SAP ABAP Class CL_BORGR_DIALOG_FILTER (Goods Receipt Automotive: Filter Settings)
Hierarchy
☛
SAP_APPL (Software Component) Logistics and Accounting
⤷
LO-SPM-INB (Application Component) Goods Receipt Process
⤷
LE_BOR (Package) Goods Receipt Processing for Inbound Delivery

⤷

⤷

Properties
Class | CL_BORGR_DIALOG_FILTER | |
Short Description | Goods Receipt Automotive: Filter Settings | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | LE_BOR | Goods Receipt Processing for Inbound Delivery |
Created | 20001229 | SAP |
Last change | 20050411 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_BORGR_DIALOG_FILTER has no forward declaration.
Interfaces
Class CL_BORGR_DIALOG_FILTER has no interface implemented.
Friends
Class CL_BORGR_DIALOG_FILTER has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Inbound Deliveries Without Errors | 20010304 | ||
2 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Incorrect | 20010304 | ||
3 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | WFCID | Factory Calendar | 20010105 | ||
4 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | C | A_DATEFLAG | 20001229 | ||
5 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | BORGR_DAYS | Time Difference in Days | 20010105 | ||
6 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | FKTEXT | Object Text | 20010107 | ||
7 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Inbound Deliveries on Hold | 20010304 | ||
8 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Incomplete Inbound Deliveries | 20010304 | ||
9 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | LVS_LBZOT | A_LBZOT | 20001229 | ||
10 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | LGBZO | A_LGBZO | 20001229 | ||
11 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | LGNUM | A_LGNUM | 20001229 | ||
12 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | LGOBE | A_LGOBE | 20001229 | ||
13 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | LGORT_D | A_LGORT | 20001229 | ||
14 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | LGTOR | A_LGTOR | 20001229 | ||
15 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | LVS_LTORT | A_LTORT | 20001229 | ||
16 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | NAME1 | A_NAME1 | 20001229 | ||
17 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Missing in the Shipment | 20021117 | ||
18 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Transferred Inbound Deliveries | 20010304 | ||
19 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Checkbox | 20050309 | ||
20 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Checkbox | 20050309 | ||
21 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | XFELD | Checkbox | 20050309 | ||
22 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | C | A_TYPE_COMPLETE | 20001229 | ||
23 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | VSTEL | Shipping point/receiving point | 20001229 | ||
24 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | VTEXT | A_VTEXT | 20001229 | ||
25 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | WERKS_D | A_WERKS | 20001229 | ||
26 | ![]() |
Constant | Public | Type reference (TYPE) | CHAR1 | 'E' | Result not OK | 20001229 | |
27 | ![]() |
Constant | Public | Type reference (TYPE) | CHAR1 | 'X' | Result OK | 20001229 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Protected | Method | Maintain Filter Settings for Inbound Deliveries with Errors | 20010304 |
2 | ![]() |
Instance method | Public | Constructor | Constructor | 20001229 |
3 | ![]() |
Static method | Public | Method | Check Factory Calendar | 20010107 |
4 | ![]() |
Static method | Public | Method | Check Whether Unloading Point OK | 20001229 |
5 | ![]() |
Static method | Public | Method | Check Whether Storage Location OK | 20001229 |
6 | ![]() |
Static method | Public | Method | Check Whether Unloading Zone OK | 20001229 |
7 | ![]() |
Static method | Public | Method | Check LGTOR/LGBZO: Only one of the Options Can Be Entered | 20001229 |
8 | ![]() |
Static method | Public | Method | Check Whether Goods Receiving Point OK | 20001229 |
9 | ![]() |
Static method | Public | Method | Check Whether Plant OK | 20001229 |
10 | ![]() |
Static method | Public | Method | Show F4 Help for Goods Receiving Point | 20001229 |
11 | ![]() |
Instance method | Public | Method | Output Filter Settings | 20001229 |
12 | ![]() |
Instance method | Public | Method | Make Filter Settings | 20001229 |
Events
Class CL_BORGR_DIALOG_FILTER has no event.
Types
Class CL_BORGR_DIALOG_FILTER has no local type.
Method Signatures
Method CALCULATE_COMPLETNESS_FILTER Signature
Method CALCULATE_COMPLETNESS_FILTER on class CL_BORGR_DIALOG_FILTER has no parameter.
