Hierarchy
⤷
⤷
Properties
| Class | CL_ISU_INSTALLATION | |
| Short Description | IS-U Installation | |
| Super Class | ||
| Instantiability of a Class | 0 | Private |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | EEPDSC1 | IS-U: Master Data Generator |
| Created | 20000419 | SAP |
| Last change | 20070914 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) | |
| 2 | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) | |
| 3 | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) | |
| 4 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 5 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 6 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_ISU_INSTALLATION has no interface implemented.
Friends
Class CL_ISU_INSTALLATION has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Instance attribute | Public | Type reference (TYPE) | EANL-ANLAGE | INSTALLATIONID | 20000419 | |||
| 2 | Instance attribute | Public | Type reference (TYPE) | INT_UI | Internal key for point of delivery | 20000908 | |||
| 3 | Instance attribute | Private | Type reference (TYPE) | ISU01_INSTLN_AUTO | P_AUTO | 20000419 | |||
| 4 | Instance attribute | Private | Type reference (TYPE) | ISU_INST_CONTROL_TYPE | Control Data | 20000419 | |||
| 5 | Instance attribute | Private | Type reference (TYPE) | EANL-SPARTE | P_CREA_SPART | 20000419 | |||
| 6 | Instance attribute | Private | Object reference (TYPE REF TO) | ISU01_INSTLN | Reference to ISU01_INSTLN | 20030620 | |||
| 7 | Instance attribute | Private | Type reference (TYPE) | EANL | P_EANL | 20000419 | |||
| 8 | Instance attribute | Private | Type reference (TYPE) | ISU06_T_EANLH | P_EANLH | 20000419 | |||
| 9 | Instance attribute | Private | Type reference (TYPE) | IEUIINSTLN | Allocation of Installation to Point of Delivery | 20000727 | |||
| 10 | Instance attribute | Private | Type reference (TYPE) | ISU20_INSTLN_FACTS_AUTO | isu20_instln_facts_auto | 20000419 | |||
| 11 | Static Attribute | Private | Type reference (TYPE) | ISU_T_INSTLN_INSTANCE | Tabelle for structure isu_contract_instance | 20000419 | |||
| 12 | Instance attribute | Private | Type reference (TYPE) | EANL-ANLAGE | P_KEY | 20000419 | |||
| 13 | Instance attribute | Private | Type reference (TYPE) | TY_REFVAL | Initialize a New Reference Value | 20000726 | |||
| 14 | Instance attribute | Private | Type reference (TYPE) | EUI_EXT_OBJ_AUTO | Automation data for external UI object | 20000727 | |||
| 15 | Instance attribute | Private | Type reference (TYPE) | TABIX | For set_property_refvalue_tre | 20000801 |
Methods
Events
Class CL_ISU_INSTALLATION has no event.
Types
| # | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
|---|---|---|---|---|---|---|---|
| 1 | TY_REFVAL | Private | See coding | 20000726 | |
Method Signatures
Method CHANGE_PRORATION_DATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_NEW_DATE | Call by reference | Type reference (TYPE) | D | X_NEW_DATE | 20000419 | |||
| 2 | X_OLD_DATE | Call by reference | Type reference (TYPE) | D | X_OLD_DATE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_DATE | 20000419 | ||
| 2 | NOT_OPEN | 20000419 |
Method CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_FROMDATE | Call by reference | Type reference (TYPE) | FROMDATE | Gültig ab Datum | 20010820 | |||
| 2 | X_TODATE | Call by reference | Type reference (TYPE) | TODATE | Gültig bis Datum | 20010820 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | FAILED | 20000419 | ||
| 2 | NOT_OPEN | 20000419 |
Method CLOSE Signature
Method CLOSE on class CL_ISU_INSTALLATION has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | NOT_OPEN | 20000419 |
Method CREATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DIVISIONID | Call by reference | Type reference (TYPE) | EANL-SPARTE | DIVISIONID | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | NOT_SELECTED | 20000419 | ||
| 2 | OBJECT_INVALID | 20000419 |
Method FILL_FACTS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_FACTS | Call by reference | Type reference (TYPE) | ISU20_INSTLN_FACTS_AUTO | X_FACTS | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | NOT_SELECTED | 20000419 |
Method FILL_POD Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_POD | Call by reference | Type reference (TYPE) | EUI_EXT_OBJ_AUTO | Automation data for external UI object | 20000727 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | NOT_SELECTED | 20000727 |
Method FILL_WORKAREA Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_EANL | Call by reference | Type reference (TYPE) | EANL | X_EANL | 20000419 | |||
| 2 | X_EANLH | Call by reference | Type reference (TYPE) | ISU06_T_EANLH | X_EANLH | 20000419 | |||
| 3 | X_EUIINSTLN | Call by reference | Type reference (TYPE) | IEUIINSTLN | Zuordnung Anlage zu Unique Identifier | 20000727 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | NOT_SELECTED | 20000419 |
Method FREE_ALL Signature
Method FREE_ALL on class CL_ISU_INSTALLATION has no parameter.
