SAP ABAP Class /PLMU/CL_FRW_W_MODEL_POOL (Wire Model Pool)
Hierarchy
☛
SAP_BS_FND (Software Component) SAP Business Suite Foundation
⤷
CA-EPT-SPI-FSI (Application Component) FPM SPI Integration
⤷
/PLMU/UI_FRW_SERVICES (Package) UI Framework: Services

⤷

⤷

Properties
Class | /PLMU/CL_FRW_W_MODEL_POOL | |
Short Description | Wire Model Pool | |
Super Class | ||
Instantiability of a Class | 0 | Private |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | /PLMU/UI_FRW_SERVICES | UI Framework: Services |
Created | 20110504 | SAP |
Last change | 20130531 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class /PLMU/CL_FRW_W_MODEL_POOL has no interface implemented.
Friends
Class /PLMU/CL_FRW_W_MODEL_POOL has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Static Attribute | Private | Object reference (TYPE REF TO) | /PLMU/CL_FRW_W_MODEL_POOL | 20110504 | |||
2 | ![]() |
Instance attribute | Private | Type reference (TYPE) | GTY_T_REGISTER | 20110504 | |||
3 | ![]() |
Instance attribute | Private | Type reference (TYPE) | GTY_T_TABED_WIRE_MODEL | 20110504 | |||
4 | ![]() |
Instance attribute | Private | Type reference (TYPE) | GTY_T_MODEL_POOL | 20110504 | |||
5 | ![]() |
Instance attribute | Private | Type reference (TYPE) | BOOLE_D | 20110504 |
Methods
Events
Class /PLMU/CL_FRW_W_MODEL_POOL has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | GTY_S_MODEL_POOL | Private | See coding | 20110505 | BEGIN OF gty_s_model_pool,
uibb_instance_key TYPE fpm_s_uibb_instance_key,
wire_model TYPE REF TO /plmu/cl_frw_w_model,
END OF gty_s_model_pool
|
||
2 | GTY_S_REGISTER | Private | See coding | 20110504 | BEGIN OF gty_s_register,
abbid TYPE /plmb/spi_abbid,
node_name TYPE /plmb/spi_node_name,
container TYPE REF TO /plmu/cl_frw_w_model_container,
group_container TYPE REF TO /plmu/cl_frw_w_model_container,
END OF gty_s_register
|
||
3 | GTY_T_MODEL_POOL | Private | See coding | 20110505 | gty_t_model_pool TYPE SORTED TABLE OF gty_s_model_pool
WITH UNIQUE KEY uibb_instance_key
WITH UNIQUE SORTED KEY wire_model COMPONENTS wire_model
|
||
4 | GTY_T_NODE_NAME | Public | See coding | 20110504 | gty_t_node_name TYPE SORTED TABLE OF /plmb/spi_node_name WITH UNIQUE
KEY table_line
|
||
5 | GTY_T_REGISTER | Private | See coding | 20110504 | gty_t_register TYPE SORTED TABLE OF gty_s_register
WITH UNIQUE KEY abbid node_name
|
||
6 | GTY_T_TABED_WIRE_MODEL | Private | See coding | 20110504 | gty_t_tabed_wire_model TYPE STANDARD TABLE OF
REF TO /plmu/cl_frw_w_model WITH DEFAULT KEY
|
Method Signatures
Method CONSTRUCTOR Signature
Method CONSTRUCTOR on class /PLMU/CL_FRW_W_MODEL_POOL has no parameter.
Method CONSTRUCTOR on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method FILL_CONTAINER_WITH_MODEL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_WIRE_MODEL | Call by reference | Object reference (TYPE REF TO) | /PLMU/CL_FRW_W_MODEL | Wire Model | 20111213 |
Method FILL_CONTAINER_WITH_MODEL on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method GET_INSTANCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RO_INSTANCE | Value transfer | Object reference (TYPE REF TO) | /PLMU/CL_FRW_W_MODEL_POOL | 20110504 |
Method GET_INSTANCE on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method GET_NODE_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_DATA | Call by reference | Type reference (TYPE) | INDEX TABLE | 20110504 | |||
2 | ![]() |
IV_ABBID | Call by reference | Type reference (TYPE) | /PLMB/SPI_ABBID | Application Building Block ID | 20110504 | ||
3 | ![]() |
IV_NODE_NAME | Call by reference | Type reference (TYPE) | /PLMB/SPI_NODE_NAME | Node Name | 20110504 | ||
4 | ![]() |
IV_PORT_TYPE | Call by reference | Type reference (TYPE) | FPM_MODEL_PORT_TYPE | FPM Wire Model: Port Type | 20110504 |
Method GET_NODE_DATA on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method GET_NODE_DATA_GROUPED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_DATA | Call by reference | Type reference (TYPE) | INDEX TABLE | 20110504 | |||
2 | ![]() |
IV_ABBID | Call by reference | Type reference (TYPE) | /PLMB/SPI_ABBID | Application Building Block ID | 20110504 | ||
3 | ![]() |
IV_NODE_NAME | Call by reference | Type reference (TYPE) | /PLMB/SPI_NODE_NAME | Node Name | 20110504 | ||
4 | ![]() |
IV_PORT_TYPE | Call by reference | Type reference (TYPE) | FPM_MODEL_PORT_TYPE | FPM Wire Model: Port Type | 20110504 |
Method GET_NODE_DATA_GROUPED on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method GET_WIRE_MODEL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_UIBB_INSTANCE_KEY | Call by reference | Type reference (TYPE) | FPM_S_UIBB_INSTANCE_KEY | 20110504 | |||
2 | ![]() |
RO_WIRE_MODEL | Value transfer | Object reference (TYPE REF TO) | /PLMU/IF_FRW_W_MODEL_ACCESS | 20110504 |
Method GET_WIRE_MODEL on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method GROUP_NODES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IT_NODE_GROUP | Call by reference | Type reference (TYPE) | /PLMU/T_FRW_NODE_GROUP | UI Framework - Node Group | 20110504 |
Method GROUP_NODES on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method HNDL_AFTER_AFTER_PBO Signature
Method HNDL_AFTER_AFTER_PBO on class /PLMU/CL_FRW_W_MODEL_POOL has no parameter.
Method HNDL_AFTER_AFTER_PBO on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method HNDL_AFTER_MODEL_CREATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_WIRE_MODEL | Call by reference | Attribute reference (LIKE) | 20110505 |
Method HNDL_AFTER_MODEL_CREATION on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method HNDL_AFTER_MODEL_REINIT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_WIRE_MODEL | Call by reference | Attribute reference (LIKE) | 20111213 |
Method HNDL_AFTER_MODEL_REINIT on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method HNDL_BEFORE_AFTER_PBO Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IR_UIBBS_TABLE | Value transfer | Attribute reference (LIKE) | 20110504 |
Method HNDL_BEFORE_AFTER_PBO on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method HNDL_BEFORE_MODEL_REINIT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_WIRE_MODEL | Call by reference | Attribute reference (LIKE) | 20111213 |
Method HNDL_BEFORE_MODEL_REINIT on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method HNDL_OUTPORT_DATA_TABED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_WIRE_MODEL | Value transfer | Attribute reference (LIKE) | 20110504 |
Method HNDL_OUTPORT_DATA_TABED on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
Method REMOVE_MODEL_FROM_CONTAINER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_WIRE_MODEL | Call by reference | Object reference (TYPE REF TO) | /PLMU/CL_FRW_W_MODEL | Wire Model | 20111213 |
Method REMOVE_MODEL_FROM_CONTAINER on class /PLMU/CL_FRW_W_MODEL_POOL has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 731 |