Hierarchy
⤷ PM-EQM-EQ (Application Component) Equipment
⤷ IEQCM_BE (Package) Change of Equipment History - Backend
Properties
Class | CL_IEQCM_BE_EQUIPMENT | |
Short Description | Class for Equipment (Change of History) | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | P | SAP Standard Production Program |
Category | 0 | |
Package | IEQCM_BE | Change of Equipment History - Backend |
Created | 20050126 | SAP |
Last change | 20100310 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ABAP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | GTYPE | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
3 | IEQCM | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | ITOB | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_IEQCM_BE_EQUIPMENT has no interface implemented.
Friends
Class CL_IEQCM_BE_EQUIPMENT has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | GC_DATE_NOW | Constant | Private | Type reference (TYPE) | DATBI | '99991231' | Last Date | 20050201 | |
2 | GS_EQUI | Instance attribute | Private | Type reference (TYPE) | EQUI | Equipment Master Data | 20050127 | ||
3 | GS_EVENT_TEMP | Instance attribute | Private | Type reference (TYPE) | GS_EVENT_TYPE | Temporary Event (Template for New Event) | 20050322 | ||
4 | GS_WL_HEADER | Instance attribute | Private | Type reference (TYPE) | IEQT_WL_HEADER | Header Data of Current Interim Save | 20050321 | ||
5 | GT_CHANGE_PERIODS | Instance attribute | Private | Type reference (TYPE) | GT_PERIODS_TYPE | Table of Changed Time Intervals | 20050224 | ||
6 | GT_FIELDLIST | Static Attribute | Private | Type reference (TYPE) | GT_FIELDLIST_TYPE | Field List of Data Fields | 20050210 | ||
7 | GT_HEQUI_LIST | Instance attribute | Private | Type reference (TYPE) | GT_HEQUI_LIST_TYPE | Table of Superordinate Equipment (Only for Inheritance) | 20050406 | ||
8 | GT_HISTORY_NEW | Instance attribute | Private | Type reference (TYPE) | GT_HISTORY_TYPE | New History of an Equipment | 20050202 | ||
9 | GT_HISTORY_OLD | Instance attribute | Private | Type reference (TYPE) | GT_HISTORY_TYPE | Current History of an Equipment | 20050202 | ||
10 | GT_HISTORY_SUP | Instance attribute | Private | Type reference (TYPE) | GT_HISTORY_TYPE | History of Superordinate Equipment (only for Start Equip.) | 20050204 | ||
11 | GT_HISTORY_SUP_REF | Instance attribute | Private | Object reference (TYPE REF TO) | GT_HISTORY_TYPE | Reference to History of Superordinate Equip. | 20050225 | ||
12 | GT_INSTANCES | Instance attribute | Private | Type reference (TYPE) | GT_OBJECTS_TYPE | Table with Equipment Instances | 20050202 | ||
13 | GT_MESSAGES | Instance attribute | Private | Type reference (TYPE) | IEQT_MSG | Current Messages | 20050314 | ||
14 | GT_OBJECT_LIST_REF | Instance attribute | Private | Object reference (TYPE REF TO) | GT_OBJECTS_TYPE | Ref. to Table of All Instances of an Inheritance | 20050712 | ||
15 | GT_SUBEQUI_PERIODS | Instance attribute | Private | Type reference (TYPE) | GT_PERIODS_TYPE | Periods for Which Subequipments are Searched for | 20050714 | ||
16 | G_ASSET_ACTIVE | Static Attribute | Private | Type reference (TYPE) | ABAP_BOOL | 20050608 | |||
17 | G_BADI_CHECK | Static Attribute | Private | Object reference (TYPE REF TO) | IF_EX_IEQCM_BE_CHECK | BAdI Interface IF_EX_IEQCM_BE_CHECK | 20050401 | ||
18 | G_BADI_DECOUPLING | Static Attribute | Private | Object reference (TYPE REF TO) | IF_EX_IEQCM_BE_DECOUPLING | BADI Interface IF_EX_IEQCM_BE_DECOUPLING | 20050315 | ||
19 | G_DATE_CHANGE | Static Attribute | Private | Type reference (TYPE) | AEDAT | Date for the Changes | 20050222 | ||
20 | G_DATE_CURRENT | Instance attribute | Private | Type reference (TYPE) | DATBI | Current Date | 20050207 | ||
21 | G_DATE_LAST | Instance attribute | Public | Type reference (TYPE) | DATBI | Date of the Last Direct Event | 20050217 | ||
22 | G_DATE_START | Instance attribute | Private | Type reference (TYPE) | IEQ_DATAB | Start Date of Change | 20050217 | ||
23 | G_DB_UPDATED | Instance attribute | Private | Type reference (TYPE) | ABAP_BOOL | The changes were posted -> No further changes | 20050324 | ||
24 | G_EQUNR | Instance attribute | Public | Type reference (TYPE) | EQUNR | Equipment Number of Instance | 20050126 | ||
25 | G_EZBER | Static Attribute | Private | Type reference (TYPE) | EQBER | Technical information, intended for SAP internal use | 20050405 | ||
26 | G_INDEX_LAST_EVENT | Instance attribute | Private | Type reference (TYPE) | SYTABIX | Index of Last Event in New History | 20050202 | ||
27 | G_INHERITANCE_OK | Instance attribute | Private | Type reference (TYPE) | ABAP_BOOL | The changes were inherited successfully | 20050331 | ||
28 | G_INSTALL_CURRENT | Instance attribute | Public | Type reference (TYPE) | ABAP_BOOL | Is equipment currently installed? | 20050317 | ||
29 | G_LOCKED | Instance attribute | Public | Type reference (TYPE) | ABAP_BOOL | Lock Status of Equipment | 20050126 | ||
30 | G_START_EQUIPMENT | Instance attribute | Private | Type reference (TYPE) | ABAP_BOOL | Equipment is Access Equipment | 20050126 | ||
31 | G_TIME_CURRENT | Instance attribute | Private | Type reference (TYPE) | TIMBI | Current Time | 20050207 | ||
32 | G_TIME_LAST | Instance attribute | Public | Type reference (TYPE) | TIMBI | Time of Last Direct Event | 20050217 | ||
33 | G_TIME_START | Instance attribute | Private | Type reference (TYPE) | IEQ_TIMAB | Start Time of Change | 20050217 | ||
34 | G_UNAME | Static Attribute | Private | Type reference (TYPE) | SYUNAME | User Name for the Changes | 20050222 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | BACKUP_COUNTER_GET_NEXT | Static method | Private | Method | Gets Next Backup Counter | 20050603 |
2 | CLASS_CONSTRUCTOR | Static method | Public | Constructor | CLASS_CONSTRUCTOR | 20050209 |
3 | CONSTRUCTOR | Instance method | Public | Constructor | CONSTRUCTOR | 20050126 |
4 | DB_REALIZE | Instance method | Public | Method | Writes the Changes to the Database | 20050324 |
