SAP ABAP Class CL_ISU_EDM_FORMULA_INSTANCE (EDM Formula Instance)
Hierarchy
IS-UT (Software Component) SAP Utilities/Telecommunication
   IS-U-EDM (Application Component) Energy Data Management
     EE_EDM_PRO (Package) Profile Management
Properties
Class CL_ISU_EDM_FORMULA_INSTANCE  
Short Description EDM Formula Instance    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package EE_EDM_PRO   Profile Management 
Created 20000502   SAP 
Last change 20091125   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class CL_ISU_EDM_FORMULA_INSTANCE has no forward declaration.
Interfaces
Class CL_ISU_EDM_FORMULA_INSTANCE has no interface implemented.
Friends
Class CL_ISU_EDM_FORMULA_INSTANCE has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 BUF_INPUT_PARAMETER Static Attribute Private Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Input Parameters for Formula Instance (Int. Table) 20110228
2 BUF_OUTPUT_PARAMETER Static Attribute Private Type reference (TYPE) TEFORMULAINSTPARAM_O ISU EDM Output Parameters for Formula Inst. (Int. Tabelle) 20110228
3 CHANGE_CALC_INSTANCE Instance attribute Public Type reference (TYPE) KENNZX ' ' Indicator 20031016
4 CO_AUTH_CALC Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'CALC' Authorization for Asynchronous Calculation 20000707
5 CO_AUTH_CALCS Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'CALCS' Authorization for Synchronous Calculation 20001115
6 CO_AUTH_CHANG Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'CHANG' Authorization for Changing Formula Allocation 20020424
7 CO_AUTH_COMPR Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'COMPR' Authorization for Trigger Compression 20000707
8 CO_AUTH_CRDEL Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'CRDEL' Authorization for Deleting Control Data 20050202
9 CO_AUTH_STATE Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'STATE' Authorization for Status Change 20000707
10 CO_AUTH_TRIGG Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'TRIGG' Write Authorization for Manual Trigger 20000804
11 CO_AUTH_TRIGG_DEL Constant Public Type reference (TYPE) E_AUTH_CALCULATE_STATE 'TRDEL' Authorization for Deleting Authorization Triggers 20020510
12 CO_CALC_NR_OBJECT Constant Public Type reference (TYPE) INRI-OBJECT 'ISU_EDM_CR' Number Range Object for Calculation Run 20000613
13 CO_CHANGE_MODE Constant Public Type reference (TYPE) REGEN-WMODE '2' Change Mode 20000623
14 CO_CREATE_MODE Constant Public Type reference (TYPE) REGEN-WMODE '3' Creation Mode 20000623
15 CO_DATE_MAX Constant Public Type reference (TYPE) E_EDMDATETO '99991231' Date High Value 20000504
16 CO_DATE_MIN Constant Public Type reference (TYPE) E_EDMDATEFROM '00010101' Date Low Value 20000504
17 CO_DISPLAY_MODE Constant Public Type reference (TYPE) REGEN-WMODE '1' Display mode 20000623
18 CO_ENQ_ATTEMPTS Constant Private Type reference (TYPE) E_ENQ_ATTEMPTS 100 Number of Lock Attempts for Interval 20000519
19 CO_ERROR_TYPE_FOLLOWING Constant Public Type reference (TYPE) E_ERROR_TYPE 'F' Error Type : Subsequent Error 20010102
20 CO_ERROR_TYPE_TEMPORARY Constant Public Type reference (TYPE) E_ERROR_TYPE 'T' Error Type: Temporary 20010102
21 CO_INPPAR Constant Private Type reference (TYPE) EPARTYPE 1 Type of Formula Parameter 20000628
22 CO_INSTANCE_NUM_OBJ Constant Public Type reference (TYPE) INRI-OBJECT 'ISU_EDM_FI' Number Range Object for Formula Instance 20000623
23 CO_JOBNAME_DISPATCH Constant Public Type reference (TYPE) TBTCO-JOBNAME 'EEDM_CALC_DISP' Job Name Dispatcher 20000522
24 CO_JOBNAME_EXECUTE Constant Public Type reference (TYPE) TBTCO-JOBNAME 'EEDM_CALC_EXEC' Job Name Calculation 20000522
25 CO_JOBNAME_SET_CALC Constant Public Type reference (TYPE) TBTCO-JOBNAME 'EEDM_CALC_SET' Background Job Name 20011109
26 CO_LOCK_OBJECT_CALCULATION Constant Public Type reference (TYPE) E_LOCK_OBJECT 'INSTANCE_CALCULATION' EDM Lock Object (Formula Instance Calculation) 20000608
27 CO_LOCK_OBJECT_TRIGGER_COMPR Constant Public Type reference (TYPE) E_LOCK_OBJECT 'TRIGGER_COMPRESSION' EDM Lock Object (Formula Instance Calculation) 20000608
28 CO_MAX_INST_CALC_SYNC Constant Public Type reference (TYPE) SYST-TMAXL 5 Maximum Number of Synchronous Calculations 20010131
29 CO_NO_TRIGGER_CREATION Constant Public Type reference (TYPE) E_FL_TRIGGER 'X' Does Not Trigger Calculation 20010118
30 CO_OUTPAR Constant Private Type reference (TYPE) EPARTYPE 2 Type of Formula Parameter 20000628
31 CO_PARTYPE_INPUT Constant Public Type reference (TYPE) EPARTYPE 1 Entry of Formula Parameter Type 20000525
32 CO_PARTYPE_OUTPUT Constant Public Type reference (TYPE) EPARTYPE 2 Output of Formula Parameter Type 20000525
33 CO_STAT_INST_CALC Constant Public Type reference (TYPE) E_STAT_INST ' ' Status of Formula Instance Calculation 20001215
34 CO_STAT_INST_ERROR Constant Public Type reference (TYPE) E_STAT_INST 'E' Status of Formula Instance Calculation 20000615
35 CO_STAT_INST_SUCCESS Constant Public Type reference (TYPE) E_STAT_INST 'S' Status of Formula Instance Calculation 20000615
36 CO_TIME_MAX Constant Public Type reference (TYPE) E_EDMTIMETO '235959' Time High Value 20000504
37 CO_TIME_MIN Constant Public Type reference (TYPE) E_EDMTIMEFROM '000000' Time Low Value 20000504
38 FORMULAINSTANCE Instance attribute Private Type reference (TYPE) EFORMULAINSTANCE IS-U EDM Formula Instance 20000502
39 HEADER_DATA Instance attribute Public Type reference (TYPE) EFORMULAINST_DATA ISU EDM Data fields for Header of Formula Instance 20000510
40 INPUT_PARAMETER Instance attribute Public Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Input Parameters for Formula Instance (Int. Table) 20000510
41 INSTANCE_CLOSED Instance attribute Public Type reference (TYPE) KENNZX 'X' Formula Instance Is closed 20000502
42 INSTANCE_IS_CHECKED Instance attribute Private Type reference (TYPE) BOOLE-BOOLE Instance Checked 20000725
43 INSTANCE_NUMBER Instance attribute Public Type reference (TYPE) E_INSTANCE_NUMBER Formula Instance 20000503
44 NR_EXTINTKZ Instance attribute Private Type reference (TYPE) EXTINTKZ External or Internal Number Assignment 20000623
45 OK_FOR_UPDATE Instance attribute Private Type reference (TYPE) BOOLE-BOOLE Preparation Successful, Update Necessary 20000718
46 OUTPUT_PARAMETER Instance attribute Public Type reference (TYPE) TEFORMULAINSTPARAM_O ISU EDM Output Parameters for Formula Inst. (Int. Tabelle) 20000510
47 SCREEN_CALCNR Static Attribute Public Type reference (TYPE) E_CALCNR_OUTPUT Calculation run number 20010222
48 SCREEN_FROM Static Attribute Public Type reference (TYPE) EEDMDATEFORSCREEN IS-U-EDM: Date/Time for Screen Output (Structure) 20000726
49 SCREEN_INSTANCE_NUMBER Static Attribute Public Type reference (TYPE) E_INSTANCE_NUMBER_OUTPUT Number of Formula Allocation 20010214
50 SCREEN_TO Static Attribute Public Type reference (TYPE) EEDMDATEFORSCREEN IS-U-EDM: Date/Time for Screen Output (Structure) 20000726
51 SEL_FROM Instance attribute Private Type reference (TYPE) EEDMDATEFROM From Date from OPEN 20000623
52 SEL_TO Instance attribute Private Type reference (TYPE) EEDMDATETO To Date from Open 20000623
53 TRIGGER_FOR_CHANGES Instance attribute Public Type reference (TYPE) TEEDM_DATE_TIME_FROM_TO_UTC Periods for Trigger Slices of Changes 20001016
54 TRIGGER_NEW Instance attribute Private Type reference (TYPE) TEFORMULATRIGGER_NEW ISU EDM: New, Compressed Trigger Records (Internal Usage) 20000516
55 UPDATE_DONE Instance attribute Private Type reference (TYPE) BOOLE-BOOLE Update Executed 20000718
56 UPD_ONLINE Instance attribute Public Type reference (TYPE) REGEN-UPD_ONLINE Update Mode 20000502
57 WORK_MODE Instance attribute Public Type reference (TYPE) REGEN-WMODE Processing Mode 20000502
Methods
# Method Level Visibility Method type Description Created on
1 ADD_OFFSETDATE_TO_DATE Static method Public Method Add Offset Date to Date and Time 20000711
2 ADD_SECOND Static method Public Method Add Second to Event 20000728
3 ASYNCHRON_CALC_EXECUTE Instance method Public Method Asychronous Calculation: Execute per Interval (Commit) 20000519
4 ASYNCHRON_CALC_INTERVALS Instance method Public Method Asynchronous Calc. for Interval Subdivision (Incl. Commit) 20000523
5 ASYNCHRON_CALC_PREPARE Instance method Public Method Asynchronous Calc. for Hierarchy Creation (Including Commit) 20000519
6 BUILD_JOBNAME Static method Public Method Creation of Job Name 20000525
7 BUILD_TIMESLOTS_IN_INTERVALS Static method Public Method Determine Several Time Slices of Several Intervals 20000524
8 BUILD_TIMESLOTS_IN_PARAMETER Instance method Public Method Determine Time Slices of Parameter Allocations 20000627
9 CALCULATE Instance method Public Method Calculation of Formula Instance 20000523
10 CALCULATE_OFFSET Static method Public Method Calculation of Period from Offset Number 20000710
11 CALC_MSG_DISPLAY Static method Public Method Display messages for synchronous calculation 20010131
12 CALC_MSG_OPEN Static method Public Method Open messages for synchronous calculation 20010131
13 CALC_TIMESLOT_OF_INTERVAL Static method Public Method Proration of Validity in Interval 20000510
14 CHECK_COMPLETENESS Instance method Public Method Check Completeness 20000721
15 CHECK_CONTINUOUSLY Instance method Public Method Check Time Slices for Gaps 20000627
