SAP ABAP Class CL_GFW (GFW: Graphical Framework return values/messages)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-FES-GRA (Application Component) Graphic
⤷
SGRB (Package) ABAP Graphic Proxies
⤷
⤷
Properties
| Class | CL_GFW | |
| Short Description | GFW: Graphical Framework return values/messages | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | SGRB | ABAP Graphic Proxies |
| Created | 19980424 | SAP |
| Last change | 19990125 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_GFW has no interface implemented.
Friends
Class CL_GFW has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Public | Type reference (TYPE) | CHAR25 | 'GFW_ITS_RFC_DEST' | default for ITS_RFC_DEST | 19991217 | ||
| 2 | Constant | Public | Type reference (TYPE) | SYMSGNO | '801' | Error (unspecified) | 19980424 | ||
| 3 | Constant | Public | Type reference (TYPE) | SYMSGNO | '802' | Object cannot be created | 19980424 | ||
| 4 | Constant | Public | Type reference (TYPE) | SYMSGNO | '601' | Unspecified error in Customizing | 19980424 | ||
| 5 | Constant | Public | Type reference (TYPE) | SYMSGNO | '611' | Values from a different class cannot be copied | 19990809 | ||
| 6 | Constant | Public | Type reference (TYPE) | SYMSGNO | '608' | No administrator | 19980625 | ||
| 7 | Constant | Public | Type reference (TYPE) | SYMSGNO | '609' | Input value out of range | 19980731 | ||
| 8 | Constant | Public | Type reference (TYPE) | SYMSGNO | '610' | Customizing changes cannot be entered in transport request | 19990330 | ||
| 9 | Constant | Public | Type reference (TYPE) | SYMSGNO | '612' | Transport request dialog canceled by user | 19991207 | ||
| 10 | Constant | Public | Type reference (TYPE) | SYMSGNO | '607' | Unknown attribute | 19980625 | ||
| 11 | Constant | Public | Type reference (TYPE) | SYMSGNO | '751' | DDIC structure cannot be analyzed | 19980702 | ||
| 12 | Constant | Public | Type reference (TYPE) | SYMSGNO | '757' | Create class failed | 19991223 | ||
| 13 | Constant | Public | Type reference (TYPE) | SYMSGNO | '758' | Create source for class failed | 19991223 | ||
| 14 | Constant | Public | Type reference (TYPE) | SYMSGNO | '753' | DDIC element name is too long | 19990108 | ||
| 15 | Constant | Public | Type reference (TYPE) | SYMSGNO | '756' | Class could not be deleted | 19991223 | ||
| 16 | Constant | Public | Type reference (TYPE) | SYMSGNO | '755' | Class already exists | 19991223 | ||
| 17 | Constant | Public | Type reference (TYPE) | SYMSGNO | '759' | Line is too long | 19991227 | ||
| 18 | Constant | Public | Type reference (TYPE) | SYMSGNO | '754' | Template could not be read | 19991222 | ||
| 19 | Constant | Public | Type reference (TYPE) | SYMSGNO | '750' | File could not be written | 19980625 | ||
| 20 | Constant | Public | Type reference (TYPE) | SYMSGNO | '752' | Input parameter incorrect | 19980703 | ||
| 21 | Constant | Public | Type reference (TYPE) | SYMSGNO | '004' | No authorization for service | 19980424 | ||
| 22 | Constant | Public | Type reference (TYPE) | SYMSGNO | '003' | Attribute already exists | 19980424 | ||
| 23 | Constant | Public | Type reference (TYPE) | SYMSGNO | '008' | Double key | 19980424 | ||
| 24 | Constant | Public | Type reference (TYPE) | SYMSGNO | '005' | Master already exists | 19980424 | ||
| 25 | Constant | Public | Type reference (TYPE) | SYMSGNO | '011' | The data records flagged as deleted could not be removed | 19980424 | ||
| 26 | Constant | Public | Type reference (TYPE) | SYMSGNO | '006' | Method empty (not supported) | 19980424 | ||
| 27 | Constant | Public | Type reference (TYPE) | SYMSGNO | '002' | GP handle initial | 19980424 | ||
