 Changing CH_PRSEQ Call by reference Type reference (TYPE) PPET2_PRSEQ_LI Anwendungsdaten Anordnungsbeziehung 20021008
4 Changing CT_PRSEQ_ADD Call by reference Type reference (TYPE) PPET2_PRSEQ2_LI_TAB zusätzliche Anordnungsbeziehung 20030901
5 Exporting EX_OP_ID Call by reference Type reference (TYPE) C durchgeführte Operation 20021008
6 Importing IM_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext-Umfeld im iPPE (z.B. Focus) 20021008
7 Importing IM_CREATE_FLG Call by reference Type reference (TYPE) C PPET_TRUE Flag: Anlegen einer neuen Sequenzkante 20021008
8 Importing IM_EXISTS Call by reference Type reference (TYPE) C PPET_FALSE Flag: Kopie existiert bereits 20021008
9 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE-Modell 20021008
10 Importing IM_NO_EVENT Call by reference Type reference (TYPE) C PPET_FALSE Flag: Refresh-Event unterdrücken 20021008
11 Importing IM_OBJ1_EXT_COPY Call by reference Type reference (TYPE) PPET_RELOBJ_EXT Startobjekt (Kopie) 20021008
12 Importing IM_OBJ2_EXT_COPY Call by reference Type reference (TYPE) PPET_RELOBJ_EXT Zielobjekt (Kopie) 20021008
13 Importing IM_PRDESC_COPY Call by reference Type reference (TYPE) PVS_DESC Beschreibung (Kopie) 20021008
14 Importing IM_PRTYPE_COPY Call by reference Type reference (TYPE) PPET_PRTYPE Technischer Type (Kopie) 20021008
15 Importing IM_SENDER Call by reference Type reference (TYPE) PPET_SENDER Aufrufer der Methode/des FBs 20021008
# Exception Resumable Description Created on
1 APPL_DATA_NOT_VALID Fehler in Anwendungsdaten 20021008
2 GENERAL_PRELID_ERROR allgemeiner Beziehungsfehler 20021008
3 INTERNAL_ERROR Allgemeiner Fehler 20021008
4 WRONG_APPL_REL_TYPE Kein zulässiger Beziehungstyp 20021008

Method PR_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PRSEQ_ADD Call by reference Type reference (TYPE) PPET2_PRSEQ2_LI_TAB ID-Sätze der zusätzlichen Sequenzkanten 20030902
2 Exporting EX_PALTID_TAB Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB ID Records for the Affected iPPE Alternatives 20000925
3 Exporting EX_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB ID Records for the Affected iPPE Nodes 20000925
4 Exporting EX_POSVID_TAB Call by reference Type reference (TYPE) PPET_POSVID_LI_TAB ID Records for the Affected iPPE Variants 20000925
5 Exporting EX_PRELID_IOC_TAB Call by reference Type reference (TYPE) PPET_PRELID_LI_TAB ID Records for I/O Relationships 20001116
6 Exporting EX_PRELID_POF_TAB Call by reference Type reference (TYPE) PPET_PRELID_LI_TAB ID Records for Part-of Relationships 20001116
7 Exporting EX_PRELID_SEQ_TAB Call by reference Type reference (TYPE) PPET_PRELID_LI_TAB ID Records for Sequence Relationships 20001116
8 Exporting EX_PRIOC_TAB Call by reference Type reference (TYPE) PPET2_PRIOC_LI_TAB ID Records for the Affected Input/Output Relationships 20000925
9 Exporting EX_PRSEQ_TAB Call by reference Type reference (TYPE) PPET2_PRSEQ_LI_TAB ID Records for the Affected Sequence Relationships 20000925
10 Exporting EX_PSTRUCT_TAB Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB Relation table 20000925
11 Importing IM_DATA_READ Call by reference Type reference (TYPE) C PPET_TRUE Distribute Container Data and Relationship Types 20001117
12 Importing IM_FLG_CHILD Call by reference Type reference (TYPE) C Read from Object 1 to the Predecessor 20000925
13 Importing IM_FLG_CLOSED Call by reference Type reference (TYPE) C PPET_FALSE Only Read Relationships Between Objects in the GUID Table 20000925
14 Importing IM_FLG_MULT Call by reference Type reference (TYPE) C PPET_FALSE Read Multi-Levels 20000925
15 Importing IM_FLG_PARENT Call by reference Type reference (TYPE) C Read from Object 2 to the Predecessor 20000925
16 Importing IM_FLG_TREE Call by reference Type reference (TYPE) C PPET_FALSE Read in "Tree Mode" 20000925
17 Importing IM_FLG_WITHIDS Call by reference Type reference (TYPE) C PPET_TRUE Read ID Records for the "Affected" Objects 20000925
18 Importing IM_LOCK_FLG Call by reference Type reference (TYPE) C Lock Relationships 20000925
19 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE Engine 20000925
20 Importing IM_PGUID_TAB Call by reference Type reference (TYPE) PPET_GUID_TAB Table with GUIDs for the Start and End Objects 20000925
21 Importing IM_PRTYPE_TAB Call by reference Type reference (TYPE) PPET_TYPE_NAME_TAB Only Read Certain Types of Relationships 20000925
22 Importing IM_PSTRUCT_TAB Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB Relation table 20000925
# Exception Resumable Description Created on
1 NO_READ_AUTHORITY No Authorization to Read 20000925