16 CHECK_IF_INSTANCE_IS_ACTIVE Static method Public Method Check Whether Formula Instance Must Be Recalculated 20000517
17 CHECK_IF_JOB_IS_ACTIVE Static method Public Method Check Whether Calculation Program is Running 20000707
18 CLOSE Instance method Public Method Close Formula Instance (For Maintenance) 20000502
19 COMPRESS_ACTION Instance method Public Method Compress Date and Time of Interval to Intervals 20000530
20 COMPRESS_STATUS Instance method Public Method Compress Date and Time of Status to Intervals 20000530
21 COMPRESS_TRIGGER Instance method Public Method Compress Temporary Trigger File (Including Commit) 20000516
22 CONVERT_LTC_TIME_TO_UTC Static method Public Method Convert LTC Time to UTC Time 20000911
23 CONVERT_UTC_TIME_TO_LTC Static method Public Method Convert LTC Time to UTC Time 20000911
24 COPY_PROFILE Instance method Public Method Create Profile Copy from Output Profile 20031112
25 CREATE Instance method Public Method Creation of New Formula Instance (For Maintenance) 20000504
26 CREATE_INTERVALS Instance method Public Method Creation of Interval for Consecutive Number 20000519
27 CREATE_TRIGGER_FOR_INSTANCE Static method Public Method Write Trigger File for Instance Number from Calculation 20000613
28 CREATE_TRIGGER_FOR_PROFILE Static method Public Method Write Trigger File Based on Profile Number 20000510
29 DELETE_INTERVALS Instance method Public Method Delete All Intervals of a Calculation Run Number 20000628
30 DELETE_INTERV_FROM_INTERV Static method Public Method Delete Time Slice from Several Intervals 20001219
31 DELETE_TMP_TRIGGER_CALC Static method Public Method Delete Temporary Trigger Records from Calculation 20000627
32 DISPLAY_CALCULATION_ERRORS Static method Public Method Display Calculations with Errors 20001011
33 DISPLAY_FORMULAINSTANCE Static method Public Method Display Formula Allocation 20010215
34 GET_CRITICAL_DATE_TIME Static method Public Method Critical Times for Summer and Winter Time Change 20060724
35 GET_IMPORTPARAMETER Instance method Public Method Original Import Parameter 20000725
36 GET_INP_PARAM_LOW_FROM_HIGH_TO Instance method Public Method Determine Earliest From Date and Latest To Date (Inp. Param) 20000718
37 GET_INSTANCE_HIERARCHY_DOWN Static method Public Method Hierarchy Expansion for Formula Instance (Triggering) 20000530
38 GET_INSTANCE_HIERARCHY_UP Static method Public Method Hierarchy Expansion for Formula Instance (Dependent) 20000504
39 GET_INSTANCE_OF_PROFILE_INPUT Static method Public Method Read Instances of Profile Number as Input Parameter 20000510
40 GET_INSTANCE_OF_PROFILE_OUTPUT Static method Public Method Read Instances of Profile Number as Output Parameter 20000510
41 GET_LAST_CALCULATION_RUN Static method Public Method Read Control Data of Last Calculation 20000619
42 GET_MAX_OFFSET_FOR_HIER Static method Public Method Calculate Largest Offset of Formula Instance for Hierarchy 20000711
43 GET_MAX_TIMESLOTS_LEVELS Instance method Public Method Determine Maximum Time Slices and Hierarchy Levels 20000628
44 GET_NEXT_HIERARCHY_LEVEL Static method Public Method Determine Subsequent Hierarchy Levels (Dependent) 20000515
45 GET_NEXT_TIMESLOT_FOR_DISPATCH Instance method Public Method Deternine Next Time Slice or Hierarchy Level 20000525
46 GET_PREV_HIERARCHY_LEVEL Static method Public Method Determine Previous Hierarchy Levels (Triggering) 20000515
47 LCL_ADJUST_INTERVAL_LENGHT Instance method Private Method Adjust Hierarchy Time Slices to Interval Length 20100705
48 LCL_BUILD_TIMESLOTS_IN_INTERVL Static method Private Method Determine Several Time Slices of Several Intervals (Int.) 20000524
49 LCL_BUILD_TIMESLOTS_IN_PARA Instance method Private Method Determine Several Time Slices of Several Intervals (Int.) 20000627
50 LCL_CALCULATE Instance method Private Method Calculation of Formula Instance (Internal Function) 20000523
51 LCL_CALCULATE_SYNCHRON Instance method Private Method Synchronous Calculation for Formula Allocation 20001115
52 LCL_COMPRESS_TRIGGER Instance method Private Method Compress Trigger Records 20000516
53 LCL_CONVERT_AND_UPDATE_RESULT Instance method Private Method Convert Result Data and Update Profile 20000530
54 LCL_CREATE_HIERARCHY_TABLE Instance method Private Method Create Hierarchy Table for Asynchronous Calculation 20000616
55 LCL_CREATE_NEW_STATUS Instance method Private Method Determine Status for Output Parameters of Formulas 20000529
56 LCL_DELETE_INTERV_FROM_INTERV Static method Public Method Delete Interval from Other Interval 20001219
57 LCL_DELETE_KMP_TRIGGER_IN_USE Static method Private Method Delete Compressed Trigger File in Processing 20000613
58 LCL_DELETE_OLD_KMP_TRIGGER Instance method Private Method Delete Old Compressed Trigger Records on DB 20000516
59 LCL_DELETE_OLD_TMP_TRIGGER Instance method Private Method Delete Old Temporary Trigger Records on DB 20000516
60 LCL_GET_NEXT_INTERVAL Instance method Private Method Get Next Free Interval (Commit Work) 20000519
61 LCL_INIT_ATTRIBUTES Instance method Private Method Initialize Class Attributes 20000517
62 LCL_INSERT_HIERARCHY_IN_DB Instance method Private Method Insert New Hierarchy in Table EFORMULAHIER 20000519
63 LCL_INSERT_INTERVALS Instance method Private Method Write Intervals to Database 20000519
64 LCL_INSERT_KMP_TRIGGER Instance method Private Method Write Compressed Trigger Records to Database 20000516
65 LCL_INSERT_KMP_TRIGGER_PREPARE Instance method Private Method Prepare to Insert Compressed Trigger File 20000518
66 LCL_INSERT_NEW_CALCULATION_RUN Instance method Private Method Create New Control Data of Calculation Run 20000619
67 LCL_INSERT_TMP_TRIGGER Static method Private Method Write Temporary Trigger Records to DB 20000516
68 LCL_INTERVAL_CALCULATE Instance method Private Method Calculation of Interval of Hierarchy Level 20000523
69 LCL_INTERVAL_CONFIRM Instance method Private Method Confirm Interval and Check Whether All Complete (Commit) 20000519
70 LCL_LOCK_INTERVAL Instance method Private Method Lock Interval Processing 20000519
71 LCL_MERGE_TRIGGER Instance method Private Method Merge Trigger Records 20000516
72 LCL_RESET_HIERARCHY_TABLE Instance method Private Method Reset Hierarchy Table for Restart 20000627
73 LCL_SET_STATUS_CALC_DETAIL Instance method Private Method Set Status of Calculation of Formula Instance 20000615
74 LCL_UNLOCK_INTERVAL Instance method Private Method Unlock Interval Processing 20000519
75 LCL_UPDATE_KMP_TRIGGER_IN_USE Instance method Private Method Set Processing Indicator in Compressed Trigger File 20000518
76 LOCK_CALCULATION Static method Public Method Set Lock of Formula Instance Calculation 20000517
77 LOCK_INSTANCE Static method Public Method Set Lock of Formula Instance (Formula Maintenance) 20000623
78 LOCK_TRIGGER Static method Public Method Set lock of Trigger Compression 20000516
79 OPEN Instance method Public Method Open Formula Instance (For Maintenance) 20000502
80 OPEN_CALCULATION_CONTROL Instance method Public Method Open Calculation Run for Control Data: New Number 20000621
81 PREPARE_CLOSE Instance method Public Method Check Whether Object Data Were Changed 20000713
82 READ_COMPRESSED_TRIGGER_ALL Instance method Public Method Read Entire Compressed Trigger File (For Calculation) 20000517
83 READ_COMPRESSED_TRIGGER_UNUSED Instance method Public Method Read Compressed Triggers not to be Processed 20000516
84 READ_HEADER Static method Public Method Read Header Data from Formula Instance from DB 20000510
85 READ_INPUT_PARAMETER Static method Public Method Read Input Parameters of Formula Instance from DB 20000510
86 READ_INSTANCE Static method Public Method Read Formula Instance from DB 20000504
87 READ_OUTPUT_PARAMETER Static method Public Method Read Output Parameters of Formula Instance from DB 20000510
88 READ_STATUSGROUP Instance method Public Method Read Status Group of Formula Instance 20000530
89 READ_TEMPORARY_TRIGGER_FOR_ALL Instance method Public Method Read all Temporary Trigger Records 20000516
90 READ_TRIGGER_FOR_INSTANCE Static method Public Method Read Trigger File of Formula Instance 20000510
91 RESET_INTERVALS_IN_USE Instance method Public Method Reset Processing Indicator in Interval Table 20000627
92 SET_INSTANCE_ACTIVE Static method Public Method Delete Trigger After Successful Synchronous Calculation 20001227
93 SET_INSTANCE_CHECK_FLAG Instance method Public Method Set Indicator That Formula Instance Has Been Checked 20000725
94 SUBTRACT_OFFSETDATE_FROM_DATE Instance method Public Method Subtract Offset Date from Date and Time 20000712
95 SUBTRACT_SECOND Static method Public Method Subtract Second from Event 20000728
96 UNLOCK_CALCULATION Static method Public Method Delete Lock of Formula Instance Calculation 20000517
97 UNLOCK_INSTANCE Instance method Public Method Delete Lock of Formula Instance (For Maintenance) 20000623
98 UNLOCK_TRIGGER Static method Public Method Delete Lock of Trigger Compression 20000516
99 UPDATE Instance method Public Method Update Formula Instance on DB (For Maintenance) 20000502
100 UPDATE_CALCULATION_RUN Static method Public Method Change Control Data of Calculation Run 20000619
101 UPDATE_PREPARE Instance method Public Method Preparation from Update (For Maintenance) 20000718
Events
Class CL_ISU_EDM_FORMULA_INSTANCE has no event.
Types
Class CL_ISU_EDM_FORMULA_INSTANCE has no local type.
Method Signatures

