SAP ABAP Class CF_RELM_NOTICE_ASSESSMENT (Notice of Assessment (VILMNA): Factory)
Hierarchy
EA-FIN (Software Component) EA-FIN
   RE-FX-LM (Application Component) Land Use Management
     RE_LM_NA (Package) RE: Notice of Assessment
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CF_RECA_OBJECT Object That Can Be Instantiated: Factory 20050309
Properties
Class CF_RELM_NOTICE_ASSESSMENT  
Short Description Notice of Assessment (VILMNA): Factory    
Super Class CF_RECA_OBJECT Object That Can Be Instantiated: Factory 
Instantiability of a Class 0  Private 
Final    
General Data
Message Class    
Program status     
Category 0   
Package RE_LM_NA   RE: Notice of Assessment 
Created 20050309   SAP 
Last change 20100310   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 RECA1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CF_RELM_NOTICE_ASSESSMENT has no interface implemented.
Friends
Class CF_RELM_NOTICE_ASSESSMENT has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 MC_AUTH_OBJECT Constant Protected Type reference (TYPE) XUOBJECT 'F_RELM_NA' Authorization Object 20050309
Methods
# Method Level Visibility Method type Description Created on
1 CHECK_AUTHORITY Static method Public Method Checks Authorization (Generic) 20050309
2 CHECK_KEY Static method Public Method Checks Existence of Business Object Via Business Key (Exc.) 20050309
3 CHECK_KEY_TO_CREATE Static method Public Method Checks If Business Key for New Object Is Allowed 20050309
4 CONVERT_BUSKEY_TO_IDENT_KEY Static method Public Method Converts BOR Key to External Format 20050309
5 CONVERT_BUSKEY_TO_KEY Static method Public Method Converts BOR Key to the Semantic Key 20050309
6 CONVERT_KEY_TO_BUSKEY Static method Public Method Converts Semantic Key to BOR Key 20050309
7 CONVERT_KEY_TO_IDENT_KEY Static method Public Method Converts Semantic Key to External Formatting 20050309
8 CREATE Static method Public Method Creates New Business Object 20050309
9 DEQUEUE Static method Public Method Resets Lock (Generic) 20050309
10 ENQUEUE Static method Public Method Sets Lock (Generic) 20050309
11 EXISTS Static method Public Method Checks Existence of Business Object Via Business Key (Y/N) 20050309
12 FIND Static method Public Method Delivers Instances of Business Objects Using Business Key 20050309
13 FIND_BY_DETAIL Static method Public Method Delivers Instances of Business Objects Using Basic Data 20050309
14 FIND_BY_INTRENO Static method Public Method Delivers Instances of Business Objects Using INTRENO 20050309
15 FIND_BY_OBJNR Static method Public Method Delivers Instances of Business Objects Using OBJNR 20050309
16 IS_EXT_NUMBER_ASSIGNMENT Static method Public Method Is external number assignment active? 20050309
17 _FIND_BY_DETAIL Static method Private Method Delivers Instances of Business Objects Using Basic Data 20050309
Events
Class CF_RELM_NOTICE_ASSESSMENT has no event.
Types
Class CF_RELM_NOTICE_ASSESSMENT has no local type.
Method Signatures

Method CHECK_AUTHORITY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_ACTIVITY Call by reference Type reference (TYPE) RECA1_ACTIVITY RECA1_ACTIVITY-DISPLAY Aktivität 20050309
2 Importing ID_AUTHGRP Call by reference Type reference (TYPE) RECAAUTHGRP Berechtigungsgruppe 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method CHECK_KEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
2 Importing IF_BYPASSING_BUFFER Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Lesen von DB ohne Verwendung des Puffers 20050309
# Exception Resumable Description Created on
1 NOT_FOUND Nicht gefunden 20050309

