SAP ABAP Class CL_ICL_WF_TRIGGER (Workflow: Trigger Data)
Hierarchy
☛
INSURANCE (Software Component) SAP Insurance
⤷
FS-CM (Application Component) Claims Management
⤷
ICL_WORKFLOW (Package) FS-CM: Workflow for Claim and Claim Bundle
⤷
⤷
Properties
| Class | CL_ICL_WF_TRIGGER | |
| Short Description | Workflow: Trigger Data | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | ICL_WORKFLOW | FS-CM: Workflow for Claim and Claim Bundle |
| Created | 20030604 | SAP |
| Last change | 20090218 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class CL_ICL_WF_TRIGGER has no forward declaration.
Interfaces
Class CL_ICL_WF_TRIGGER has no interface implemented.
Friends
Class CL_ICL_WF_TRIGGER has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Instance attribute | Private | Object reference (TYPE REF TO) | IF_EX_ICL_WF_EVT_CONTAINER | Change BAdI Event Container | 20030604 | |||
| 2 | Instance attribute | Private | Object reference (TYPE REF TO) | IF_EX_ICL_WF_CONTAINER | Change BAdI 4.71 Event Container | 20030606 | |||
| 3 | Instance attribute | Private | Type reference (TYPE) | ICL_WF_TRIGGER_TAB | Trigger Data | 20081124 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Call BADI | 20030604 | |
| 2 | Instance method | Private | Method | Call BADI Rel. 4.71 (Regarding Compatibility) | 20030606 | |
| 3 | Instance method | Private | Method | Get Container | 20030604 | |
| 4 | Instance method | Private | Method | Determine Event (Through Release 4.72) | 20040609 | |
| 5 | Instance method | Private | Method | Determine Event (As From Release 4.73) | 20040609 | |
| 6 | Instance method | Private | Method | Set Container Element | 20030604 | |
| 7 | Instance method | Public | Method | Trigger Event | 20030606 | |
| 8 | Instance method | Public | Method | Set Final Object Number | 20030604 | |
| 9 | Instance method | Private | Method | Determine Highest Priority | 20030604 | |
| 10 | Instance method | Public | Method | Set Preliminary Object Number | 20030604 | |
| 11 | Instance method | Public | Method | Delete Trigger Data if not Transferred | 20031117 | |
| 12 | Instance method | Public | Method | Set Trigger Data | 20030604 | |
| 13 | Instance method | Public | Method | Transfer Trigger Data | 20031117 | |
| 14 | Instance method | Private | Method | Determine BRF Expression | 20030604 |
Events
Class CL_ICL_WF_TRIGGER has no event.
Types
Class CL_ICL_WF_TRIGGER has no local type.
Method Signatures
Method BADI_CALL Signature
Method BADI_CALL on class CL_ICL_WF_TRIGGER has no parameter.
Method BADI_CALL on class CL_ICL_WF_TRIGGER has no exception.
Method BADI_CALL_471 Signature
Method BADI_CALL_471 on class CL_ICL_WF_TRIGGER has no parameter.
Method BADI_CALL_471 on class CL_ICL_WF_TRIGGER has no exception.
Method CONTAINER_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_CONT | Value transfer | Type reference (TYPE) | ICL_WF_CONT_TAB | Container | 20030604 | |||
| 2 | IS_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Schadenteilobjekt | 20030604 | |||
| 3 | IV_BRF_FUNC | Call by reference | Type reference (TYPE) | PROGRAMM | Funktionsbaustein BRF-Wertermittlung | 20030610 | |||
| 4 | IV_EVENT | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis | 20030604 |
Method CONTAINER_GET on class CL_ICL_WF_TRIGGER has no exception.
Method DETERMINE_EVENT_472 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_OBJECT_NEW | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Workflow: Fallteilobjekt (Fall, Teilfall ...) | 20040609 | |||
| 2 | EV_EVENT | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis | 20040609 | |||
| 3 | IS_OBJECT_OLD | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Workflow: Fallteilobjekt (Fall, Teilfall ...) | 20040609 | |||
| 4 | IV_EVENT_CLOSED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geschlossen' | 20040609 | |||
| 5 | IV_EVENT_OPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geöffnet' | 20040610 | |||
| 6 | IV_EVENT_REOPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'wieder geöffnet' | 20040610 | |||
| 7 | IV_PRIO_HIGH_NEW | Call by reference | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Neue höchste Priorität | 20040610 | |||
| 8 | IV_PRIO_HIGH_OLD | Call by reference | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Alte höchste Priorität | 20040610 |
Method DETERMINE_EVENT_472 on class CL_ICL_WF_TRIGGER has no exception.
Method DETERMINE_EVENT_473 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Workflow: Fallteilobjekt (Fall, Teilfall ...) | 20040610 | |||
| 2 | EV_EVENT | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis | 20040609 | |||
| 3 | IV_EVENT_CLOSED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geschlossen' | 20040609 | |||
| 4 | IV_EVENT_OPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geöffnet' | 20040609 | |||
| 5 | IV_EVENT_REOPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'wieder geöffnet' | 20040609 | |||
| 6 | IV_PRIO_HIGH | Call by reference | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Höchste Priorität | 20040609 |
Method DETERMINE_EVENT_473 on class CL_ICL_WF_TRIGGER has no exception.
