Hierarchy
⤷ AP-RC-BOF-CFN (Application Component) Business Object Processing Framework Configuration
⤷ /BOBF/TOOLS (Package) Business Object Processing Framework Tools
Meta Relationship - Using
Properties
Class | /BOBF/CL_TOOL_AUNIT_FRW | |
Short Description | ABAP Unit framework class | |
Super Class | CL_AUNIT_ASSERT | ABAP Unit: Assertions (see Longtext) |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | /BOBF/TOOLS | Business Object Processing Framework Tools |
Created | 20081213 | SAP |
Last change | 20130531 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ABAP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | /BOBF/IF_FRW_ADDON | Interface for initialization of runtime addons | 20081213 | ||
2 | /BOBF/IF_FRW_CHECK | Interface to perform a Check | 20081213 | ||
3 | /BOBF/IF_FRW_MODIFY | Interface to Change Data | 20081213 | ||
4 | /BOBF/IF_FRW_QUERY | Interface to query implementation | 20081213 | ||
5 | /BOBF/IF_FRW_READ | Interface to Read Data | 20081213 | ||
6 | /BOBF/IF_TOOL_AUNIT_FRW | Access to testdata parameters for modification of BO nodes | 20081213 | ||
7 | /BOBF/IF_TOOL_AUNIT_READ | Read interface for prepare methods | 20081213 | ||
8 | /BOBF/IF_TOOL_AUNIT_TESTDATA | Access to testdata for modification before test execution | 20081213 |
Friends
Class /BOBF/CL_TOOL_AUNIT_FRW has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | CV_USE_ANY_BUFFER | Constant | Protected | Type reference (TYPE) | CHAR1 | 2 | Single-Character Flag | 20081213 | |
2 | CV_USE_OWN_BUFFER | Constant | Protected | Type reference (TYPE) | CHAR1 | 1 | Single-Character Flag | 20081213 | |
3 | GC_PAR_ACTION_KEY | Constant | Private | Type reference (TYPE) | ETP_NAME | 'ACTION_KEY' | Name of a Parameter or Command Interface | 20081213 | |
4 | GC_PAR_ACTION_PARAMETERS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'ACTION_PARAMETERS' | Name of a Parameter or Command Interface | 20081213 | |
5 | GC_PAR_ATTRIBUTES | Constant | Private | Type reference (TYPE) | ETP_NAME | 'ATTRIBUTES' | Name of a Parameter or Command Interface | 20081213 | |
6 | GC_PAR_AUTHORIZATION_CONTEXT | Constant | Private | Type reference (TYPE) | ETP_NAME | 'AUTHORIZATION_CONTEXT' | Name of a Parameter or Command Interface | 20081213 | |
7 | GC_PAR_BO_CONTAINER | Constant | Private | Type reference (TYPE) | ETP_NAME | 'BO_CONTAINER' | Name of a Parameter or Command Interface | 20081213 | |
8 | GC_PAR_BO_VARIANT_BEFORE | Constant | Private | Type reference (TYPE) | ETP_NAME | 'BO_VARIANT_BEFORE' | Name of a Parameter or Command Interface | 20081213 | |
9 | GC_PAR_BO_VARIANT_CURRENT | Constant | Private | Type reference (TYPE) | ETP_NAME | 'BO_VARIANT_CURRENT' | Name of a Parameter or Command Interface | 20081213 | |
10 | GC_PAR_DELETED_NODES | Constant | Private | Type reference (TYPE) | ETP_NAME | 'DELETED_NODES' | Name of a Parameter or Command Interface | 20081213 | |
11 | GC_PAR_DO_LCP_SIMULATIONS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'DO_LCP_SIMULATIONS' | Name of a Parameter or Command Interface | 20081213 | |
12 | GC_PAR_EXECUTION_TIME | Constant | Private | Type reference (TYPE) | ETP_NAME | 'EXECUTION_TIME' | Name of a Parameter or Command Interface | 20081213 | |
13 | GC_PAR_FILTERED_ATTRIBUTES | Constant | Private | Type reference (TYPE) | ETP_NAME | 'FILTERED_ATTRIBUTES' | Name of a Parameter or Command Interface | 20081213 | |
14 | GC_PAR_FILTER_KEYS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'FILTER_KEYS' | Name of a Parameter or Command Interface | 20081213 | |
15 | GC_PAR_FINALIZE_TIMESTAMP | Constant | Private | Type reference (TYPE) | ETP_NAME | 'FINALIZE_TIMESTAMP' | Name of a Parameter or Command Interface | 20081213 | |
16 | GC_PAR_KEYS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'KEYS' | Name of a Parameter or Command Interface | 20081213 | |
17 | GC_PAR_KEYS_1 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'KEYS_1' | Name of a Parameter or Command Interface | 20081213 | |