Method PR_SEQ_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PRSEQ_ADD Call by reference Type reference (TYPE) PPET2_PRSEQ2_LI_TAB ID-Sätze der zusätzlichen Sequenzkanten 20030902
2 Exporting EX_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB ID Records for the Affected iPPE Nodes 20000926
3 Exporting EX_PRSEQ_TAB Call by reference Type reference (TYPE) PPET2_PRSEQ_LI_TAB ID Records for the Affected Sequence Relationships 20000926
4 Exporting EX_PRSTRUCT_TAB Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB Relation table 20000926
5 Importing IM_FLAG_CHILD Call by reference Type reference (TYPE) C PPET_TRUE Read Successor 'X' 20010126
6 Importing IM_FLAG_PARENT Call by reference Type reference (TYPE) C PPET_TRUE Read Predecessor 'X' 20010126
7 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL with Message Handler 20000926
8 Importing IM_PLANTYPE Call by reference Type reference (TYPE) PPE_PLANTYPE Task List Type of the Current Object 20010710
9 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI iPPE Node ID 20000926
# Exception Resumable Description Created on
1 NO_PNTYPE No Node Type Exists (Customizing) 20000926
2 NO_PRTYPE No Relationship Type Exists (Customizing) 20000926
3 VALID_APPLOBJ_TYPE No Activity Object 20000926
4 VALID_PRELID Invalid Relationship ID 20000926

Method PR_SEQ_READ_AND_ARRANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PRSEQ_ADD Call by reference Type reference (TYPE) PPET2_PRSEQ2_LI_TAB ID-Sätze der zusätzlichen Sequenzkanten 20030902
2 Exporting ET_STRUCT_POF Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB alle Zerlegungsbeziehungen 20030901
3 Exporting EX_ACT_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Table of Activity Nodes 20010731
4 Exporting EX_END_OBJECTS Call by reference Type reference (TYPE) PPET2_PNGUID_LEVEL_TAB Table of End Objects in a Sequence 20010202
5 Exporting EX_FREE_NODES_TAB Call by reference Type reference (TYPE) PPET2_PNODID_LEVEL_TAB Nodes that Are Not Connected by Sequence Relationships 20001127
6 Exporting EX_HEADOBJCNT Call by reference Type reference (TYPE) PPET2_OBJNR_PNGUID_TAB Table of Higher-Level Objects for Nodes 20010206
7 Exporting EX_OPSTRUCT_TAB Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB All Relationships Between Predecessors and Activities 20010802
8 Exporting EX_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB ID Records for the Affected iPPE Nodes 20001124
9 Exporting EX_PRSEQ_TAB Call by reference Type reference (TYPE) PPET2_PRSEQ_LI_TAB ID Records for the Affected Sequence Relationships 20001124
10 Exporting EX_PRSTRUCT_TAB Call by reference Type reference (TYPE) PPET2_OBJNR_STRUCT_TAB Sorted Relationship Table 20001124
11 Exporting EX_START_OBJECTS Call by reference Type reference (TYPE) PPET2_PNGUID_LEVEL_TAB Table of Start Objects in a Sequence 20010202
12 Importing IM_ACT_ONLY Call by reference Type reference (TYPE) C PPET_FALSE Interrupt on Activity Level 20001124
13 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL with Message Handler 20001124
14 Importing IM_MULT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Read Multi-Levels 20001124
15 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI iPPE Node ID 20001124
16 Importing IM_PNODID_TAB Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB All Nodes from the Routing 20010221
17 Importing IM_START_END_ONLY_FLG Call by reference Type reference (TYPE) C PPET_FALSE Read Start and End Objects Only 20010202
18 Importing IM_STRUCT_POF_TAB Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB Hierarchy Table for Complete Routing 20010221
19 Importing IM_STRUCT_SEQ_TAB Call by reference Type reference (TYPE) PPET_STRUCT_LI_TAB Sequence Table for Complete Routing 20010221
# Exception Resumable Description Created on
1 NO_PNTYPE No Node Type Exists (Customizing) 20001124
2 NO_PRTYPE No Relationship Type Exists (Customizing) 20001124
3 RECURSION_DETECTED Rekursion detektiert 20031001
4 VALID_APPLOBJ_TYPE No Activity Object 20001124
5 VALID_PRELID Invalid Relationship ID 20001124