Method ADD_OFFSETDATE_TO_DATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing DATE Call by reference Type reference (TYPE) EEDMDATEFROM Datum auf das addiert werden soll 20000711
2 Exporting NEW_DATE Call by reference Type reference (TYPE) EEDMDATEFROM Addiertes Datum 20000711
3 Importing OFFSET_DATE Call by reference Type reference (TYPE) EEDM_INTERVAL Offset-Datum 20000711

Method ADD_OFFSETDATE_TO_DATE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method ADD_SECOND Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing DATETIME Call by reference Type reference (TYPE) EEDMDATEFROM Datum und Zeit 20000728

Method ADD_SECOND on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method ASYNCHRON_CALC_EXECUTE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000613
2 Exporting FL_FINISHED Call by reference Type reference (TYPE) E_FL_FINISHED Kennzeichen: Letzter Intervall fertig 20000522
3 Importing HIERARCHY_LEVEL Call by reference Type reference (TYPE) E_HIERARCHY_LEVEL Hierarchiestufe der Formelinstanz 20000519
4 Importing TIMESLOTNR Call by reference Type reference (TYPE) E_TIMESLOTNR Lfd. Nummer der Zeitscheibe in der Formelinstanzhierarchie 20000525
# Exception Resumable Description Created on
1 ERROR_IN_CALCULATION Fehler in der Berechnung 20000605
2 ERROR_LOCK_INTERVAL Fehler beim Sperren des Intervalls 20000519
3 ERROR_UPDATE_INTERVAL Fehler beim Update des Intervalls (Bearbeitungskennzeichen) 20000519
4 INTERNAL_ERROR Interner Fehler in der Intervallbearbeitung 20000519

Method ASYNCHRON_CALC_INTERVALS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CALC_CONTROL Call by reference Type reference (TYPE) EFORMULAINSTCALC ISU EDM Kontrolldaten zur Berechnungslaufnummer (DB-Tab.) 20000619
# Exception Resumable Description Created on
1 EITHER_INTSIZE_OR_INTNUMBERS entweder Intervallgröße oder Anzahl Intervalle eingeben 20000523
2 ERROR_INSERT_INTERVALS Fehler beim Anlegen der Intervalle auf DB 20000523
3 NO_CALCULATION_RUN_SPECIFIED Keine Berechnungslaufnummer angegeben 20000613
4 NO_DATA_FOR_LEVEL Keine Sätze für diese Hierarchiestufe vorhanden 20000613
5 NO_LEVEL_SPECIFIED Keine Hierarchiestufe angegeben 20000523
6 NO_TIMESLOT_SPECIFIED Keine Zeitscheibennummer angegeben 20000525

Method ASYNCHRON_CALC_PREPARE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CALC_CONTROL Call by reference Type reference (TYPE) EFORMULAINSTCALC ISU EDM Kontrolldaten zur Berechnungslaufnummer (DB-Tab.) 20000619
2 Exporting MAX_LEVELS Call by reference Type reference (TYPE) E_MAX_LEVELS Anzahl ermittelte Hierarchiestufen 20000519
3 Exporting MAX_TIMESLOTS Call by reference Type reference (TYPE) E_MAX_TIMESLOTS Anzahl ermittelter Zeitscheiben in der Hierarchie 20000525
# Exception Resumable Description Created on
1 CALCULATION_ALREADY_LOCKED Die Berechnung ist bereits aktiv 20000519
2 ERROR_CREATE_HIERARCHY Fehler beim Erstellen der Triggertabelle 20000616
3 ERROR_GET_NEXT_CALC_NR Fehler beim Holen nächste Berechnungslaufnummer 20000613
4 ERROR_INSERT_CALCULATION_RUN Fehler beim Anlegen der Kontrolldaten eines Berechnungslaufs 20000619
5 ERROR_RESET_INTERVALS Fehler beim Reset Bearbeitungskennz. in Intervalltabelle 20000619
6 ERROR_UPDATE_CALCULATION_RUN Fehler beim Ändern der Kontrolldaten eines Berechnungslaufs 20000619
7 NEW_CALCULATION_NOT_ALLOWED Neuer Berechnungslauf ist nicht erlaubt 20000619
8 RESTART_NOT_ALLOWED Restart ist nicht erlaubt 20000619
9 TRIGGER_ALREADY_LOCKED Triggerkomprimierung ist aktiv od. Berechnungssel. ist aktiv 20000519

Method BUILD_JOBNAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing HIERARCHY_LEVEL Call by reference Type reference (TYPE) E_HIERARCHY_LEVEL Hierarchiestufe der Formelinstanz 20000525
2 Exporting JOBNAME Call by reference Type reference (TYPE) TBTCO-JOBNAME Voller Name des Jobs 20000525
3 Importing JOBNAME_TEMPLATE Call by reference Type reference (TYPE) TBTCO-JOBNAME Präfix des Jobnames 20000525
4 Importing TIMESLOTNR Call by reference Type reference (TYPE) E_TIMESLOTNR Lfd. Nummer der Zeitscheibe in der Formelinstanzhierarchie 20000525

Method BUILD_JOBNAME on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method BUILD_TIMESLOTS_IN_INTERVALS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing TIMESLOTS Call by reference Type reference (TYPE) TETIMESLOT ISU EDM Zeitscheibe (int. Tabelle) 20000524
# Exception Resumable Description Created on
1 ERROR_OCCURRED Allgemeiner Fehler 20060724

Method BUILD_TIMESLOTS_IN_PARAMETER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing INPUTPARM Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Zeitscheibe (int. Tabelle) 20000627
2 Exporting INPUTPARM_NEW Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Zeitscheiben neu 20000627

Method BUILD_TIMESLOTS_IN_PARAMETER on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method CALCULATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ERROR_TYPE Call by reference Type reference (TYPE) E_ERROR_TYPE Fehlertyp der Berechnung einer Formelzordnung 20010102
2 Importing FL_SYNCHRON Call by reference Type reference (TYPE) E_FL_SYNCHRON SPACE Kennzeichen: Synchrone Formelinstanzberechnung 20000523
3 Importing FL_UPDATE Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Update der Ergebnisse auf Profile 20000530
4 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000523
5 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000523
6 Exporting RESULT Call by reference Type reference (TYPE) TEFORMULARESULTS EDM Ergebnis aus synchroner Formelinstanzberechnung (Tab.) 20000529
7 Importing SYNC_CALC_TS Call by reference Type reference (TYPE) TEEDM_DATE_TIME_FROM_TO Zeitscheiben f. synchrone Berechnung 20010202
8 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000523
# Exception Resumable Description Created on
1 ERROR_IN_CALCULATION Fehler in der Berechnung der Formelinstanz 20000530
2 ERROR_OPEN_LOG Fehler beim Öffnen der Meldungen für sychrone Berechnung 20010131
3 NO_DATES_SPECIFIED keine Zeitscheiben oder kein Von und Bis Datum angegeben 20010202
4 NO_DATE_FROM_SPECIFIED Kein Von Datum angegeben 20000523
5 NO_DATE_TO_SPECIFIED Kein Bis Datum angegeben 20000523
6 NO_INSTANCE_NUMBER_SPECIFIED Keine Formelinstanznummer angegeben 20000523
7 SYNCHRON_CALCULATION_NOT_SUPP Synchrone Berechnung ist noch nicht unterstützt 20000629
8 WARNING_IN_CALCULATION Warnung in der Berechnung der Formelinstanz 20000720

Method CALCULATE_OFFSET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting DATE_TIME Call by reference Type reference (TYPE) EEDM_INTERVAL Struktur für Ab-Datum 20000710
2 Importing INTSIZEID Call by reference Type reference (TYPE) INTSIZEID Identifikation der Intervallgröße 20000710
3 Importing PREVINTERVALS Call by reference Type reference (TYPE) E_PREVINTERVALS Anzahl der beeinflußenden Intervalle 20000710
# Exception Resumable Description Created on
1 ERROR_IN_INTERVALSIZE Fehler in der Intervall-ID 20000710

Method CALC_MSG_DISPLAY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing MSG_HANDLE Call by reference Type reference (TYPE) EMSG_GEN-HANDLE Idendifikation eines MESSAGE-Objektes 20010131

Method CALC_MSG_DISPLAY on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method CALC_MSG_OPEN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting MSG_HANDLE Call by reference Type reference (TYPE) EMSG_GEN-HANDLE Idendifikation eines MESSAGE-Objektes 20010131
# Exception Resumable Description Created on
1 ERROR_OPEN_LOG Fehler beim Öffnen des Application-Logs 20010131

Method CALC_TIMESLOT_OF_INTERVAL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting CALC_FROM Call by reference Type reference (TYPE) EEDMDATEFROM berechnetes Intervallende 20000510
2 Exporting CALC_TO Call by reference Type reference (TYPE) EEDMDATETO berechneter Intervallbeginn 20000510
3 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Von Ausschnittszeitpunkt 20000510
4 Importing INTERVAL_FROM Call by reference Type reference (TYPE) EEDMDATEFROM abzugrenzender Intervallbeginn 20000510
5 Importing INTERVAL_TO Call by reference Type reference (TYPE) EEDMDATETO abzugrenzendes Intervallende 20000510
6 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Bis Ausschnittszeitpunkt 20000510
# Exception Resumable Description Created on
1 NOT_IN_RANGE Ausschnittstdaten nicht in Intervall 20000510

Method CHECK_COMPLETENESS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ERROR_PARM Call by reference Type reference (TYPE) EFORMULAINSTPARAM_I ISU EDM Eingabeparameterzuordnung zur Formelinstanz 20000721
2 Importing FORMULA Call by reference Type reference (TYPE) EEDMFORMULA Datentyp für Formel 20000721
3 Importing INPUT_PARAMETER Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Zeitscheibe (int. Tabelle) 20000721
4 Changing MASS Call by reference Type reference (TYPE) TEDM_MASS EDM verwendete Maßeinheiten Formleinstanz 20000724
5 Importing OUTPUT_PARAMETER Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_O ISU EDM Ausgabeparameter zur Formelinstanz (int. Tabelle) 20000721
6 Changing VALCAT Call by reference Type reference (TYPE) TEDM_VALCAT EDM Formelinstanz Wertetypen 20000724
# Exception Resumable Description Created on
1 NO_PARM_ASSIGNMENT_INPUT Parameterzuordnung Input fehlt 20000721
2 NO_PARM_ASSIGNMENT_OUTPUT Parameterzuordnung Output fehlt 20000721

Method CHECK_CONTINUOUSLY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing DATEFROM Call by reference Type reference (TYPE) EEDMDATEFROM Ab-Datum 20000725
2 Importing DATETO Call by reference Type reference (TYPE) EEDMDATETO Bis-Datum 20000725
3 Exporting ERROR_PARM Call by reference Type reference (TYPE) EFORMULAINSTPARAM_I ISU EDM Eingabeparameterzuordnung zur Formelinstanz 20000627
4 Importing FORMULA Call by reference Type reference (TYPE) EEDMFORMULA Datentyp für Formel 20000627
5 Importing INPUT_PARAMETER Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Zeitscheibe (int. Tabelle) 20000627
# Exception Resumable Description Created on
1 NOT_CONTINUOUSLY Nicht lückenlos 20000627
2 OVERLAPPING Überlappungen 20040223
3 START_AND_END_DATE Intervall liegt innerhalb Start - und Endedatum 20000725