Method FREE_ALL on class CL_ISU_INSTALLATION has no exception.
Method GET_ALL_PROPERTIES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_KEYDATE | Call by reference | Type reference (TYPE) | D | X_KEYDATE | 20000419 | |||
| 2 | Y_EUIINSTLN | Call by reference | Type reference (TYPE) | EUIINSTLN | Y_EUIINSTLN | 20000727 | |||
| 3 | Y_FACTS | Call by reference | Type reference (TYPE) | ISU20_INSTLN_FACTS_AUTO | Automationsdaten Anlagefakten | 20020318 | |||
| 4 | Y_V_EANL | Call by reference | Type reference (TYPE) | V_EANL | Y_V_EANL | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | INVALID_PROPERTY | 20000419 | ||
| 3 | KEYDATE_INVALID | 20000419 | ||
| 4 | NOT_SELECTED | 20000419 |
Method GET_ELIGIBILITY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Y_ELIG_STATUS | Call by reference | Type reference (TYPE) | EANL-DEREGSTAT | Y_ELIG_STATUS | 20000419 | |||
| 2 | Y_ENROLLABLE | Call by reference | Type reference (TYPE) | TEDEREGSTAT-ENROLLABLE | Y_ENROLLABLE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | NOT_SELECTED | 20000419 |
Method GET_HISTORICAL_PROPERTY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_KEYDATE | Call by reference | Type reference (TYPE) | D | X_KEYDATE | 20000419 | |||
| 2 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000419 | |||
| 3 | Y_VALUE | Call by reference | Type reference (TYPE) | ANY | Y_VALUE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | INVALID_PROPERTY | 20000419 | ||
| 3 | KEYDATE_INVALID | 20000419 | ||
| 4 | NOT_CONVERTABLE | 20000419 | ||
| 5 | NOT_SELECTED | 20000419 | ||
| 6 | PROPERTY_NOT_FOUND | 20000419 |
Method GET_NEXT_METERREAD_DATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_KEYDATE | Call by reference | Type reference (TYPE) | D | X_KEYDATE | 20000419 | |||
| 2 | Y_MR_DATE | Call by reference | Type reference (TYPE) | D | Y_MR_DATE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | KEYDATE_INVALID | 20000419 | ||
| 3 | NOT_FOUND | 20000419 | ||
| 4 | NOT_SELECTED | 20000419 |
Method GET_PREMISES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Y_PREMISES | Value transfer | Object reference (TYPE REF TO) | CL_ISU_PREMISE | Y_PREMISES | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | NOT_SELECTED | 20000419 |
Method GET_PROPERTY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000419 | |||
| 2 | Y_VALUE | Call by reference | Type reference (TYPE) | ANY | Y_VALUE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | INVALID_PROPERTY | 20000419 | ||
| 3 | NOT_CONVERTABLE | 20000419 | ||
| 4 | NOT_SELECTED | 20000419 |
Method INIT_NEW_REFVAL_FOR_OPERAND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_AB | Call by reference | Type reference (TYPE) | ABZEITSCH | Datum, ab dem eine Zeitscheibe gültig ist | 20000726 | |||
| 2 | X_OPERAND | Call by reference | Type reference (TYPE) | E_OPERAND | Operand | 20000726 |
Method INIT_NEW_REFVAL_FOR_OPERAND on class CL_ISU_INSTALLATION has no exception.
