SAP ABAP Class CL_ISU_EDM_SETTLSTEP_0006 (EDM Settlement Step: SumSUAll)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷ IS-U-EDM (Application Component) Energy Data Management
⤷ EE_EDM_SET (Package) EDM Settlement
⤷ IS-U-EDM (Application Component) Energy Data Management
⤷ EE_EDM_SET (Package) EDM Settlement
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_ISU_EDM_SETTLSTEP_0001 | EDM Settlement Step: General Methods | 20010312 |
Properties
Class | CL_ISU_EDM_SETTLSTEP_0006 | |
Short Description | EDM Settlement Step: SumSUAll | |
Super Class | CL_ISU_EDM_SETTLSTEP_0001 | EDM Settlement Step: General Methods |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | P | SAP Standard Production Program |
Category | 0 | |
Package | EE_EDM_SET | EDM Settlement |
Created | 20010220 | SAP |
Last change | 20050224 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_ISU_EDM_SETTLSTEP_0006 has no forward declaration.
Interfaces
Class CL_ISU_EDM_SETTLSTEP_0006 has no interface implemented.
Friends
Class CL_ISU_EDM_SETTLSTEP_0006 has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | CO_PARNUMBER_INPUT | Constant | Private | Type reference (TYPE) | EPARNUMBER | '01' | Parameter Number | 20010313 | |
2 | CO_PARNUMBER_RESULT | Constant | Private | Type reference (TYPE) | EPARNUMBER | '01' | Parameter Number | 20010312 | |
3 | LOCAL_FROM | Instance attribute | Private | Type reference (TYPE) | EEDMDATEFROM | Structure for From-Date | 20010313 | ||
4 | LOCAL_TO | Instance attribute | Private | Type reference (TYPE) | EEDMDATETO | Structure for To-Date | 20010313 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | GET_SUBUNITS | Instance method | Private | Method | Determines all Subsettlement Units of Top Unit | 20010308 |
2 | GET_TOPUNITS | Instance method | Protected | Method | Determines Which Settlement Units are Top Units | 20010308 |
3 | READ_SETTLUNIT_DATA | Instance method | Private | Method | Read Input Parameters and Associated Profile Values | 20010312 |
4 | WRITE_LOG | Instance method | Protected | Method | Write Information to Settlement Log | 20010313 |
Events
Class CL_ISU_EDM_SETTLSTEP_0006 has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | TPT_INFO | Protected | See coding | Table for Additional Log Data | 20010313 |
|
|
2 | TP_INFO | Protected | See coding | Additional Log Data | 20010313 |
|
Method Signatures
Method GET_SUBUNITS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | X_TOPUNIT | Call by reference | Type reference (TYPE) | E_EDMSETTLUNIT | Bilanzierungseinheit | 20010308 | ||
2 | Returning | YT_SUBUNIT | Value transfer | Type reference (TYPE) | T_SETTLUNIT | Liste von untergeordneten Bilanzierungseinheiten | 20010308 |
Method GET_SUBUNITS on class CL_ISU_EDM_SETTLSTEP_0006 has no exception.
Method GET_TOPUNITS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | X_INSTANCE_DATA | Call by reference | Type reference (TYPE) | EEDMSETTLSTEP_DATA | Instanzdaten im Bilanzierungsschritt | 20010308 | ||
2 | Returning | YT_TOPSETTLUNIT | Value transfer | Type reference (TYPE) | T_SETTLUNIT | Liste von Bilanzierungseinheiten | 20010308 |
Method GET_TOPUNITS on class CL_ISU_EDM_SETTLSTEP_0006 has no exception.
Method READ_SETTLUNIT_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | XT_PROFILE | Call by reference | Type reference (TYPE) | TPT_PROFILE | Inputprofile | 20010312 | ||
2 | Importing | X_INSTANCE_DATA | Call by reference | Type reference (TYPE) | EEDMSETTLSTEP_DATA | Instanzdaten im Bilanzierungsschritt | 20010312 | ||
3 | Importing | X_SETTLUNIT | Call by reference | Type reference (TYPE) | E_EDMSETTLUNIT | Bilanzierungseinheit | 20010312 | ||
4 | Exporting | Y_SETTLUNIT_DATA | Call by reference | Object reference (TYPE REF TO) | IF_ISU_EDM_PROFILE_DATA | Interface für EDM-Profil - Datenteil | 20010312 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR_OCCURRED | Fehler beim Lesen der Daten | 20010312 | |
2 | NOT_FOUND | Parameter zur Bilanzierungseinheit icht gefunden | 20010312 |
Method WRITE_LOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | XT_INFO | Call by reference | Type reference (TYPE) | TPT_INFO | Loginformation | 20010313 | ||
2 | Importing | X_INSTANCE_DATA | Call by reference | Type reference (TYPE) | EEDMSETTLSTEP_DATA | Instanzdaten im Bilanzierungsschritt | 20010313 |
Method WRITE_LOG on class CL_ISU_EDM_SETTLSTEP_0006 has no exception.
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in | 463 |