Method CALCULATE_COMPLETNESS_FILTER on class CL_BORGR_DIALOG_FILTER has no exception.
Method CONSTRUCTOR Signature
Method CONSTRUCTOR on class CL_BORGR_DIALOG_FILTER has no parameter.
Method CONSTRUCTOR on class CL_BORGR_DIALOG_FILTER has no exception.
Method FILTER_CHECK_FCAL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_FKTEXT | Call by reference | Type reference (TYPE) | FKTEXT | Text zum Objekt | 20010107 | ||
2 | ![]() |
E_RESULT | Call by reference | Type reference (TYPE) | C | Resultat der Prüfung | 20010107 | ||
3 | ![]() |
I_IDENT | Call by reference | Type reference (TYPE) | WFCID | Fabrikkalender | 20010107 | ||
4 | ![]() |
I_NO_MESSAGE | Call by reference | Type reference (TYPE) | XFELD | Feld zum Ankreuzen | 20010107 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Prüfung nicht ok | 20010107 |
Method FILTER_CHECK_LGBZO Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_LBZOT | Call by reference | Type reference (TYPE) | LVS_LBZOT | Text Bereitstellungszone | 20001229 | ||
2 | ![]() |
E_RESULT | Call by reference | Type reference (TYPE) | C | Resultat der Prüfung | 20001229 | ||
3 | ![]() |
I_LGBZO | Call by reference | Type reference (TYPE) | LGBZO | Bereitstellungszone zur Lagernummer | 20001229 | ||
4 | ![]() |
I_LGORT | Call by reference | Type reference (TYPE) | LGORT_D | Lagerort | 20001229 | ||
5 | ![]() |
I_NO_MESSAGE | Call by reference | Type reference (TYPE) | XFELD | Keine Nachricht auslösen | 20001229 | ||
6 | ![]() |
I_WERKS | Call by reference | Type reference (TYPE) | WERKS_D | Werk | 20001229 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Bereitstellzone nicht ok, Nachricht ausgelöst | 20001229 |
Method FILTER_CHECK_LGORT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_LGOBE | Call by reference | Type reference (TYPE) | LGOBE | Lagerortbezeichnung | 20001229 | ||
2 | ![]() |
E_RESULT | Call by reference | Type reference (TYPE) | C | Resultat der Prüfung | 20001229 | ||
3 | ![]() |
I_LGORT | Call by reference | Type reference (TYPE) | LGORT_D | Lagerort | 20001229 | ||
4 | ![]() |
I_NO_MESSAGE | Call by reference | Type reference (TYPE) | XFELD | Keine Nachricht auslösen | 20001229 | ||
5 | ![]() |
I_WERKS | Call by reference | Type reference (TYPE) | WERKS_D | Werk | 20001229 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Lagerort nicht ok, Nachricht ausgelöst | 20001229 |
Method FILTER_CHECK_LGTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_LTORT | Call by reference | Type reference (TYPE) | LVS_LTORT | Tor-Text | 20001229 | ||
2 | ![]() |
E_RESULT | Call by reference | Type reference (TYPE) | C | Resultat der Prüfung | 20001229 | ||
3 | ![]() |
I_LGORT | Call by reference | Type reference (TYPE) | LGORT_D | Lagerort | 20001229 | ||
4 | ![]() |
I_LGTOR | Call by reference | Type reference (TYPE) | LGTOR | Tor zur Lagernummer | 20001229 | ||
5 | ![]() |
I_NO_MESSAGE | Call by reference | Type reference (TYPE) | XFELD | Keine Nachricht auslösen | 20001229 | ||
6 | ![]() |
I_WERKS | Call by reference | Type reference (TYPE) | WERKS_D | Werk | 20001229 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Lagertor nicht ok, Nachricht ausgelöst | 20001229 |
Method FILTER_CHECK_ONE_ENTRY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_RESULT | Call by reference | Type reference (TYPE) | C | Resultat der Prüfung | 20001229 | ||
2 | ![]() |
