SAP ABAP Class CL_FCOM_PBC_MONITOR (Class for Application FCOM_PBC_MONITOR)
Hierarchy
EA-FIN (Software Component) EA-FIN
   EP-PCT-MGR-CO (Application Component) Business Package for Manager Self-Service (FI)
     FCOM_MONITOR (Package) CO Monitors
Properties
Class CL_FCOM_PBC_MONITOR  
Short Description Class for Application FCOM_PBC_MONITOR    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package FCOM_MONITOR   CO Monitors 
Created 20061221   SAP 
Last change 20100310   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class CL_FCOM_PBC_MONITOR has no forward declaration.
Interfaces
Class CL_FCOM_PBC_MONITOR has no interface implemented.
Friends
Class CL_FCOM_PBC_MONITOR has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 MD_PERSID_PCD Instance attribute Private Type reference (TYPE) FPB_DIALOGID Personalization Dialog 20070110
2 MD_SINGLEWAERS Instance attribute Private Type reference (TYPE) WDY_BOOLEAN Supplement for True Boolean Type: 'X' == True '' == False 20070112
3 MD_UNAME Instance attribute Private Attribute reference (LIKE) SY-UNAME User Name 20070110
4 MR_APPLICATION Instance attribute Private Type reference (TYPE) STRING 20070109
5 MR_TYPE Instance attribute Private Type reference (TYPE) STRING 20070109
6 MT_FIELDCAT Instance attribute Private See coding 20070109
7 MT_PCD_PARAMETERS Instance attribute Private Type reference (TYPE) FPB_T_VALUES Table of Values 20070110
Methods
# Method Level Visibility Method type Description Created on
1 CONSTRUCTOR Instance method Public Constructor CONSTRUCTOR 20070109
2 GET_DATA Instance method Public Method 20061221
3 GET_HEADER_TEXT Instance method Public Method 20070109
4 GET_PARAMETER_FROM_PCD Instance method Public Method 20070110
5 GET_PCD_FOR_PERS Instance method Public Method 20061221
6 INITIALIZE_DATA Instance method Public Method 20070110
7 MODIFY_VIEW Instance method Public Method 20070109
Events
Class CL_FCOM_PBC_MONITOR has no event.
Types
Class CL_FCOM_PBC_MONITOR has no local type.
Method Signatures

Method CONSTRUCTOR Signature

Method CONSTRUCTOR on class CL_FCOM_PBC_MONITOR has no parameter.
Method CONSTRUCTOR on class CL_FCOM_PBC_MONITOR has no exception.

Method GET_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IR_CONTEXT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_NODE WebDynpro: Schnittstelle für Kontext Knoten 20061221
2 Importing MESSAGE_MANAGER Call by reference Object reference (TYPE REF TO) IF_WD_MESSAGE_MANAGER Message-Manager 20061222

Method GET_DATA on class CL_FCOM_PBC_MONITOR has no exception.

Method GET_HEADER_TEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_HEADERTEXT Call by reference Type reference (TYPE) STRING 20070109
2 Importing IO_CONTEXT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_NODE WebDynpro: Schnittstelle für Kontext Knoten 20070109

Method GET_HEADER_TEXT on class CL_FCOM_PBC_MONITOR has no exception.

Method GET_PARAMETER_FROM_PCD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EP_VALUE Call by reference Type reference (TYPE) STRING 20070110
2 Importing IP_NAME Call by reference Type reference (TYPE) STRING 20070110

Method GET_PARAMETER_FROM_PCD on class CL_FCOM_PBC_MONITOR has no exception.

Method GET_PCD_FOR_PERS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning ED_PCD_PATH Value transfer Type reference (TYPE) STRING 20061221

Method GET_PCD_FOR_PERS on class CL_FCOM_PBC_MONITOR has no exception.

Method INITIALIZE_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IR_CONTEXT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_NODE WebDynpro: Schnittstelle für Kontext Knoten 20070110
2 Importing MESSAGE_MANAGER Call by reference Object reference (TYPE REF TO) IF_WD_MESSAGE_MANAGER Message-Manager 20070110

Method INITIALIZE_DATA on class CL_FCOM_PBC_MONITOR has no exception.

Method MODIFY_VIEW Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_COL_SETTINGS Call by reference Object reference (TYPE REF TO) IF_SALV_WD_COLUMN_SETTINGS Einstellungen zur Spalte in der ALV-Ausgabe 20070109
2 Importing IO_CONTEXT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_NODE WebDynpro: Schnittstelle für Kontext Knoten 20070109

Method MODIFY_VIEW on class CL_FCOM_PBC_MONITOR has no exception.
History
Last changed by/on SAP  20100310 
SAP Release Created in 600