5 | DB_TABLES_FILL | Instance method | Private | Method | Fills the Tables for the Database Update | 20050322 |
6 | DETAIL_CHECK | Instance method | Public | Method | Checks Entries on the Detail Screen and Fills Dependent Flds | 20050622 |
7 | DETAIL_GET_FOR_COPY | Instance method | Public | Method | Copies Changes of an Old Event into Target History | 20050215 |
8 | DETAIL_GET_FOR_CREATE | Instance method | Public | Method | Detail for Time for Creation of a New Event | 20050322 |
9 | DETAIL_GET_FOR_DISPLAY | Instance method | Public | Method | Detail for Time | 20050322 |
10 | EQUIPMENTTYPE_TEXT_READ | Static method | Public | Method | Reads Texts for Equipment Category | 20050318 |
11 | EQUIPMENT_ADDRESS_CHANGE | Static method | Private | Method | Changes Address of Equipment | 20050524 |
12 | EQUIPMENT_AUTHORITY_CHECK | Instance method | Private | Method | Authorization Check | 20050201 |
13 | EQUIPMENT_CONSISTENCY_CHECK | Instance method | Public | Method | Consistency Check for an Equipment | 20050126 |
14 | EQUIPMENT_CRM_UPDATE | Instance method | Private | Method | Transfers the Change to a CRM System | 20050609 |
15 | EQUIPMENT_LOCK | Instance method | Public | Method | Lock Equipment | 20050126 |
16 | EQUIPMENT_STATUS_CHANGE_DISM | Instance method | Private | Method | Set System Status for Dismantled | 20050504 |
17 | EQUIPMENT_STATUS_CHANGE_INST | Instance method | Private | Method | Set System Status for Installed | 20050504 |
18 | EQUIPMENT_STATUS_RESET | Static method | Public | Method | Removes Status for History Change | 20050324 |
19 | EQUIPMENT_STATUS_SET | Static method | Public | Method | Sets Status for History Change | 20050323 |
20 | EQUIPMENT_TEXT_READ | Static method | Public | Method | Reads the Short Text for an Equipment | 20050216 |
21 | EQUIPMENT_UNLOCK | Instance method | Public | Method | Locks Equipment | 20050201 |
22 | EVENT_ADD | Instance method | Public | Method | Attaches New Event (Direct Change) | 20050126 |
23 | EVENT_CHANGE | Instance method | Public | Method | Changes Event | 20050318 |
24 | EVENT_CONSISTENCY_CHECK | Instance method | Private | Method | Executes Consistency Check for an Event | 20050126 |
25 | EVENT_COPY_MULTIPLE | Instance method | Public | Method | Copies a Sequence of Events into the Target History | 20050316 |
26 | EVENT_DELETE | Instance method | Public | Method | Deletes an Event (and All Subsequent Events) | 20050126 |
27 | EVENT_FIND_CHANGES | Static method | Private | Method | What changed in the event? | 20050128 |
28 | EVENT_HISTORY_RELATED_CHECK | Static method | Private | Method | Checks if History-Relevant Fields Were Changed | 20050407 |
29 | EVENT_INHERIT_DATA | Instance method | Private | Method | Inherit Data for an Event from the Superordinate Object | 20050211 |
30 | EVENT_SET_INHERITANCE | Instance method | Private | Method | Sets the Inheritance Indicator for an Event | 20050215 |
31 | EZBER_FILL | Static method | Private | Method | Fills Check-Info (Same Here for All Equipment Usage Periods) | 20050405 |
32 | FUNC_LOC_READ | Instance method | Private | Method | Reads Superordinate Functional Location | 20050401 |
33 | GOODS_MOVEMENT | Instance method | Private | Method | Triggers Goods Movement | 20050608 |
34 | HISTORY_CHANGE_ALLOWED_CHECK | Instance method | Private | Method | Checks Whether History-Relevant Changes are Allowed | 20070215 |
35 | HISTORY_CONSISTENCY_CHECK | Instance method | Public | Method | Checks the Consistency of Target History | 20050404 |
36 | HISTORY_EARLIER_READ | Instance method | Public | Method | Read History of Equipment for Earlier Start Date | 20050714 |
37 | HISTORY_FROM_BACKUP | Instance method | Private | Method | Fill Target History from Backup | 20050419 |
38 | HISTORY_FROM_TEMPLATE | Instance method | Private | Method | Fill Target History Using Template Equipment | 20050315 |
39 | HISTORY_GET | Instance method | Public | Method | Returns the Desired History | 20050314 |
40 | HISTORY_INHERIT_TO_DATE | Instance method | Private | Method | Inherit Target History by Date | 20050202 |
41 | HISTORY_READ | Static method | Private | Method | Read Actual History for Equipment | 20050126 |
42 | HISTORY_SUP_READ | Instance method | Private | Method | Reading History of the Superordinate Object | 20050401 |
43 | ILOAN_NUMBER_GET_NEXT | Static method | Public | Method | Getting Next ILOAN Number | 20050329 |
44 | INHERITANCE_EXECUTE | Instance method | Private | Method | Performing the Inheritance for an Equipment | 20050223 |
45 | INHERITANCE_START | Instance method | Public | Method | Starting the Inheritance of the Changed History | 20050223 |
46 | INITIALIZE | Instance method | Public | Method | Initialize Instance (Delete Target History) | 20050126 |
47 | LOCATION_TEXT_READ | Static method | Public | Method | Reads Short Text for Functional Location | 20050216 |
48 | MEASUREMENTS_UPDATE | Instance method | Private | Method | Triggers Measurement Document Changes | 20050401 |
49 | MESSAGES_GET | Instance method | Public | Method | Gets Messages | 20050314 |
50 | MESSAGE_ADD | Instance method | Private | Method | Attaches a Message to the Log | 20050316 |
51 | STRUCTUR_GAP_HANDLING | Instance method | Private | Method | Checks Structure Gaps | 20050608 |
52 | SUBEQUIPMENTS_FIND | Instance method | Private | Method | Finds Direct Subordinate Equipments | 20050222 |
53 | TEST_EVENT_ADD | Instance method | Public | Method | Test Method: EVENT_ADD | 20050214 |
54 | WORKLIST_GET | Instance method | Public | Method | Returns the Work Table (For Example, for Saving) | 20050318 |
55 | WORKLIST_HEADER_GET | Instance method | Public | Method | Returns the Header of the Work Table | 20050318 |
56 | WORKLIST_READ | Instance method | Public | Method | Reads the Saved Interim Version for the Equipment | 20050321 |
57 | WORKLIST_UPDATE_CHECK | Instance method | Public | Method | Checks Whether the Target History Was Changed | 20050405 |
Events
Class CL_IEQCM_BE_EQUIPMENT has no event.