18 | GC_PAR_KEYS_2 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'KEYS_2' | Name of a Parameter or Command Interface | 20081213 | |
19 | GC_PAR_KEYS_3 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'KEYS_3' | Name of a Parameter or Command Interface | 20081213 | |
20 | GC_PAR_LCP_SIMULATIONS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'LCP_SIMULATIONS' | Name of a Parameter or Command Interface | 20081213 | |
21 | GC_PAR_LCP_SIMULATION_CONF | Constant | Private | Type reference (TYPE) | ETP_NAME | 'LCP_SIMULATION_CONFIGURATION' | Name of a Parameter or Command Interface | 20081213 | |
22 | GC_PAR_MESSAGES_EXPECTED | Constant | Public | Type reference (TYPE) | ETP_NAME | 'MESSAGES_EXPECTED' | Name of a Parameter or Command Interface | 20081213 | |
23 | GC_PAR_MESSAGE_CHECK_CLASS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'MESSAGE_CHECK_CLASS' | Name of a Parameter or Command Interface | 20081213 | |
24 | GC_PAR_MOCK_CONF | Constant | Private | Type reference (TYPE) | ETP_NAME | '_MOCK_CONF' | Name of a Parameter or Command Interface | 20090316 | |
25 | GC_PAR_MODEL | Constant | Private | Type reference (TYPE) | ETP_NAME | 'MODEL' | Name of a Parameter or Command Interface | 20081213 | |
26 | GC_PAR_NODECAT | Constant | Private | Type reference (TYPE) | ETP_NAME | 'NODECAT' | Name of a Parameter or Command Interface | 20081213 | |
27 | GC_PAR_PARAMETERS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'PARAMETERS' | Name of a Parameter or Command Interface | 20081213 | |
28 | GC_PAR_PARAMETERS_1 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'PARAMETERS_1' | Name of a Parameter or Command Interface | 20081213 | |
29 | GC_PAR_PARAMETERS_2 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'PARAMETERS_2' | Name of a Parameter or Command Interface | 20081213 | |
30 | GC_PAR_PREPARE_CLASS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'PREPARE_CLASS' | Name of a Parameter or Command Interface | 20081213 | |
31 | GC_PAR_QUERY_INFO | Constant | Private | Type reference (TYPE) | ETP_NAME | 'QUERY_INFO' | Name of a Parameter or Command Interface | 20081213 | |
32 | GC_PAR_QUERY_OPTIONS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'QUERY_OPTIONS' | Name of a Parameter or Command Interface | 20081213 | |
33 | GC_PAR_REFERENCE_NODES | Constant | Private | Type reference (TYPE) | ETP_NAME | 'REFERENCE_NODES' | Name of a Parameter or Command Interface | 20081213 | |
34 | GC_PAR_REFERENCE_NODES_1 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'REFERENCE_NODES_1' | Name of a Parameter or Command Interface | 20081213 | |
35 | GC_PAR_REFERENCE_NODES_2 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'REFERENCE_NODES_2' | Name of a Parameter or Command Interface | 20081213 | |
36 | GC_PAR_RESULT | Constant | Private | Type reference (TYPE) | ETP_NAME | 'RESULT' | Name of a Parameter or Command Interface | 20081213 | |
37 | GC_PAR_RESULT_1 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'RESULT_1' | Name of a Parameter or Command Interface | 20081213 | |
38 | GC_PAR_RESULT_2 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'RESULT_2' | Name of a Parameter or Command Interface | 20081213 | |
39 | GC_PAR_RESULT_3 | Constant | Private | Type reference (TYPE) | ETP_NAME | 'RESULT_3' | Name of a Parameter or Command Interface | 20081213 | |
40 | GC_PAR_SELECTION_PARAMETERS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'SELECTION_PARAMETERS' | Name of a Parameter or Command Interface | 20081213 | |
41 | GC_PAR_SOURCE_STATUSES | Constant | Private | Type reference (TYPE) | ETP_NAME | 'SOURCE_STATUSES' | Name of a Parameter or Command Interface | 20081213 | |
42 | GC_PAR_TARGET_STATUS | Constant | Private | Type reference (TYPE) | ETP_NAME | 'TARGET_STATUS' | Name of a Parameter or Command Interface | 20081213 | |
43 | GC_PAR_TEST_PAR | Constant | Private | Type reference (TYPE) | ETP_NAME | 'TEST_PAR' | Name of a Parameter or Command Interface | 20081213 | |
44 | GC_VAR_ECATTDEFAULT | Constant | Private | Type reference (TYPE) | ETVAR_ID | 'ECATTDEFAULT' | Variant name | 20081213 | |