Method LOAD Signature
Method LOAD on class CL_ISU_INSTALLATION has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | NOT_SELECTED | 20000419 |
Method OPEN Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_CRM_RELATED | Call by reference | Type reference (TYPE) | KENNZX | Kennzeichen | 20010326 | |||
| 2 | X_KEYDATE | Call by reference | Type reference (TYPE) | D | X_KEYDATE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | LOCKED | 20000419 | ||
| 2 | NOT_AUTHORIZED | 20000419 | ||
| 3 | NOT_SELECTED | 20000419 | ||
| 4 | OBJECT_INVALID | 20000419 | ||
| 5 | SYSTEM_ERROR | 20000419 |
Method SAVE Signature
Method SAVE on class CL_ISU_INSTALLATION has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | NOT_OPEN | 20000419 | ||
| 2 | SYSTEM_ERROR | 20000419 |
Method SELECT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | INSTALLATION | Value transfer | Object reference (TYPE REF TO) | CL_ISU_INSTALLATION | INSTALLATION | 20000419 | |||
| 2 | INSTALLATIONID | Call by reference | Type reference (TYPE) | EANL-ANLAGE | INSTALLATIONID | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 |
Method SELECT_BY_INTERNAL_POD Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | INSTALLATIONS | Value transfer | Type reference (TYPE) | ISU_REF_INSTALLATION_TAB | Tabelle von Anlagereferenzen | 20000727 | |||
| 2 | X_INT_UI | Call by reference | Type reference (TYPE) | INT_UI | Interner Schlüssel des Versorgungspunkts | 20000727 | |||
| 3 | X_KEYDATE | Call by reference | Type reference (TYPE) | D | Datum im CHAR-Format | 20000727 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000727 | ||
| 2 | OBJECT_NOT_FOUND | 20000727 |
Method SELECT_PREMISEID_DIVISIONID Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DIVISIONID | Call by reference | Type reference (TYPE) | EANL-SPARTE | DIVISIONID | 20000419 | |||
| 2 | INSTALLATIONS | Value transfer | Type reference (TYPE) | ISU_REF_INSTALLATION_TAB | INSTALLATIONS | 20000419 | |||
| 3 | PREMISEID | Call by reference | Type reference (TYPE) | EANL-VSTELLE | PREMISEID | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20000419 | ||
| 2 | OBJECT_NOT_FOUND | 20000419 |
Method SET_ALL_PROPERTIES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_EUIINSTLN | Call by reference | Type reference (TYPE) | EUIINSTLN | Zählpunktzuordnung | 20010221 | |||
| 2 | X_FACTS | Call by reference | Type reference (TYPE) | ISU20_INSTLN_FACTS_AUTO | Automationsdaten Anlagefakten | 20020318 | |||
| 3 | X_KEYDATE | Call by reference | Type reference (TYPE) | D | Datum | 20010221 | |||
| 4 | X_V_EANL | Call by reference | Type reference (TYPE) | V_EANL | Anlagendaten | 20010221 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_OBJECT | 20010221 | ||
| 2 | INVALID_PROPERTY | 20010221 | ||
| 3 | KEYDATE_INVALID | 20010221 | ||
| 4 | NOT_SELECTED | 20010221 |
Method SET_HISTORICAL_PROPERTY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_KEYDATE | Call by reference | Type reference (TYPE) | D | X_KEYDATE | 20000419 | |||
| 2 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000419 | |||
| 3 | X_TODATE | Call by reference | Type reference (TYPE) | D | CL_ISU_DATE=>CO_DATE_INFINITE | Bis-Datum | 20010225 | ||
| 4 | X_VALUE | Call by reference | Type reference (TYPE) | ANY | X_VALUE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20000419 | ||
| 2 | INVALID_VALUE | 20000419 | ||
| 3 | NOT_OPEN | 20000419 |
Method SET_PROPERTY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000419 | |||
| 2 | X_VALUE | Call by reference | Type reference (TYPE) | ANY | X_VALUE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20000419 | ||
| 2 | INVALID_VALUE | 20000419 | ||
| 3 | NOT_OPEN | 20000419 |