I_LGBZO | Call by reference | Type reference (TYPE) | LGBZO | Bereitstellungszone zur Lagernummer | 20001229 | ||
3 | ![]() |
I_LGTOR | Call by reference | Type reference (TYPE) | LGTOR | Tor zur Lagernummer | 20001229 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Nicht ok, beide Daten eingegeben | 20001229 |
Method FILTER_CHECK_VSTEL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_RESULT | Call by reference | Type reference (TYPE) | C | Resultat der Prüfung | 20001229 | ||
2 | ![]() |
E_VTEXT | Call by reference | Type reference (TYPE) | VTEXT | Text der Warenannahmestelle | 20001229 | ||
3 | ![]() |
I_NO_MESSAGE | Call by reference | Type reference (TYPE) | XFELD | Keine Message ausgeben | 20001229 | ||
4 | ![]() |
I_VSTEL | Call by reference | Type reference (TYPE) | VSTEL | Warenannahmestelle | 20001229 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Warenannahmestelle nicht ok, Nachricht ausgelöst | 20001229 |
Method FILTER_CHECK_WERKS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_NAME1 | Call by reference | Type reference (TYPE) | NAME1 | Name | 20001229 | ||
2 | ![]() |
E_RESULT | Call by reference | Type reference (TYPE) | C | Resulat der Prüfung | 20001229 | ||
3 | ![]() |
I_NO_MESSAGE | Call by reference | Type reference (TYPE) | XFELD | Keine Nachricht auslösen | 20001229 | ||
4 | ![]() |
I_WERKS | Call by reference | Type reference (TYPE) | WERKS_D | Werk | 20001229 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Werk nicht ok, Nachricht ausgelöst | 20001229 |
Method FILTER_F4HELP_VSTEL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_VSTEL | Call by reference | Type reference (TYPE) | VSTEL | Gewählte Warenannahmestelle | 20001229 | ||
2 | ![]() |
I_TITLE | Call by reference | Type reference (TYPE) | C | Window-Title | 20001229 |
Method FILTER_F4HELP_VSTEL on class CL_BORGR_DIALOG_FILTER has no exception.
Method GET_VALUES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_ASN_NOT_OK | Call by reference | Type reference (TYPE) | XFELD | fehlerhafte | 20010304 | ||
2 | ![]() |
E_ASN_OK | Call by reference | Type reference (TYPE) | XFELD | Fehlerfreie | 20010304 | ||
3 | ![]() |
E_CALEN | Call by reference | Type reference (TYPE) | WFCID | Fabrikkalender | 20010105 | ||
4 | ![]() |
E_DATEFLAG | Call by reference | Type reference (TYPE) | XFELD | Feld zum Ankreuzen | 20001229 | ||
5 | ![]() |
E_DAYS | Call by reference | Type reference (TYPE) | BORGR_DAYS | Bordero: Zeitabstand in Tagen | 20010105 | ||
6 | ![]() |
E_FKTEXT | Call by reference | Type reference (TYPE) | FKTEXT | Text zum Objekt | 20010107 | ||
7 | ![]() |
E_INCOMPL_ALLOWED | Call by reference | Type reference (TYPE) | XFELD | Mit Fehler 'unvollständig' | 20010304 | ||
8 | ![]() |
E_LBZOT | Call by reference | Type reference (TYPE) | LVS_LBZOT | Text Bereitstellungszone | 20001229 | ||
9 | ![]() |
E_LGBZO | Call by reference | Type reference (TYPE) | LGBZO | Bereitstellungszone zur Lagernummer | 20001229 | ||
10 | ![]() |
E_LGOBE | Call by reference | Type reference (TYPE) | LGOBE | Lagerortbezeichnung | 20001229 | ||
11 | ![]() |
E_LGORT | Call by reference | Type reference (TYPE) | LGORT_D | Lagerort | 20001229 | ||
12 | ![]() |
E_LGTOR | Call by reference | Type reference (TYPE) | LGTOR | Tor zur Lagernummer | 20001229 | ||
13 | ![]() |
E_LTORT | Call by reference | Type reference (TYPE) | LVS_LTORT | Tor-Text | 20001229 | ||
14 | ![]() |
