SAP ABAP Class CL_IEQCM_BE_EQUIPMENT (Class for Equipment (Change of History))
Hierarchy
SAP_APPL (Software Component) Logistics and Accounting
   PM-EQM-EQ (Application Component) Equipment
     IEQCM_BE (Package) Change of Equipment History - Backend
Properties
Class CL_IEQCM_BE_EQUIPMENT  
Short Description Class for Equipment (Change of History)    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status P  SAP Standard Production Program 
Category 0   
Package IEQCM_BE   Change of Equipment History - Backend 
Created 20050126   SAP 
Last change 20100310   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 GTYPE Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 IEQCM Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
4 ITOB Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CL_IEQCM_BE_EQUIPMENT has no interface implemented.
Friends
Class CL_IEQCM_BE_EQUIPMENT has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 GC_DATE_NOW Constant Private Type reference (TYPE) DATBI '99991231' Last Date 20050201
2 GS_EQUI Instance attribute Private Type reference (TYPE) EQUI Equipment Master Data 20050127
3 GS_EVENT_TEMP Instance attribute Private Type reference (TYPE) GS_EVENT_TYPE Temporary Event (Template for New Event) 20050322
4 GS_WL_HEADER Instance attribute Private Type reference (TYPE) IEQT_WL_HEADER Header Data of Current Interim Save 20050321
5 GT_CHANGE_PERIODS Instance attribute Private Type reference (TYPE) GT_PERIODS_TYPE Table of Changed Time Intervals 20050224
6 GT_FIELDLIST Static Attribute Private Type reference (TYPE) GT_FIELDLIST_TYPE Field List of Data Fields 20050210
7 GT_HEQUI_LIST Instance attribute Private Type reference (TYPE) GT_HEQUI_LIST_TYPE Table of Superordinate Equipment (Only for Inheritance) 20050406
8 GT_HISTORY_NEW Instance attribute Private Type reference (TYPE) GT_HISTORY_TYPE New History of an Equipment 20050202
9 GT_HISTORY_OLD Instance attribute Private Type reference (TYPE) GT_HISTORY_TYPE Current History of an Equipment 20050202
10 GT_HISTORY_SUP Instance attribute Private Type reference (TYPE) GT_HISTORY_TYPE History of Superordinate Equipment (only for Start Equip.) 20050204
11 GT_HISTORY_SUP_REF Instance attribute Private Object reference (TYPE REF TO) GT_HISTORY_TYPE Reference to History of Superordinate Equip. 20050225
12 GT_INSTANCES Instance attribute Private Type reference (TYPE) GT_OBJECTS_TYPE Table with Equipment Instances 20050202
13 GT_MESSAGES Instance attribute Private Type reference (TYPE) IEQT_MSG Current Messages 20050314
14 GT_OBJECT_LIST_REF Instance attribute Private Object reference (TYPE REF TO) GT_OBJECTS_TYPE Ref. to Table of All Instances of an Inheritance 20050712
15 GT_SUBEQUI_PERIODS Instance attribute Private Type reference (TYPE) GT_PERIODS_TYPE Periods for Which Subequipments are Searched for 20050714
16 G_ASSET_ACTIVE Static Attribute Private Type reference (TYPE) ABAP_BOOL 20050608
17 G_BADI_CHECK Static Attribute Private Object reference (TYPE REF TO) IF_EX_IEQCM_BE_CHECK BAdI Interface IF_EX_IEQCM_BE_CHECK 20050401
18 G_BADI_DECOUPLING Static Attribute Private Object reference (TYPE REF TO) IF_EX_IEQCM_BE_DECOUPLING BADI Interface IF_EX_IEQCM_BE_DECOUPLING 20050315
19 G_DATE_CHANGE Static Attribute Private Type reference (TYPE) AEDAT Date for the Changes 20050222
20 G_DATE_CURRENT Instance attribute Private Type reference (TYPE) DATBI Current Date 20050207
21 G_DATE_LAST Instance attribute Public Type reference (TYPE) DATBI Date of the Last Direct Event 20050217
22 G_DATE_START Instance attribute Private Type reference (TYPE) IEQ_DATAB Start Date of Change 20050217
23 G_DB_UPDATED Instance attribute Private Type reference (TYPE) ABAP_BOOL The changes were posted -> No further changes 20050324
24 G_EQUNR Instance attribute Public Type reference (TYPE) EQUNR Equipment Number of Instance 20050126
25 G_EZBER Static Attribute Private Type reference (TYPE) EQBER Technical information, intended for SAP internal use 20050405
26 G_INDEX_LAST_EVENT Instance attribute Private Type reference (TYPE) SYTABIX Index of Last Event in New History 20050202
27 G_INHERITANCE_OK Instance attribute Private Type reference (TYPE) ABAP_BOOL The changes were inherited successfully 20050331
28 G_INSTALL_CURRENT Instance attribute Public Type reference (TYPE) ABAP_BOOL Is equipment currently installed? 20050317
29 G_LOCKED Instance attribute Public Type reference (TYPE) ABAP_BOOL Lock Status of Equipment 20050126
30 G_START_EQUIPMENT Instance attribute Private Type reference (TYPE) ABAP_BOOL Equipment is Access Equipment 20050126
31 G_TIME_CURRENT Instance attribute Private Type reference (TYPE) TIMBI Current Time 20050207
32 G_TIME_LAST Instance attribute Public Type reference (TYPE) TIMBI Time of Last Direct Event 20050217
33 G_TIME_START Instance attribute Private Type reference (TYPE) IEQ_TIMAB Start Time of Change 20050217
34 G_UNAME Static Attribute Private Type reference (TYPE) SYUNAME User Name for the Changes 20050222
Methods
# Method Level Visibility Method type Description Created on
1 BACKUP_COUNTER_GET_NEXT Static method Private Method Gets Next Backup Counter 20050603
2 CLASS_CONSTRUCTOR Static method Public Constructor CLASS_CONSTRUCTOR 20050209
3 CONSTRUCTOR Instance method Public Constructor CONSTRUCTOR 20050126
4 DB_REALIZE Instance method Public Method Writes the Changes to the Database 20050324
