SAP ABAP Class CL_GUI_ECATT_EXECUTION_DATA (User Interface: Data Editor for Object Execution)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷ BC-TWB-TST-ECA (Application Component) eCATT Extended Computer Aided Test Tool
⤷ SECATT_GUI (Package) eCATT GUI Objects
⤷ BC-TWB-TST-ECA (Application Component) eCATT Extended Computer Aided Test Tool
⤷ SECATT_GUI (Package) eCATT GUI Objects
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_GUI_ECATT_DATA_EDITOR | User Interface: Test Data Container | 20020618 |
Properties
Class | CL_GUI_ECATT_EXECUTION_DATA | |
Short Description | User Interface: Data Editor for Object Execution | |
Super Class | CL_GUI_ECATT_DATA_EDITOR | User Interface: Test Data Container |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | P | SAP Standard Production Program |
Category | 0 | |
Package | SECATT_GUI | eCATT GUI Objects |
Created | 20020618 | SAP |
Last change | 20130531 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_GUI_ECATT_EXECUTION_DATA has no forward declaration.
Interfaces
Class CL_GUI_ECATT_EXECUTION_DATA has no interface implemented.
Friends
Class CL_GUI_ECATT_EXECUTION_DATA has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | CC_VAR_MODE | Instance attribute | Protected | Object reference (TYPE REF TO) | CL_GUI_CUSTOM_CONTAINER | Mode: Container for Custom Controls in Screen Area | 20031218 | ||
2 | TC_VAR_EXT_MODE | Instance attribute | Public | Type reference (TYPE) | ETVAR_EXT_MODE | Mode Usage of External Variants for Test Configuration | 20040106 | ||
3 | UI_VAR_MODE | Instance attribute | Public | Object reference (TYPE REF TO) | CL_GUI_ECATT_CONFIG_OBJECTS | Editor for Variant Mode | 20031218 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CONSTRUCTOR | Instance method | Public | Constructor | Constructor | 20020618 |
2 | CREATE_UI_VAR_MODE | Instance method | Public | Method | Generate Editor for Variant Mode | 20031218 |
3 | GET_UI_VAR_MODE | Instance method | Public | Method | Get Variant Mode from Editor | 20031218 |
4 | ON_TC_VAR_MODE_SELECTED | Instance method | Protected | Event handling method | Variant Mode for Test Configuration Selected | 20040106 |
5 | ON_VAR_REF_TD_PICKED | Instance method | Private | Event handling method | Reference to Test Data Container in Variant Selected | 20040406 |
6 | SET_UI_VAR_MODE | Instance method | Public | Method | Pass Variant Mode to Editor | 20031218 |
Events
Class CL_GUI_ECATT_EXECUTION_DATA has no event.
Types
Class CL_GUI_ECATT_EXECUTION_DATA has no local type.
Method Signatures
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_ECATT_OBJECT | Call by reference | Object reference (TYPE REF TO) | CL_APL_ECATT_OBJECT | Basisklasse für eCATT Objekte. | 20020618 | ||
2 | Importing | IM_TOC | Call by reference | Object reference (TYPE REF TO) | CL_GUI_TEST_OPERATION_CENTER | Test Operation Center (Einstieg eCATT) | 20020618 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_ECATT_GUI | eCatt-Ausnahmen GUI | 20020618 |
Method CREATE_UI_VAR_MODE Signature
Method CREATE_UI_VAR_MODE on class CL_GUI_ECATT_EXECUTION_DATA has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_ECATT_GUI | eCatt-Ausnahmen GUI | 20031219 |
Method GET_UI_VAR_MODE Signature
Method GET_UI_VAR_MODE on class CL_GUI_ECATT_EXECUTION_DATA has no parameter.
Method GET_UI_VAR_MODE on class CL_GUI_ECATT_EXECUTION_DATA has no exception.
Method ON_TC_VAR_MODE_SELECTED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | OBJECT | Call by reference | Attribute reference (LIKE) | 20040406 | ||||
2 | Importing | USER_SELECTION | Value transfer | Attribute reference (LIKE) | 20040106 |
Method ON_TC_VAR_MODE_SELECTED on class CL_GUI_ECATT_EXECUTION_DATA has no exception.
Method ON_VAR_REF_TD_PICKED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | EX_SYNTAX | Call by reference | Attribute reference (LIKE) | 20040406 | ||||
2 | Importing | EX_TC_PARAM | Call by reference | Attribute reference (LIKE) | 20040406 | ||||
3 | Importing | EX_TC_VAR | Call by reference | Attribute reference (LIKE) | 20040406 | ||||
4 | Importing | EX_TD_NAME | Call by reference | Attribute reference (LIKE) | 20040406 | ||||
5 | Importing | EX_TD_PARAM | Call by reference | Attribute reference (LIKE) | 20040406 | ||||
6 | Importing | EX_TD_VAR | Call by reference | Attribute reference (LIKE) | 20040406 |
Method ON_VAR_REF_TD_PICKED on class CL_GUI_ECATT_EXECUTION_DATA has no exception.
Method SET_UI_VAR_MODE Signature
Method SET_UI_VAR_MODE on class CL_GUI_ECATT_EXECUTION_DATA has no parameter.
Method SET_UI_VAR_MODE on class CL_GUI_ECATT_EXECUTION_DATA has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 630 |