Types
Class CL_IEQCM_BE_EQUIPMENT has no local type.
Method Signatures
Method BACKUP_COUNTER_GET_NEXT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_COUNTER | Call by reference | Type reference (TYPE) | IEQ_BACKUP | Datensicherung | 20050603 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | COUNTER_LOCKED | Der Counter ist gesperrt -> später erneut versuchen | 20050603 | |
2 | ERROR | Fehler | 20050603 |
Method CLASS_CONSTRUCTOR Signature
Method CLASS_CONSTRUCTOR on class CL_IEQCM_BE_EQUIPMENT has no parameter.
Method CLASS_CONSTRUCTOR on class CL_IEQCM_BE_EQUIPMENT has no exception.
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_COUNTER | Call by reference | Type reference (TYPE) | IEQ_BACKUP | Datensicherung | 20050419 | ||
2 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050126 | ||
3 | Importing | I_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer | 20050126 | ||
4 | Importing | I_EQUNR_TEMPLATE | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer der Vorlage | 20050316 | ||
5 | Importing | I_START_EQUIPMENT | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_ON | Das Equipment ist ein Einstiegsequipment (von außen gerufen) | 20050317 | |
6 | Importing | I_TIME | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Uhrzeit gültig ab | 20050315 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | BACKUP_ERROR | Fehler beim Backup | 20050419 | |
2 | BACKUP_NOT_EXIST | Backup nicht gefunden | 20050419 | |
3 | EQUIPMENT_INACT | Das Equipment ist inaktiv | 20050330 | |
4 | EQUIPMENT_LVORM | Das Equipment hat eine Löschvormerkung | 20050330 | |
5 | EQUIPMENT_NOT_EXISTS_ON_DATE | Equipment zum Datum nicht vorhanden | 20050127 | |
6 | EQUIPMENT_NOT_FOUND | Equipment existiert nicht | 20050126 | |
7 | ERROR | Fehler beim lesen der Historie | 20050127 | |
8 | HISTORY_CHANGE_NOT_ALLOWED | historienrelevante Änderung nicht erlaubt | 20070228 | |
9 | HISTORY_ERROR | Fehler beim Lesen der Historie | 20050127 | |
10 | HISTORY_INACTIVE | Das Schreiben von Historiensätzen ist nicht aktiv | 20050407 | |
11 | LOCK_ERROR | Fehler beim Sperren | 20050201 | |
12 | NO_AUTHORITY | keine Berechtigung | 20050201 | |
13 | SUPERIOR_EQUIPMENT_ERROR | Fehler beim Lesen des übergeordneten Equipments | 20050330 | |
14 | TEMPLATE_ERROR | Fehler beim Kopieren der Historie von der Vorlage | 20050316 | |
15 | TEMPLATE_NOT_EXIST | Vorlage nicht gefunden | 20050316 |
Method DB_REALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_SL_MSG | Call by reference | Type reference (TYPE) | IEQCM_T_MSG_SL_TYPE | Erfolgsprotokoll | 20050404 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | COUNTER_LOCKED | Der Counter ist gesperrt -> später erneut versuchen | 20050603 | |
2 | ERROR | Fehler | 20050324 | |
3 | GOODS_MOVEMENT_ERROR | Fehler bei Warenbewegungen | 20050404 | |
4 | MEASUREMENT_ERROR | Fehler beim Ändern der Meßwerte | 20050401 | |
5 | STRUCTUR_GAP_ERROR | Fehler bei Structure Gaps | 20050404 | |
6 | SUBEQUIPMENT_INHERITANCE_ERROR | Fehler beim Vererben an ein Unterequipment | 20050331 | |
7 | SUBEQUIPMENT_INIT_ERROR | Fehler beim Instanziieren eines Unterequipments | 20050331 |
Method DB_TABLES_FILL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_EQUI_CHANGE | Call by reference | Type reference (TYPE) | IEQCM_T_EQUI_TYPE | Tabelle für EQUI update | 20050429 | ||
2 | Exporting | ET_EQUI_OLD | Call by reference | Type reference (TYPE) | IEQCM_T_EQUI_TYPE | Tabelle mit originalen EQUI Daten | 20050429 | ||
3 | Exporting | ET_EQUI_PERIODS | Call by reference | Type reference (TYPE) | IEQCM_T_EQUI_PERIOD_TYPE | Tabelle der Einbauperioden des Equipments | 20050420 | ||
4 | Exporting | ET_EQUZ_CHANGE | Call by reference | Type reference (TYPE) | IEQCM_T_EQUZ_TYPE | Tabelle für EQUZ Update | 20050329 | ||
5 | Exporting | ET_EQUZ_DELETE | Call by reference | Type reference (TYPE) | IEQCM_T_EQUZ_TYPE | Tabelle für EQUZ Update | 20050329 | ||
6 | Exporting | ET_EQUZ_INSERT | Call by reference | Type reference (TYPE) | IEQCM_T_EQUZ_TYPE | Tabelle für EQUZ Update | 20050329 | ||
7 | Exporting | ET_ILOA_CHANGE | Call by reference | Type reference (TYPE) | IEQCM_T_ILOA_TYPE | Tabelle für ILOA Update | 20050329 | ||
8 | Exporting | ET_ILOA_DELETE | Call by reference | Type reference (TYPE) | IEQCM_T_ILOA_TYPE | Tabelle für ILOA Update | 20050329 | ||
9 | Exporting | ET_ILOA_INSERT | Call by reference | Type reference (TYPE) | IEQCM_T_ILOA_TYPE | Tabelle für ILOA Update | 20050329 | ||
10 | Exporting | ET_WL_ITEMS_BACK | Call by reference | Type reference (TYPE) | IEQCM_T_WL_ITM_BAC_TYPE | Tabelle für Backup der alten und neuen Historie | 20050331 | ||
11 | Importing | IT_OBJECT_LIST_REF | Call by reference | Object reference (TYPE REF TO) | GT_OBJECTS_TYPE | Ref. auf Tabelle aller Instanzen in der Vererbung | 20050715 | ||
12 | Importing | I_BACKUP_COUNTER | Call by reference | Type reference (TYPE) | I_COUNT | Zähler für den Backup (Schlüssel) | 20050331 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050322 |
Method DETAIL_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_DETAIL | Call by reference | Type reference (TYPE) | IEQS_EVENT | Arbeitstabelle: Ereignisse | 20050622 | ||
2 | Exporting | ET_FIELDS | Call by reference | Type reference (TYPE) | IEQCM_T_FIELD_TYPE | geänderte Felder | 20050622 | ||
3 | Exporting | E_CHANGED | Call by reference | Type reference (TYPE) | ABAP_BOOL | Indikator ob Felder vom system geändert wurden | 20050622 | ||
4 | Importing | IS_DETAIL | Call by reference | Type reference (TYPE) | IEQS_EVENT | Arbeitstabelle: Ereignisse | 20050622 | ||
5 | Importing | IS_ITOBEXT | Call by reference | Type reference (TYPE) | ITOBEXT | Technische Objekte PM: Daten mit externer Sicht | 20050622 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050622 | |