Method CHECK_IF_INSTANCE_IS_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ACTIVE Call by reference Type reference (TYPE) BOOLE Formelinstanz ist aktiv (kein Trigger vorhanden) 20000517
2 Exporting ACTIVE_STATUS Call by reference Type reference (TYPE) E_STAT_INST Status der Berechnung einer Formelzuordnung 20010117
3 Importing FL_COMPRESS_TRIGGER Call by reference Type reference (TYPE) BOOLE-BOOLE Boolesche Variable 20010201
4 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000517
5 Exporting HIERARCHY_TABLE Call by reference Type reference (TYPE) TEFORMULAHIER ISU EDM Hierarchiestufen der Formelinstanz (int. Tabelle) 20001227
6 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000517
7 Exporting STATUS_INFO Call by reference Type reference (TYPE) TEFORMULAINSTSTATINFO Statusinformationen einer Formelinstanz (int.Tabelle) 20001215
8 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000517
9 Exporting TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGGER_KMP ISU EDM komprimierte Triggerdatei zu Formelinstanz int. Tab 20001227
10 Exporting TRIGGER_TMP Call by reference Type reference (TYPE) TEFORMULATRIGGER_TMP ISU EDM temporäre Triggerdatei zu Formelinstanz int. Tab. 20001227
# Exception Resumable Description Created on
1 ERROR_COMPRESS_TRIGGER Fehler beim komprimieren der Trigger 20010201
2 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer wurde nicht angegeben 20000517

Method CHECK_IF_JOB_IS_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ACTIVE Call by reference Type reference (TYPE) BOOLE-BOOLE Ein Job ist aktiv 20000707

Method CHECK_IF_JOB_IS_ACTIVE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method CLOSE Signature

Method CLOSE on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
# Exception Resumable Description Created on
1 NOT_OPENED Objekt wurde nicht geöffnet 20000502

Method COMPRESS_ACTION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing ACTION Call by reference Type reference (TYPE) TEPROFVALSTAT_ACTIONS Tabellentyp zu Vorgängen auf Profilwerte 20000530
# Exception Resumable Description Created on
1 ERROR_COMPRESS_ACTION Fehler beim Komprimieren der Statusintervalle 20000530

Method COMPRESS_STATUS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing STATUS Call by reference Type reference (TYPE) TEPROFSTATUS Tabelle mit Statusdaten zu Profilwerten 20000530
# Exception Resumable Description Created on
1 ERROR_COMPRESS_STATUS Fehler beim Komprimieren der Statusintervalle 20000530

Method COMPRESS_TRIGGER Signature

Method COMPRESS_TRIGGER on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
# Exception Resumable Description Created on
1 ERROR_COMPRESS_TRIGGER Fehler bei der Triggerkomprimierung 20000516
2 ERROR_DELETE_OLD_KMP_TRIGGER Fehler beim Löschen der alten komprimierten Triggersätze 20000516
3 ERROR_DELETE_OLD_TMP_TRIGGER Fehler beim Löschen der temporären Triggersätze 20000517
4 ERROR_INSERT_COMPR_TRIGGER Fehler beim Insert der neuen komprimierten Triggersätze 20000516
5 ERROR_UPDATE_PREP_KMP_TRIGGER Fehler beim Vorbereiten Insert der neuen kompr. Triggersätze 20000516
6 TRIGGER_ALREADY_LOCKED Triggerkomprimierung oder Instanzberechnung bereits aktiv 20000516

Method CONVERT_LTC_TIME_TO_UTC Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing DATE Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000911
2 Exporting DATE_UTC Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000911

Method CONVERT_LTC_TIME_TO_UTC on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method CONVERT_UTC_TIME_TO_LTC Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting DATE Call by reference Type reference (TYPE) EEDMDATEFROM Datum in LTC 20000911
2 Importing DATE_UTC Call by reference Type reference (TYPE) EEDMDATEFROM Datum in UTC 20000911

Method CONVERT_UTC_TIME_TO_LTC on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method COPY_PROFILE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing X_OUTPUT_PROFILE_OBJ Call by reference Object reference (TYPE REF TO) CL_ISU_EDM_PROFILE EDM Profil 20031112
2 Importing X_PROFILENR_COPY Call by reference Type reference (TYPE) E_PROFILE Nummer des EDM-Profils 20031112
# Exception Resumable Description Created on
1 ERROR_DURING_COPY_PROFILE Fehler beim Kopieren 20031112
2 GENERAL_FAULT Allgemeiner Fehler 20031112

Method CREATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing HEADER Call by reference Type reference (TYPE) EFORMULAINST_DATA ISU EDM Datenfelder zum Kopf der Formelinstanz 20000623
2 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000623
3 Importing UPD_ONLINE Call by reference Type reference (TYPE) REGEN-UPD_ONLINE 'X' Update über Dialog 20000623
# Exception Resumable Description Created on
1 ALREADY_LOCKED Formelinstanz bereits gesperrt 20000623
2 ALREADY_OPENED Objekt ist bereits geöffnet 20000623
3 NUMBER_ERROR Fehler bei der Nummernvergabe 20000623

Method CREATE_INTERVALS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000613
2 Importing HIERARCHY_LEVEL Call by reference Type reference (TYPE) E_HIERARCHY_LEVEL Hierarchiestufe der Formelinstanz 20000519
3 Exporting INTERVALS Call by reference Type reference (TYPE) TEFORMULAINTERVAL ISU EDM Intervalle einer Hierarchiestufe (int.Tabelle) 20000519
4 Importing INTNMBR Call by reference Type reference (TYPE) E_INTNMBR Anzahl Intervalle 20000519
5 Importing INTSIZE Call by reference Type reference (TYPE) E_INTSIZE Anzahl Datensätze in einem Intervall 20000519
6 Importing TIMESLOTNR Call by reference Type reference (TYPE) E_TIMESLOTNR Lfd. Nummer der Zeitscheibe in der Formelinstanzhierarchie 20000525
# Exception Resumable Description Created on
1 NO_DATA_FOR_LEVEL Keine Daten für Hierarchiestufe zu bearbeiten 20000519

Method CREATE_TRIGGER_FOR_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CHECK_INPUT_INTSIZE Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20081111
2 Importing FL_CALC_OFFSET Call by reference Type reference (TYPE) BOOLE-BOOLE 'X' Berechnung des Offset des Formelparameters 20000711
3 Importing FL_FROM_CALC Call by reference Type reference (TYPE) E_FL_FROM_CALC SPACE Kennzeichen: Eintrag stammt aus Formelinstanzberechnung 20000620
4 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000613
5 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000613
6 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000613
# Exception Resumable Description Created on
1 ERROR_CALCULATING_OFFSET Fehler bei der Berechnung des Offset 20000712
2 ERROR_CREATING_TRIGGER Fehler beim Schreiben der Triggerdatei 20000613
3 ERROR_OPEN_PROFILE Fehler beim Öffnen des Profils 20010214
4 ERROR_READING_HIERARCHY Fehler bei der Hierarchieermittlung 20000613
5 NO_INSTANCE_SPECIFIED Profilnummer wurde nicht angegeben 20000613
6 WRONG_INTERVAL Fehler in Zeitintervall 20010214

Method CREATE_TRIGGER_FOR_PROFILE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_CALC_OFFSET Call by reference Type reference (TYPE) BOOLE-BOOLE 'X' Berechnung des Offset des Formelparameters 20000711
2 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000515
3 Importing IM_DAY_PROF_TIME_MODE Call by reference Type reference (TYPE) CHAR1 '3' Tagesw.Prof. - Zeitmodus (Lokal, UTC, UTC Ö.ZP. konstant) 20090515
4 Importing PROFILENR Call by reference Type reference (TYPE) E_PROFILE Nummer des EDM-Profils 20000515
5 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000515
# Exception Resumable Description Created on
1 ERROR_CREATING_TRIGGER Fehler beim Schreiben der Triggerdatei 20000515
2 ERROR_OPEN_PROFILE Fehler beim Öffnen des Profils 20010214
3 ERROR_READING_HIERARCHY Fehler bei der Hierarchieermittlung 20000515
4 NO_PROFILE_SPECIFIED Profilnummer wurde nicht angegeben 20000515
5 WRONG_INTERVAL Fehler in Zeitintervall 20010214

Method DELETE_INTERVALS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000628

Method DELETE_INTERVALS on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method DELETE_INTERV_FROM_INTERV Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing DEL_FROM Call by reference Type reference (TYPE) EEDMDATEFROM Zu löschender Intervall Von 20001219
2 Importing DEL_TO Call by reference Type reference (TYPE) EEDMDATETO Zu löschender Intervall Bis 20001219
3 Exporting NEW_INTERV Call by reference Type reference (TYPE) TETIMESLOT neue Intervalle 20001219
4 Importing OLD_INTERV Call by reference Type reference (TYPE) TETIMESLOT existierende Intervalle 20001219
# Exception Resumable Description Created on
1 NO_DATE_FOR_DELETION Keine Daten zum Löschen übergeben 20001219

Method DELETE_TMP_TRIGGER_CALC Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_NEW_TRIGGER Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Zu Löschende Einträge als normale Triggersätze anlegen 20000627

Method DELETE_TMP_TRIGGER_CALC on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method DISPLAY_CALCULATION_ERRORS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing GRID_TITLE Call by reference Type reference (TYPE) LVC_TITLE ALV-Control: Text der Titelzeile 20001011
2 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der Formelzuordnung 20010112
# Exception Resumable Description Created on
1 ERROR_IN_GRID Fehler in GRID Anzeige 20001011
2 NO_ERRORS_FOUND Keine fehlerhaften Berechnungen gefunden 20001011

Method DISPLAY_FORMULAINSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der Formelzuordnung 20010215
# Exception Resumable Description Created on
1 NOT_FOUND Formelzuordnung ist nicht vorhanden 20010215
2 NO_INSTANCE_SPECIFIED Keine Formelzuordnung übergeben 20010215
3 PROFILE_NOT_FOUND Profil kann nicht angezeigt werden 20010215

Method GET_CRITICAL_DATE_TIME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing X_YEAR Call by reference Type reference (TYPE) EEDMDATEFROM Jahr 20060724
2 Exporting Y_CRIT_DLS_FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20060724
3 Exporting Y_CRIT_DLS_TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20060724
4 Exporting Y_CRIT_STA_FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20060724
5 Exporting Y_CRIT_STA_TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20060724
6 Exporting Y_TIMEDIFF_DLS Call by reference Type reference (TYPE) E_EDMTIMEFROM Ab-Zeit 20060724
7 Exporting Y_TIMEDIFF_STA Call by reference Type reference (TYPE) E_EDMTIMEFROM Ab-Zeit 20060724
# Exception Resumable Description Created on
1 ERROR_OCCURRED Allgemeiner Fehler 20060724

