SAP ABAP Class CL_BSP_HISTORY_MODEL_CNTL (BSP History data)
Hierarchy
☛
SAP_ABA (Software Component) Cross-Application Component
⤷
CA-GTF-PCU-PRO (Application Component) Dialog People-Centric UI for Products
⤷
COM_PRODUCT_BSP (Package) Product Master BSP Interface (Distribution Chain Dependent)
⤷
⤷
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_CRM_BSP_INIT_IL | Interface for Initialization | 20021205 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_CRM_BSP_MODEL_ACCESS_IL | Application Interface to BSP IL | 20021120 |
| 3 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_CRM_BSP_PROCESS_IL | Interface for Process Methods | 20021205 |
Properties
| Class | CL_BSP_HISTORY_MODEL_CNTL | |
| Short Description | BSP History data | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | COM_PRODUCT_BSP | Product Master BSP Interface (Distribution Chain Dependent) |
| Created | 20021113 | SAP |
| Last change | 20050213 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | IF_CRM_BSP_INIT_IL | Interface for Initialization | 20021205 | ||
| 2 | IF_CRM_BSP_MODEL_ACCESS_IL | Application Interface to BSP IL | 20021120 | ||
| 3 | IF_CRM_BSP_PROCESS_IL | Interface for Process Methods | 20021205 |
Friends
Class CL_BSP_HISTORY_MODEL_CNTL has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Instance attribute | Public | Object reference (TYPE REF TO) | IF_CRM_BSP_MODEL_ACCESS_IL | Application Interface to BSP IL | 20050112 | |||
| 2 | Instance attribute | Public | Object reference (TYPE REF TO) | CL_CRM_BSP_MAC_LINK | BSP Interaction Layer | 20021223 | |||
| 3 | Instance attribute | Public | Object reference (TYPE REF TO) | IF_CRM_BSP_MODEL_ACCESS_IL | Application Interface to BSP IL | 20021219 | |||
| 4 | Instance attribute | Public | Object reference (TYPE REF TO) | IF_CRM_BSP_MODEL_ACCESS_IL | Application Interface to BSP IL | 20050111 | |||
| 5 | Instance attribute | Private | Type reference (TYPE) | COMT_PRODUCT_GUID | Internal Unique Identifier of Product | 20021223 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Constructor | 20021219 | ||
| 2 | Instance method | Public | Method | Read event history data | 20021113 | |
| 3 | Instance method | Public | Method | Sets field attributes values | 20021219 | |
| 4 | Instance method | Public | Method | sets the object key | 20021223 |
Events
Class CL_BSP_HISTORY_MODEL_CNTL has no event.
Types
Class CL_BSP_HISTORY_MODEL_CNTL has no local type.
Method Signatures
Method CONSTRUCTOR Signature
Method CONSTRUCTOR on class CL_BSP_HISTORY_MODEL_CNTL has no parameter.
Method CONSTRUCTOR on class CL_BSP_HISTORY_MODEL_CNTL has no exception.
Method READ_ATTR_HISTORY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_FIELD_ATTRIBUTE | Call by reference | Type reference (TYPE) | CRMT_BSP_FIELDATTRIB_TAB | Feldattribute | 20021113 | |||
| 2 | ET_SCREEN_STRUCTURE | Call by reference | Type reference (TYPE) | TABLE | 20021113 | ||||
| 3 | IT_OBJECT_KEY | Call by reference | Type reference (TYPE) | CRMT_BSP_OBJECTKEY_TAB | Objektschlüsseltabelle | 20021113 | |||
| 4 | IV_LOCK | Call by reference | Type reference (TYPE) | CRMT_BOOLEAN | Logische Variable | 20021113 | |||
| 5 | IV_SCREEN_STRUCTURE_NAME | Call by reference | Type reference (TYPE) | CRMT_BSP_SCRSTRUCNAME | Strukturname für Anzeigefeld | 20021113 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Historiensätze nicht gefunden | 20021115 |
Method SET_FIELD_ATTRIBUTES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_FIELD_ATTRIBUTE | Call by reference | Type reference (TYPE) | CRMT_BSP_FIELDATTRIB_TAB | Feldattribute | 20021219 | |||
| 2 | IV_PRODUCT_GUID | Call by reference | Type reference (TYPE) | COMT_PRODUCT_GUID | Interne eindeutige Produkt-ID | 20021219 | |||
| 3 | IV_SCREEN_STRUCTURE_NAME | Call by reference | Type reference (TYPE) | CRMT_BSP_SCRSTRUCNAME | Strukturname für Anzeigefeld | 20030122 |
Method SET_FIELD_ATTRIBUTES on class CL_BSP_HISTORY_MODEL_CNTL has no exception.
Method SET_OBJECT_KEY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_OBJECT_GUID | Call by reference | Type reference (TYPE) | COMT_PRODUCT_GUID | Interne eindeutige Produkt-ID | 20021223 |
Method SET_OBJECT_KEY on class CL_BSP_HISTORY_MODEL_CNTL has no exception.
History
| Last changed by/on | SAP | 20050213 |
| SAP Release Created in | 400 |