E_NAME1 | Call by reference | Type reference (TYPE) | NAME1 | Name (Werk) | 20001229 | ||
15 | ![]() |
E_NOT_EXISTING_ALLOWED | Call by reference | Type reference (TYPE) | XFELD | Fehlende im Transport | 20021117 | ||
16 | ![]() |
E_ON_HOLD_ALLOWED | Call by reference | Type reference (TYPE) | XFELD | Gemerkte | 20010304 | ||
17 | ![]() |
E_OVERDLV_ALLOWED | Call by reference | Type reference (TYPE) | XFELD | Mit Fehler 'überliefert' | 20010304 | ||
18 | ![]() |
E_SHIP_ALL | Call by reference | Type reference (TYPE) | XFELD | Feld zum Ankreuzen | 20050313 | ||
19 | ![]() |
E_SHIP_ASN | Call by reference | Type reference (TYPE) | XFELD | Feld zum Ankreuzen | 20050313 | ||
20 | ![]() |
E_SHIP_HU | Call by reference | Type reference (TYPE) | XFELD | Feld zum Ankreuzen | 20050313 | ||
21 | ![]() |
E_TYPE_COMPLETE | Call by reference | Type reference (TYPE) | C | Komplette/Inkomplette Anl. | 20001229 | ||
22 | ![]() |
E_VSTEL | Call by reference | Type reference (TYPE) | VSTEL | Warenannahmestelle | 20001229 | ||
23 | ![]() |
E_VTEXT | Call by reference | Type reference (TYPE) | VTEXT | Bezeichnung | 20010113 | ||
24 | ![]() |
E_WERKS | Call by reference | Type reference (TYPE) | WERKS_D | Werk | 20001229 |
Method GET_VALUES on class CL_BORGR_DIALOG_FILTER has no exception.
Method SET_VALUES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_CALEN | Call by reference | Type reference (TYPE) | WFCID | Fabrikkalender | 20010105 | ||
2 | ![]() |
I_DATEFLAG | Call by reference | Type reference (TYPE) | C | Datum bis heute/alle | 20001229 | ||
3 | ![]() |
I_DAYS | Call by reference | Type reference (TYPE) | BORGR_DAYS | Bordero: Zeitabstand in Tagen | 20010105 | ||
4 | ![]() |
I_FKTEXT | Call by reference | Type reference (TYPE) | FKTEXT | Text zum Objekt | 20010107 | ||
5 | ![]() |
I_LBZOT | Call by reference | Type reference (TYPE) | LVS_LBZOT | Text Bereitstellungszone | 20001229 | ||
6 | ![]() |
I_LGBZO | Call by reference | Type reference (TYPE) | LGBZO | Bereitstellungszone zur Lagernummer | 20001229 | ||
7 | ![]() |
I_LGOBE | Call by reference | Type reference (TYPE) | LGOBE | Lagerortbezeichnung | 20001229 | ||
8 | ![]() |
I_LGORT | Call by reference | Type reference (TYPE) | LGORT_D | Lagerort | 20001229 | ||
9 | ![]() |
I_LGTOR | Call by reference | Type reference (TYPE) | LGTOR | Tor zur Lagernummer | 20001229 | ||
10 | ![]() |
I_LTORT | Call by reference | Type reference (TYPE) | LVS_LTORT | Tor-Text | 20001229 | ||
11 | ![]() |
I_NAME1 | Call by reference | Type reference (TYPE) | NAME1 | Name | 20001229 | ||
12 | ![]() |
I_SHIP_ALL | Call by reference | Type reference (TYPE) | C | 20050313 | |||
13 | ![]() |
I_SHIP_ASN | Call by reference | Type reference (TYPE) | C | 20050313 | |||
14 | ![]() |
I_SHIP_HU | Call by reference | Type reference (TYPE) | C | 20050313 | |||
15 | ![]() |
I_TYPE_COMPLETE | Call by reference | Type reference (TYPE) | C | Komlette/Inkomplette Anl. | 20001229 | ||
16 | ![]() |
I_VSTEL | Call by reference | Type reference (TYPE) | VSTEL | Versandstelle/Warenannahmestelle | 20001229 | ||
17 | ![]() |
I_VTEXT | Call by reference | Type reference (TYPE) | VTEXT | Bezeichnung | 20010113 | ||
18 | ![]() |
I_WERKS | Call by reference | Type reference (TYPE) | WERKS_D | Werk | 20001229 |
Method SET_VALUES on class CL_BORGR_DIALOG_FILTER has no exception.
History
Last changed by/on | SAP | 20050411 |
SAP Release Created in | 46C2 |