5 DB_TABLES_FILL Instance method Private Method Fills the Tables for the Database Update 20050322
6 DETAIL_CHECK Instance method Public Method Checks Entries on the Detail Screen and Fills Dependent Flds 20050622
7 DETAIL_GET_FOR_COPY Instance method Public Method Copies Changes of an Old Event into Target History 20050215
8 DETAIL_GET_FOR_CREATE Instance method Public Method Detail for Time for Creation of a New Event 20050322
9 DETAIL_GET_FOR_DISPLAY Instance method Public Method Detail for Time 20050322
10 EQUIPMENTTYPE_TEXT_READ Static method Public Method Reads Texts for Equipment Category 20050318
11 EQUIPMENT_ADDRESS_CHANGE Static method Private Method Changes Address of Equipment 20050524
12 EQUIPMENT_AUTHORITY_CHECK Instance method Private Method Authorization Check 20050201
13 EQUIPMENT_CONSISTENCY_CHECK Instance method Public Method Consistency Check for an Equipment 20050126
14 EQUIPMENT_CRM_UPDATE Instance method Private Method Transfers the Change to a CRM System 20050609
15 EQUIPMENT_LOCK Instance method Public Method Lock Equipment 20050126
16 EQUIPMENT_STATUS_CHANGE_DISM Instance method Private Method Set System Status for Dismantled 20050504
17 EQUIPMENT_STATUS_CHANGE_INST Instance method Private Method Set System Status for Installed 20050504
18 EQUIPMENT_STATUS_RESET Static method Public Method Removes Status for History Change 20050324
19 EQUIPMENT_STATUS_SET Static method Public Method Sets Status for History Change 20050323
20 EQUIPMENT_TEXT_READ Static method Public Method Reads the Short Text for an Equipment 20050216
21 EQUIPMENT_UNLOCK Instance method Public Method Locks Equipment 20050201
22 EVENT_ADD Instance method Public Method Attaches New Event (Direct Change) 20050126
23 EVENT_CHANGE Instance method Public Method Changes Event 20050318
24 EVENT_CONSISTENCY_CHECK Instance method Private Method Executes Consistency Check for an Event 20050126
25 EVENT_COPY_MULTIPLE Instance method Public Method Copies a Sequence of Events into the Target History 20050316
26 EVENT_DELETE Instance method Public Method Deletes an Event (and All Subsequent Events) 20050126
27 EVENT_FIND_CHANGES Static method Private Method What changed in the event? 20050128
28 EVENT_HISTORY_RELATED_CHECK Static method Private Method Checks if History-Relevant Fields Were Changed 20050407
29 EVENT_INHERIT_DATA Instance method Private Method Inherit Data for an Event from the Superordinate Object 20050211
30 EVENT_SET_INHERITANCE Instance method Private Method Sets the Inheritance Indicator for an Event 20050215
31 EZBER_FILL Static method Private Method Fills Check-Info (Same Here for All Equipment Usage Periods) 20050405
32 FUNC_LOC_READ Instance method Private Method Reads Superordinate Functional Location 20050401
33 GOODS_MOVEMENT Instance method Private Method Triggers Goods Movement 20050608
34 HISTORY_CHANGE_ALLOWED_CHECK Instance method Private Method Checks Whether History-Relevant Changes are Allowed 20070215
35 HISTORY_CONSISTENCY_CHECK Instance method Public Method Checks the Consistency of Target History 20050404
36 HISTORY_EARLIER_READ Instance method Public Method Read History of Equipment for Earlier Start Date 20050714
37 HISTORY_FROM_BACKUP Instance method Private Method Fill Target History from Backup 20050419
38 HISTORY_FROM_TEMPLATE Instance method Private Method Fill Target History Using Template Equipment 20050315
39 HISTORY_GET Instance method Public Method Returns the Desired History 20050314
40 HISTORY_INHERIT_TO_DATE Instance method Private Method Inherit Target History by Date 20050202
41 HISTORY_READ Static method Private Method Read Actual History for Equipment 20050126
42 HISTORY_SUP_READ Instance method Private Method Reading History of the Superordinate Object 20050401
43 ILOAN_NUMBER_GET_NEXT Static method Public Method Getting Next ILOAN Number 20050329
44 INHERITANCE_EXECUTE Instance method Private Method Performing the Inheritance for an Equipment 20050223
45 INHERITANCE_START Instance method Public Method Starting the Inheritance of the Changed History 20050223
46 INITIALIZE Instance method Public Method Initialize Instance (Delete Target History) 20050126
47 LOCATION_TEXT_READ Static method Public Method Reads Short Text for Functional Location 20050216
48 MEASUREMENTS_UPDATE Instance method Private Method Triggers Measurement Document Changes 20050401
49 MESSAGES_GET Instance method Public Method Gets Messages 20050314
50 MESSAGE_ADD Instance method Private Method Attaches a Message to the Log 20050316
51 STRUCTUR_GAP_HANDLING Instance method Private Method Checks Structure Gaps 20050608
52 SUBEQUIPMENTS_FIND Instance method Private Method Finds Direct Subordinate Equipments 20050222
53 TEST_EVENT_ADD Instance method Public Method Test Method: EVENT_ADD 20050214
54 WORKLIST_GET Instance method Public Method Returns the Work Table (For Example, for Saving) 20050318
55 WORKLIST_HEADER_GET Instance method Public Method Returns the Header of the Work Table 20050318
56 WORKLIST_READ Instance method Public Method Reads the Saved Interim Version for the Equipment 20050321
57 WORKLIST_UPDATE_CHECK Instance method Public Method Checks Whether the Target History Was Changed 20050405
Events
Class CL_IEQCM_BE_EQUIPMENT has no event.
Types
Class CL_IEQCM_BE_EQUIPMENT has no local type.
Method Signatures

