SAP ABAP Class CL_FA_UI_GRID_CONTROLLER (Test grid controller for ATC result display)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-TWB-TST-TCK (Application Component) ATC extensions for Technical Check
     SATC_ABAP_CHECK_SAP_FA_UI (Package) INTERNAL: - *NO* REUSE - User interface for TCK plug-ins
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  IF_SATC_AC__UI_GRID_CONTROLLER Module Verdicts: Controller for UI 20101130
Properties
Class CL_FA_UI_GRID_CONTROLLER  
Short Description Test grid controller for ATC result display    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package SATC_ABAP_CHECK_SAP_FA_UI   INTERNAL: - *NO* REUSE - User interface for TCK plug-ins 
Created 20101130   SAP 
Last change 20130531   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class CL_FA_UI_GRID_CONTROLLER has no forward declaration.
Interfaces
# Interface Abstract Final Description Created on
1 IF_SATC_AC__UI_GRID_CONTROLLER Module Verdicts: Controller for UI 20101130
Friends
Class CL_FA_UI_GRID_CONTROLLER has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 C_FCODE Constant Private See coding 20110119
2 F_DISPLAY_ID Instance attribute Protected Type reference (TYPE) SATC_D_ID Unique ID - hex 16 - raw format 20110210
Methods
# Method Level Visibility Method type Description Created on
1 _FA_ASSIGN_IPS Instance method Protected Method 20110119
2 _FA_ASSIGN_ONE4ALL Instance method Protected Method 20110119
3 _FA_CREATE_GENERIC Instance method Protected Method 20110713
4 _FA_CREATE_ONE4ALL Instance method Protected Method 20110119
5 _FA_DISPLAY_HIST Instance method Protected Method 20120314
6 _FA_DISP_IPM Instance method Protected Method 20110119
7 _FA_GET_IDS Instance method Protected Method 20110119
8 _FA_REGISTER Instance method Protected Method 20110119
9 _FA_RERUN_VERI Instance method Protected Method 20111018
10 _INPUT_IP_NUMBER Instance method Protected Method 20110119
Events
Class CL_FA_UI_GRID_CONTROLLER has no event.
Types
# Type Visibility Typing Associated Type Description Created on Type Source
1 TY_S_LINE Protected Type reference (TYPE) SATC_S_FA__UI_MESSAGE_HEADER 20110119
2 TY_T_INTEGERS Protected See coding 20110119 ty_T_Integers type standard table of i with default key
3 TY_T_LINES Protected Type reference (TYPE) SATC_T_FA__UI_MESSAGE_HEADERS 20110119
Method Signatures

Method _FA_ASSIGN_IPS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20110119
2 Importing IP_NR1 Call by reference Type reference (TYPE) SATCIPSYS 20110119
3 Importing IP_NR2 Call by reference Type reference (TYPE) SATCIPNUM 20110119
4 Importing IP_NR3 Call by reference Type reference (TYPE) SATCIPYEAR 20110119

Method _FA_ASSIGN_IPS on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_ASSIGN_ONE4ALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_FORCED Call by reference Type reference (TYPE) INT4 20110119
2 Importing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20110119

Method _FA_ASSIGN_ONE4ALL on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_CREATE_GENERIC Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_FORCED Call by reference Type reference (TYPE) INT4 20110713
2 Importing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20110713

Method _FA_CREATE_GENERIC on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_CREATE_ONE4ALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_FORCED Call by reference Type reference (TYPE) INT4 20110119
2 Importing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20110119

Method _FA_CREATE_ONE4ALL on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_DISPLAY_HIST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20120314

Method _FA_DISPLAY_HIST on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_DISP_IPM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_IP Call by reference Type reference (TYPE) CHAR40 20110119

Method _FA_DISP_IPM on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_GET_IDS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_IDS Call by reference Type reference (TYPE) TY_T_INTEGERS 20110119
2 Importing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20110119

Method _FA_GET_IDS on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_REGISTER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20110119

Method _FA_REGISTER on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _FA_RERUN_VERI Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_LINES Call by reference Type reference (TYPE) TY_T_LINES 20111018

Method _FA_RERUN_VERI on class CL_FA_UI_GRID_CONTROLLER has no exception.

Method _INPUT_IP_NUMBER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting RET_CODE Call by reference Type reference (TYPE) I 20110119

Method _INPUT_IP_NUMBER on class CL_FA_UI_GRID_CONTROLLER has no exception.
History
Last changed by/on SAP  20130531 
SAP Release Created in 802