SAP ABAP Class CL_ESH_TAU_CHK_TOOLS (Test Automation (For UNIT Test and Appliance Test Framework))
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-EIM-ESH (Application Component) NetWeaver Enterprise Search
     S_ESH_TEST (Package) Test (Search Hub + Appliance), Smoke Test, Unit Test, EPM
Properties
Class CL_ESH_TAU_CHK_TOOLS  
Short Description Test Automation (For UNIT Test and Appliance Test Framework)    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package S_ESH_TEST   Test (Search Hub + Appliance), Smoke Test, Unit Test, EPM 
Created 20110201   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 CL_ESH_TAU_EPM_SWC_AUTOTEST Forward declaration class (CLASS c DEFINITION DEFERRED)  Forward declaration class (CLASS c DEFINITION DEFERRED)
Interfaces
Class CL_ESH_TAU_CHK_TOOLS has no interface implemented.
Friends
Class CL_ESH_TAU_CHK_TOOLS has no friend class.
Attributes
Class CL_ESH_TAU_CHK_TOOLS has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CHECK_EPM_EXISTENCE Static method Public Method Check the existence of EPM Auto SWC BO search connectors 20110201
2 CHECK_ESH_ADMIN_AUTHORIZATIONS Static method Public Method Check the authorizations 20110207
3 CHECK_ESH_BACKEND_RFC_CONN Static method Public Method Check for To-Back-End RFC Destinations 20110201
4 CHECK_TREX_DESTINATION Static method Public Method Check the TREX RFC destination of Enterprise Search 20110201
5 CREATE_EPM_SEARCH_CONNECTOR Static method Public Method Create search connectors (Default SC's of EPM: Auto SWC) 20110207
6 EPM_IMPORT_SWC Static method Public Method Import of Software component 20110204
7 GET_ESH_LOCAL_CONNECTION Static method Public Method Get local connection GUID 20110202
8 TRIGGER_SC_STATUS_UPDATE Static method Public Method Update the connectors 20110203
9 UPDATE_MODIFIED_CONNECTORS_TST Static method Private Method 20110207
10 WAIT_FOR_CONNECTOR_CREATED_TST Static method Public Method Wait till the connectors gets created or reaches timeout 20110207
Events
Class CL_ESH_TAU_CHK_TOOLS has no event.
Types
Class CL_ESH_TAU_CHK_TOOLS has no local type.
Method Signatures

Method CHECK_EPM_EXISTENCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_AVAILABLE Call by reference Type reference (TYPE) ABAP_BOOL 20110207
2 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ESH_E_TST_FWK_SEVERITY Task Severity 20110201
3 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110201
4 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110201

Method CHECK_EPM_EXISTENCE on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method CHECK_ESH_ADMIN_AUTHORIZATIONS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ESH_E_TST_FWK_SEVERITY Task Severity 20110207
2 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110207
3 Importing IV_CONNECTION_GUID Call by reference Type reference (TYPE) ESH_E_OM_SYSTEM System 20110207
4 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110207
5 Importing IV_SYSREL Call by reference Type reference (TYPE) ESH_E_OM_SYSREL Software Component 20110207

Method CHECK_ESH_ADMIN_AUTHORIZATIONS on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method CHECK_ESH_BACKEND_RFC_CONN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ABAP_BOOL 20110201
2 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110201
3 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110201

Method CHECK_ESH_BACKEND_RFC_CONN on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method CHECK_TREX_DESTINATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ABAP_BOOL 20110201
2 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110201
3 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110201

Method CHECK_TREX_DESTINATION on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method CREATE_EPM_SEARCH_CONNECTOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ESH_E_TST_FWK_SEVERITY Task Severity 20110207
2 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110207
3 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110207
4 Importing IV_SYSREL Call by reference Type reference (TYPE) ESH_E_OM_SYSREL Software Component 20110207

Method CREATE_EPM_SEARCH_CONNECTOR on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method EPM_IMPORT_SWC Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_MESSAGES Call by reference Type reference (TYPE) BAPIRETTAB Table with BAPI Return Information 20110204
2 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ESH_E_TST_FWK_SEVERITY Task Severity 20110204
3 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110204
4 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110204
5 Importing IV_PROVIDER_ID Call by reference Type reference (TYPE) ESH_E_IF_PROVIDER_ID Provider ID (Default, CL_ESH_TAU_EPM_SWC_AUTOTEST) 20110204
6 Importing IV_SYSREL Call by reference Type reference (TYPE) ESH_E_OM_SYSREL Software Component (Default, Z_ESH_EPM_AUTO) 20110204

Method EPM_IMPORT_SWC on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method GET_ESH_LOCAL_CONNECTION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_CONNECTION_GUID Call by reference Type reference (TYPE) ESH_E_ADM_CONNECTION_GUID Connection GUID 20110202
2 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ESH_E_TST_FWK_SEVERITY Task Severity 20110202
3 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110202
4 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL 20110202

Method GET_ESH_LOCAL_CONNECTION on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method TRIGGER_SC_STATUS_UPDATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ESH_E_TST_FWK_SEVERITY Task Severity 20110203
2 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110203
3 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110203
4 Importing IV_SC_ID Call by reference Type reference (TYPE) ESH_E_IF_SEARCH_CONNECTOR_ID Search Connector ID 20110203

Method TRIGGER_SC_STATUS_UPDATE on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method UPDATE_MODIFIED_CONNECTORS_TST Signature

Method UPDATE_MODIFIED_CONNECTORS_TST on class CL_ESH_TAU_CHK_TOOLS has no parameter.
Method UPDATE_MODIFIED_CONNECTORS_TST on class CL_ESH_TAU_CHK_TOOLS has no exception.

Method WAIT_FOR_CONNECTOR_CREATED_TST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RESULT_SEVERITY Call by reference Type reference (TYPE) ESH_E_TST_FWK_SEVERITY Task Severity 20110207
2 Importing IR_LOG Call by reference Object reference (TYPE REF TO) CL_ESH_TST_HIL_LOG_HIERARCHY Hierarchical Logging 20110207
3 Importing IV_CONNECTION_GUID Call by reference Type reference (TYPE) ESH_E_ADM_CONNECTION_GUID Connection GUID 20110207
4 Importing IV_IS_UNITTEST Call by reference Type reference (TYPE) ABAP_BOOL Call from: Test Console - abap_false, Unit test - abap_true 20110207
5 Importing IV_SC_ID Call by reference Type reference (TYPE) ESH_E_IF_SEARCH_CONNECTOR_ID Search Connector ID 20110207

Method WAIT_FOR_CONNECTOR_CREATED_TST on class CL_ESH_TAU_CHK_TOOLS has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in 731