Method PR_SEQ_READ_SINGLE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PRELID Call by reference Type reference (TYPE) PPET_PRELID_LI Sequence Relationship 20010405
2 Exporting ET_PRSEQ_ADD Call by reference Type reference (TYPE) PPET2_PRSEQ2_LI_TAB ID-Sätze der zusätzlichen Sequenzkanten 20030902
3 Exporting EX_PRSEQ Call by reference Type reference (TYPE) PPET2_PRSEQ_LI ID Records for the Affected Sequence Relationships 20010405
4 Importing IM_DATA_READ Call by reference Type reference (TYPE) C PPET_TRUE Distribute Container Data and Relationship Types 20010405
5 Importing IM_FLG_WITHIDS Call by reference Type reference (TYPE) C PPET_TRUE Read ID Records for the "Affected" Objects 20010405
6 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE Engine 20010405
# Exception Resumable Description Created on
1 NO_READ_AUTHORITY No Authorization to Read 20010405

Method PXARCID_AUTHORITY_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_AUTHORITY_OK Call by reference Type reference (TYPE) C Berechtigung existiert 20041220
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichtenbehandlung im iPPE 20041220
3 Importing IV_OP_ID Call by reference Type reference (TYPE) C Operation 20041220
# Exception Resumable Description Created on
1 PXARCID_AUTHORITY_CHECK_ERROR Fehler beim Ausführen der Berechtigungsprüfung 20041220

Method PXARCID_MAINT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_PXARCID Call by reference Type reference (TYPE) PPET_PXARCID_LI Archivierungsvormerkung 20041220
2 Importing IS_OBJECT Call by reference Type reference (TYPE) PPET_GUID_AENNR iPPE Objekt / Änderungsstand 20041220
3 Importing IV_APPLOBJ_TYPE Call by reference Type reference (TYPE) PPE_APPLOBJ_TYPE iPPE-Anwendungsobjekttyp 20041220
4 Importing IV_ARC_MODE Call by reference Type reference (TYPE) PPE_ARC_MODE Archivierungsstatus 20041220
5 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichtenbehandlung im IPPE 20041220
6 Importing IV_NO_EVENT Call by reference Type reference (TYPE) C PPET_TRUE Ereignis für iPPE Objekt auslösen 20041220
7 Importing IV_NO_MSG Call by reference Type reference (TYPE) C PPET_FALSE Erfolgsnachricht ? 20041220
8 Importing IV_OP_ID Call by reference Type reference (TYPE) C Operation 20041220
9 Importing IV_SENDER Call by reference Type reference (TYPE) PPET_SENDER Aufrufer 20041220
# Exception Resumable Description Created on
1 PXARCID_MAINT_ERROR Fehler bei der Pflege des Archivierungsstatus 20041220

