SAP ABAP Class CL_HRTMC_PD_OBJECT_CP (PD Object Class for Central Person)
Hierarchy
SAP_BS_FND (Software Component) SAP Business Suite Foundation
   CA-EPT-TM (Application Component) Talent Management
     HCM_TMC (Package) HCM: Talent Management Core
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CL_HRTMC_PD_OBJECT PD Object Class of Talent Management 20080407
Properties
Class CL_HRTMC_PD_OBJECT_CP  
Short Description PD Object Class for Central Person    
Super Class CL_HRTMC_PD_OBJECT PD Object Class of Talent Management 
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package HCM_TMC   HCM: Talent Management Core 
Created 20080407   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class CL_HRTMC_PD_OBJECT_CP has no forward declaration.
Interfaces
Class CL_HRTMC_PD_OBJECT_CP has no interface implemented.
Friends
Class CL_HRTMC_PD_OBJECT_CP has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 MC_CONFIRMED Constant Protected Type reference (TYPE) HRTMC_P_STATUS 'CONFIRMED' Status of Performance or Potential Record 20080508
2 MC_MSG_CLASS Constant Private Type reference (TYPE) STRING 'HRTMC_BASIS' 20080602
3 MC_PERFORMANCE Constant Protected Type reference (TYPE) INFTY '7409' Infotype 20080508
4 MC_PMP_PERIOD Constant Private Type reference (TYPE) HRTMC_PP_TARGET_TYPE 'PERFORMNCE' Type of Key Date 20080801
5 MC_POTENTIAL Constant Protected Type reference (TYPE) INFTY '7408' Infotype 20080508
6 MC_POT_PERIOD Constant Private Type reference (TYPE) HRTMC_PP_TARGET_TYPE 'POTENTIAL' Type of Key Date 20080801
7 MV_ASSIGN_CHECK_ENABLE Instance attribute Private Type reference (TYPE) BOOLE_D 'X' Data Element for Domain BOOLE: TRUE (='X') and FALSE (=' ') 20080602
8 MV_MODIFY Instance attribute Private Type reference (TYPE) BOOLE_D 'X' Data Element for Domain BOOLE: TRUE (='X') and FALSE (=' ') 20080602
Methods
# Method Level Visibility Method type Description Created on
1 DELETE_INFTY_PERFORMANCE_RM Instance method Public Method Deletes Infotype Record Performance + LOOK_AHEAD 20080515
2 DELETE_INFTY_POTENTIAL_RM Instance method Public Method Deletes Infotype Record Potential 20080515
3 DELIMIT_ASSIGN Instance method Public Method 20080602
4 READ_INFTY_PERFORMANCE Instance method Public Method Reads the Valid Infotype Records for All Periods 20080515
5 READ_INFTY_PERFORMANCE_ALL Instance method Public Method Reads the Valid Infotype Records for All Periods 20080801
6 READ_INFTY_PERFORMANCE_RM Instance method Public Method Reads Current Infotype Record Performance 20080515
7 READ_INFTY_POTENTIAL Instance method Public Method Reads the Valid Infotype Records for All Periods 20080515
8 READ_INFTY_POTENTIAL_ALL Instance method Public Method Reads the Valid Infotype Records for All Periods 20080801
9 READ_INFTY_POTENTIAL_RM Instance method Public Method Reads Current Infotype Record Potential 20080515
Events
Class CL_HRTMC_PD_OBJECT_CP has no event.
Types
Class CL_HRTMC_PD_OBJECT_CP has no local type.
Method Signatures

Method DELETE_INFTY_PERFORMANCE_RM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
2 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080515
3 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
4 Importing IV_REVIEW_MEETING_ID Call by reference Type reference (TYPE) HROBJID Objekt-Id 20080515
5 Importing IV_UPDATE_MODE Call by reference Type reference (TYPE) HRBAS_UPDATE_MODE Welche Bucherfunktionen sollen abgeschaltet/aktiviert sein? 20080515

Method DELETE_INFTY_PERFORMANCE_RM on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method DELETE_INFTY_POTENTIAL_RM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
2 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080515
3 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
4 Importing IV_REVIEW_MEETING_ID Call by reference Type reference (TYPE) HROBJID Objekt-Id 20080515
5 Importing IV_UPDATE_MODE Call by reference Type reference (TYPE) HRBAS_UPDATE_MODE Welche Bucherfunktionen sollen abgeschaltet/aktiviert sein? 20080515

Method DELETE_INFTY_POTENTIAL_RM on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method DELIMIT_ASSIGN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_RELATION Call by reference Type reference (TYPE) P1001 Infotyp 1001: Verknüpfungen 20080602
2 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080602
3 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080602
4 Importing IS_UPDATE_MODE Call by reference Type reference (TYPE) HRBAS_UPDATE_MODE Welche Bucherfunktionen sollen abgeschaltet/aktiviert sein? 20080602
5 Importing IV_NEW_ADATA Call by reference Type reference (TYPE) ADATA Zusatzdaten Verknüpfung 20080602
6 Importing IV_NEW_BEGDA Call by reference Type reference (TYPE) BEGDA Gültigkeitsbeginn 20110216
7 Importing IV_NEW_ENDDA Call by reference Type reference (TYPE) ENDDATUM Endedatum 20080602
8 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Deaktivierung der Berechtigungsprüfung 20080602
9 Importing IV_OLD_KEY Call by reference Type reference (TYPE) ANY 20080602