| 28 | Constant | Public | Type reference (TYPE) | SYMSGNO | '014' | Operation on an internal table failed | 19980508 | ||
| 29 | Constant | Public | Type reference (TYPE) | SYMSGNO | '015' | Internal DC error: Modes table inconsistent with data table | 19980512 | ||
| 30 | Constant | Public | Type reference (TYPE) | SYMSGNO | '010' | Data record not found | 19980424 | ||
| 31 | Constant | Public | Type reference (TYPE) | SYMSGNO | '009' | Key value missing | 19980424 | ||
| 32 | Constant | Public | Type reference (TYPE) | SYMSGNO | '016' | ein 2. GP versucht, Daten zu ändern | 19990705 | ||
| 33 | Constant | Public | Type reference (TYPE) | SYMSGNO | '001' | Unknown attribute | 19980424 | ||
| 34 | Constant | Public | Type reference (TYPE) | SYMSGNO | '012' | Incorrect wizard version | 19980507 | ||
| 35 | Constant | Public | Type reference (TYPE) | SYMSGNO | '206' | Implementation open | 19980424 | ||
| 36 | Constant | Public | Type reference (TYPE) | SYMSGNO | '227' | No connection to CFW | 19980525 | ||
| 37 | Constant | Public | Type reference (TYPE) | SYMSGNO | '229' | Control Framework error | 19980526 | ||
| 38 | Constant | Public | Type reference (TYPE) | SYMSGNO | '234' | Double bundle variant key | 19980623 | ||
| 39 | Constant | Public | Type reference (TYPE) | SYMSGNO | '239' | bundle not added before | 19990812 | ||
| 40 | Constant | Public | Type reference (TYPE) | SYMSGNO | '233' | Bundle type is not allowed | 19980623 | ||
| 41 | Constant | Public | Type reference (TYPE) | SYMSGNO | '222' | Customizing parameter could not be set | 19980424 | ||
| 42 | Constant | Public | Type reference (TYPE) | SYMSGNO | '205' | No connection to data container | 19980424 | ||
| 43 | Constant | Public | Type reference (TYPE) | SYMSGNO | '230' | Missing data container attribute name | 19980612 | ||
| 44 | Constant | Public | Type reference (TYPE) | SYMSGNO | '231' | Data container cannot be changed 'on the fly' | 19980617 | ||
| 45 | Constant | Public | Type reference (TYPE) | SYMSGNO | '219' | Event could not be deregistered | 19980424 | ||
| 46 | Constant | Public | Type reference (TYPE) | SYMSGNO | '237' | Method empty (not supported) | 19981124 | ||
| 47 | Constant | Public | Type reference (TYPE) | SYMSGNO | '210' | Unknown Event | 19980424 | ||
| 48 | Constant | Public | Type reference (TYPE) | SYMSGNO | '241' | exporting picture failed | 20000403 | ||
| 49 | Constant | Public | Type reference (TYPE) | SYMSGNO | '204' | Function module error | 19980424 | ||
| 50 | Constant | Public | Type reference (TYPE) | SYMSGNO | '208' | Unknown GUI object ID | 19980424 | ||
| 51 | Constant | Public | Type reference (TYPE) | SYMSGNO | '235' | Method initialization: Placing parameters missing | 19981009 | ||
| 52 | Constant | Public | Type reference (TYPE) | SYMSGNO | '240' | no connection to graphic RFC | 19990921 | ||
| 53 | Constant | Public | Type reference (TYPE) | SYMSGNO | '217' | MUX missing | 19980424 | ||
| 54 | Constant | Public | Type reference (TYPE) | SYMSGNO | '228' | Function not available; no control | 19980525 | ||
| 55 | Constant | Public | Type reference (TYPE) | SYMSGNO | '202' | No data available | 19980424 | ||
| 56 | Constant | Public | Type reference (TYPE) | SYMSGNO | '242' | Proxy cannnot be main proxy | 20000920 | ||
| 57 | Constant | Public | Type reference (TYPE) | SYMSGNO | '243' | Proxy cannot be sub proxy | 20000921 | ||
| 58 | Constant | Public | Type reference (TYPE) | SYMSGNO | '211' | Control Could not be Created | 19980424 | ||