Method BACKUP_COUNTER_GET_NEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_COUNTER Call by reference Type reference (TYPE) IEQ_BACKUP Datensicherung 20050603
# Exception Resumable Description Created on
1 COUNTER_LOCKED Der Counter ist gesperrt -> später erneut versuchen 20050603
2 ERROR Fehler 20050603

Method CLASS_CONSTRUCTOR Signature

Method CLASS_CONSTRUCTOR on class CL_IEQCM_BE_EQUIPMENT has no parameter.
Method CLASS_CONSTRUCTOR on class CL_IEQCM_BE_EQUIPMENT has no exception.

Method CONSTRUCTOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_COUNTER Call by reference Type reference (TYPE) IEQ_BACKUP Datensicherung 20050419
2 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050126
3 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20050126
4 Importing I_EQUNR_TEMPLATE Call by reference Type reference (TYPE) EQUNR Equipmentnummer der Vorlage 20050316
5 Importing I_START_EQUIPMENT Call by reference Type reference (TYPE) ABAP_BOOL ABAP_ON Das Equipment ist ein Einstiegsequipment (von außen gerufen) 20050317
6 Importing I_TIME Call by reference Type reference (TYPE) IEQ_TIMAB Uhrzeit gültig ab 20050315
# Exception Resumable Description Created on
1 BACKUP_ERROR Fehler beim Backup 20050419
2 BACKUP_NOT_EXIST Backup nicht gefunden 20050419
3 EQUIPMENT_INACT Das Equipment ist inaktiv 20050330
4 EQUIPMENT_LVORM Das Equipment hat eine Löschvormerkung 20050330
5 EQUIPMENT_NOT_EXISTS_ON_DATE Equipment zum Datum nicht vorhanden 20050127
6 EQUIPMENT_NOT_FOUND Equipment existiert nicht 20050126
7 ERROR Fehler beim lesen der Historie 20050127
8 HISTORY_CHANGE_NOT_ALLOWED historienrelevante Änderung nicht erlaubt 20070228
9 HISTORY_ERROR Fehler beim Lesen der Historie 20050127
10 HISTORY_INACTIVE Das Schreiben von Historiensätzen ist nicht aktiv 20050407
11 LOCK_ERROR Fehler beim Sperren 20050201
12 NO_AUTHORITY keine Berechtigung 20050201
13 SUPERIOR_EQUIPMENT_ERROR Fehler beim Lesen des übergeordneten Equipments 20050330
14 TEMPLATE_ERROR Fehler beim Kopieren der Historie von der Vorlage 20050316
15 TEMPLATE_NOT_EXIST Vorlage nicht gefunden 20050316

Method DB_REALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_SL_MSG Call by reference Type reference (TYPE) IEQCM_T_MSG_SL_TYPE Erfolgsprotokoll 20050404
# Exception Resumable Description Created on
1 COUNTER_LOCKED Der Counter ist gesperrt -> später erneut versuchen 20050603
2 ERROR Fehler 20050324
3 GOODS_MOVEMENT_ERROR Fehler bei Warenbewegungen 20050404
4 MEASUREMENT_ERROR Fehler beim Ändern der Meßwerte 20050401
5 STRUCTUR_GAP_ERROR Fehler bei Structure Gaps 20050404
6 SUBEQUIPMENT_INHERITANCE_ERROR Fehler beim Vererben an ein Unterequipment 20050331
7 SUBEQUIPMENT_INIT_ERROR Fehler beim Instanziieren eines Unterequipments 20050331

Method DB_TABLES_FILL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_EQUI_CHANGE Call by reference Type reference (TYPE) IEQCM_T_EQUI_TYPE Tabelle für EQUI update 20050429
2 Exporting ET_EQUI_OLD Call by reference Type reference (TYPE) IEQCM_T_EQUI_TYPE Tabelle mit originalen EQUI Daten 20050429
3 Exporting ET_EQUI_PERIODS Call by reference Type reference (TYPE) IEQCM_T_EQUI_PERIOD_TYPE Tabelle der Einbauperioden des Equipments 20050420
4 Exporting ET_EQUZ_CHANGE Call by reference Type reference (TYPE) IEQCM_T_EQUZ_TYPE Tabelle für EQUZ Update 20050329
5 Exporting ET_EQUZ_DELETE Call by reference Type reference (TYPE) IEQCM_T_EQUZ_TYPE Tabelle für EQUZ Update 20050329
6 Exporting ET_EQUZ_INSERT Call by reference Type reference (TYPE) IEQCM_T_EQUZ_TYPE Tabelle für EQUZ Update 20050329
7 Exporting ET_ILOA_CHANGE Call by reference Type reference (TYPE) IEQCM_T_ILOA_TYPE Tabelle für ILOA Update 20050329
8 Exporting ET_ILOA_DELETE Call by reference Type reference (TYPE) IEQCM_T_ILOA_TYPE Tabelle für ILOA Update 20050329
9 Exporting ET_ILOA_INSERT Call by reference Type reference (TYPE) IEQCM_T_ILOA_TYPE Tabelle für ILOA Update 20050329
10 Exporting ET_WL_ITEMS_BACK Call by reference Type reference (TYPE) IEQCM_T_WL_ITM_BAC_TYPE Tabelle für Backup der alten und neuen Historie 20050331
11 Importing IT_OBJECT_LIST_REF Call by reference Object reference (TYPE REF TO) GT_OBJECTS_TYPE Ref. auf Tabelle aller Instanzen in der Vererbung 20050715
12 Importing I_BACKUP_COUNTER Call by reference Type reference (TYPE) I_COUNT Zähler für den Backup (Schlüssel) 20050331
# Exception Resumable Description Created on
1 ERROR Fehler 20050322

Method DETAIL_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_DETAIL Call by reference Type reference (TYPE) IEQS_EVENT Arbeitstabelle: Ereignisse 20050622
2 Exporting ET_FIELDS Call by reference Type reference (TYPE) IEQCM_T_FIELD_TYPE geänderte Felder 20050622
3 Exporting E_CHANGED Call by reference Type reference (TYPE) ABAP_BOOL Indikator ob Felder vom system geändert wurden 20050622
4 Importing IS_DETAIL Call by reference Type reference (TYPE) IEQS_EVENT Arbeitstabelle: Ereignisse 20050622
5 Importing IS_ITOBEXT Call by reference Type reference (TYPE) ITOBEXT Technische Objekte PM: Daten mit externer Sicht 20050622
# Exception Resumable Description Created on
1 ERROR Fehler 20050622
2 EVENT_NOT_CONSISTENT Eingabe Fehlerhaft 20050622