45 | GO_BUFFER | Static Attribute | Private | Object reference (TYPE REF TO) | /BOBF/IF_FRW_BUFFER | Interface to the Data Layer | 20081213 | ||
46 | GT_ACTIVATED_BO | Static Attribute | Private | Type reference (TYPE) | /BOBF/T_FRW_KEY2 | Key table | 20081213 | ||
47 | GT_STATUS | Static Attribute | Private | Type reference (TYPE) | TT_STATUS | 20081213 | |||
48 | GV_BO_KEY | Static Attribute | Private | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
49 | GV_INSTANCE_AMOUNT | Static Attribute | Private | Type reference (TYPE) | I | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
50 | GV_USE_OWN_BUFFER | Static Attribute | Private | Type reference (TYPE) | CHAR1 | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
51 | MO_BOPF | Instance attribute | Private | Object reference (TYPE REF TO) | /BOBF/IF_FRW_SERVICE_LAYER | Interface for the Service Layer | 20081213 | ||
52 | MO_BUFFER | Instance attribute | Private | Object reference (TYPE REF TO) | /BOBF/IF_FRW_BUFFER | Interface to the Data Layer | 20081213 | ||
53 | MO_CHANGE | Instance attribute | Private | Object reference (TYPE REF TO) | /BOBF/IF_FRW_CHANGE | current change object | 20081213 | ||
54 | MO_CONF | Instance attribute | Private | Object reference (TYPE REF TO) | /BOBF/IF_FRW_CONFIGURATION | Interface for Configuration | 20081213 | ||
55 | MO_LOCAL_CHANGE | Instance attribute | Private | Object reference (TYPE REF TO) | /BOBF/IF_FRW_CHANGE | local change object | 20081213 | ||
56 | MO_STATUS | Instance attribute | Private | Object reference (TYPE REF TO) | /BOBF/IF_FRW_STATUS | Interface to Status & Action Management | 20081213 | ||
57 | MS_CTX_ACT | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
58 | MS_CTX_ASSOC | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
59 | MS_CTX_DET | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
60 | MS_CTX_QUERY | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
61 | MS_CTX_STA_DERIV | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
62 | MS_CTX_VAL | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
63 | MS_CTX_VSET | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
64 | MT_BO_CONTAINER | Instance attribute | Private | Type reference (TYPE) | /BOBF/T_TOOL_TDC_CONTENT | Test data container content | 20081213 | ||
65 | MT_CHANGE_STACK | Instance attribute | Private | Type reference (TYPE) | TY_T_FRW_CHANGE | stack of change objects | 20081213 | ||
66 | MT_MODIFICATION | Instance attribute | Private | Type reference (TYPE) | /BOBF/T_FRW_MODIFICATION | Accumulated changes (for checking) | 20081213 | ||
67 | MT_TESTDATA_CONTAINER | Instance attribute | Private | Type reference (TYPE) | /BOBF/T_TOOL_TDC_CONTENT | Test Data Container content | 20081213 | ||
68 | MT_TESTDATA_CONTAINER_REPLACED | Instance attribute | Private | Type reference (TYPE) | /BOBF/T_TOOL_TDC_CONTENT | Test data container content | 20081213 | ||
69 | MV_ASSOC_KEY | Instance attribute | Private | Type reference (TYPE) | /BOBF/OBM_ASSOC_KEY | Associationkey (to prevent recursive association calls) | 20081213 | ||
70 | MV_CHANGE_STACK_LEVEL | Instance attribute | Private | Type reference (TYPE) | I | current change stack level | 20081213 | ||
71 | MV_CHECK_BO_ESR_AVAILABILITY | Instance attribute | Private | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
72 | MV_CHECK_EXECUTION | Instance attribute | Private | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
73 | MV_LCP_FACTORY_CLASS_NAME | Instance attribute | Private | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
74 | MV_MODIFY_BEFORE | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
75 | MV_PROVIDER_CONTEXT_CLASS_NAME | Instance attribute | Private | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
76 | MV_RETRIEVE_BEFORE | Instance attribute | Private | Type reference (TYPE) | BOOLE_D | Only for implemented associations called with before = 'X'' | 20081213 | ||
77 | MV_TESTDATA_CONTAINER_NAME | Instance attribute | Private | Type reference (TYPE) | ETOBJ_NAME | eCATT Object | 20081213 | ||