2 | EVENT_NOT_CONSISTENT | Eingabe Fehlerhaft | 20050622 |
Method DETAIL_GET_FOR_COPY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_DETAIL | Call by reference | Type reference (TYPE) | IEQS_EVENT | Arbeitstabelle: Ereignisse | 20050215 | ||
2 | Exporting | ET_FIELDS | Call by reference | Type reference (TYPE) | IEQCM_T_FIELD_TYPE | geänderte Felder | 20050215 | ||
3 | Importing | I_DATE_NEW | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum des neuen Ereignisses | 20050215 | ||
4 | Importing | I_DATE_OLD | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum des Originalereignisses | 20050215 | ||
5 | Importing | I_TIME_NEW | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Zeitpunkt des neuen Ereignisses | 20050215 | ||
6 | Importing | I_TIME_OLD | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Zeitpunkt des Originalereignisses | 20050215 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050215 | |
2 | EVENT_NOT_AT_END | Event nicht am Ende der Historie | 20050217 | |
3 | EVENT_NOT_EXISTS | Ereignis existiert nicht | 20050215 | |
4 | EVENT_TYPE_NOT_ALLOWED | Der Ereignistyp ist nicht erlaubt | 20050323 | |
5 | INHERITANCE_ERROR | Fehler bei der Vererbung vom übergeordneten Objekt | 20050323 |
Method DETAIL_GET_FOR_CREATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_DETAIL | Call by reference | Type reference (TYPE) | IEQS_EVENT | E/A-Struktur: Detailbild | 20050322 | ||
2 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050322 | ||
3 | Importing | I_EVENT_TYPE | Call by reference | Type reference (TYPE) | IEQ_EVENT_TYPE | Ereignistyp | 20050322 | ||
4 | Importing | I_HEQUI | Call by reference | Type reference (TYPE) | HEQUI | Übergeordnetes Equipment | 20050322 | ||
5 | Importing | I_TIME | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Uhrzeit gültig ab | 20050322 | ||
6 | Importing | I_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20050322 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050322 | |
2 | EVENT_NOT_AT_END | Ereignis nicht am Ende der Historie | 20050322 | |
3 | EVENT_TYPE_NOT_ALLOWED | Der Ereignistyp ist nicht erlaubt | 20050322 | |
4 | INHERITANCE_ERROR | Fehler bei der Vererbung vom übergeordneten Objekt | 20050322 |
Method DETAIL_GET_FOR_DISPLAY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_DETAIL | Call by reference | Type reference (TYPE) | IEQS_EVENT | E/A-Struktur: Detailbild | 20050322 | ||
2 | Exporting | ET_FIELDS | Call by reference | Type reference (TYPE) | IEQCM_T_FIELD_TYPE | geänderte Felder | 20050322 | ||
3 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050322 | ||
4 | Importing | I_LSTTYP | Call by reference | Type reference (TYPE) | IEQ_LSTTYP | alte oder neue Historie | 20050322 | ||
5 | Importing | I_TIME | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Uhrzeit gültig ab | 20050322 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050322 | |
2 | EVENT_NOT_EXISTS | Ereignis existiert nicht | 20050322 |
Method EQUIPMENTTYPE_TEXT_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_EQTYP | Call by reference | Type reference (TYPE) | EQTYP | Equipmenttyp | 20050318 | ||
2 | Importing | I_LANGU | Call by reference | Type reference (TYPE) | SYLANGU | SY-LANGU | Sprachenschlüssel | 20050318 | |
3 | Returning | R_TYPTX | Value transfer | Type reference (TYPE) | TYPTX | Bezeichnung Technischer Typ | 20050318 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | TEXT_NOT_FOUND | Keinen text gefunden | 20050318 |
Method EQUIPMENT_ADDRESS_CHANGE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_ADRNRI_OLD | Call by reference | Type reference (TYPE) | INH_ADRNRI | Datenherkunft für Feld 'Adresse' | 20050601 | ||
2 | Importing | I_ADRNR_NEW | Call by reference | Type reference (TYPE) | AD_ADDRNUM | Adreßnummer neu | 20050524 | ||
3 | Importing | I_ADRNR_OLD | Call by reference | Type reference (TYPE) | AD_ADDRNUM | Adreßnummer alt | 20050524 | ||
4 | Importing | I_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer | 20050524 | ||
5 | Importing | I_UPDATE_MODE | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_TRUE | Änderungen werden verbucht | 20050621 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050524 |
Method EQUIPMENT_AUTHORITY_CHECK Signature
Method EQUIPMENT_AUTHORITY_CHECK on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050201 | |
2 | NO_AUTHORITY | keine Berechtigung | 20050201 |
Method EQUIPMENT_CONSISTENCY_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_CHKCNT | Call by reference | Type reference (TYPE) | IEQCM_S_CHKCNT_TYPE | Anzahl der Fehler | 20050418 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | EQUIPMENT_NOT_CONSISTENT | Das Equipment enhält Inconsistenzen | 20050126 | |
2 | ERROR | Fehler | 20050404 |
Method EQUIPMENT_CRM_UPDATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_SL_MSG | Call by reference | Type reference (TYPE) | IEQCM_T_MSG_SL_TYPE | Erfolgsprotokoll | 20050609 | ||
2 | Importing | IT_EQUI_NEW | Call by reference | Type reference (TYPE) | IEQCM_T_EQUI_TYPE | Equipment Stammdaten neu | 20050609 | ||
3 | Importing | IT_EQUI_OLD | Call by reference | Type reference (TYPE) | IEQCM_T_EQUI_TYPE | Equipment Stammdaten alt | 20050609 | ||
4 | Importing | IT_WL_ITEMS_BACK | Call by reference | Type reference (TYPE) | IEQCM_T_WL_ITM_BAC_TYPE | Backup - alte und neue Historiendaten | 20050609 | ||
5 | Importing | I_DATE_START | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050609 | ||
6 | Importing | I_TIME_START | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Uhrzeit gültig ab | 20050609 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050609 |
Method EQUIPMENT_LOCK Signature
Method EQUIPMENT_LOCK on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | LOCK_ERROR | Fehler beim Sperren | 20050201 |