Method DETAIL_GET_FOR_COPY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_DETAIL Call by reference Type reference (TYPE) IEQS_EVENT Arbeitstabelle: Ereignisse 20050215
2 Exporting ET_FIELDS Call by reference Type reference (TYPE) IEQCM_T_FIELD_TYPE geänderte Felder 20050215
3 Importing I_DATE_NEW Call by reference Type reference (TYPE) IEQ_DATAB Datum des neuen Ereignisses 20050215
4 Importing I_DATE_OLD Call by reference Type reference (TYPE) IEQ_DATAB Datum des Originalereignisses 20050215
5 Importing I_TIME_NEW Call by reference Type reference (TYPE) IEQ_TIMAB Zeitpunkt des neuen Ereignisses 20050215
6 Importing I_TIME_OLD Call by reference Type reference (TYPE) IEQ_TIMAB Zeitpunkt des Originalereignisses 20050215
# Exception Resumable Description Created on
1 ERROR Fehler 20050215
2 EVENT_NOT_AT_END Event nicht am Ende der Historie 20050217
3 EVENT_NOT_EXISTS Ereignis existiert nicht 20050215
4 EVENT_TYPE_NOT_ALLOWED Der Ereignistyp ist nicht erlaubt 20050323
5 INHERITANCE_ERROR Fehler bei der Vererbung vom übergeordneten Objekt 20050323

Method DETAIL_GET_FOR_CREATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_DETAIL Call by reference Type reference (TYPE) IEQS_EVENT E/A-Struktur: Detailbild 20050322
2 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050322
3 Importing I_EVENT_TYPE Call by reference Type reference (TYPE) IEQ_EVENT_TYPE Ereignistyp 20050322
4 Importing I_HEQUI Call by reference Type reference (TYPE) HEQUI Übergeordnetes Equipment 20050322
5 Importing I_TIME Call by reference Type reference (TYPE) IEQ_TIMAB Uhrzeit gültig ab 20050322
6 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20050322
# Exception Resumable Description Created on
1 ERROR Fehler 20050322
2 EVENT_NOT_AT_END Ereignis nicht am Ende der Historie 20050322
3 EVENT_TYPE_NOT_ALLOWED Der Ereignistyp ist nicht erlaubt 20050322
4 INHERITANCE_ERROR Fehler bei der Vererbung vom übergeordneten Objekt 20050322

Method DETAIL_GET_FOR_DISPLAY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_DETAIL Call by reference Type reference (TYPE) IEQS_EVENT E/A-Struktur: Detailbild 20050322
2 Exporting ET_FIELDS Call by reference Type reference (TYPE) IEQCM_T_FIELD_TYPE geänderte Felder 20050322
3 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050322
4 Importing I_LSTTYP Call by reference Type reference (TYPE) IEQ_LSTTYP alte oder neue Historie 20050322
5 Importing I_TIME Call by reference Type reference (TYPE) IEQ_TIMAB Uhrzeit gültig ab 20050322
# Exception Resumable Description Created on
1 ERROR Fehler 20050322
2 EVENT_NOT_EXISTS Ereignis existiert nicht 20050322

Method EQUIPMENTTYPE_TEXT_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EQTYP Call by reference Type reference (TYPE) EQTYP Equipmenttyp 20050318
2 Importing I_LANGU Call by reference Type reference (TYPE) SYLANGU SY-LANGU Sprachenschlüssel 20050318
3 Returning R_TYPTX Value transfer Type reference (TYPE) TYPTX Bezeichnung Technischer Typ 20050318
# Exception Resumable Description Created on
1 TEXT_NOT_FOUND Keinen text gefunden 20050318

Method EQUIPMENT_ADDRESS_CHANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ADRNRI_OLD Call by reference Type reference (TYPE) INH_ADRNRI Datenherkunft für Feld 'Adresse' 20050601
2 Importing I_ADRNR_NEW Call by reference Type reference (TYPE) AD_ADDRNUM Adreßnummer neu 20050524
3 Importing I_ADRNR_OLD Call by reference Type reference (TYPE) AD_ADDRNUM Adreßnummer alt 20050524
4 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20050524
5 Importing I_UPDATE_MODE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Änderungen werden verbucht 20050621
# Exception Resumable Description Created on
1 ERROR Fehler 20050524

Method EQUIPMENT_AUTHORITY_CHECK Signature

Method EQUIPMENT_AUTHORITY_CHECK on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# Exception Resumable Description Created on
1 ERROR Fehler 20050201
2 NO_AUTHORITY keine Berechtigung 20050201

Method EQUIPMENT_CONSISTENCY_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_CHKCNT Call by reference Type reference (TYPE) IEQCM_S_CHKCNT_TYPE Anzahl der Fehler 20050418
# Exception Resumable Description Created on
1 EQUIPMENT_NOT_CONSISTENT Das Equipment enhält Inconsistenzen 20050126
2 ERROR Fehler 20050404

Method EQUIPMENT_CRM_UPDATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_SL_MSG Call by reference Type reference (TYPE) IEQCM_T_MSG_SL_TYPE Erfolgsprotokoll 20050609
2 Importing IT_EQUI_NEW Call by reference Type reference (TYPE) IEQCM_T_EQUI_TYPE Equipment Stammdaten neu 20050609
3 Importing IT_EQUI_OLD Call by reference Type reference (TYPE) IEQCM_T_EQUI_TYPE Equipment Stammdaten alt 20050609
4 Importing IT_WL_ITEMS_BACK Call by reference Type reference (TYPE) IEQCM_T_WL_ITM_BAC_TYPE Backup - alte und neue Historiendaten 20050609
5 Importing I_DATE_START Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050609
6 Importing I_TIME_START Call by reference Type reference (TYPE) IEQ_TIMAB Uhrzeit gültig ab 20050609
# Exception Resumable Description Created on
1 ERROR Fehler 20050609

