SAP ABAP Class CL_COCF_IS_MP (Information System and Mass Processing Function)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
PP-SFC (Application Component) Production Orders
⤷
COCF (Package) Order and Confirmation Data
⤷
⤷
Properties
| Class | CL_COCF_IS_MP | |
| Short Description | Information System and Mass Processing Function | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | COCF | Order and Confirmation Data |
| Created | 20060316 | SAP |
| Last change | 20100310 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_COCF_IS_MP has no interface implemented.
Friends
Class CL_COCF_IS_MP has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Public | Type reference (TYPE) | RALDB_REPO | 'PPIO_ENTRY' | Report name | 20060831 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Static method | Public | Method | Check Object Type | 20060316 | |
| 2 | Static method | Public | Method | Check Variant F4 Help of Customizing | 20060322 | |
| 3 | Static method | Public | Method | Determination of Parameters for Mass-Processing Variant | 20060614 | |
| 4 | Static method | Public | Method | Readout of Variant Parameters | 20060616 |
Events
Class CL_COCF_IS_MP has no event.
Types
Class CL_COCF_IS_MP has no local type.
Method Signatures
Method CHECK_OBJECT_TYPE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_OBJECT_TYPE | Call by reference | Type reference (TYPE) | POWL_TYPE_TY | POWL Objekttyp | 20060316 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Objekttyp existiert nicht | 20060316 | ||
| 2 | Objekttyp passt nicht zur Feederklasse CL_RMAN_PRSP_IS_MP | 20060316 |
Method CHECK_VAR_CUST_PARAMETERS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_VAR_CUST_PARAMETERS | Call by reference | Type reference (TYPE) | COCF_S_VAR_CUST_PARAMETERS | Parameter für F4-Hilfe Customizing zur Variante IS/MP | 20060322 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Customizing Parameter nicht gültig | 20060322 |
Method GET_FUNCTION_PARAMETERS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ES_FCTGEN | Call by reference | Type reference (TYPE) | COWRK_S_FCT_GENERAL | 20060614 | ||||
| 2 | ET_FCTHDR | Call by reference | Type reference (TYPE) | COWRK_T_FCT_HEADER | 20060614 | ||||
| 3 | ET_FCTPAR | Call by reference | Type reference (TYPE) | COWRK_T_FCT_PARAMETERS | 20060614 | ||||
| 4 | IS_KEY | Call by reference | Type reference (TYPE) | RSVARKEY | Übergabestruktur für Report- und Variantenname | 20060614 |
Method GET_FUNCTION_PARAMETERS on class CL_COCF_IS_MP has no exception.
Method GET_PARAMETERS_FROM_VARIANT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ES_OBJECTS_TO_READ | Call by reference | Type reference (TYPE) | COIS_S_OBJECTS_READ | Enthält welche Objekte von DB gelesen werden sollen | 20060616 | |||
| 2 | ET_STATUS_CMP | Call by reference | Type reference (TYPE) | SEL_STATUS_TAB | Statustabelle für Selektion | 20060616 | |||
| 3 | ET_STATUS_HDR | Call by reference | Type reference (TYPE) | SEL_STATUS_TAB | Statustabelle für Selektion | 20060616 | |||
| 4 | ET_STATUS_OPR | Call by reference | Type reference (TYPE) | SEL_STATUS_TAB | Statustabelle für Selektion | 20060616 | |||
| 5 | EV_PLANNED_ORD_SEL | Call by reference | Type reference (TYPE) | FLAG | allgemeines flag | 20060616 | |||
| 6 | EV_PROC_ORD_SEL | Call by reference | Type reference (TYPE) | FLAG | allgemeines flag | 20060616 | |||
| 7 | EV_PROD_ORD_SEL | Call by reference | Type reference (TYPE) | FLAG | allgemeines flag | 20060616 | |||
| 8 | EV_REM_ONLY_SEL | Call by reference | Type reference (TYPE) | FLAG | allgemeines flag | 20060616 | |||
| 9 | IT_VARIANT_CONTENT | Call by reference | Type reference (TYPE) | RSPARAMS_TT | rsparams Tabelle | 20060616 | |||
| 10 | IV_ORDER_CAT | Call by reference | Type reference (TYPE) | AUFTYP | Auftragstyp | 20060915 | |||
| 11 | IV_VARIANT | Call by reference | Type reference (TYPE) | VARIANT | ABAP: Name einer Variante (ohne Programmname) | 20060616 |
Method GET_PARAMETERS_FROM_VARIANT on class CL_COCF_IS_MP has no exception.
History
| Last changed by/on | SAP | 20100310 |
| SAP Release Created in | 700 |