SAP ABAP Class CL_GUI_ECATT_SYSTEM_EDITOR (User Interface: System Data Container)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-TWB-TST-ECA (Application Component) eCATT Extended Computer Aided Test Tool
     SECATT_GUI (Package) eCATT GUI Objects
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CL_GUI_ECATT_EDITOR eCATT: Superclass for all Editors 20010612
Properties
Class CL_GUI_ECATT_SYSTEM_EDITOR  
Short Description User Interface: System Data Container    
Super Class CL_GUI_ECATT_EDITOR eCATT: Superclass for all Editors 
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status P  SAP Standard Production Program 
Category 0   
Package SECATT_GUI   eCATT GUI Objects 
Created 20000620   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class CL_GUI_ECATT_SYSTEM_EDITOR has no forward declaration.
Interfaces
Class CL_GUI_ECATT_SYSTEM_EDITOR has no interface implemented.
Friends
Class CL_GUI_ECATT_SYSTEM_EDITOR has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 CC_SYSTEMS Static Attribute Private Object reference (TYPE REF TO) CL_GUI_CUSTOM_CONTAINER System Data Container 20010201
2 TOC Static Attribute Private Object reference (TYPE REF TO) CL_GUI_TEST_OPERATION_CENTER Test Operation Center (Initial Screen eCATT) 20020814
3 UI_SYSTEMS Static Attribute Private Object reference (TYPE REF TO) CL_GUI_ECATT_SYSTEMS System Data Container: System Data 20010305
Methods
# Method Level Visibility Method type Description Created on
1 CONSTRUCTOR Instance method Public Constructor Constructor 20010201
2 CREATE_UI_SYSTEMS Instance method Private Method Generate UI_SYSTEMS 20010612
3 GET_UI_SYSTEMS Instance method Public Method Get Systems from Editor and Send to Middleware 20010731
4 ON_MAINTAIN_MODE_CHANGED Instance method Private Event handling method Processing Mode of System Data Container Changed 20010612
5 ON_SYSTEM_WHEREUSED Instance method Private Event handling method Where-Used List for Target System 20030602
6 ON_UI_SYSTEM_EDIT_DEST Instance method Private Event handling method Edit Destination 20030806
7 SELECT_TESTSYSTEM_F4 Static method Public Method Select Test System Using F4 Help 20011120
8 SET_READONLY_MODE Instance method Public Method Set Display Mode, Read-Only/Edit Mode 20010201
9 SET_UI_SYSTEMS Instance method Public Method Set Systems from Middleware in Editor 20010731
Events
Class CL_GUI_ECATT_SYSTEM_EDITOR has no event.
Types
Class CL_GUI_ECATT_SYSTEM_EDITOR has no local type.
Method Signatures

Method CONSTRUCTOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_ECATT_OBJECT Call by reference Object reference (TYPE REF TO) CL_APL_ECATT_OBJECT Basisklasse für eCATT Objekte. 20010201
2 Importing IM_IF_TOC Call by reference Object reference (TYPE REF TO) IF_GUI_TEST_OPERATION_CENTER Interface für eCATT TOC 20020814
# Exception Resumable Description Created on
1 CX_ECATT_GUI eCatt-Ausnahmen GUI 20010201

Method CREATE_UI_SYSTEMS Signature

Method CREATE_UI_SYSTEMS on class CL_GUI_ECATT_SYSTEM_EDITOR has no parameter.
# Exception Resumable Description Created on
1 CX_ECATT_GUI eCatt-Ausnahmen GUI 20010612

Method GET_UI_SYSTEMS Signature

Method GET_UI_SYSTEMS on class CL_GUI_ECATT_SYSTEM_EDITOR has no parameter.
Method GET_UI_SYSTEMS on class CL_GUI_ECATT_SYSTEM_EDITOR has no exception.

Method ON_MAINTAIN_MODE_CHANGED Signature

Method ON_MAINTAIN_MODE_CHANGED on class CL_GUI_ECATT_SYSTEM_EDITOR has no parameter.
Method ON_MAINTAIN_MODE_CHANGED on class CL_GUI_ECATT_SYSTEM_EDITOR has no exception.

Method ON_SYSTEM_WHEREUSED Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing TESTSYSTEM Call by reference Attribute reference (LIKE) 20030602

Method ON_SYSTEM_WHEREUSED on class CL_GUI_ECATT_SYSTEM_EDITOR has no exception.

Method ON_UI_SYSTEM_EDIT_DEST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing EX_DESTINATION Call by reference Attribute reference (LIKE) 20030806
2 Importing EX_RFCTYPE Call by reference Attribute reference (LIKE) 20030806

Method ON_UI_SYSTEM_EDIT_DEST on class CL_GUI_ECATT_SYSTEM_EDITOR has no exception.

Method SELECT_TESTSYSTEM_F4 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ANSWER Value transfer Type reference (TYPE) ETONOFF 'T' - Übernehmen, 'A' - Abbrechen 20030415
2 Exporting EX_INSTANCE Value transfer Type reference (TYPE) ETSYS_INST Beschreibung einer System-Instanz 20011205
3 Exporting EX_RFCDEST Value transfer Type reference (TYPE) RFCDEST RFC-Destination 20011205
4 Exporting EX_SYSTEMDATA Value transfer Type reference (TYPE) ETSD_NAME Systemdatencontainer 20011205
5 Exporting EX_TESTSYSTEM Value transfer Type reference (TYPE) ETCMP_CMP Ausgewähltes Testsystem 20011205
6 Importing IM_DISPLAY_ONLY Call by reference Type reference (TYPE) ETONOFF SPACE eCATT Schalter Ein/Aus 20050217
7 Importing IM_DYNNR Call by reference Type reference (TYPE) SYDYNNR SPACE ABAP-Programm, Nummer des aktuellen Dynpros 20011120
8 Importing IM_OBJECT_MODE Call by reference Type reference (TYPE) ETOBJ_MODE SPACE Objektbearbeitungsmodus 20030415
9 Importing IM_PROGNAME Call by reference Type reference (TYPE) PROGNAME SPACE ABAP-Programmname 20011120
10 Importing IM_SD_DYNFNAME Call by reference Type reference (TYPE) DYNFNAM SPACE Dynprofeldname des Systemdatencontainers 20011120
11 Importing IM_SD_NAME Call by reference Type reference (TYPE) ETSD_NAME SPACE Systemdatencontainer 20011120
12 Importing IM_TS_FIELDNAME Call by reference Type reference (TYPE) FIELDNAME Feldname des Testsystems 20011120
13 Importing IM_TS_TABNAME Call by reference Type reference (TYPE) TABNAME Tabellenname des Testsystems 20011120

Method SELECT_TESTSYSTEM_F4 on class CL_GUI_ECATT_SYSTEM_EDITOR has no exception.

Method SET_READONLY_MODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_READONLY_MODE Call by reference Type reference (TYPE) I 1 - nicht eingabebereit, 0 - eingabebereit 20010201

Method SET_READONLY_MODE on class CL_GUI_ECATT_SYSTEM_EDITOR has no exception.

Method SET_UI_SYSTEMS Signature

Method SET_UI_SYSTEMS on class CL_GUI_ECATT_SYSTEM_EDITOR has no parameter.
Method SET_UI_SYSTEMS on class CL_GUI_ECATT_SYSTEM_EDITOR has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in 610