Method EQUIPMENT_LOCK Signature

Method EQUIPMENT_LOCK on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# Exception Resumable Description Created on
1 LOCK_ERROR Fehler beim Sperren 20050201

Method EQUIPMENT_STATUS_CHANGE_DISM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_HEQUI Call by reference Type reference (TYPE) HEQUI Übergeordnetes Equipment 20050504
2 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20050504
# Exception Resumable Description Created on
1 ERROR Fehler 20050504

Method EQUIPMENT_STATUS_CHANGE_INST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_HEQUI Call by reference Type reference (TYPE) HEQUI Übergeordnetes Equipment 20050504
2 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20050504
# Exception Resumable Description Created on
1 ERROR Fehler 20050504

Method EQUIPMENT_STATUS_RESET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DB_COMMIT Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE auf Datenbank verbuchen? 20050404
2 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20050324
3 Importing I_OBJNR Call by reference Type reference (TYPE) J_OBJNR Objektnummer 20050404
# Exception Resumable Description Created on
1 ERROR Fehler 20050324
2 STATUS_NOT_SET Status für Equipment nicht gesetzt 20050404

Method EQUIPMENT_STATUS_SET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DB_COMMIT Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Auf Datenbank verbuchen? 20050404
2 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20050323
3 Importing I_OBJNR Call by reference Type reference (TYPE) J_OBJNR Objektnummer 20050404
# Exception Resumable Description Created on
1 ERROR Fehler 20050323

Method EQUIPMENT_TEXT_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20050216
2 Returning R_EQKTX Value transfer Type reference (TYPE) KTX01 Bezeichnung technisches Objekt 20050216
# Exception Resumable Description Created on
1 TEXT_NOT_FOUND Keinen Text gefunden 20050216

Method EQUIPMENT_UNLOCK Signature

Method EQUIPMENT_UNLOCK on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# Exception Resumable Description Created on
1 LOCK_ERROR Fehler beim Sperren 20050201

Method EVENT_ADD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_DETAIL Call by reference Type reference (TYPE) IEQS_EVENT Arbeitstabelle: Ereignisse 20050215
# Exception Resumable Description Created on
1 ERROR Fehler beim anhängen eines Ereignisses 20050126
2 EVENT_NOT_AT_END Ereignis nicht am Ende der Historie 20050214
3 EVENT_NOT_CONSISTENT Neues Ereignis ist nicht Konsistent 20050211
4 INHERITANCE_ERROR Fehler bei der Vererbung 20050210
5 NOTHING_CHANGED Es hat sich nichts geändert, es wird kein Ereignis angehängt 20050303
6 NO_CHANGES_ALLOWED Keine weiteren Änderungen erlaubt 20050324

Method EVENT_CHANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_EVENT Call by reference Type reference (TYPE) IEQS_EVENT Ereignis 20050318
# Exception Resumable Description Created on
1 CHANGE_NOT_ALLOWED Die Änderungen sind nicht erlaubt 20050318
2 ERROR Fehler 20050318
3 EVENT_NOT_CONSISTENT Das Ereignis ist nicht konsistent 20050318
4 EVENT_NOT_EXISTS Das Ereignis existiert nicht 20050321

Method EVENT_CONSISTENCY_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_WARNING Call by reference Type reference (TYPE) ABAP_BOOL Ereignis hat Warnung 20050504
2 Importing IS_EVENT Call by reference Type reference (TYPE) GS_EVENT_TYPE Zu prüfender Event 20050211
# Exception Resumable Description Created on
1 ERROR Fehler 20050211
2 EVENT_NOT_CONSISTENT Der Event enthält Inkonststenzen 20050126

Method EVENT_COPY_MULTIPLE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_EVENT_COUNT Call by reference Type reference (TYPE) SYTABIX Anzahl der kopierten Ereignisse 20050317
2 Importing I_DATE_END Call by reference Type reference (TYPE) DATBI '99991231' Enddatum 20050316
3 Importing I_DATE_START Call by reference Type reference (TYPE) IEQ_DATAB Startdatum 20050316
4 Importing I_TIME_END Call by reference Type reference (TYPE) TIMBI Endzeit 20050316
5 Importing I_TIME_START Call by reference Type reference (TYPE) IEQ_TIMAB Startzeit 20050316
# Exception Resumable Description Created on
1 ERROR Fehler beim anhängen eines Events 20050316
2 EVENT_NOT_AT_END Event nicht am Ende der Historie 20050316
3 EVENT_NOT_CONSISTENT Neues Event ist nicht Konsistent 20050316
4 EVENT_NOT_EXISTS Ereignis existiert nicht 20050316
5 EVENT_TYPE_NOT_ALLOWED Der Ereignistyp ist nicht erlaubt 20050323
6 INHERITANCE_ERROR Fehler bei der Vererbung 20050316

Method EVENT_DELETE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum des Events 20050214
2 Importing I_LAST_EVENT Call by reference Type reference (TYPE) ABAP_BOOL ABAP_ON nur das letzte 'manuelle' Ereignis 20050214
3 Importing I_TIME Call by reference Type reference (TYPE) IEQ_TIMAB Zeit des Events 20050214
# Exception Resumable Description Created on
1 ERROR Fehler beim Löschen des Events 20050126
2 EVENT_NOT_EXISTS Der Event existiert nicht 20050214
3 EVENT_NOT_LAST Das Ereignis ist nicht das letzte 20050214