Method DELIMIT_ASSIGN on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method READ_INFTY_PERFORMANCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PERFORMANCE Call by reference Type reference (TYPE) HRTMC_T_PERFORMANCE Performance 20080515
2 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
3 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080515
4 Importing IV_BEGDA Call by reference Type reference (TYPE) SY-DATUM SY-DATUM Aktuelles Datum des Applikationsservers 20080515
5 Importing IV_ENDDA Call by reference Type reference (TYPE) SY-DATUM SY-DATUM Aktuelles Datum des Applikationsservers 20080515
6 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
7 Importing IV_PERIOD_GROUP Call by reference Type reference (TYPE) HRTMC_PP_GROUP Gruppe von Betrachtungszeiträumen 20090713

Method READ_INFTY_PERFORMANCE on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method READ_INFTY_PERFORMANCE_ALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PERFORMANCE Call by reference Type reference (TYPE) HRTMC_T_PERFORMANCE Performance 20080801
2 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080801
3 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080801
4 Importing IV_KEY_DATE Call by reference Type reference (TYPE) SY-DATUM SY-DATUM Aktuelles Datum des Applikationsservers 20080801
5 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080801
6 Importing IV_PERIOD_GROUP Call by reference Type reference (TYPE) HRTMC_PP_GROUP Gruppe von Betrachtungszeiträumen 20090713

Method READ_INFTY_PERFORMANCE_ALL on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method READ_INFTY_PERFORMANCE_RM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_INITIAL_PERFORMANCE Call by reference Type reference (TYPE) HRTMC_S_PERFORMANCE Initiale Performance 20091210
2 Exporting ES_PERFORMANCE Call by reference Type reference (TYPE) HRTMC_S_PERFORMANCE Performance 20080515
3 Exporting ET_PERFORMANCE_TAB Call by reference Type reference (TYPE) HRTMC_T_P7409_EXP Performance 20101108
4 Exporting EV_INVALID_INITIAL_ASSESSMENT Call by reference Type reference (TYPE) BOOLE_D Kein gültiger Wert vor aktuellem RM 20091006
5 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D 20080515
6 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080515
7 Importing IV_KEY_DATE Call by reference Type reference (TYPE) DATUM SY-DATUM Datum 20080801
8 Importing IV_MAX_SCALE_VALUE Call by reference Type reference (TYPE) HRTMC_PERFORMANCE Maximaler Skalenwert 20091006
9 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
10 Importing IV_PERIOD_GROUP Call by reference Type reference (TYPE) HRTMC_PP_GROUP Gruppe von Betrachtungszeiträumen 20090713
11 Importing IV_REVIEW_MEETING_ID Call by reference Type reference (TYPE) HROBJID Review Meeting ID 20080515

Method READ_INFTY_PERFORMANCE_RM on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method READ_INFTY_POTENTIAL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_POTENTIAL Call by reference Type reference (TYPE) HRTMC_T_POTENTIAL Potential 20080515
2 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
3 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080515
4 Importing IV_BEGDA Call by reference Type reference (TYPE) SY-DATUM SY-DATUM Aktuelles Datum des Applikationsservers 20080515
5 Importing IV_ENDDA Call by reference Type reference (TYPE) SY-DATUM SY-DATUM Aktuelles Datum des Applikationsservers 20080515
6 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
7 Importing IV_PERIOD_GROUP Call by reference Type reference (TYPE) HRTMC_PP_GROUP Gruppe von Betrachtungszeiträumen 20090713

Method READ_INFTY_POTENTIAL on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method READ_INFTY_POTENTIAL_ALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_POTENTIAL Call by reference Type reference (TYPE) HRTMC_T_POTENTIAL Potential 20080801
2 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080801
3 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080801
4 Importing IV_KEY_DATE Call by reference Type reference (TYPE) SY-DATUM SY-DATUM Aktuelles Datum des Applikationsservers 20080801
5 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080801
6 Importing IV_PERIOD_GROUP Call by reference Type reference (TYPE) HRTMC_PP_GROUP Gruppe von Betrachtungszeiträumen 20090713

Method READ_INFTY_POTENTIAL_ALL on class CL_HRTMC_PD_OBJECT_CP has no exception.

Method READ_INFTY_POTENTIAL_RM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_INITIAL_POTENTIAL Call by reference Type reference (TYPE) HRTMC_S_POTENTIAL Initiales Potenzial 20091210
2 Exporting ES_POTENTIAL Call by reference Type reference (TYPE) HRTMC_S_POTENTIAL Potenzial 20080515
3 Exporting ET_POTENTIAL_TAB Call by reference Type reference (TYPE) HRTMC_T_P7408_EXP Potenzial 20101108
4 Exporting EV_INVALID_INITIAL_ASSESSMENT Call by reference Type reference (TYPE) BOOLE_D Kein gültiger Wert vor aktuellem RM 20091006
5 Exporting EV_IS_OK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
6 Importing IO_MESSAGE_HANDLER Call by reference Object reference (TYPE REF TO) IF_HRBAS_MESSAGE_HANDLER HR-PD-Infotypen: Meldungen 20080515
7 Importing IV_KEY_DATE Call by reference Type reference (TYPE) DATUM SY-DATUM Datum 20080801
8 Importing IV_MAX_SCALE_VALUE Call by reference Type reference (TYPE) HRTMC_POTENTIAL Maximaler Skalenwert 20091006
9 Importing IV_NO_AUTH_CHECK Call by reference Type reference (TYPE) BOOLE_D Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') 20080515
10 Importing IV_PERIOD_GROUP Call by reference Type reference (TYPE) HRTMC_PP_GROUP Gruppe von Betrachtungszeiträumen 20090713
11 Importing IV_REVIEW_MEETING_ID Call by reference Type reference (TYPE) HROBJID Objekt-Id 20080515

Method READ_INFTY_POTENTIAL_RM on class CL_HRTMC_PD_OBJECT_CP has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in 701