Method EQUIPMENT_STATUS_CHANGE_DISM Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_HEQUI | Call by reference | Type reference (TYPE) | HEQUI | Übergeordnetes Equipment | 20050504 | ||
2 | Importing | I_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20050504 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050504 |
Method EQUIPMENT_STATUS_CHANGE_INST Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_HEQUI | Call by reference | Type reference (TYPE) | HEQUI | Übergeordnetes Equipment | 20050504 | ||
2 | Importing | I_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20050504 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050504 |
Method EQUIPMENT_STATUS_RESET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DB_COMMIT | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_FALSE | auf Datenbank verbuchen? | 20050404 | |
2 | Importing | I_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer | 20050324 | ||
3 | Importing | I_OBJNR | Call by reference | Type reference (TYPE) | J_OBJNR | Objektnummer | 20050404 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050324 | |
2 | STATUS_NOT_SET | Status für Equipment nicht gesetzt | 20050404 |
Method EQUIPMENT_STATUS_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DB_COMMIT | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_FALSE | Auf Datenbank verbuchen? | 20050404 | |
2 | Importing | I_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer | 20050323 | ||
3 | Importing | I_OBJNR | Call by reference | Type reference (TYPE) | J_OBJNR | Objektnummer | 20050404 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050323 |
Method EQUIPMENT_TEXT_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer | 20050216 | ||
2 | Returning | R_EQKTX | Value transfer | Type reference (TYPE) | KTX01 | Bezeichnung technisches Objekt | 20050216 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | TEXT_NOT_FOUND | Keinen Text gefunden | 20050216 |
Method EQUIPMENT_UNLOCK Signature
Method EQUIPMENT_UNLOCK on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | LOCK_ERROR | Fehler beim Sperren | 20050201 |
Method EVENT_ADD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IS_DETAIL | Call by reference | Type reference (TYPE) | IEQS_EVENT | Arbeitstabelle: Ereignisse | 20050215 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler beim anhängen eines Ereignisses | 20050126 | |
2 | EVENT_NOT_AT_END | Ereignis nicht am Ende der Historie | 20050214 | |
3 | EVENT_NOT_CONSISTENT | Neues Ereignis ist nicht Konsistent | 20050211 | |
4 | INHERITANCE_ERROR | Fehler bei der Vererbung | 20050210 | |
5 | NOTHING_CHANGED | Es hat sich nichts geändert, es wird kein Ereignis angehängt | 20050303 | |
6 | NO_CHANGES_ALLOWED | Keine weiteren Änderungen erlaubt | 20050324 |
Method EVENT_CHANGE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IS_EVENT | Call by reference | Type reference (TYPE) | IEQS_EVENT | Ereignis | 20050318 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CHANGE_NOT_ALLOWED | Die Änderungen sind nicht erlaubt | 20050318 | |
2 | ERROR | Fehler | 20050318 | |
3 | EVENT_NOT_CONSISTENT | Das Ereignis ist nicht konsistent | 20050318 | |
4 | EVENT_NOT_EXISTS | Das Ereignis existiert nicht | 20050321 |
Method EVENT_CONSISTENCY_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_WARNING | Call by reference | Type reference (TYPE) | ABAP_BOOL | Ereignis hat Warnung | 20050504 | ||
2 | Importing | IS_EVENT | Call by reference | Type reference (TYPE) | GS_EVENT_TYPE | Zu prüfender Event | 20050211 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050211 | |
2 | EVENT_NOT_CONSISTENT | Der Event enthält Inkonststenzen | 20050126 |
Method EVENT_COPY_MULTIPLE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_EVENT_COUNT | Call by reference | Type reference (TYPE) | SYTABIX | Anzahl der kopierten Ereignisse | 20050317 | ||
2 | Importing | I_DATE_END | Call by reference | Type reference (TYPE) | DATBI | '99991231' | Enddatum | 20050316 | |
3 | Importing | I_DATE_START | Call by reference | Type reference (TYPE) | IEQ_DATAB | Startdatum | 20050316 | ||
4 | Importing | I_TIME_END | Call by reference | Type reference (TYPE) | TIMBI | Endzeit | 20050316 | ||
5 | Importing | I_TIME_START | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Startzeit | 20050316 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler beim anhängen eines Events | 20050316 | |
2 | EVENT_NOT_AT_END | Event nicht am Ende der Historie | 20050316 | |
3 | EVENT_NOT_CONSISTENT | Neues Event ist nicht Konsistent | 20050316 | |
4 | EVENT_NOT_EXISTS | Ereignis existiert nicht | 20050316 | |
5 | EVENT_TYPE_NOT_ALLOWED | Der Ereignistyp ist nicht erlaubt | 20050323 | |
6 | INHERITANCE_ERROR | Fehler bei der Vererbung | 20050316 |
Method EVENT_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum des Events | 20050214 | ||
2 | Importing | I_LAST_EVENT | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_ON | nur das letzte 'manuelle' Ereignis | 20050214 | |
3 | Importing | I_TIME | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Zeit des Events | 20050214 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler beim Löschen des Events | 20050126 | |
2 | EVENT_NOT_EXISTS | Der Event existiert nicht | 20050214 | |
3 | EVENT_NOT_LAST | Das Ereignis ist nicht das letzte | 20050214 |
Method EVENT_FIND_CHANGES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_FIELDS | Call by reference | Type reference (TYPE) | GT_FIELD_TAB_TYPE | geänderte Felder | 20050128 | ||
2 | Exporting | ET_FIELDS_DIRECT | Call by reference | Type reference (TYPE) | GT_FIELD_TAB_TYPE | direkt geänderte Felder (ohne Vererbung) | 20050428 | ||