Method EVENT_FIND_CHANGES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_FIELDS Call by reference Type reference (TYPE) GT_FIELD_TAB_TYPE geänderte Felder 20050128
2 Exporting ET_FIELDS_DIRECT Call by reference Type reference (TYPE) GT_FIELD_TAB_TYPE direkt geänderte Felder (ohne Vererbung) 20050428
3 Exporting E_EVENT_TYPE Call by reference Type reference (TYPE) IEQ_EVENT_TYPE Typ eines Events in der Equipmenthistorie 20050128
4 Exporting E_FIELD_CNT Call by reference Type reference (TYPE) IEQ_FIELD_CNT Anzahl der in einem Event geänderten Felder 20050128
5 Exporting E_INHER Call by reference Type reference (TYPE) INHER Indikator: Datenherkunft 20050128
6 Importing IS_DATA_NEW Call by reference Type reference (TYPE) GS_EQUZ_ILOA_TYPE Daten des neuen Events 20050209
7 Importing IS_DATA_OLD Call by reference Type reference (TYPE) GS_EQUZ_ILOA_TYPE Daten des alten Events 20050209
# Exception Resumable Description Created on
1 ERROR Fehler 20050128

Method EVENT_HISTORY_RELATED_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_HISTORY_ACTIVE Call by reference Type reference (TYPE) ABAP_BOOL ist die Historienfortschreibung aktiv? 20050407
2 Exporting E_HISTORY_RELEVANT Call by reference Type reference (TYPE) ABAP_BOOL wurden historienrelevante Felder geändert? 20050407
3 Exporting E_TPEIN Call by reference Type reference (TYPE) TPEIN Einbau am Technischen Platz erlaubt 20050512
4 Importing IT_FIELDS Call by reference Type reference (TYPE) GT_FIELD_TAB_TYPE Geänderte Felder 20050407
5 Importing I_EQTYP Call by reference Type reference (TYPE) EQTYP Equipmenttyp 20050407
# Exception Resumable Description Created on
1 ERROR Fehler 20050407

Method EVENT_INHERIT_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_EVENT Call by reference Type reference (TYPE) GS_EVENT_TYPE zu änderndes Ereignis 20050215
# Exception Resumable Description Created on
1 ERROR Es trat ein Fehler auf 20050211
2 INHERITANCE_ERROR Fehler bei der Vererbung 20050211
3 WRONG_EQUIPMENT Falsches übergeordnetes Equipment 20050211

Method EVENT_SET_INHERITANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_EVENT Call by reference Type reference (TYPE) GS_EVENT_TYPE Daten des Ereignisses 20050215
# Exception Resumable Description Created on
1 ERROR Fehler 20050215

Method EZBER_FILL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_EZBER Value transfer Type reference (TYPE) EQBER Technische Informationen, für SAP-interne Nutzung vorgesehen 20050405
# Exception Resumable Description Created on
1 ERROR Fehler 20050405

Method FUNC_LOC_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050401
2 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20050401
# Exception Resumable Description Created on
1 ERROR Fehler 20050401
2 FUNC_LOC_INACT Technischer Platz ist inaktiv 20050401
3 FUNC_LOC_LVORM Technischer Platz hat Löschvormerkung 20050401
4 FUNC_LOC_NOT_EXIST Technischer Platz existiert nicht 20050401
5 FUNC_LOC_NO_EQUI Der Einbau von Equipments ist nicht erlaubt 20050512

Method GOODS_MOVEMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_SL_MSG Call by reference Type reference (TYPE) IEQCM_T_MSG_SL_TYPE Erfolgsprotokoll 20050608
2 Importing IS_EVENT_NEW Call by reference Type reference (TYPE) GS_EVENT_TYPE Ereignis neu 20050608
3 Importing IS_EVENT_OLD Call by reference Type reference (TYPE) GS_EVENT_TYPE Ereignis alt 20050608
# Exception Resumable Description Created on
1 ERROR Fehler 20050608
2 GOODS_MOVEMENT_ERROR Fehler bei Structure Gaps 20050608

Method HISTORY_CHANGE_ALLOWED_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20070215
# Exception Resumable Description Created on
1 ERROR Fehler 20070215
2 HISTORY_CHANGE_NOT_ALLOWED historienrelevante Änderung nicht erlaubt 20070215

Method HISTORY_CONSISTENCY_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_CHKCNT Call by reference Type reference (TYPE) IEQCM_S_CHKCNT_TYPE Anzahl der Fehler 20050418
2 Importing I_WRITE_MSG Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Soll eine Erfolgsmeldung geschrieben werden? 20050418
# Exception Resumable Description Created on
1 ERROR Fehler 20050404
2 HISTORY_NOT_CONSISTENT Die Historie ist nicht Konsistent 20050404

Method HISTORY_EARLIER_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE_START Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050714
2 Importing I_TIME_START Call by reference Type reference (TYPE) IEQ_TIMAB Uhrzeit gültig ab 20050714
# Exception Resumable Description Created on
1 EQUIPMENT_NOT_EXISTS_ON_DATE Equipment zum Datum nicht vorhanden 20050714
2 ERROR Fehler 20050714

Method HISTORY_FROM_BACKUP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_COUNTER Call by reference Type reference (TYPE) IEQ_BACKUP Datensicherung 20050419
# Exception Resumable Description Created on
1 BACKUP_ERROR Fehler im Backup 20050419
2 BACKUP_NOT_EXIST Backup nicht gefunden 20050419
3 ERROR Fehler 20050419

Method HISTORY_FROM_TEMPLATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050315
2 Importing I_EQUNR_TEMPLATE Call by reference Type reference (TYPE) EQUNR Equipmentnummer der Vorlage 20050315
3 Importing I_TIME Call by reference Type reference (TYPE) IEQ_TIMAB Uhrzeit gültig ab 20050315
# Exception Resumable Description Created on
1 DESIRED_HISTORY_NOT_INITIAL Die Soll-Historie ist nicht initial 20050315
2 EQUIPMENT_INACT Das Equipment ist inaktiv 20050330
3 EQUIPMENT_LVORM Das Equipment hat eine Löschvormerkung 20050330
4 EQUIPMENT_NOT_EXISTS_ON_DATE Vorlageequipment nicht zur Datum vorhanden 20050315
5 EQUIPMENT_NOT_FOUND Vorlageequipment nicht gefunden 20050315
6 ERROR Fehler 20050315
7 EVENT_NOT_CONSISTENT Ein Ereignis ist nicht konsistent 20050315
8 HISTORY_INACTIVE Das Schreiben von Historiensätzen ist nicht aktiv 20050407
9 INHERITANCE_ERROR Fehler bei der Vererbung 20050315