78 | MV_VARIANT | Instance attribute | Private | Attribute reference (LIKE) | 20081213 | ||||
79 | MV_WITHIN_SAM_CALL | Instance attribute | Private | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 |
Methods
Events
Class /BOBF/CL_TOOL_AUNIT_FRW has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | TT_BO_CONTENT_KEY | Private | See coding | 20081213 | tt_bo_content_key TYPE STANDARD TABLE OF ty_bo_content_key
|
||
2 | TT_STATUS | Private | See coding | 20081213 | tt_status TYPE STANDARD TABLE OF ty_status
|
||
3 | TY_AUNIT_MESSAGE | Private | See coding | 20081213 | BEGIN OF ty_aunit_message,
message TYPE string,
level TYPE aunit_level,
quit TYPE aunit_flowctrl,
END OF ty_aunit_message
|
||
4 | TY_BO_CONTENT_KEY | Private | See coding | 20081213 | BEGIN OF ty_bo_content_key,
bo_key TYPE /BOBF/OBM_BO_KEY,
do_key TYPE /BOBF/OBM_BO_KEY,
content_key TYPE /BOBF/CONF_KEY,
END OF ty_bo_content_key
|
||
5 | TY_STATUS | Private | See coding | 20081213 | BEGIN OF ty_status,
bo_key TYPE /BOBF/OBM_BO_KEY,
status_ref TYPE REF TO /BOBF/IF_FRW_STATUS,
END OF ty_status
|
||
6 | TY_T_FRW_CHANGE | Private | See coding | 20081213 | ty_t_frw_change TYPE STANDARD TABLE OF REF TO /BOBF/IF_FRW_CHANGE
|
Method Signatures
Method BUILD_META_MODEL_TABLE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_META_MODEL | Call by reference | Type reference (TYPE) | /BOBF/T_TOOL_META_MODEL | Model information for testdata container | 20081213 |
Method BUILD_META_MODEL_TABLE on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_ACTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_ACT_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
2 | Importing | IV_ACT_KEY | Call by reference | Type reference (TYPE) | /BOBF/ACT_KEY | Action | 20081213 | ||
3 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
4 | Importing | IV_CHECK_ANY_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: is any interface method tested | 20090730 | ||
5 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
6 | Importing | IV_CHECK_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: are all interface methods tested | 20081213 | ||
7 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | *deprecated! do not use!* | 20081213 | ||
8 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
9 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Use BO specific buffer instead of generic AUnit FRW buffer | 20081213 | ||
10 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_ACTION on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_ASSOCIATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_ASSOC_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
2 | Importing | IV_ASSOC_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_ASSOC_KEY | Association | 20081213 | ||
3 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
4 | Importing | IV_CHECK_ANY_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: is any interface method tested | 20090730 | ||
5 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
6 | Importing | IV_CHECK_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: are all interface methods tested | 20081213 | ||
7 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: do parameter names match node names | 20081213 | ||
8 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
9 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Use BO specific buffer instead of generic AUnit FRW buffer | 20081213 | ||
10 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_ASSOCIATION on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_CODE_VALUE_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
2 | Importing | IV_CHECK_ANY_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: is any interface method tested | 20090730 | ||
3 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
4 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
5 | Importing | IV_CODE_VALUE_SET_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Variant name | 20081213 | ||