3 | Exporting | E_EVENT_TYPE | Call by reference | Type reference (TYPE) | IEQ_EVENT_TYPE | Typ eines Events in der Equipmenthistorie | 20050128 | ||
4 | Exporting | E_FIELD_CNT | Call by reference | Type reference (TYPE) | IEQ_FIELD_CNT | Anzahl der in einem Event geänderten Felder | 20050128 | ||
5 | Exporting | E_INHER | Call by reference | Type reference (TYPE) | INHER | Indikator: Datenherkunft | 20050128 | ||
6 | Importing | IS_DATA_NEW | Call by reference | Type reference (TYPE) | GS_EQUZ_ILOA_TYPE | Daten des neuen Events | 20050209 | ||
7 | Importing | IS_DATA_OLD | Call by reference | Type reference (TYPE) | GS_EQUZ_ILOA_TYPE | Daten des alten Events | 20050209 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050128 |
Method EVENT_HISTORY_RELATED_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_HISTORY_ACTIVE | Call by reference | Type reference (TYPE) | ABAP_BOOL | ist die Historienfortschreibung aktiv? | 20050407 | ||
2 | Exporting | E_HISTORY_RELEVANT | Call by reference | Type reference (TYPE) | ABAP_BOOL | wurden historienrelevante Felder geändert? | 20050407 | ||
3 | Exporting | E_TPEIN | Call by reference | Type reference (TYPE) | TPEIN | Einbau am Technischen Platz erlaubt | 20050512 | ||
4 | Importing | IT_FIELDS | Call by reference | Type reference (TYPE) | GT_FIELD_TAB_TYPE | Geänderte Felder | 20050407 | ||
5 | Importing | I_EQTYP | Call by reference | Type reference (TYPE) | EQTYP | Equipmenttyp | 20050407 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050407 |
Method EVENT_INHERIT_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CS_EVENT | Call by reference | Type reference (TYPE) | GS_EVENT_TYPE | zu änderndes Ereignis | 20050215 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Es trat ein Fehler auf | 20050211 | |
2 | INHERITANCE_ERROR | Fehler bei der Vererbung | 20050211 | |
3 | WRONG_EQUIPMENT | Falsches übergeordnetes Equipment | 20050211 |
Method EVENT_SET_INHERITANCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CS_EVENT | Call by reference | Type reference (TYPE) | GS_EVENT_TYPE | Daten des Ereignisses | 20050215 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050215 |
Method EZBER_FILL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | R_EZBER | Value transfer | Type reference (TYPE) | EQBER | Technische Informationen, für SAP-interne Nutzung vorgesehen | 20050405 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050405 |
Method FUNC_LOC_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050401 | ||
2 | Importing | I_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20050401 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050401 | |
2 | FUNC_LOC_INACT | Technischer Platz ist inaktiv | 20050401 | |
3 | FUNC_LOC_LVORM | Technischer Platz hat Löschvormerkung | 20050401 | |
4 | FUNC_LOC_NOT_EXIST | Technischer Platz existiert nicht | 20050401 | |
5 | FUNC_LOC_NO_EQUI | Der Einbau von Equipments ist nicht erlaubt | 20050512 |
Method GOODS_MOVEMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_SL_MSG | Call by reference | Type reference (TYPE) | IEQCM_T_MSG_SL_TYPE | Erfolgsprotokoll | 20050608 | ||
2 | Importing | IS_EVENT_NEW | Call by reference | Type reference (TYPE) | GS_EVENT_TYPE | Ereignis neu | 20050608 | ||
3 | Importing | IS_EVENT_OLD | Call by reference | Type reference (TYPE) | GS_EVENT_TYPE | Ereignis alt | 20050608 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050608 | |
2 | GOODS_MOVEMENT_ERROR | Fehler bei Structure Gaps | 20050608 |
Method HISTORY_CHANGE_ALLOWED_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer | 20070215 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20070215 | |
2 | HISTORY_CHANGE_NOT_ALLOWED | historienrelevante Änderung nicht erlaubt | 20070215 |
Method HISTORY_CONSISTENCY_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_CHKCNT | Call by reference | Type reference (TYPE) | IEQCM_S_CHKCNT_TYPE | Anzahl der Fehler | 20050418 | ||
2 | Importing | I_WRITE_MSG | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_FALSE | Soll eine Erfolgsmeldung geschrieben werden? | 20050418 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050404 | |
2 | HISTORY_NOT_CONSISTENT | Die Historie ist nicht Konsistent | 20050404 |
Method HISTORY_EARLIER_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE_START | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050714 | ||
2 | Importing | I_TIME_START | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Uhrzeit gültig ab | 20050714 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | EQUIPMENT_NOT_EXISTS_ON_DATE | Equipment zum Datum nicht vorhanden | 20050714 | |
2 | ERROR | Fehler | 20050714 |
Method HISTORY_FROM_BACKUP Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_COUNTER | Call by reference | Type reference (TYPE) | IEQ_BACKUP | Datensicherung | 20050419 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | BACKUP_ERROR | Fehler im Backup | 20050419 | |
2 | BACKUP_NOT_EXIST | Backup nicht gefunden | 20050419 | |
3 | ERROR | Fehler | 20050419 |
Method HISTORY_FROM_TEMPLATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050315 | ||
2 | Importing | I_EQUNR_TEMPLATE | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer der Vorlage | 20050315 | ||
3 | Importing | I_TIME | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Uhrzeit gültig ab | 20050315 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | DESIRED_HISTORY_NOT_INITIAL | Die Soll-Historie ist nicht initial | 20050315 | |
2 | EQUIPMENT_INACT | Das Equipment ist inaktiv | 20050330 | |
3 | EQUIPMENT_LVORM | Das Equipment hat eine Löschvormerkung | 20050330 | |
4 | EQUIPMENT_NOT_EXISTS_ON_DATE | Vorlageequipment nicht zur Datum vorhanden | 20050315 | |
5 | EQUIPMENT_NOT_FOUND | Vorlageequipment nicht gefunden | 20050315 | |
6 | ERROR | Fehler | 20050315 | |