Method HISTORY_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_HISTORY Call by reference Type reference (TYPE) IEQT_EVENT Arbeitstabelle: Ereignisse 20050314
2 Exporting E_EVENT_COUNT Call by reference Type reference (TYPE) SYTABIX Anzahl der Ereignisse 20050314
3 Importing I_LSTTYP Call by reference Type reference (TYPE) IEQ_LSTTYP Listentyp 20050314
# Exception Resumable Description Created on
1 ERROR Fehler 20050314

Method HISTORY_INHERIT_TO_DATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE Call by reference Type reference (TYPE) DATAB Datum gültig ab 20050202
2 Importing I_INCL_DATE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Vererbung auch für Ende-Datum? (nur bei Unterequipments) 20050715
3 Importing I_TIME Call by reference Type reference (TYPE) TIMBI Timestamp Equipmenteinsatz 20050202
# Exception Resumable Description Created on
1 ERROR Fehler beim Erstellen der Historie 20050202
2 WRONG_EQUIPMENT Falsches übergeordnetes Equipment 20050211

Method HISTORY_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_EQUI Call by reference Type reference (TYPE) EQUI Equipment Stammdaten 20050202
2 Exporting ET_HISTORY Call by reference Type reference (TYPE) GT_HISTORY_TYPE aktuelle Historie des Equipments 20050202
3 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050126
4 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20050202
5 Importing I_NOTIF Call by reference Type reference (TYPE) ABAP_BOOL Meldungen zu Ereignissen lesen? 20050315
6 Importing I_TIME Call by reference Type reference (TYPE) IEQ_TIMAB Uhrzeit gültig ab 20050315
# Exception Resumable Description Created on
1 EQUIPMENT_INACT Das Equipment ist inaktiv 20050330
2 EQUIPMENT_LVORM Das Equipment hat eine Löschvormerkung 20050330
3 EQUIPMENT_NOT_EXISTS_ON_DATE Equipment zum Datum nicht vorhanden 20050127
4 EQUIPMENT_NOT_FOUND Equipment existiert nicht 20050127
5 ERROR Fehler beim lesen der Historie 20050126
6 HISTORY_ERROR Fehler beim Lesen der Historie 20050127
7 HISTORY_INACTIVE Das Schreiben von Historiensätzen ist nicht aktiv 20050407

Method HISTORY_SUP_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB Datum gültig ab 20050401
2 Importing I_HEQUI Call by reference Type reference (TYPE) HEQUI Übergeordnetes Equipment 20050401
3 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20050401
# Exception Resumable Description Created on
1 ERROR Fehler beim lesen der Historie 20050401
2 FUNC_LOC_NO_EQUI Der Einbau von Equipments ist nicht erlaubt 20050512
3 HISTORY_ERROR Fehler beim Lesen der Historie 20050401
4 OBJECT_INACT übergeordnetes Objekt ist inaktiv 20050401
5 OBJECT_LVORM übergeordnetes Objekt hat eine Löschvormerkung 20050401
6 OBJECT_NOT_EXIST Übergeordnetes Objekt existiert nixgt 20050401
7 OBJECT_NOT_EXIST_ON_DATE übergeordnetes Objekt zum Datum nicht vorhanden 20050401

Method ILOAN_NUMBER_GET_NEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_ILOAN Value transfer Type reference (TYPE) ILOAN Standort und Kontierung zum technischen Objekt 20050329
# Exception Resumable Description Created on
1 ERROR Fehler 20050329

Method INHERITANCE_EXECUTE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_CHANGE_PERIODS Call by reference Type reference (TYPE) GT_PERIODS_TYPE Range der zu vererbebdeb Zeitintervalle 20050224
2 Importing IT_HEQUI_LIST Call by reference Type reference (TYPE) GT_HEQUI_LIST_TYPE Liste der übergeordneten Equipments 20050406
3 Importing IT_HISTORY_SUP Call by reference Type reference (TYPE) GT_HISTORY_TYPE Histore des übergeordneten Objekts 20050224
4 Importing IT_OBJECT_LIST_REF Call by reference Object reference (TYPE REF TO) GT_OBJECTS_TYPE Ref. auf Tabelle aller Instanzen in der Vererbung 20050712
5 Importing I_HEQUI Call by reference Type reference (TYPE) HEQUI Aufrufendes Equipment 20050225
# Exception Resumable Description Created on
1 ERROR Fehler 20050224
2 EVENT_NOT_AT_END Event nicht am Ende der Historie 20050228
3 EVENT_NOT_CONSISTENT Neues Event ist nicht Konsistent 20050228
4 EVENT_NOT_EXISTS Ereignis existiert nicht 20050228
5 INHERITANCE_ERROR Fehler bei der Vererbung 20050228
6 SUBEQUIPMENT_INHERITANCE_ERROR Fehler beim Vererben an ein Unterequipment 20050322
7 SUBEQUIPMENT_INIT_ERROR Fehler beim Instanziieren eines Unterequipments 20050322

Method INHERITANCE_START Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_CHKCNT Call by reference Type reference (TYPE) IEQCM_S_CHKCNT_TYPE Anzahl Fehler 20050418
# Exception Resumable Description Created on
1 EQUIPMENT_NOT_CONSISTENT Das Equipment ist nicht konsistent 20050404
2 ERROR 20050223
3 SUBEQUIPMENT_INHERITANCE_ERROR Fehler beim Vererben an ein Unterequipment 20050322
4 SUBEQUIPMENT_INIT_ERROR Fehler beim Instanziieren eines Unterequipments 20050223

Method INITIALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_EVENT_COUNT Call by reference Type reference (TYPE) SYTABIX Index interner Tabellen 20050316
# Exception Resumable Description Created on
1 ERROR Fehler beim Initialisieren 20050126
2 SUPERIOR_EQUIPMENT_ERROR Fehler beim Lesen des übergeordneten Equipments 20050330