Method CHECK_KEY_TO_CREATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
2 Importing IF_BYPASSING_BUFFER Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Lesen von DB ohne Verwendung des Puffers 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method CONVERT_BUSKEY_TO_IDENT_KEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ED_IDENT_KEY Call by reference Type reference (TYPE) RECAIDENTKEY Ident-Teil Schlüssel, z.B. "1000/123" 20050309
2 Importing ID_BUSKEY Call by reference Type reference (TYPE) RECA1_BUSKEY Objektschlüssel 20050309
# Exception Resumable Description Created on
1 UNDEFINED Externe Darstellung kann nicht ermittelt werden 20050309

Method CONVERT_BUSKEY_TO_KEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ED_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
2 Importing ID_BUSKEY Call by reference Type reference (TYPE) RECA1_BUSKEY Objektschlüssel 20050309
# Exception Resumable Description Created on
1 UNDEFINED Sematischer Schlüssel kann nicht ermittelt werden 20050309

Method CONVERT_KEY_TO_BUSKEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ED_BUSKEY Call by reference Type reference (TYPE) RECA1_BUSKEY Objektschlüssel 20050309
2 Exporting ED_BUSTYPE Call by reference Type reference (TYPE) RECA1_BUSTYPE Objekttyp 20050309
3 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
# Exception Resumable Description Created on
1 UNDEFINED Undefiniert 20050309

Method CONVERT_KEY_TO_IDENT_KEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ED_IDENT_KEY Call by reference Type reference (TYPE) RECAIDENTKEY Ident-Teil Schlüssel, z.B. "1000/123" 20050309
2 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
# Exception Resumable Description Created on
1 UNDEFINED BOR-Schlüssel kann nicht ermittelt werden 20050309

Method CREATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
2 Importing IF_AUTH_CHECK Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Default-Berechtigungsprüfungen durchführen? 20050309
3 Importing IF_ENQUEUE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Default-Sperren verwenden? 20050309
4 Returning RO_INSTANCE Value transfer Object reference (TYPE REF TO) IF_RELM_NOTICE_ASSESSMENT Einheitswertbescheid 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method DEQUEUE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_MODE Call by reference Type reference (TYPE) ENQMODE 'X' Sperrmodus 20050309
2 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
3 Importing ID_SCOPE Call by reference Type reference (TYPE) CHAR1 '2' Einstelliges Kennzeichen 20050309
4 Importing IF_COLLECT Call by reference Type reference (TYPE) DDENQCOLL ABAP_FALSE Flag, ob Sperren erst nur aufgesammelt werden sollen 20050309
5 Importing IF_SYNCHRON Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE TECH: Synchrones Entsperren? 20050309

Method DEQUEUE on class CF_RELM_NOTICE_ASSESSMENT has no exception.

Method ENQUEUE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_MODE Call by reference Type reference (TYPE) ENQMODE 'X' Sperrmodus 20050309
2 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
3 Importing ID_SCOPE Call by reference Type reference (TYPE) CHAR1 '2' Einstelliges Kennzeichen 20050309
4 Importing IF_COLLECT Call by reference Type reference (TYPE) DDENQCOLL ABAP_FALSE Flag, ob Sperren erst nur aufgesammelt werden sollen 20050309
5 Importing IF_WAIT Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method EXISTS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
2 Importing IF_BYPASSING_BUFFER Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Lesen von DB ohne Verwendung des Puffers 20050309
3 Returning RF_EXISTS Value transfer Type reference (TYPE) ABAP_BOOL Business-Objekt vorhanden 20050309

Method EXISTS on class CF_RELM_NOTICE_ASSESSMENT has no exception.