Method SET_PROPERTY_FACT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_AB | Call by reference | Type reference (TYPE) | ABZEITSCH | X_AB | 20000419 | |||
| 2 | X_DELETE | Call by reference | Type reference (TYPE) | AUTO_DELETE | X_DELETE | 20061013 | |||
| 3 | X_MERGE | Call by reference | Type reference (TYPE) | AUTO_MERGE | X_MERGE | 20041124 | |||
| 4 | X_OPERAND | Call by reference | Type reference (TYPE) | E_OPERAND | X_OPERAND | 20000419 | |||
| 5 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000419 | |||
| 6 | X_SAISON | Call by reference | Type reference (TYPE) | SAISON | X_SAISON | 20000419 | |||
| 7 | X_VALUE | Call by reference | Type reference (TYPE) | ANY | X_VALUE | 20000419 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20000419 | ||
| 2 | INVALID_VALUE | 20000419 | ||
| 3 | NOT_OPEN | 20000419 | ||
| 4 | SYSTEM_ERROR | 20000419 |
Method SET_PROPERTY_POD Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_AB | Value transfer | Type reference (TYPE) | ABZEITSCH | Datum, ab dem eine Zeitscheibe gültig ist | 20000727 | |||
| 2 | X_PROPERTY | Value transfer | Type reference (TYPE) | C | Feldname | 20000719 | |||
| 3 | X_VALUE | Value transfer | Type reference (TYPE) | ANY | Feldwert | 20000719 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20000719 | ||
| 2 | INVALID_VALUE | 20000719 | ||
| 3 | NOT_OPEN | 20000719 |
Method SET_PROPERTY_REFVALUE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_OPERAND | Call by reference | Type reference (TYPE) | E_OPERAND | X_OPERAND | 20000726 | |||
| 2 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000726 | |||
| 3 | X_SUPPRESS | Call by reference | Type reference (TYPE) | AUTO_MERGE | Automationsdaten zusammenführen | 20050908 | |||
| 4 | X_VALUE | Call by reference | Type reference (TYPE) | ANY | X_VALUE | 20000726 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20000726 | ||
| 2 | INVALID_VALUE | 20000726 | ||
| 3 | NOT_INITIALIZED | 20000726 | ||
| 4 | NOT_OPEN | 20000726 | ||
| 5 | SYSTEM_ERROR | 20000726 |
Method SET_PROPERTY_REFVALUE_OPM Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_BETRART | Call by reference | Type reference (TYPE) | BETRART | Betriebsart der Beleuchtung | 20000801 | |||
| 2 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000801 | |||
| 3 | X_VALUE | Call by reference | Type reference (TYPE) | ANY | X_VALUE | 20000801 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20000801 | ||
| 2 | INVALID_VALUE | 20000801 | ||
| 3 | NOT_INITIALIZED | 20000801 | ||
| 4 | NOT_OPEN | 20000801 | ||
| 5 | SYSTEM_ERROR | 20000801 |
Method SET_PROPERTY_REFVALUE_SERVFREQ Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20010208 | |||
| 2 | X_VALUE | Call by reference | Type reference (TYPE) | ANY | X_VALUE | 20010208 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20010208 | ||
| 2 | INVALID_VALUE | 20010208 | ||
| 3 | NOT_INITIALIZED | 20010208 | ||
| 4 | NOT_OPEN | 20010208 | ||
| 5 | SYSTEM_ERROR | 20010208 |
Method SET_PROPERTY_REFVALUE_TRE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | X_NEW_TRE | Call by reference | Type reference (TYPE) | BOOLE-BOOLE | Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') | 20000801 | |||
| 2 | X_PROPERTY | Call by reference | Type reference (TYPE) | C | X_PROPERTY | 20000801 | |||
| 3 | X_VALUE | Call by reference | Type reference (TYPE) | ANY | X_VALUE | 20000801 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | INVALID_PROPERTY | 20000801 | ||
| 2 | INVALID_VALUE | 20000801 | ||
| 3 | NOT_INITIALIZED | 20000801 | ||
| 4 | NOT_OPEN | 20000801 | ||
| 5 | SYSTEM_ERROR | 20000801 |
History
| Last changed by/on | SAP | 20070914 |
| SAP Release Created in | 462 |