| 59 | Constant | Public | Type reference (TYPE) | SYMSGNO | '215' | Product does not run with GUI | 19980424 | ||
| 60 | Constant | Public | Type reference (TYPE) | SYMSGNO | '213' | Data formatting error | 19980424 | ||
| 61 | Constant | Public | Type reference (TYPE) | SYMSGNO | '224' | Product does not have a technical name | 19980424 | ||
| 62 | Constant | Public | Type reference (TYPE) | SYMSGNO | '225' | Product not available | 19980424 | ||
| 63 | Constant | Public | Type reference (TYPE) | SYMSGNO | '221' | Graphic product does not support function | 19980424 | ||
| 64 | Constant | Public | Type reference (TYPE) | SYMSGNO | '226' | No reference for graphics product | 19980424 | ||
| 65 | Constant | Public | Type reference (TYPE) | SYMSGNO | '209' | Unknown graphics product | 19980424 | ||
| 66 | Constant | Public | Type reference (TYPE) | SYMSGNO | '201' | Proxy control missing for characters | 19980424 | ||
| 67 | Constant | Public | Type reference (TYPE) | SYMSGNO | '218' | Event could not be registered | 19980424 | ||
| 68 | Constant | Public | Type reference (TYPE) | SYMSGNO | '220' | Could not read correctly from event table | 19980424 | ||
| 69 | Constant | Public | Type reference (TYPE) | SYMSGNO | '212' | Data could not be sent to graphic | 19980424 | ||
| 70 | Constant | Public | Type reference (TYPE) | SYMSGNO | '232' | GP is not active | 19980617 | ||
| 71 | Constant | Public | Type reference (TYPE) | SYMSGNO | '223' | Event can not be processed | 19980424 | ||
| 72 | Constant | Public | Type reference (TYPE) | SYMSGNO | '203' | Unknown parameter | 19980424 | ||
| 73 | Constant | Public | Type reference (TYPE) | SYMSGNO | '216' | No free Win ID found | 19980424 | ||
| 74 | Constant | Public | Type reference (TYPE) | SYMSGNO | '214' | Could not determine front end version | 19980424 | ||
| 75 | Constant | Public | Type reference (TYPE) | SYMSGNO | '409' | Double slave proxy in syncjob | 19980424 | ||
| 76 | Constant | Public | Type reference (TYPE) | SYMSGNO | '402' | GP already subscribed | 19980424 | ||
| 77 | Constant | Public | Type reference (TYPE) | SYMSGNO | '401' | Win ID already exists | 19980424 | ||
| 78 | Constant | Public | Type reference (TYPE) | SYMSGNO | '408' | Gp sending event is unknown | 19980424 | ||
| 79 | Constant | Public | Type reference (TYPE) | SYMSGNO | '410' | GP unknown | 19990818 | ||
| 80 | Constant | Public | Type reference (TYPE) | SYMSGNO | '403' | MUX initial | 19980424 | ||
| 81 | Constant | Public | Type reference (TYPE) | SYMSGNO | '406' | Double synjob key | 19980424 | ||
| 82 | Constant | Public | Type reference (TYPE) | SYMSGNO | '405' | Syncjob does not exist | 19980424 | ||
| 83 | Constant | Public | Type reference (TYPE) | SYMSGNO | '407' | No complete syncjob key | 19980424 | ||
| 84 | Constant | Public | Type reference (TYPE) | SYMSGNO | '404' | GP could not be added/deleted | 19980424 | ||
| 85 | Constant | Public | Type reference (TYPE) | SYMSGNO | '803' | Error outside GFW kernel | 19980424 | ||
| 86 | Static Attribute | Public | Type reference (TYPE) | CHAR25 | 'GFW_ITS_RFC_DEST' | Destination for RFC calls to get images for ITS | 19990921 | ||
| 87 | Constant | Public | Type reference (TYPE) | SYMSGNO | '013' | GP already exists, call Notify with AREAD | 19980508 | ||
| 88 | Constant | Public | Type reference (TYPE) | SYMSGNO | '007' | Get method returns set of values | 19980506 | ||
| 89 | Static Attribute | Private | Type reference (TYPE) | I | last time measured | 19990408 | |||
| 90 | Constant | Public | Type reference (TYPE) | CHAR5 | 'APPLG' | Message error class | 19980424 | ||