7 | EVENT_NOT_CONSISTENT | Ein Ereignis ist nicht konsistent | 20050315 | |
8 | HISTORY_INACTIVE | Das Schreiben von Historiensätzen ist nicht aktiv | 20050407 | |
9 | INHERITANCE_ERROR | Fehler bei der Vererbung | 20050315 |
Method HISTORY_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_HISTORY | Call by reference | Type reference (TYPE) | IEQT_EVENT | Arbeitstabelle: Ereignisse | 20050314 | ||
2 | Exporting | E_EVENT_COUNT | Call by reference | Type reference (TYPE) | SYTABIX | Anzahl der Ereignisse | 20050314 | ||
3 | Importing | I_LSTTYP | Call by reference | Type reference (TYPE) | IEQ_LSTTYP | Listentyp | 20050314 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050314 |
Method HISTORY_INHERIT_TO_DATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE | Call by reference | Type reference (TYPE) | DATAB | Datum gültig ab | 20050202 | ||
2 | Importing | I_INCL_DATE | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_FALSE | Vererbung auch für Ende-Datum? (nur bei Unterequipments) | 20050715 | |
3 | Importing | I_TIME | Call by reference | Type reference (TYPE) | TIMBI | Timestamp Equipmenteinsatz | 20050202 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler beim Erstellen der Historie | 20050202 | |
2 | WRONG_EQUIPMENT | Falsches übergeordnetes Equipment | 20050211 |
Method HISTORY_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_EQUI | Call by reference | Type reference (TYPE) | EQUI | Equipment Stammdaten | 20050202 | ||
2 | Exporting | ET_HISTORY | Call by reference | Type reference (TYPE) | GT_HISTORY_TYPE | aktuelle Historie des Equipments | 20050202 | ||
3 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050126 | ||
4 | Importing | I_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipmentnummer | 20050202 | ||
5 | Importing | I_NOTIF | Call by reference | Type reference (TYPE) | ABAP_BOOL | Meldungen zu Ereignissen lesen? | 20050315 | ||
6 | Importing | I_TIME | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Uhrzeit gültig ab | 20050315 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | EQUIPMENT_INACT | Das Equipment ist inaktiv | 20050330 | |
2 | EQUIPMENT_LVORM | Das Equipment hat eine Löschvormerkung | 20050330 | |
3 | EQUIPMENT_NOT_EXISTS_ON_DATE | Equipment zum Datum nicht vorhanden | 20050127 | |
4 | EQUIPMENT_NOT_FOUND | Equipment existiert nicht | 20050127 | |
5 | ERROR | Fehler beim lesen der Historie | 20050126 | |
6 | HISTORY_ERROR | Fehler beim Lesen der Historie | 20050127 | |
7 | HISTORY_INACTIVE | Das Schreiben von Historiensätzen ist nicht aktiv | 20050407 |
Method HISTORY_SUP_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | Datum gültig ab | 20050401 | ||
2 | Importing | I_HEQUI | Call by reference | Type reference (TYPE) | HEQUI | Übergeordnetes Equipment | 20050401 | ||
3 | Importing | I_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20050401 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler beim lesen der Historie | 20050401 | |
2 | FUNC_LOC_NO_EQUI | Der Einbau von Equipments ist nicht erlaubt | 20050512 | |
3 | HISTORY_ERROR | Fehler beim Lesen der Historie | 20050401 | |
4 | OBJECT_INACT | übergeordnetes Objekt ist inaktiv | 20050401 | |
5 | OBJECT_LVORM | übergeordnetes Objekt hat eine Löschvormerkung | 20050401 | |
6 | OBJECT_NOT_EXIST | Übergeordnetes Objekt existiert nixgt | 20050401 | |
7 | OBJECT_NOT_EXIST_ON_DATE | übergeordnetes Objekt zum Datum nicht vorhanden | 20050401 |
Method ILOAN_NUMBER_GET_NEXT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | R_ILOAN | Value transfer | Type reference (TYPE) | ILOAN | Standort und Kontierung zum technischen Objekt | 20050329 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050329 |
Method INHERITANCE_EXECUTE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IT_CHANGE_PERIODS | Call by reference | Type reference (TYPE) | GT_PERIODS_TYPE | Range der zu vererbebdeb Zeitintervalle | 20050224 | ||
2 | Importing | IT_HEQUI_LIST | Call by reference | Type reference (TYPE) | GT_HEQUI_LIST_TYPE | Liste der übergeordneten Equipments | 20050406 | ||
3 | Importing | IT_HISTORY_SUP | Call by reference | Type reference (TYPE) | GT_HISTORY_TYPE | Histore des übergeordneten Objekts | 20050224 | ||
4 | Importing | IT_OBJECT_LIST_REF | Call by reference | Object reference (TYPE REF TO) | GT_OBJECTS_TYPE | Ref. auf Tabelle aller Instanzen in der Vererbung | 20050712 | ||
5 | Importing | I_HEQUI | Call by reference | Type reference (TYPE) | HEQUI | Aufrufendes Equipment | 20050225 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050224 | |
2 | EVENT_NOT_AT_END | Event nicht am Ende der Historie | 20050228 | |
3 | EVENT_NOT_CONSISTENT | Neues Event ist nicht Konsistent | 20050228 | |
4 | EVENT_NOT_EXISTS | Ereignis existiert nicht | 20050228 | |
5 | INHERITANCE_ERROR | Fehler bei der Vererbung | 20050228 | |
6 | SUBEQUIPMENT_INHERITANCE_ERROR | Fehler beim Vererben an ein Unterequipment | 20050322 | |
7 | SUBEQUIPMENT_INIT_ERROR | Fehler beim Instanziieren eines Unterequipments | 20050322 |
Method INHERITANCE_START Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_CHKCNT | Call by reference | Type reference (TYPE) | IEQCM_S_CHKCNT_TYPE | Anzahl Fehler | 20050418 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | EQUIPMENT_NOT_CONSISTENT | Das Equipment ist nicht konsistent | 20050404 | |
2 | ERROR | 20050223 | ||
3 | SUBEQUIPMENT_INHERITANCE_ERROR | Fehler beim Vererben an ein Unterequipment | 20050322 | |
4 | SUBEQUIPMENT_INIT_ERROR | Fehler beim Instanziieren eines Unterequipments | 20050223 |
Method INITIALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_EVENT_COUNT | Call by reference | Type reference (TYPE) | SYTABIX | Index interner Tabellen | 20050316 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler beim Initialisieren | 20050126 | |