Method SECRES_READ_BY_CRIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_AENNR Call by reference Type reference (TYPE) PPET_AENNR_TAB Änderungsstände 20030917
2 Exporting ET_PALTID Call by reference Type reference (TYPE) PPET_PALTID_LI_TAB Modus-ID's 20030917
3 Exporting ET_PAMODC Call by reference Type reference (TYPE) PPET2_PAMODC_LI_TAB Anwendungsdaten - Kapazitätsbedarfe 20030917
4 Exporting ET_PAMODD Call by reference Type reference (TYPE) PPET2_PAMODD_LI_TAB Anwendungsdaten - Zeitdauern 20030917
5 Exporting ET_SECRES Call by reference Type reference (TYPE) PPET_PNODID_LI_TAB Sekundärresourcen 20030917
6 Exporting EV_COUNT Call by reference Type reference (TYPE) I Anzahl der gefundenen Modus 20030917
7 Importing IT_AENNR_SEL Call by reference Type reference (TYPE) PPENV_AENNR_SEL_TAB Selektionstabelle mit Änderungsnummern 20030917
8 Importing IT_CHNGBY_SEL Call by reference Type reference (TYPE) PPET_CHNGBY_SEL_TAB Selektionstabelle mit Ändernden 20030917
9 Importing IT_CHNGDAT_SEL Call by reference Type reference (TYPE) PPET_CHNGDAT_SEL_TAB Selektionstabelle mit Änderungsdatum 20030917
10 Importing IT_CREABY_SEL Call by reference Type reference (TYPE) PPET_CREABY_SEL_TAB Selektionstabelle mit Anlegern 20030917
11 Importing IT_CREADAT_SEL Call by reference Type reference (TYPE) PPET_CREADAT_SEL_TAB Selektionstabelle mit Anlegedatum 20030917
12 Importing IT_MOD_LOCATION_SEL Call by reference Type reference (TYPE) PPENV_LOCID_SEL_TAB Selektionstabelle mit Moduslokationen 20030917
13 Importing IT_MOD_SEL Call by reference Type reference (TYPE) PPET_ALTNUM_SEL_TAB Selektionstabelle mit Modusnummern 20030917
14 Importing IT_SEC_RES_SEL Call by reference Type reference (TYPE) PPET2_SECRES_SEL_TAB Selektionstabelle mit Sekundärresourcen 20030917
15 Importing IV_COUNT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Nur Anzahl der Treffer bestimmen 20030917
16 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichtenbehandlung im iPPE 20030917
# Exception Resumable Description Created on
1 ERROR Allgemeiner Fehler 20030917

Method SET_ACTHD_UPDATE_TIMESTAMP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_ACTHD_UPD_TAB Call by reference Type reference (TYPE) PPET_GUID_TAB Tabelle der Arbeitsplanköpfe 20021017
2 Importing IM_APPLOBJ_TYPE Call by reference Type reference (TYPE) PVS_APPLOBJ_TYPE Anwendungsobjekttyp des iPPE 20021017
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message-Handling der iPPE-Engine 20021017

Method SET_ACTHD_UPDATE_TIMESTAMP on class CL_PPELIACT_CNTL has no exception.

Method SET_ENVIRONMENT Signature

Method SET_ENVIRONMENT on class CL_PPELIACT_CNTL has no parameter.
Method SET_ENVIRONMENT on class CL_PPELIACT_CNTL has no exception.

Method SET_HDR_UPDATE_TIMESTAMP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_APPLOBJ_TYPE Call by reference Type reference (TYPE) PVS_APPLOBJ_TYPE Application Object Type for iPPE 20010713
2 Importing IM_HDR_UPD_TAB Call by reference Type reference (TYPE) PPET_GUID_TAB Tabelle der Arbeitsplanköpfe 20021017
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in iPPE Engine 20010713

Method SET_HDR_UPDATE_TIMESTAMP on class CL_PPELIACT_CNTL has no exception.

Method SET_PNODID_UPDATE_TIMESTAMP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_APPLOBJ_TYPE Call by reference Type reference (TYPE) PVS_APPLOBJ_TYPE Anwendungsobjekttyp des iPPE 20030819
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message-Handling der iPPE-Engine 20030819
3 Importing IM_PNODID_UPD_TAB Call by reference Type reference (TYPE) PPET_GUID_TAB Tabelle der Arbeitsplanobjekte 20030819

Method SET_PNODID_UPDATE_TIMESTAMP on class CL_PPELIACT_CNTL has no exception.
Event Signatures

Event READ_ERROR Signature
Event READ_ERROR on class CL_PPELIACT_CNTL has no parameter.
History
Last changed by/on SAP  20050615 
SAP Release Created in 46C1