Method FIND Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_ACTIVITY Call by reference Type reference (TYPE) RECA1_ACTIVITY RECA1_ACTIVITY-DISPLAY Aktivität: Ändern/Anzeigen 20050309
2 Importing ID_NANO Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT-NANO Nummer des Einheitswertbescheids 20050309
3 Importing IF_AUTH_CHECK Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Default-Berechtigungsprüfungen durchführen? 20050309
4 Importing IF_ENQUEUE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Tech: Default-Sperren verwenden? 20050309
5 Importing IF_USE_ARCHIVE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Aus Archiv lesen, falls nicht in DB vorhanden? 20050309
6 Returning RO_INSTANCE Value transfer Object reference (TYPE REF TO) IF_RELM_NOTICE_ASSESSMENT Einheitswertbescheid 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method FIND_BY_DETAIL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_ACTIVITY Call by reference Type reference (TYPE) RECA1_ACTIVITY RECA1_ACTIVITY-DISPLAY Aktivität: Ändern/Anzeigen 20050309
2 Importing IF_ARCHIVED Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Archiv lesen 20050309
3 Importing IF_AUTH_CHECK Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Default-Berechtigungsprüfungen durchführen? 20050309
4 Importing IF_ENQUEUE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Tech: Default-Sperren verwenden? 20050309
5 Importing IS_DETAIL Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT Einhaitswertbescheid: Grunddaten 20050309
6 Returning RO_INSTANCE Value transfer Object reference (TYPE REF TO) IF_RELM_NOTICE_ASSESSMENT Einheitswertbescheid 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method FIND_BY_INTRENO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_ACTIVITY Call by reference Type reference (TYPE) RECA1_ACTIVITY RECA1_ACTIVITY-DISPLAY Aktivität: Ändern/Anzeigen 20050309
2 Importing ID_INTRENO Call by reference Type reference (TYPE) RECAINTRENO Interner Schlüssel des Immobilienobjekts 20050309
3 Importing IF_AUTH_CHECK Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Default-Berechtigungsprüfungen durchführen? 20050309
4 Importing IF_ENQUEUE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Tech: Default-Sperren verwenden? 20050309
5 Importing IF_USE_ARCHIVE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Aus Archiv lesen, falls nicht in DB vorhanden? 20050309
6 Returning RO_INSTANCE Value transfer Object reference (TYPE REF TO) IF_RELM_NOTICE_ASSESSMENT Einheitswertbescheid 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method FIND_BY_OBJNR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_ACTIVITY Call by reference Type reference (TYPE) RECA1_ACTIVITY RECA1_ACTIVITY-DISPLAY Aktivität: Ändern/Anzeigen 20050309
2 Importing ID_OBJNR Call by reference Type reference (TYPE) RECAOBJNR Objektnummer 20050309
3 Importing IF_AUTH_CHECK Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE Tech: Default-Berechtigungsprüfungen durchführen? 20050309
4 Importing IF_ENQUEUE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Tech: Default-Sperren verwenden? 20050309
5 Importing IF_USE_ARCHIVE Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE Aus Archiv lesen, falls nicht in DB vorhanden? 20050309
6 Returning RO_INSTANCE Value transfer Object reference (TYPE REF TO) IF_RELM_NOTICE_ASSESSMENT Einheitswertbescheid 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309

Method IS_EXT_NUMBER_ASSIGNMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RF_EXTERNAL Value transfer Type reference (TYPE) ABAP_BOOL Externe Nummernvergabe? 20050309
# Exception Resumable Description Created on
1 NOT_FOUND Nummernkreis nicht gefunden 20050309

Method _FIND_BY_DETAIL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_ACTIVITY Call by reference Type reference (TYPE) RECA1_ACTIVITY Aktivität: Ändern/Anzeigen 20050309
2 Importing IF_ARCHIVED Call by reference Type reference (TYPE) ABAP_BOOL Wird das Objekt aus dem Archiv gelesen? 20050309
3 Importing IF_AUTH_CHECK Call by reference Type reference (TYPE) ABAP_BOOL Tech: Default-Berechtigungsprüfungen durchführen? 20050309
4 Importing IF_ENQUEUE Call by reference Type reference (TYPE) ABAP_BOOL Tech: Default-Sperren verwenden? 20050309
5 Importing IS_DETAIL Call by reference Type reference (TYPE) RELM_NOTICE_ASSESSMENT Einheitswertbescheid: Grunddaten 20050309
6 Returning RO_INSTANCE Value transfer Object reference (TYPE REF TO) IF_RELM_NOTICE_ASSESSMENT Einheitswertbescheid 20050309
# Exception Resumable Description Created on
1 ERROR Fehler 20050309
History
Last changed by/on SAP  20100310 
SAP Release Created in 600