Method GET_IMPORTPARAMETER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting INPUT_PARAMETER Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Zeitscheibe (int. Tabelle) 20000725

Method GET_IMPORTPARAMETER on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method GET_INP_PARAM_LOW_FROM_HIGH_TO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting FROM Call by reference Type reference (TYPE) EEDMDATEFROM Kleinstes Von Datum 20000718
2 Importing INPUT_PARAMETER Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Eingabeparameter zur Formelinstanz (int. Tabelle) 20000718
3 Exporting TO Call by reference Type reference (TYPE) EEDMDATETO Größtes Bis Datum 20000718
# Exception Resumable Description Created on
1 NO_INPUT_PARAMETERS Keine Parameter übergeben 20000718

Method GET_INSTANCE_HIERARCHY_DOWN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_CALC_OFFSET Call by reference Type reference (TYPE) BOOLE-BOOLE Den Offset des Formelparameters berechnen 20001204
2 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000530
3 Exporting HIERARCHY Call by reference Type reference (TYPE) TEFORMULAINSTANCE_HIERARCHY ISU EDM Hierarchie der Formelinstanz (int. Tabelle) 20000530
4 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000530
5 Importing INVERT_LEVEL Call by reference Type reference (TYPE) BOOLE-BOOLE 'X' Hierarchiestufe invertieren ( erste = letzte, letzte = erste 20000530
6 Importing PROFILENR Call by reference Type reference (TYPE) E_PROFILE Nummer des EDM-Profils 20000530
7 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000530
# Exception Resumable Description Created on
1 EITHER_INSTANCE_OR_PROFILE Entweder Instanznummer oder Profilnummer eingeben 20000530
2 ERROR_CALCULATING_OFFSET Fehler beim Berechnen des Offsets 20001204
3 ERROR_IN_HIERARCHY Fehler in der Hierarchieermittlung 20000530
4 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer nicht angegeben 20000530

Method GET_INSTANCE_HIERARCHY_UP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_CALC_OFFSET Call by reference Type reference (TYPE) BOOLE-BOOLE Den Offset des Formelparameters berechnen 20000711
2 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000504
3 Exporting HIERARCHY Call by reference Type reference (TYPE) TEFORMULAINSTANCE_HIERARCHY ISU EDM Hierarchie der Formelinstanz (int. Tabelle) 20000515
4 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000504
5 Importing INVERT_LEVEL Call by reference Type reference (TYPE) BOOLE-BOOLE 'X' Hierarchiestufe invertieren ( erste = letzte, letzte = erste 20000525
6 Importing PROFILENR Call by reference Type reference (TYPE) E_PROFILE Nummer des EDM-Profils 20000515
7 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000504
# Exception Resumable Description Created on
1 EITHER_PROFILE_OR_INSTANCE Profilnummer nicht angegeben 20000711
2 ERROR_CALCULATING_OFFSET Fehler beim Errechnen des Datum-Offsets 20000711
3 ERROR_IN_HIERARCHY Fehler in der Hierarchieermittlung 20000515
4 FORMULA_NOT_FOUND Formel ist nicht vorhanden 20000710
5 HEADER_NOT_FOUND Kopfdaten der Formelinstanz nicht gefunden 20000710
6 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer nicht angegeben 20000510

Method GET_INSTANCE_OF_PROFILE_INPUT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_CALC_TIMESLOT Call by reference Type reference (TYPE) E_FL_CALC_TIMESLOT Kennzeichen: Zeitscheibe berechnen 20000515
2 Exporting FORMULAINSTPMI Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Eingabeparameter zur Formelinstanz (int. Tabelle) 20000510
3 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Ab-Datum 20000510
4 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000710
5 Importing PROFILENR Call by reference Type reference (TYPE) E_PROFILE Nummer des EDM-Profils 20000510
6 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Bis-Datum 20000510
# Exception Resumable Description Created on
1 ERROR_IN_TIMESLOT Fehler in der Zeitscheibenberechnung 20000515
2 NO_INSTANCE_FOUND Keine Formelistanz zu Profil vorhanden 20000510
3 NO_PROFILE_SPECIFIED Keine Profilnummer angegeben 20000510

Method GET_INSTANCE_OF_PROFILE_OUTPUT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting FORMULAINSTPMO Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_O ISU EDM Ausgabeparameter zur Formelinstanz (int. Tabelle) 20000510
2 Importing PROFILENR Call by reference Type reference (TYPE) E_PROFILE Nummer des EDM-Profils 20000510
# Exception Resumable Description Created on
1 NO_INSTANCE_FOUND Keine Formelistanz zu Profil vorhanden 20000510
2 NO_PROFILE_SPECIFIED Keine Profilnummer angegeben 20000510

Method GET_LAST_CALCULATION_RUN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting CALC_CONTROL Call by reference Type reference (TYPE) EFORMULAINSTCALC ISU EDM Kontrolldaten zur Berechnungslaufnummer (DB-Tab.) 20000619
# Exception Resumable Description Created on
1 NOT_FOUND Keine Kontrolldaten gefunden 20000619

Method GET_MAX_OFFSET_FOR_HIER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000711
2 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000711
3 Exporting NEW_FROM Call by reference Type reference (TYPE) EEDMDATEFROM Neues Von-Datum incl. Offset 20000711
4 Exporting NEW_TO Call by reference Type reference (TYPE) EEDMDATETO Neues Bis-Datum incl. Offset 20000711
5 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000711
# Exception Resumable Description Created on
1 ERROR_CALCULATING_OFFSET Fehler beim Berechnen des Offset 20000711
2 FORMULA_NOT_FOUND Die Formel aus der Formelinstanz ist nicht vorhanden 20000711
3 HEADER_NOT_FOUND Kopfdaten der formelinstanz nicht gefunden 20000711
4 NO_INPUT_PARAMETERS Formelinstanz hat keine Eingabeparameter 20000711
5 NO_OUTPUT_PARAMETERS Formelinstanz hat keine Ausgabeparameter 20000711
6 PROFILE_NOT_FOUND Profil nicht gefunden 20000711

Method GET_MAX_TIMESLOTS_LEVELS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000628
2 Exporting MAX_LEVELS Call by reference Type reference (TYPE) E_MAX_LEVELS Anzahl ermittelte Hierarchiestufen 20000628
3 Exporting MAX_TIMESLOTS Call by reference Type reference (TYPE) E_MAX_TIMESLOTS Anzahl ermittelter Zeitscheiben in der Hierarchie 20000628

Method GET_MAX_TIMESLOTS_LEVELS on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method GET_NEXT_HIERARCHY_LEVEL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_CALC_OFFSET Call by reference Type reference (TYPE) BOOLE-BOOLE Berechnung des Offset des Formelparameters 20000711
2 Importing FL_TRIGGER Call by reference Type reference (TYPE) E_FL_TRIGGER nicht berechnungsauslösend 20010208
3 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000515
4 Exporting HIERARCHY Call by reference Type reference (TYPE) TEFORMULAINSTANCE_HIERARCHY ISU EDM Hierarchie der Formelinstanz (int. Tabelle) 20000515
5 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000515
6 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000515
# Exception Resumable Description Created on
1 ERROR_CALCULATING_OFFSET Fehler bei der Berechnung des Datumoffsets 20000711
2 ERROR_IN_TIMESLOT Fehler bei der Zeitscheibenermittlung 20000515
3 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer wurde nicht angegeben 20000515

Method GET_NEXT_TIMESLOT_FOR_DISPATCH Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000613
2 Exporting NEXT_HIERARCHY_LEVEL Call by reference Type reference (TYPE) E_HIERARCHY_LEVEL nächste Hierarchiestufe in der Formelinstanzberechnung 20000525
3 Exporting NEXT_TIMESLOTNR Call by reference Type reference (TYPE) E_TIMESLOTNR nächste Zeitscheibe in der Formelinstanzberechnung 20000525
# Exception Resumable Description Created on
1 NO_FOLLOWING_DATA Keine Folgedaten mehr vorhanden 20000525

Method GET_PREV_HIERARCHY_LEVEL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_CALC_OFFSET Call by reference Type reference (TYPE) BOOLE-BOOLE Den Offset derFormelparameter berechnen 20001204
2 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000530
3 Exporting HIERARCHY Call by reference Type reference (TYPE) TEFORMULAINSTANCE_HIERARCHY ISU EDM Hierarchie der Formelinstanz (int. Tabelle) 20000530
4 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000530
5 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000530
# Exception Resumable Description Created on
1 ERROR_CALCULATING_OFFSET Fehler beim Berechnen des Offsets 20001204
2 ERROR_IN_TIMESLOT Fehler bei der Zeitscheibenermittlung 20000530
3 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer wurde nicht angegeben 20000530

Method LCL_ADJUST_INTERVAL_LENGHT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing XY_HIER Call by reference Type reference (TYPE) TEFORMULAINSTANCE_HIERARCHY ISU EDM Hierarchie der Formelinstanz (int. Tabelle) 20100705
2 Importing X_MINUTES Call by reference Type reference (TYPE) I 20100705

Method LCL_ADJUST_INTERVAL_LENGHT on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_BUILD_TIMESLOTS_IN_INTERVL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000524
2 Changing TIMESLOTS Call by reference Type reference (TYPE) TETIMESLOT ISU EDM Zeitscheibe (int. Tabelle) 20000524
3 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000524

Method LCL_BUILD_TIMESLOTS_IN_INTERVL on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_BUILD_TIMESLOTS_IN_PARA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing INTERVAL Call by reference Type reference (TYPE) EFORMULAINSTPARAM_I Struktur für Ab-Datum 20000627
2 Changing TIMESLOTS Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Zeitscheibe (int. Tabelle) 20000627

