SAP ABAP Class CL_ICL_WF_TRIGGER (Workflow: Trigger Data)
Hierarchy
☛
INSURANCE (Software Component) SAP Insurance
⤷
FS-CM (Application Component) Claims Management
⤷
ICL_WORKFLOW (Package) FS-CM: Workflow for Claim and Claim Bundle

⤷

⤷

Properties
Class | CL_ICL_WF_TRIGGER | |
Short Description | Workflow: Trigger Data | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | ICL_WORKFLOW | FS-CM: Workflow for Claim and Claim Bundle |
Created | 20030604 | SAP |
Last change | 20090218 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_ICL_WF_TRIGGER has no forward declaration.
Interfaces
Class CL_ICL_WF_TRIGGER has no interface implemented.
Friends
Class CL_ICL_WF_TRIGGER has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_EX_ICL_WF_EVT_CONTAINER | Change BAdI Event Container | 20030604 | ||
2 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_EX_ICL_WF_CONTAINER | Change BAdI 4.71 Event Container | 20030606 | ||
3 | ![]() |
Instance attribute | Private | Type reference (TYPE) | ICL_WF_TRIGGER_TAB | Trigger Data | 20081124 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Call BADI | 20030604 |
2 | ![]() |
Instance method | Private | Method | Call BADI Rel. 4.71 (Regarding Compatibility) | 20030606 |
3 | ![]() |
Instance method | Private | Method | Get Container | 20030604 |
4 | ![]() |
Instance method | Private | Method | Determine Event (Through Release 4.72) | 20040609 |
5 | ![]() |
Instance method | Private | Method | Determine Event (As From Release 4.73) | 20040609 |
6 | ![]() |
Instance method | Private | Method | Set Container Element | 20030604 |
7 | ![]() |
Instance method | Public | Method | Trigger Event | 20030606 |
8 | ![]() |
Instance method | Public | Method | Set Final Object Number | 20030604 |
9 | ![]() |
Instance method | Private | Method | Determine Highest Priority | 20030604 |
10 | ![]() |
Instance method | Public | Method | Set Preliminary Object Number | 20030604 |
11 | ![]() |
Instance method | Public | Method | Delete Trigger Data if not Transferred | 20031117 |
12 | ![]() |
Instance method | Public | Method | Set Trigger Data | 20030604 |
13 | ![]() |
Instance method | Public | Method | Transfer Trigger Data | 20031117 |
14 | ![]() |
Instance method | Private | Method | Determine BRF Expression | 20030604 |
Events
Class CL_ICL_WF_TRIGGER has no event.
Types
Class CL_ICL_WF_TRIGGER has no local type.
Method Signatures
Method BADI_CALL Signature
Method BADI_CALL on class CL_ICL_WF_TRIGGER has no parameter.
Method BADI_CALL on class CL_ICL_WF_TRIGGER has no exception.
Method BADI_CALL_471 Signature
Method BADI_CALL_471 on class CL_ICL_WF_TRIGGER has no parameter.
Method BADI_CALL_471 on class CL_ICL_WF_TRIGGER has no exception.
Method CONTAINER_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_CONT | Value transfer | Type reference (TYPE) | ICL_WF_CONT_TAB | Container | 20030604 | ||
2 | ![]() |
IS_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Schadenteilobjekt | 20030604 | ||
3 | ![]() |
IV_BRF_FUNC | Call by reference | Type reference (TYPE) | PROGRAMM | Funktionsbaustein BRF-Wertermittlung | 20030610 | ||
4 | ![]() |
IV_EVENT | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis | 20030604 |
Method CONTAINER_GET on class CL_ICL_WF_TRIGGER has no exception.
Method DETERMINE_EVENT_472 Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CS_OBJECT_NEW | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Workflow: Fallteilobjekt (Fall, Teilfall ...) | 20040609 | ||
2 | ![]() |
EV_EVENT | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis | 20040609 | ||
3 | ![]() |
IS_OBJECT_OLD | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Workflow: Fallteilobjekt (Fall, Teilfall ...) | 20040609 | ||
4 | ![]() |
IV_EVENT_CLOSED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geschlossen' | 20040609 | ||
5 | ![]() |
IV_EVENT_OPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geöffnet' | 20040610 | ||
6 | ![]() |
IV_EVENT_REOPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'wieder geöffnet' | 20040610 | ||
7 | ![]() |
IV_PRIO_HIGH_NEW | Call by reference | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Neue höchste Priorität | 20040610 | ||
8 | ![]() |
IV_PRIO_HIGH_OLD | Call by reference | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Alte höchste Priorität | 20040610 |
Method DETERMINE_EVENT_472 on class CL_ICL_WF_TRIGGER has no exception.
Method DETERMINE_EVENT_473 Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CS_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Workflow: Fallteilobjekt (Fall, Teilfall ...) | 20040610 | ||
2 | ![]() |
EV_EVENT | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis | 20040609 | ||
3 | ![]() |
IV_EVENT_CLOSED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geschlossen' | 20040609 | ||
4 | ![]() |
IV_EVENT_OPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geöffnet' | 20040609 | ||
5 | ![]() |
IV_EVENT_REOPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'wieder geöffnet' | 20040609 | ||