2 | SUPERIOR_EQUIPMENT_ERROR | Fehler beim Lesen des übergeordneten Equipments | 20050330 |
Method LOCATION_TEXT_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20050216 | ||
2 | Returning | R_PLTXT | Value transfer | Type reference (TYPE) | PLTXT | Bezeichnung des Technischen Platzes | 20050216 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | TEXT_NOT_FOUND | Keinen Text gefunden | 20050216 |
Method MEASUREMENTS_UPDATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_SL_MSG | Call by reference | Type reference (TYPE) | IEQCM_T_MSG_SL_TYPE | Success Nachrichten | 20050407 | ||
2 | Importing | IT_EQUI_PERIODS | Call by reference | Type reference (TYPE) | IEQCM_T_EQUI_PERIOD_TYPE | Unterequipments & Einbauperioden | 20050420 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050401 | |
2 | MEASUREMENT_OLD_SAVE_ERROR | Fehler beim Sichern der alten Meßwerte | 20050401 |
Method MESSAGES_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_REFRESH | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_ON | Soll Nachrichtentabelle geleert werden? | 20050314 | |
2 | Returning | RT_MSG | Value transfer | Type reference (TYPE) | IEQT_MSG | Hilfstabelle für Nachrichten-/Erfolgsprotokoll | 20050322 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050314 |
Method MESSAGE_ADD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_MSGID | Call by reference | Type reference (TYPE) | SYMSGID | IEQCM_CS_MSGID-IEQ | Nachrichtenklasse | 20050316 | |
2 | Importing | I_MSGNO | Call by reference | Type reference (TYPE) | SYMSGNO | Nachrichtennummer | 20050316 | ||
3 | Importing | I_MSGTYP | Call by reference | Type reference (TYPE) | SYMSGTY | IEQCM_CS_MSGTYP-ERROR | Nachrichtentyp | 20050316 | |
4 | Importing | I_MSGV1 | Call by reference | Type reference (TYPE) | ANY | Nachrichtenvariable 1 | 20050316 | ||
5 | Importing | I_MSGV2 | Call by reference | Type reference (TYPE) | ANY | Nachrichtenvariable 2 | 20050316 | ||
6 | Importing | I_MSGV3 | Call by reference | Type reference (TYPE) | ANY | Nachrichtenvariable 3 | 20050316 | ||
7 | Importing | I_MSGV4 | Call by reference | Type reference (TYPE) | ANY | Nachrichtenvariable 4 | 20050316 | ||
8 | Importing | I_TRACE | Call by reference | Type reference (TYPE) | XFELD | Nachricht für Trace | 20050316 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050316 |
Method STRUCTUR_GAP_HANDLING Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_SL_MSG | Call by reference | Type reference (TYPE) | IEQCM_T_MSG_SL_TYPE | Erfolgsprotokoll | 20050608 | ||
2 | Importing | IS_EVENT_NEW | Call by reference | Type reference (TYPE) | GS_EVENT_TYPE | Ereignis neu | 20050608 | ||
3 | Importing | IS_EVENT_OLD | Call by reference | Type reference (TYPE) | GS_EVENT_TYPE | Ereignis alt | 20050608 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050608 | |
2 | STRUCTUR_GAP_ERROR | Fehler bei Structure Gaps | 20050608 |
Method SUBEQUIPMENTS_FIND Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE_END | Call by reference | Type reference (TYPE) | DATBI | GC_DATE_NOW | Enddatum der Suche | 20050222 | |
2 | Importing | I_DATE_START | Call by reference | Type reference (TYPE) | DATAB | Startdatum der Suche | 20050222 | ||
3 | Importing | I_TIME_END | Call by reference | Type reference (TYPE) | TIMBI | Endzeit der Suche | 20050222 | ||
4 | Importing | I_TIME_START | Call by reference | Type reference (TYPE) | IEQ_TIMAB | Startzeit der Suche | 20050222 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050222 | |
2 | WRONG_DATE | Falsche Datumsangabe | 20050222 |
Method TEST_EVENT_ADD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DATE | Call by reference | Type reference (TYPE) | IEQ_DATAB | SY-DATUM | Datum gültig ab | 20050214 | |
2 | Importing | I_EVENT_TYPE | Call by reference | Type reference (TYPE) | IEQ_EVENT_TYPE | Ereignistyp | 20050324 | ||
3 | Importing | I_FIELDNAME | Call by reference | Type reference (TYPE) | FIELDNAME | zu änderndes Feld | 20050214 | ||
4 | Importing | I_HEQUI | Call by reference | Type reference (TYPE) | HEQUI | Übergeordnetes Equipment | 20050324 | ||
5 | Importing | I_TIME | Call by reference | Type reference (TYPE) | IEQ_TIMAB | SY-UZEIT | Uhrzeit gültig ab | 20050214 | |
6 | Importing | I_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20050324 | ||
7 | Importing | I_VALUE | Call by reference | Type reference (TYPE) | CHAR40 | Feldinhalt | 20050214 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050214 |
Method WORKLIST_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_WL_HEADER | Call by reference | Type reference (TYPE) | IEQT_WL_HEADER | Zwischenstände - Kopfdaten | 20050318 | ||
2 | Exporting | ET_WL_ITEMS | Call by reference | Type reference (TYPE) | IEQCM_T_WL_ITEMS_TYPE | Arbeitstabelle | 20050318 | ||
3 | Exporting | E_EVENT_COUNT | Call by reference | Type reference (TYPE) | SYTABIX | Anzahl der Ereignisse | 20050318 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050318 |
Method WORKLIST_HEADER_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RS_WL_HEADER | Value transfer | Type reference (TYPE) | IEQT_WL_HEADER | Zwischenstände - Kopfdaten | 20050318 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050318 |
Method WORKLIST_READ Signature
Method WORKLIST_READ on class CL_IEQCM_BE_EQUIPMENT has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050321 | |
2 | WORKLIST_NOT_CONSISTENT | Die Zwischensicherung ist nicht konsistent | 20050321 |
Method WORKLIST_UPDATE_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | R_CHANGED | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20050405 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20050406 |
History
Last changed by/on | SAP | 20100310 |
SAP Release Created in | 600 |