Method LCL_BUILD_TIMESLOTS_IN_PARA on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_CALCULATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ERROR_TYPE Call by reference Type reference (TYPE) E_ERROR_TYPE Fehlertyp der Berechnung einer Formelzordnung 20010102
2 Importing FL_UPDATE Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Update der Ergebnisse auf Profile 20000530
3 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000523
4 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000712
5 Exporting RESULT Call by reference Type reference (TYPE) TEFORMULARESULT EDM Ergebnis aus einer Formelinstanzberechnung (in. Tab.) 20000529
6 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000523
# Exception Resumable Description Created on
1 ERROR_BUILDING_NEW_STATUS Fehler beim Erstellen des neuen Status 20000714
2 ERROR_CLOSE_PROFILE Fehler beim Schließen des Profils 20000714
3 ERROR_IN_INTERVALSIZE Fehler bei der Berechnung der Intervallgrößen-ID 20000712
4 ERROR_READING_PROFILE Fehler beim Lesen Profil 20000712
5 ERROR_READING_VALUES Fehler beim Lesen der Profilwerte 20000714
6 ERROR_READING_VALUE_MOD Fehler beim Lesen des Bearbeitungsmodus des Wertes 20000802
7 ERROR_UPDATE_RESULT Fehler beim Update der Profilwerte 20000714
8 EXCEPTION_IN_FORMULA Ausnahme in der Formel aufgetreten 20000714
9 FORMULA_NOT_FOUND Formel nicht gefunden 20000712
10 INPUT_PARAMETER_NOT_FOUND Eingabeparameter der Instanz nicht gefunden 20000712
11 INSTANCE_ALREADY_LOCKED Formelzuordnung bereits gesperrt 20010108
12 INSTANCE_NUMBER_NOT_FOUND Keine Formelinstanzdaten übergeben 20000712
13 INTERNAL_PROGRAM_ERROR Interner Programmfehler beim Lesen interne Tabelle 20000714
14 NO_FORMULA_IN_INSTANCE Keine Formel in der Formelinstanz 20000712
15 NO_OUTPUT_PARAMETER Instanz hat keinen Ausgabeparameter 20000721
16 NO_VALUES_FOUND Keine gültigen Werte zu Eingabeparameter gefunden 20000712
17 OUTPUT_PARAMETER_NOT_FOUND Ausgabeparameter der Instanz nicht gefunden 20000712
18 PROFILE_IS_LOCKED Profil ist bereits gesperrt 20010108
19 VALUES_MISSING_FOR_TIMERANGE Es fehlen Werte für den ausgewählten Zeitraum 20000714

Method LCL_CALCULATE_SYNCHRON Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ERROR_TYPE Call by reference Type reference (TYPE) E_ERROR_TYPE Fehlertyp der Berechnung einer Formelzordnung 20010108
2 Importing FL_UPDATE Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Update der Ergebnisse auf Profile 20001115
3 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20001115
4 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20001115
5 Exporting RESULT Call by reference Type reference (TYPE) TEFORMULARESULTS EDM Ergebnis aus synchroner Formelinstanzberechnung (Tab.) 20001115
6 Importing SYNC_CALC_TS Call by reference Type reference (TYPE) TEEDM_DATE_TIME_FROM_TO Tabelle mit DATUM, VON/BIS und Uhrzeit 20010202
7 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20001115
# Exception Resumable Description Created on
1 CALCULATION_ALREADY_LOCKED Die Berechnung ist zur Zeit gesperrt 20001115
2 ERROR_IN_CALCULATION Fehler in der Berechnung der Formelinstanz 20001115
3 ERROR_IN_HIERARCHY Fehler in der Hierarchieermittlung Synchrone Berechnung 20001129
4 ERROR_OPEN_LOG Fehler beim Öffnen der Meldungen 20010131
5 NO_AUTHORITY Keine Berechtigung für synchrone Formelinstanzberechnung 20001115
6 TRIGGER_ALREADY_LOCKED Die Triggerkomprimierung ist zur Zeit gesperrt 20001115
7 WARNING_IN_CALCULATION Warnung in der Berechnung der Formelinstanz 20001115

Method LCL_COMPRESS_TRIGGER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TRIGGER_WA Call by reference Type reference (TYPE) EFORMULATRIGGER_NEW ISU EDM neue komprimierte Triggersätze (interne Verwendung) 20000516
# Exception Resumable Description Created on
1 NO_IMPORT_DATA Keine Eingabedaten angegeben 20000516

Method LCL_CONVERT_AND_UPDATE_RESULT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_UPDATE Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Update der Ergebnisse auf Profile 20000530
2 Importing FORM_PAR_INPUT Call by reference Type reference (TYPE) TEEDMFORMPARLIST_I Tabellentyp für Eingabeparameterliste (EDM Formeln) 20000530
3 Importing FORM_PAR_OUTPUT Call by reference Type reference (TYPE) TEEDMFORMPARLIST_O Tabellentyp für Ausgabeparameterliste (EDM Formeln) 20000530
4 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000530
5 Importing INSTANCE_HEADER Call by reference Type reference (TYPE) EFORMULAINST_HEADER ISU EDM Kopfdaten der Formelinstanz (Struktur) 20000714
6 Importing NEW_STATUS Call by reference Type reference (TYPE) TEEDMFORMSTATUS EDM Status der Ausgabeparameter einer Formelinstanz (int. Ta 20000530
7 Importing PROFILES Call by reference Type reference (TYPE) TEFORMPROFILE EDM Profilobjekte (Referenz) zu einer Formel (int. Tabelle) 20000530
8 Exporting RESULT Call by reference Type reference (TYPE) TEFORMULARESULT EDM Ergebnis aus einer Formelinstanzberechnung (in. Tab.) 20000530
9 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000530
# Exception Resumable Description Created on
1 ERROR_CLOSE_PROFILE Fehler beim Schließen des Profils 20000530
2 ERROR_COMPRESS_ACTION Fehler beim Komprimieren des Vorgangs (Statusintervalle) 20000530
3 ERROR_COPY_PROFILE Fehler bei der Erstellung der Profilkopie 20031110
4 ERROR_PROFILE_VERS_CREATE Fehler beim Erezugen einer Version des Profils 20020426
5 ERROR_READING_PROFILE Fehler beim Lesen des Profils 20000530
6 ERROR_SET_NEW_ACTION Fehler beim Ausführen des Vorgangs auf Profilwerte 20000530
7 ERROR_UPDATE_PREPARE_PROFILE Fehler beim Update-Prepare des Profil 20000530
8 ERROR_UPDATE_PROFILE Fehler beim Update des Profils 20000530
9 FORMULA_NOT_FOUND Formel aus Formelinstanz ist nicht vorhanden 20000530
10 INPUT_PARAMETER_MISSING In Formelinstanz fehlt ein Eingabeparameter 20000530
11 INTERNAL_ERROR Interner Fehler beim Speichern der Formelergebnisse 20000530
12 OUTPUT_PARAMETER_MISSING In Formelinstanz fehlt ein Ausgabeparameter 20000530

Method LCL_CREATE_HIERARCHY_TABLE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000616
2 Importing CALC_TO_DATE Call by reference Type reference (TYPE) E_CALC_TO_DATE Datum bis wohin berechnet wird 20010307
3 Importing FL_RESTART Call by reference Type reference (TYPE) E_FL_RESTART SPACE Wiederaufsetzen einer fehlerhaften Berechnung 20000628
4 Exporting MAX_LEVELS Call by reference Type reference (TYPE) E_MAX_LEVELS Anzahl ermittelte Hierarchiestufen 20000616
5 Exporting MAX_TIMESLOTS Call by reference Type reference (TYPE) E_MAX_TIMESLOTS Anzahl ermittelter Zeitscheiben in der Hierarchie 20000616
# Exception Resumable Description Created on
1 ERROR_BUILDING_HIERARCHY Fehler beim Ermitteln der Hierarchiestufen 20000616
2 ERROR_DELETING_COMPR_TRIGGER Fehler beim Löschen komprimierten Trigger in Bearbeitung 20001212
3 ERROR_INSERT_HIERARCHY Fehler beim Schreiben der Hierarchiestufen auf die DB 20000616
4 ERROR_READING_OUTPUT_PARAM Fehler beim Lesen Ausgabeparameter 20010208
5 ERROR_UPDATE_TRIGGER_IN_USE Fehler beim Setzen Bearbeitungskennzeichen in kompr. Trigger 20000616

Method LCL_CREATE_NEW_STATUS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000531
2 Importing INSTANCE_HEADER Call by reference Type reference (TYPE) EFORMULAINST_HEADER ISU EDM Formelinstanz 20000714
3 Exporting NEW_STATUS Call by reference Type reference (TYPE) TEEDMFORMSTATUS EDM Status der Ausgabeparameter einer Formelinstanz (int. Ta 20000530
4 Importing PROFILES Call by reference Type reference (TYPE) TEFORMPROFILE EDM Profilobjekte (Referenz) zu einer Formel (int. Tabelle) 20000529
5 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000531
# Exception Resumable Description Created on
1 ERROR_CALC_OFFSET Fehler bei der Berechnung der Intervalllänge 20000801
2 STATUSGROUP_NOT_FOUND Die Statusgruppe der Formelinstanz ist nicht vorhanden 20000530
3 STATUS_NOT_IN_GROUP Status eines Profilwertes nicht in der Statusgruppe 20000530

Method LCL_DELETE_INTERV_FROM_INTERV Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing DEL_FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20001219
2 Importing DEL_TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20001219
3 Importing INTV_FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20001219
4 Importing INTV_TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20001219

Method LCL_DELETE_INTERV_FROM_INTERV on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_DELETE_KMP_TRIGGER_IN_USE Signature

Method LCL_DELETE_KMP_TRIGGER_IN_USE on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
Method LCL_DELETE_KMP_TRIGGER_IN_USE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_DELETE_OLD_KMP_TRIGGER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGKMP ISU EDM komprimierte Triggerdatei (int. Tab. für DB-Update) 20000516
# Exception Resumable Description Created on
1 ERROR_DURING_DELETION Fehler beim Löschen der Daten 20000516
2 NO_DATA_FOR_DELETION Keine Daten zum Löschen vorhanden 20000516

Method LCL_DELETE_OLD_TMP_TRIGGER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TRIGGER_TMP Call by reference Type reference (TYPE) TEFORMULATRIGTMP ISU EDM temporäre Triggerdatei (int. Tab. für DB-Update) 20000516
# Exception Resumable Description Created on
1 ERROR_DURING_DELETION Fehler beim Löschen der Daten 20000516
2 NO_DATA_FOR_DELETION Keine Daten zum Löschen vorhanden 20000516

Method LCL_GET_NEXT_INTERVAL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000613
2 Importing HIERARCHY_LEVEL Call by reference Type reference (TYPE) E_HIERARCHY_LEVEL Hierarchiestufe der Formelinstanz 20000613
3 Exporting INTNR Call by reference Type reference (TYPE) E_INTNR Intervallnummer 20000519
4 Importing TIMESLOTNR Call by reference Type reference (TYPE) E_TIMESLOTNR Lfd. Nummer der Zeitscheibe in der Formelinstanzhierarchie 20000613
# Exception Resumable Description Created on
1 ERROR_LOCK_INTERVAL Intervallbearbeitung konnte nicht gesperrt werden 20000519
2 INTERNAL_ERROR Interner Fehler bei der Intervallbearbeitung 20000519
3 NO_FREE_INTERVAL Kein freier Intervall vorhanden 20000519
4 UPDATE_FAILED Fehler bei Update Intervallbearbeitung (Kz in Bearbeitung) 20000519