6 | ![]() |
IV_PRIO_HIGH | Call by reference | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Höchste Priorität | 20040609 |
Method DETERMINE_EVENT_473 on class CL_ICL_WF_TRIGGER has no exception.
Method ELEMENT_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CT_CONT | Value transfer | Type reference (TYPE) | SWCONTTAB | Container-Tabelle | 20030604 | ||
2 | ![]() |
IV_LENGTH | Call by reference | Type reference (TYPE) | BRF_RESULT_LENGTH | Länge | 20030604 | ||
3 | ![]() |
IV_PARAM | Call by reference | Type reference (TYPE) | SWO_PARAM | Name | 20030604 | ||
4 | ![]() |
IV_TYPE | Call by reference | Type reference (TYPE) | ICL_CMC_TYPE | Typ | 20030604 | ||
5 | ![]() |
IV_VALUE | Call by reference | Type reference (TYPE) | SYMSGV | Wert | 20030604 |
Method ELEMENT_SET on class CL_ICL_WF_TRIGGER has no exception.
Method EVENT_TRIGGER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_IN_UPDTASK | Call by reference | Type reference (TYPE) | C | 'X' | In Update-Task | 20030606 |
Method EVENT_TRIGGER on class CL_ICL_WF_TRIGGER has no exception.
Method PERS_NUMBER_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IT_ASSIGNMENT | Call by reference | Type reference (TYPE) | TABLE | Nummernzuordnungstabelle | 20030605 | ||
2 | ![]() |
IV_ASSIGNMENT_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ der Nummernzuordnungstabelle | 20030605 | ||
3 | ![]() |
IV_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der Nummer im Objektschlüssel | 20030605 | ||
4 | ![]() |
IV_OBJKEY_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ des Objektschlüssels | 20030604 | ||
5 | ![]() |
IV_PERS_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der persistenten Nummer | 20030606 | ||
6 | ![]() |
IV_TEMP_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der temporären Nummer | 20030606 |
Method PERS_NUMBER_SET on class CL_ICL_WF_TRIGGER has no exception.
Method PRIO_HIGH_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_PRIO_HIGH | Value transfer | Type reference (TYPE) | ICL_TASK_PRIORITY_WF | Höchste Priorität | 20030604 | ||
2 | ![]() |
IT_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT_TAB | Schadenteilobjekt | 20030604 |
Method PRIO_HIGH_GET on class CL_ICL_WF_TRIGGER has no exception.
Method TEMP_NUMBER_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_NUMBER_NAME | Call by reference | Type reference (TYPE) | NAME_KOMP | Name der Nummer im Objektschlüssel | 20030605 | ||
2 | ![]() |
IV_NUMBER_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ der Nummer | 20030605 | ||
3 | ![]() |
IV_OBJKEY_TYPE | Call by reference | Type reference (TYPE) | KOMP_TYPE | Typ des Objekschlüssels | 20030604 | ||
4 | ![]() |
IV_TEMP_NUMBER | Call by reference | Type reference (TYPE) | ANY | Temporäre Nummer | 20030604 |
Method TEMP_NUMBER_SET on class CL_ICL_WF_TRIGGER has no exception.
Method TRIGGER_REFRESH Signature
Method TRIGGER_REFRESH on class CL_ICL_WF_TRIGGER has no parameter.
Method TRIGGER_REFRESH on class CL_ICL_WF_TRIGGER has no exception.
Method TRIGGER_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CT_OBJECT_NEW | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT_TAB | Workflow: Schadenteilobjekt (Schaden, Teilschaden ...) | 20040609 | ||
2 | ![]() |
IT_OBJECT_OLD | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT_TAB | Schadenteilobjekt alt | 20030604 | ||
3 | ![]() |
IV_BRF_FUNC | Call by reference | Type reference (TYPE) | PROGRAMM | Funktionsbaustein BRF-Wertermittlung | 20030610 | ||
4 | ![]() |
IV_EVENT_CLOSED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geschlossen' | 20030604 | ||
5 | ![]() |
IV_EVENT_OPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'geöffnet' | 20030604 | ||
6 | ![]() |
IV_EVENT_REOPENED | Call by reference | Type reference (TYPE) | SWO_EVENT | Ereignis 'wieder geöffnet' | 20030604 |
Method TRIGGER_SET on class CL_ICL_WF_TRIGGER has no exception.
Method TRIGGER_TAKE Signature
Method TRIGGER_TAKE on class CL_ICL_WF_TRIGGER has no parameter.
Method TRIGGER_TAKE on class CL_ICL_WF_TRIGGER has no exception.
Method VALUE_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_LENGTH | Call by reference | Type reference (TYPE) | BRF_RESULT_LENGTH | Feldlänge | 20030604 | ||
2 | ![]() |
EV_TYPE | Call by reference | Type reference (TYPE) | ICL_CMC_TYPE | Feldtyp | 20030604 | ||
3 | ![]() |
EV_VALUE | Call by reference | Type reference (TYPE) | SYMSGV | Feldwert | 20030604 | ||
4 | ![]() |
IS_OBJECT | Call by reference | Type reference (TYPE) | ICL_WF_OBJECT | Schadenteilobjekt | 20030604 | ||
5 | ![]() |
IV_BRF_FUNC | Call by reference | Type reference (TYPE) | PROGRAMM | Funktionsbaustein BRF-Wertermittlung | 20030610 | ||
6 | ![]() |
IV_EXPRESSION | Call by reference | Type reference (TYPE) | BRF_EXPRESSION | Ausdruck | 20030604 |
Method VALUE_GET on class CL_ICL_WF_TRIGGER has no exception.
History
Last changed by/on | SAP | 20090218 |
SAP Release Created in | 472 |