SAP ABAP Class /BOFU/CL_PPFOC_BCS_ARCH (Archiving Service Class for PPF OM - BCS)
Hierarchy
SAP_BS_FND (Software Component) SAP Business Suite Foundation
   CA-EPT-BRC-PPF (Application Component) Post Processing Framework Adapter
     /BOFU/PPF_ADAPTER_CONTENT_DO (Package) PPF Adapter for BOPF: Output History Content: Business Obj
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  /BOFU/CL_ARCH_GENER1 Generic Archiving Facade: Writes combined data 20100806
Properties
Class /BOFU/CL_PPFOC_BCS_ARCH  
Short Description Archiving Service Class for PPF OM - BCS    
Super Class /BOFU/CL_ARCH_GENER1 Generic Archiving Facade: Writes combined data 
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package /BOFU/PPF_ADAPTER_CONTENT_DO   PPF Adapter for BOPF: Output History Content: Business Obj 
Created 20100806   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class /BOFU/CL_PPFOC_BCS_ARCH has no forward declaration.
Interfaces
Class /BOFU/CL_PPFOC_BCS_ARCH has no interface implemented.
Friends
Class /BOFU/CL_PPFOC_BCS_ARCH has no friend class.
Attributes
Class /BOFU/CL_PPFOC_BCS_ARCH has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CONVRT_ATTCH_NODE_2_WRI_STRUCT Instance method Private Method Convert Attachment Node to Archiving Write Structure 20110106
2 CONVRT_ATTCH_WRI_STRUCT_2_NODE Instance method Private Method Convert Data from Write Structure to the Node for Reading 20110106
Events
Class /BOFU/CL_PPFOC_BCS_ARCH has no event.
Types
Class /BOFU/CL_PPFOC_BCS_ARCH has no local type.
Method Signatures

Method CONVRT_ATTCH_NODE_2_WRI_STRUCT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_WRITE_STRUCT_DATA Call by reference Type reference (TYPE) STANDARD TABLE 20110106
2 Importing IS_NODE_DATA_DATA Call by reference Type reference (TYPE) TS_NODE_AND_DATA 20110106
3 Importing IT_NODE_DATA Call by reference Type reference (TYPE) INDEX TABLE Attachments 20110106

Method CONVRT_ATTCH_NODE_2_WRI_STRUCT on class /BOFU/CL_PPFOC_BCS_ARCH has no exception.

Method CONVRT_ATTCH_WRI_STRUCT_2_NODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_NODE_DATA Call by reference Type reference (TYPE) INDEX TABLE 20110106
2 Importing IS_NODE_DATA_DATA Call by reference Type reference (TYPE) TS_NODE_AND_DATA 20110106
3 Importing IT_WRITE_STRUCT_DATA Call by reference Type reference (TYPE) STANDARD TABLE 20110106

Method CONVRT_ATTCH_WRI_STRUCT_2_NODE on class /BOFU/CL_PPFOC_BCS_ARCH has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in 702