Method LCL_INIT_ATTRIBUTES Signature

Method LCL_INIT_ATTRIBUTES on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
Method LCL_INIT_ATTRIBUTES on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_INSERT_HIERARCHY_IN_DB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing HIERARCHY Call by reference Type reference (TYPE) TEFORMULAHIER ISU EDM Hierarchiestufen der Formelinstanz (int. Tabelle) 20000519
# Exception Resumable Description Created on
1 ERROR_DURING_INSERT Fehler beim Einfügen der Daten 20000519
2 NO_DATA_FOR_INSERT Keine Daten zum Einfügen übergeben 20000519

Method LCL_INSERT_INTERVALS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing INTERVALS Call by reference Type reference (TYPE) TEFORMULAINTERVAL ISU EDM Intervalle einer Hierarchiestufe (int.Tabelle) 20000519
# Exception Resumable Description Created on
1 ERROR_DURING_INSERT Fehler beim Schreiben der Daten 20000519
2 NO_DATA_FOR_INSERT Keine Daten zum Einfügen angegeben 20000519

Method LCL_INSERT_KMP_TRIGGER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGKMP ISU EDM komprimierte Triggerdatei (int. Tab. für DB-Update) 20000516
# Exception Resumable Description Created on
1 ERROR_DURING_INSERT Fehler beim Insert der komprimierten Triggerdatei 20000516
2 NO_DATA_FOR_INSERT Keine Daten zum Einfügen angegeben 20000516

Method LCL_INSERT_KMP_TRIGGER_PREPARE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting TRIGGER_DB Call by reference Type reference (TYPE) TEFORMULATRIGKMP ISU EDM komprimierte Triggerdatei (int. Tab. für DB-Update) 20000518
# Exception Resumable Description Created on
1 NO_DATA_FOUND Keine Daten für Update gefunden 20000518

Method LCL_INSERT_NEW_CALCULATION_RUN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALC_CONTROL Call by reference Type reference (TYPE) EFORMULAINSTCALC ISU EDM Kontrolldaten zur Berechnungslaufnummer (DB-Tab.) 20000619
# Exception Resumable Description Created on
1 ERROR_DURING_INSERT Fehler beim Anlegen 20000619
2 NO_DATA_FOR_INSERT Keine Daten zum Anlegen übergeben 20000619

Method LCL_INSERT_TMP_TRIGGER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TRIGGER_TMP Call by reference Type reference (TYPE) TEFORMULATRIGTMP ISU EDM temporäre Triggerdatei (int. Tab. für DB-Update) 20000516
# Exception Resumable Description Created on
1 ERROR_DURING_INSERT Fehler beim Insert der temporären Triggerdatei 20000516
2 NO_DATA_FOR_INSERT Keine Daten zum Einfügen angegeben 20000516

Method LCL_INTERVAL_CALCULATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000613
2 Importing HIERARCHY_LEVEL Call by reference Type reference (TYPE) E_HIERARCHY_LEVEL Hierarchiestufe der Formelinstanz 20000523
3 Importing INTNR Call by reference Type reference (TYPE) E_INTNR Intervallnummer 20000523
4 Exporting STAT_INTV Call by reference Type reference (TYPE) E_STAT_INTV Status der Intervallerstellung im Berechnungslauf 20000615
5 Importing TIMESLOTNR Call by reference Type reference (TYPE) E_TIMESLOTNR Lfd. Nummer der Zeitscheibe in der Formelinstanzhierarchie 20000531
# Exception Resumable Description Created on
1 ERROR_CREATE_TRIGGER_FROM_CALC Fehler bei Erstellung Triggerdatei aus Berechnung 20000613
2 ERROR_IN_CALCULATION Fehler in der Berechnung 20000605
3 ERROR_SET_STATUS_INST Fehler beim Setzen Bearbeitungsstatus der Formelinstanz 20000615
4 INTERVAL_NOT_FOUND Intervall existiert nicht 20000523
5 NO_HIERARCHY_DATA_FOUND Keine Hierarchiedaten zu ausgewähltem Intervall vorhanden 20000523
6 NO_INTERVAL_SPECIFIED Keine Intervallnummer angegeben 20000523

Method LCL_INTERVAL_CONFIRM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000613
2 Exporting FL_FINISHED Call by reference Type reference (TYPE) E_FL_FINISHED Alle Intervalle sind fertig 20000519
3 Importing HIERARCHY_LEVEL Call by reference Type reference (TYPE) E_HIERARCHY_LEVEL Hierarchiestufe der Formelinstanz 20000613
4 Importing INTNR Call by reference Type reference (TYPE) E_INTNR Intervallnummer 20000519
5 Importing STAT_INTV Call by reference Type reference (TYPE) E_STAT_INTV Status der Intervallerstellung im Berechnungslauf 20000615
6 Importing TIMESLOTNR Call by reference Type reference (TYPE) E_TIMESLOTNR Lfd. Nummer der Zeitscheibe in der Formelinstanzhierarchie 20000613
# Exception Resumable Description Created on
1 ERROR_LOCK_INTERVAL Fehler bei Sperren der Intervallbearbeitung 20000519
2 ERROR_UPDATE_INTERVAL Fehler beim Update des Intervalls 20000519

Method LCL_LOCK_INTERVAL Signature

Method LCL_LOCK_INTERVAL on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
# Exception Resumable Description Created on
1 ALREADY_LOCKED Intervallbearbeitung bereits gesperrt 20000519

Method LCL_MERGE_TRIGGER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGKMP ISU EDM komprimierte Triggerdatei (int. Tab. für DB-Update) 20000516
2 Importing TRIGGER_TMP Call by reference Type reference (TYPE) TEFORMULATRIGTMP ISU EDM temporäre Triggerdatei (int. Tab. für DB-Update) 20000516
# Exception Resumable Description Created on
1 COMPRESSION_NOT_NECESSARY Komprimierung nicht erforderlich 20000516
2 ERROR_COMPRESS_TRIGGER Fehler beim Abmischen komprimierter Triggersätze 20000517

Method LCL_RESET_HIERARCHY_TABLE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000627

Method LCL_RESET_HIERARCHY_TABLE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_SET_STATUS_CALC_DETAIL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing HIERARCHY Call by reference Type reference (TYPE) EFORMULAHIER ISU EDM Hierarchiestufen der Formelinstanz (DB-Tabelle) 20000615
2 Importing STAT_INST Call by reference Type reference (TYPE) E_STAT_INST Status der Berechnung einer Formelinstanz 20000615
# Exception Resumable Description Created on
1 ERROR_SET_STATUS Fehler beim Setzen Status in Hierarchietabelle 20000615
2 NO_DATA Keine Daten übergeben 20000615

Method LCL_UNLOCK_INTERVAL Signature

Method LCL_UNLOCK_INTERVAL on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
Method LCL_UNLOCK_INTERVAL on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method LCL_UPDATE_KMP_TRIGGER_IN_USE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGKMP ISU EDM komprimierte Triggerdatei (int. Tab. für DB-Update) 20000518
# Exception Resumable Description Created on
1 ERROR_DURING_UPDATE Fehler beim Update der Daten 20000518
2 NO_DATA_FOR_UPDATE_SPECIFIED Keine Daten für Update angegeben 20000518

Method LOCK_CALCULATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ONLY_CHECK Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Nur Prüfung ob gesperrt 20000703
# Exception Resumable Description Created on
1 ALREADY_LOCKED Berechnung ist bereits gesperrt 20000517

Method LOCK_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000623
# Exception Resumable Description Created on
1 ALREADY_LOCKED Formelinstanz ist bereits gesperrt 20000623

Method LOCK_TRIGGER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ONLY_CHECK Call by reference Type reference (TYPE) BOOLE-BOOLE Sperre nur Prüfen 20000803
# Exception Resumable Description Created on
1 ALREADY_LOCKED Trigger ist bereits gesperrt 20000516

Method OPEN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000503
2 Importing MODE Call by reference Type reference (TYPE) REGEN-WMODE '1' Bearbeitungsmodus (1 = Anzeigen, 2 = Ändern, 3 = Anlegen...) 20000502
3 Exporting NO_INPUT_PARAMETERS Call by reference Type reference (TYPE) BOOLE Keine Eingabeparameter zur Formelinstanz vorhanden 20000510
4 Exporting NO_OUTPUT_PARAMETERS Call by reference Type reference (TYPE) BOOLE Keine Ausgabeparameter zur Formelinstanz vorhanden 20000510
5 Importing UPD_ONLINE Call by reference Type reference (TYPE) REGEN-UPD_ONLINE 'X' Update über Dialog 20000623
# Exception Resumable Description Created on
1 ALREADY_LOCKED Objekt ist bereits gesperrt 20000623
2 ALREADY_OPENED Objekt ist bereits geöffnet 20000502
3 CALCULATION_LOCKED Die Berechnung ist zur Zeit gesperrt 20000703
4 MODE_NOT_ALLOWED Bearbeitungsmodus nicht erlaubt 20000623
5 NOT_FOUND Formelinstanz ist nicht vorhanden 20000503

Method OPEN_CALCULATION_CONTROL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting CALC_CONTROL Call by reference Type reference (TYPE) EFORMULAINSTCALC ISU EDM Kontrolldaten zur Berechnungslaufnummer (DB-Tab.) 20000621
2 Importing FL_RESTART Call by reference Type reference (TYPE) E_FL_RESTART Wiederaufsetzen einer fehlerhaften Berechnung 20000621
# Exception Resumable Description Created on
1 ERROR_GET_NEXT_CALC_NR Fehler beim Holen nächste Berechnungslaufnummer 20000621
2 ERROR_INSERT_CALCULATION_RUN Fehler beim Anlegen der Kontrolldaten eines Berechnungslaufs 20000621
3 ERROR_UPDATE_CALCULATION_RUN Fehler beim Ändern der Kontrolldaten eines Berechnungslaufs 20000621
4 NEW_CALCULATION_NOT_ALLOWED Neuer Berechnungslauf ist nicht erlaubt 20000621
5 RESTART_NOT_ALLOWED Restart ist nicht erlaubt 20000621

Method PREPARE_CLOSE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting CHANGES_MADE Call by reference Type reference (TYPE) BOOLE-BOOLE Daten geändert? 20000717

Method PREPARE_CLOSE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method READ_COMPRESSED_TRIGGER_ALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALC_TO_DATE Call by reference Type reference (TYPE) E_CALC_TO_DATE Datum bis wohin berechnet wird 20010308
2 Importing FL_RESTART Call by reference Type reference (TYPE) E_FL_RESTART SPACE Wiederaufsetzen einer fehlerhaften Berechnung 20000628
3 Importing FL_TRIGGER Call by reference Type reference (TYPE) E_FL_TRIGGER SPACE nicht berechnungsauslösend 20010125
4 Exporting TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGKMP ISU EDM komprimierte Triggerdatei (int. Tab. für DB-Update) 20000517
# Exception Resumable Description Created on
1 NOT_FOUND Keine komprimierten Triggerdaten vorhanden 20000517