Method ELEMENT_SET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_CONT | Value transfer | Type reference (TYPE) | SWCONTTAB | Container-Tabelle | 20030604 | |||
| 2 | IV_LENGTH | Call by reference | Type reference (TYPE) | BRF_RESULT_LENGTH | Länge | 20030604 | |||
| 3 | IV_PARAM | Call by reference | Type reference (TYPE) | SWO_PARAM | Name | 20030604 | |||
| 4 | IV_TYPE | Call by reference | Type reference (TYPE) | ICL_CMC_TYPE | Typ | 20030604 | |||
| 5 | IV_VALUE | Call by reference | Type reference (TYPE) | SYMSGV | Wert | 20030604 |
Method ELEMENT_SET on class CL_ICL_WF_TRIGGER has no exception.
Method EVENT_TRIGGER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_IN_UPDTASK | Call by reference | Type reference (TYPE) | C | 'X' | In Update-Task | 20030606 |
Method EVENT_TRIGGER on class CL_ICL_WF_TRIGGER has no exception.
Method PERS_NUMBER_SET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IT_ASSIGNMENT | Call by reference | Type reference (TYPE) | TABLE | Nummernzuordnungstabelle | 20030605 | |||
| 2 | IV_ASSIGNMENT_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ der Nummernzuordnungstabelle | 20030605 | |||
| 3 | IV_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der Nummer im Objektschlüssel | 20030605 | |||
| 4 | IV_OBJKEY_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ des Objektschlüssels | 20030604 | |||
| 5 | IV_PERS_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der persistenten Nummer | 20030606 | |||
| 6 | IV_TEMP_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der temporären Nummer | 20030606 |
Method PERS_NUMBER_SET on class CL_ICL_WF_TRIGGER has no exception.
Method PRIO_HIGH_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_PRIO_HIGH | Value transfer | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Höchste Priorität | 20030604 | |||
| 2 | IT_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT_TAB | Schadenteilobjekt | 20030604 |
Method PRIO_HIGH_GET on class CL_ICL_WF_TRIGGER has no exception.
Method TEMP_NUMBER_SET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der Nummer im Objektschlüssel | 20030605 | |||
| 2 | IV_NUMBER_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ der Nummer | 20030605 | |||
| 3 | IV_OBJKEY_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ des Objekschlüssels | 20030604 | |||
| 4 | IV_TEMP_NUMBER | Call by reference | Type reference (TYPE) | ANY | Temporäre Nummer | 20030604 |
Method TEMP_NUMBER_SET on class CL_ICL_WF_TRIGGER has no exception.
Method TRIGGER_REFRESH Signature
Method TRIGGER_REFRESH on class CL_ICL_WF_TRIGGER has no parameter.
Method TRIGGER_REFRESH on class CL_ICL_WF_TRIGGER has no exception.
Method TRIGGER_SET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_OBJECT_NEW | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT_TAB | Workflow: Schadenteilobjekt (Schaden, Teilschaden ...) | 20040609 | |||
| 2 | IT_OBJECT_OLD | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT_TAB | Schadenteilobjekt alt | 20030604 | |||
| 3 | IV_BRF_FUNC | Call by reference | Type reference (TYPE) | PROGRAMM | Funktionsbaustein BRF-Wertermittlung | 20030610 | |||
| 4 | IV_EVENT_CLOSED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geschlossen' | 20030604 | |||
| 5 | IV_EVENT_OPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geöffnet' | 20030604 | |||
| 6 | IV_EVENT_REOPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'wieder geöffnet' | 20030604 |
Method TRIGGER_SET on class CL_ICL_WF_TRIGGER has no exception.
Method TRIGGER_TAKE Signature
Method TRIGGER_TAKE on class CL_ICL_WF_TRIGGER has no parameter.
Method TRIGGER_TAKE on class CL_ICL_WF_TRIGGER has no exception.
Method VALUE_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_LENGTH | Call by reference | Type reference (TYPE) | BRF_RESULT_LENGTH | Feldlänge | 20030604 | |||
| 2 | EV_TYPE | Call by reference | Type reference (TYPE) | ICL_CMC_TYPE | Feldtyp | 20030604 | |||
| 3 | EV_VALUE | Call by reference | Type reference (TYPE) | SYMSGV | Feldwert | 20030604 | |||
| 4 | IS_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Schadenteilobjekt | 20030604 | |||
| 5 | IV_BRF_FUNC | Call by reference | Type reference (TYPE) | PROGRAMM | Funktionsbaustein BRF-Wertermittlung | 20030610 | |||
| 6 | IV_EXPRESSION | Call by reference | Type reference (TYPE) | BRF_EXPRESSION | Ausdruck | 20030604 |
Method VALUE_GET on class CL_ICL_WF_TRIGGER has no exception.
History
| Last changed by/on | SAP | 20090218 |
| SAP Release Created in | 472 |