| 91 | Static Attribute | Public | Type reference (TYPE) | GFW_BOOLEAN | gfw_false | Message log activated | 19990201 | ||
| 92 | Static Attribute | Public | Type reference (TYPE) | GFW_BOOLEAN | gfw_false | Message log initialized | 19990201 | ||
| 93 | Static Attribute | Private | Type reference (TYPE) | CHAR32 | ID of log inb memory | 19990201 | |||
| 94 | Constant | Public | Type reference (TYPE) | SYMSGNO | '000' | No error, operation successful | 19980424 | ||
| 95 | Static Attribute | Public | Type reference (TYPE) | GFW_BOOLEAN | gfw_false | Time protocol activated | 19990408 | ||
| 96 | Static Attribute | Private | Type reference (TYPE) | INDX-SRTFD | ID of time protocol in memory area | 19990505 | |||
| 97 | Constant | Public | Type reference (TYPE) | SYMSGNO | '236' | SET_DC_NAMES: Dim3 not yet supported | 19981013 | ||
| 98 | Constant | Public | Type reference (TYPE) | SYMSGNO | '238' | No DC_ITEM found for column | 19990414 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Static method | Public | Constructor | CLASS_CONSTRUCTOR | 19990201 | |
| 2 | Static method | Public | Method | Delete all logged messages | 19980810 | |
| 3 | Static method | Public | Method | Display message for given return value | 19980424 | |
| 4 | Static method | Public | Method | Display logged messages | 19980810 | |
| 5 | Static method | Public | Method | Include message in log | 19980810 | |
| 6 | Static method | Public | Method | Write measuring point in time protocol | 19990408 |
Events
Class CL_GFW has no event.
Types
Class CL_GFW has no local type.
Method Signatures
Method CLASS_CONSTRUCTOR Signature
Method CLASS_CONSTRUCTOR on class CL_GFW has no parameter.
Method CLASS_CONSTRUCTOR on class CL_GFW has no exception.
Method CLEAR_MSG_PROTOCOL Signature
Method CLEAR_MSG_PROTOCOL on class CL_GFW has no parameter.
Method CLEAR_MSG_PROTOCOL on class CL_GFW has no exception.
Method SHOW_MSG Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | F1 | Call by reference | Type reference (TYPE) | TEXT40 | Text for placeholder &1 in the message | 19980507 | |||
| 2 | F2 | Call by reference | Type reference (TYPE) | TEXT40 | Text for placeholder &2 in the message | 19980507 | |||
| 3 | F3 | Call by reference | Type reference (TYPE) | TEXT40 | Text for placeholder &3 in the message | 19980507 | |||
| 4 | F4 | Call by reference | Type reference (TYPE) | TEXT40 | Text for placeholder &4 in the message | 19980507 | |||
| 5 | MSGNO | Call by reference | Type reference (TYPE) | SYMSGNO | Return value/message number | 19980424 | |||
| 6 | MSGTYPE | Call by reference | Type reference (TYPE) | SYMSGTY | 'E' | Message type (error, warning,...) | 19980424 |
Method SHOW_MSG on class CL_GFW has no exception.
Method SHOW_MSG_PROTOCOL Signature
Method SHOW_MSG_PROTOCOL on class CL_GFW has no parameter.
Method SHOW_MSG_PROTOCOL on class CL_GFW has no exception.
Method WRITE_MSG_PROTOCOL Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | METHNAME | Call by reference | Type reference (TYPE) | TEXT40 | Name of calling class and method | 19980811 | |||
| 2 | MSGNO | Value transfer | Type reference (TYPE) | SYMSGNO | Return code | 19980810 | |||
| 3 | MSGTYPE | Value transfer | Type reference (TYPE) | SYMSGTY | 'W' | Message type | 19980810 |
Method WRITE_MSG_PROTOCOL on class CL_GFW has no exception.
Method WRITE_TIME_PROTOCOL Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DESCRIPTION | Call by reference | Type reference (TYPE) | TEXT80 | Beschreibung des Meßpunktes | 19990408 |
Method WRITE_TIME_PROTOCOL on class CL_GFW has no exception.
History
| Last changed by/on | SAP | 19990125 |
| SAP Release Created in |