Method LOCATION_TEXT_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20050216
2 Returning R_PLTXT Value transfer Type reference (TYPE) PLTXT Bezeichnung des Technischen Platzes 20050216
# Exception Resumable Description Created on
1 TEXT_NOT_FOUND Keinen Text gefunden 20050216

Method MEASUREMENTS_UPDATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_SL_MSG Call by reference Type reference (TYPE) IEQCM_T_MSG_SL_TYPE Success Nachrichten 20050407
2 Importing IT_EQUI_PERIODS Call by reference Type reference (TYPE) IEQCM_T_EQUI_PERIOD_TYPE Unterequipments & Einbauperioden 20050420
# Exception Resumable Description Created on
1 ERROR Fehler 20050401
2 MEASUREMENT_OLD_SAVE_ERROR Fehler beim Sichern der alten Meßwerte 20050401

Method MESSAGES_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_REFRESH Call by reference Type reference (TYPE) ABAP_BOOL ABAP_ON Soll Nachrichtentabelle geleert werden? 20050314
2 Returning RT_MSG Value transfer Type reference (TYPE) IEQT_MSG Hilfstabelle für Nachrichten-/Erfolgsprotokoll 20050322
# Exception Resumable Description Created on
1 ERROR Fehler 20050314

Method MESSAGE_ADD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_MSGID Call by reference Type reference (TYPE) SYMSGID IEQCM_CS_MSGID-IEQ Nachrichtenklasse 20050316
2 Importing I_MSGNO Call by reference Type reference (TYPE) SYMSGNO Nachrichtennummer 20050316
3 Importing I_MSGTYP Call by reference Type reference (TYPE) SYMSGTY IEQCM_CS_MSGTYP-ERROR Nachrichtentyp 20050316
4 Importing I_MSGV1 Call by reference Type reference (TYPE) ANY Nachrichtenvariable 1 20050316
5 Importing I_MSGV2 Call by reference Type reference (TYPE) ANY Nachrichtenvariable 2 20050316
6 Importing I_MSGV3 Call by reference Type reference (TYPE) ANY Nachrichtenvariable 3 20050316
7 Importing I_MSGV4 Call by reference Type reference (TYPE) ANY Nachrichtenvariable 4 20050316
8 Importing I_TRACE Call by reference Type reference (TYPE) XFELD Nachricht für Trace 20050316
# Exception Resumable Description Created on
1 ERROR Fehler 20050316

Method STRUCTUR_GAP_HANDLING Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_SL_MSG Call by reference Type reference (TYPE) IEQCM_T_MSG_SL_TYPE Erfolgsprotokoll 20050608
2 Importing IS_EVENT_NEW Call by reference Type reference (TYPE) GS_EVENT_TYPE Ereignis neu 20050608
3 Importing IS_EVENT_OLD Call by reference Type reference (TYPE) GS_EVENT_TYPE Ereignis alt 20050608
# Exception Resumable Description Created on
1 ERROR Fehler 20050608
2 STRUCTUR_GAP_ERROR Fehler bei Structure Gaps 20050608

Method SUBEQUIPMENTS_FIND Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE_END Call by reference Type reference (TYPE) DATBI GC_DATE_NOW Enddatum der Suche 20050222
2 Importing I_DATE_START Call by reference Type reference (TYPE) DATAB Startdatum der Suche 20050222
3 Importing I_TIME_END Call by reference Type reference (TYPE) TIMBI Endzeit der Suche 20050222
4 Importing I_TIME_START Call by reference Type reference (TYPE) IEQ_TIMAB Startzeit der Suche 20050222
# Exception Resumable Description Created on
1 ERROR Fehler 20050222
2 WRONG_DATE Falsche Datumsangabe 20050222

Method TEST_EVENT_ADD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_DATE Call by reference Type reference (TYPE) IEQ_DATAB SY-DATUM Datum gültig ab 20050214
2 Importing I_EVENT_TYPE Call by reference Type reference (TYPE) IEQ_EVENT_TYPE Ereignistyp 20050324
3 Importing I_FIELDNAME Call by reference Type reference (TYPE) FIELDNAME zu änderndes Feld 20050214
4 Importing I_HEQUI Call by reference Type reference (TYPE) HEQUI Übergeordnetes Equipment 20050324
5 Importing I_TIME Call by reference Type reference (TYPE) IEQ_TIMAB SY-UZEIT Uhrzeit gültig ab 20050214
6 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20050324
7 Importing I_VALUE Call by reference Type reference (TYPE) CHAR40 Feldinhalt 20050214
# Exception Resumable Description Created on
1 ERROR Fehler 20050214

Method WORKLIST_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_WL_HEADER Call by reference Type reference (TYPE) IEQT_WL_HEADER Zwischenstände - Kopfdaten 20050318
2 Exporting ET_WL_ITEMS Call by reference Type reference (TYPE) IEQCM_T_WL_ITEMS_TYPE Arbeitstabelle 20050318
3 Exporting E_EVENT_COUNT Call by reference Type reference (TYPE) SYTABIX Anzahl der Ereignisse 20050318
# Exception Resumable Description Created on
1 ERROR Fehler 20050318

Method WORKLIST_HEADER_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RS_WL_HEADER Value transfer Type reference (TYPE) IEQT_WL_HEADER Zwischenstände - Kopfdaten 20050318
# Exception Resumable Description Created on
1 ERROR Fehler 20050318

Method WORKLIST_READ Signature

Method WORKLIST_READ on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# Exception Resumable Description Created on
1 ERROR Fehler 20050321
2 WORKLIST_NOT_CONSISTENT Die Zwischensicherung ist nicht konsistent 20050321

Method WORKLIST_UPDATE_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_CHANGED Value transfer Type reference (TYPE) ABAP_BOOL 20050405
# Exception Resumable Description Created on
1 ERROR Fehler 20050406
History
Last changed by/on SAP  20100310 
SAP Release Created in 600