Method READ_COMPRESSED_TRIGGER_UNUSED Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGKMP ISU EDM komprimierte Triggerdatei (int. Tab. für DB-Update) 20000516
# Exception Resumable Description Created on
1 NOT_FOUND Keine komprimierten Trigger gefunden 20000516

Method READ_HEADER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting HEADER_DATA Call by reference Type reference (TYPE) EFORMULAINST_HEADER ISU EDM Kopfdaten der Formelinstanz (Struktur) 20000510
2 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000510
# Exception Resumable Description Created on
1 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer wurde nicht angegeben 20000510
2 NOT_FOUND Kopfdaten nicht vorhanden 20000510

Method READ_INPUT_PARAMETER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_CALC_TIMESLOT Call by reference Type reference (TYPE) BOOLE-BOOLE Zeitscheibe berücksichtigen 20000526
2 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000510
3 Exporting INPUT_PARAMETER Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_I ISU EDM Eingabeparameter zur Formelinstanz (int. Tabelle) 20000510
4 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000510
5 Importing PARNUMBER Call by reference Type reference (TYPE) EPARNUMBER Parameternummer 20000712
6 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000510
# Exception Resumable Description Created on
1 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer nicht angegeben 20000510
2 NOT_FOUND Eingabeparameter nicht vorhanden 20000510

Method READ_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CHECK_OUTPUT_PARAMETER Call by reference Type reference (TYPE) KENNZX Löschen der Profilnummer 0 20010608
2 Importing FL_CALC_TIMESLOT Call by reference Type reference (TYPE) BOOLE-BOOLE Zeitscheibe berechnen 20000526
3 Exporting FORMULAINSTANCE Call by reference Type reference (TYPE) EFORMULAINSTANCE ISU EDM Formelinstanz 20000504
4 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000504
5 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000504
6 Exporting NO_INPUT_PARAMETER Call by reference Type reference (TYPE) BOOLE Keine Eingabeparameter vorhanden 20000510
7 Exporting NO_OUTPUT_PARAMETER Call by reference Type reference (TYPE) BOOLE Keine Ausgabeparameter vorhanden 20000510
8 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000504
# Exception Resumable Description Created on
1 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer wurde nicht eingegeben 20000504
2 NOT_FOUND Formelinstanz wurde nicht gefunden 20000504

Method READ_OUTPUT_PARAMETER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CHECK_OUTPUT_PARAMETER Call by reference Type reference (TYPE) KENNZX Löschen der Profilnummer 0 20010608
2 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000510
3 Exporting OUTPUT_PARAMETER Call by reference Type reference (TYPE) TEFORMULAINSTPARAM_O ISU EDM Ausgabeparameter zur Formelinstanz (int. Tabelle) 20000510
4 Importing PARNUMBER Call by reference Type reference (TYPE) EPARNUMBER Parameternummer 20000712
# Exception Resumable Description Created on
1 INSTANCE_NUMBER_NOT_SPECIFIED Formelinstanznummer wurde nicht angegeben 20000510
2 NOT_FOUND Ausgabeparameter nicht vorhanden 20000510

Method READ_STATUSGROUP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_INCL_TEXT Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Auch Gruppentext lesen? 20000530
2 Exporting STATUS Call by reference Type reference (TYPE) TEFORMULASTATUS EDM Status zur Statusgruppe (int. Tabelle) 20000530
3 Importing STATUSGROUP Call by reference Type reference (TYPE) E_FORMULASTATUSGROUP Statusgruppe der Formelinstanz 20000530
4 Exporting STATUSTEXT Call by reference Type reference (TYPE) EFORMULASTATGRPT Beschreibung zur Statusgruppe der Formelinstanz 20000530
# Exception Resumable Description Created on
1 NOT_FOUND Statusgruppe nicht vorhanden 20000530

Method READ_TEMPORARY_TRIGGER_FOR_ALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting TRIGGER_TMP Call by reference Type reference (TYPE) TEFORMULATRIGTMP ISU EDM temporäre Triggerdatei (int. Tab. für DB-Update) 20000516
# Exception Resumable Description Created on
1 NOT_FOUND Keine temporären Triggersätze vorhanden 20000516

Method READ_TRIGGER_FOR_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_FROM_CALC Call by reference Type reference (TYPE) E_FL_FROM_CALC Kennzeichen: Eintrag stammt aus Formelinstanzberechnung 20000614
2 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20000510
3 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000510
4 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20000510
5 Exporting TRIGGER_KMP Call by reference Type reference (TYPE) TEFORMULATRIGGER_KMP ISU EDM komprimierte Triggerdatei zu Formelinstanz int. Tab 20000510
6 Exporting TRIGGER_TMP Call by reference Type reference (TYPE) TEFORMULATRIGGER_TMP ISU EDM temporäre Triggerdatei zu Formelinstanz int. Tab. 20000510
# Exception Resumable Description Created on
1 INSTANCE_NUMBER_NOT_SPECIFIED Keine Instanznummer angegeben 20000510
2 NO_TRIGGER_FOUND Keine Triggereinträge gefunden 20000510

Method RESET_INTERVALS_IN_USE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALCNR Call by reference Type reference (TYPE) E_CALCNR Berechnungslaufnummer 20000627
# Exception Resumable Description Created on
1 ERROR_RESET_INTERVALS Fehler beim Reset der Bearbeitungskennz. in Intervalltabelle 20000627

Method SET_INSTANCE_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FL_SET_HIE Call by reference Type reference (TYPE) BOOLE-BOOLE 'X' Hierarchietab. aktiv setzen 20010124
2 Importing FL_SET_KMP Call by reference Type reference (TYPE) BOOLE-BOOLE 'X' kompr. Trigger aktiv setzen 20010124
3 Importing FL_SET_TMP Call by reference Type reference (TYPE) BOOLE-BOOLE 'X' temp. Trigger aktiv setzen 20010124
4 Importing FROM Call by reference Type reference (TYPE) EEDMDATEFROM Struktur für Ab-Datum 20001227
5 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der Formelzuordnung 20001227
6 Exporting IS_ACTIVE Call by reference Type reference (TYPE) BOOLE-BOOLE Instanz ist bereits aktiv 20001227
7 Importing TO Call by reference Type reference (TYPE) EEDMDATETO Struktur für Bis-Datum 20001227

Method SET_INSTANCE_ACTIVE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method SET_INSTANCE_CHECK_FLAG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_CHECKED Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Formelinstanz wurde geprüft 20000725

Method SET_INSTANCE_CHECK_FLAG on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method SUBTRACT_OFFSETDATE_FROM_DATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing DATE Call by reference Type reference (TYPE) EEDMDATEFROM Datum auf das addiert werden soll 20000712
2 Exporting NEW_DATE Call by reference Type reference (TYPE) EEDMDATEFROM Addiertes Datum 20000712
3 Importing OFFSET_DATE Call by reference Type reference (TYPE) EEDM_INTERVAL Offset-Datum 20000712
4 Importing TIMEZONE Call by reference Type reference (TYPE) TIMEZONE SY-ZONLO Zeitzone 20090415

Method SUBTRACT_OFFSETDATE_FROM_DATE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method SUBTRACT_SECOND Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing DATETIME Call by reference Type reference (TYPE) EEDMDATEFROM Datum und Zeit 20000728

Method SUBTRACT_SECOND on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method UNLOCK_CALCULATION Signature

Method UNLOCK_CALCULATION on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
Method UNLOCK_CALCULATION on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method UNLOCK_INSTANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000623

Method UNLOCK_INSTANCE on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method UNLOCK_TRIGGER Signature

Method UNLOCK_TRIGGER on class CL_ISU_EDM_FORMULA_INSTANCE has no parameter.
Method UNLOCK_TRIGGER on class CL_ISU_EDM_FORMULA_INSTANCE has no exception.

Method UPDATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting INSTANCE_NUMBER Call by reference Type reference (TYPE) E_INSTANCE_NUMBER Nummer der EDM Formelinstanz 20000623
# Exception Resumable Description Created on
1 ERROR_CREATING_TRIGGER Fehler beim Schreiben Triggerdatei 20000718
2 ERROR_UPDATE_DATA Fehler beim Ändern der Daten 20000623
3 NOT_ALLOWED Die Methode ist nicht erlaubt 20000623
4 NOT_OPENED Objekt nicht geöffnet 20000504
5 NO_CHANGES Keine Daten geändert 20000623
6 NUMBER_ERROR Fehler bei der Nummernvergabe 20000623
7 UPDATE_ALREADY_DONE Update bereits durchgeführt 20000718
8 UPDATE_PREPARE_MISSING Update Prepare fehlt 20000718

Method UPDATE_CALCULATION_RUN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CALC_CONTROL Call by reference Type reference (TYPE) EFORMULAINSTCALC ISU EDM Kontrolldaten zur Berechnungslaufnummer (DB-Tab.) 20000619
2 Importing CHECK_INPUT_INTSIZE Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20081111
3 Importing FL_NEW_TRIGGER Call by reference Type reference (TYPE) BOOLE-BOOLE SPACE Zu Löschende Einträge als normale Triggersätze anlegen 20000626
# Exception Resumable Description Created on
1 ERROR_CREATE_TRIGGER_FOR_ERROR Fehler beim Schreiben temporärer Trigger für Fehler 20000628
2 ERROR_DELETING_COMPR_TRIGGER Fehler beim Löschen komprimierter Trigger in Arbeit 20001215
3 ERROR_DELETING_TEMP_TRIGGER Fehler beim Löschen temporärer in Arbeit befindliche Trigger 20000619
4 ERROR_UPDATE_HIERARCHY_TABLE Fehler beim Ändern der Hierarchietabelle 20010108
5 ERROR_UPDATING_CALCULATION_RUN Fehler beim Ändern der Kontrolldaten des Berechnungslaufs 20000619
6 NO_DATA_FOR_UPDATE Keine Daten für Update übergeben 20000619

Method UPDATE_PREPARE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting CHANGES_MADE Call by reference Type reference (TYPE) BOOLE-BOOLE Änderungen vorhanden 20000718
# Exception Resumable Description Created on
1 ERROR_IN_TRIGGER_FOR_CHANGES Fehler in den Daten zum Triggerschreiben 20001016
2 INSTANCE_NOT_CHECKED Die Formelinstanz wurde noch nicht geprüft 20000725
3 NOT_ALLOWED Die Methode ist nicht erlaubt 20000718
4 NOT_OPENED Objekt nicht geöffnet 20000718
5 NO_CHANGES Keine Daten geändert 20000718
6 UPDATE_ALREADY_DONE Update wurde bereits durchgeführt 20000718
History
Last changed by/on SAP  20091125 
SAP Release Created in 462