6 | Importing | IV_CODE_VALUE_SET_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_VALUE_SET_KEY | Object Type Name | 20081213 | ||
7 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Determination | 20081213 | ||
8 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
9 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_CODE_VALUE_SET on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_DETERMINATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
2 | Importing | IV_CHECK_ANY_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: is any interface method tested | 20090730 | ||
3 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
4 | Importing | IV_CHECK_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: are all interface methods tested | 20081213 | ||
5 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: do parameter names match node names | 20081213 | ||
6 | Importing | IV_DET_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
7 | Importing | IV_DET_KEY | Call by reference | Type reference (TYPE) | /BOBF/DET_KEY | Determination | 20081213 | ||
8 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
9 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Use BO specific buffer instead of generic AUnit FRW buffer | 20081213 | ||
10 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_DETERMINATION on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_ID_VALUE_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
2 | Importing | IV_CHECK_ANY_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: is any interface method tested | 20090730 | ||
3 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
4 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
5 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Determination | 20081213 | ||
6 | Importing | IV_ID_VALUE_SET_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Variant name | 20081213 | ||
7 | Importing | IV_ID_VALUE_SET_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_VALUE_SET_KEY | Object Type Name | 20081213 | ||
8 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
9 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_ID_VALUE_SET on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_MODIFICATIONS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IT_META_MODEL | Call by reference | Type reference (TYPE) | /BOBF/T_TOOL_META_MODEL | Model information for testdata container | 20081213 | ||
2 | Importing | IV_CLASS_NAME | Call by reference | Type reference (TYPE) | STRING | Object Type Name | 20081213 | ||
3 | Importing | IV_TESTDATA_CONTAINER_NAME | Call by reference | Type reference (TYPE) | ETOBJ_NAME | 20081213 |
Method CHECK_MODIFICATIONS on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_QUERY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
2 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
3 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
4 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
5 | Importing | IV_QUERY_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
6 | Importing | IV_QUERY_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_QUERY_KEY | Query | 20081213 | ||
7 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
8 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_QUERY on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_STATUS_DERIVATOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
2 | Importing | IV_STA_DERIV_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
3 | Importing | IV_STA_DERIV_KEY | Call by reference | Type reference (TYPE) | /BOBF/STA_DERIVATOR_KEY | Determination | 20081213 | ||
4 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_STATUS_DERIVATOR on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CHECK_VALIDATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
2 | Importing | IV_CHECK_ANY_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: is any interface method tested | 20090730 | ||
3 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
4 | Importing | IV_CHECK_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: are all interface methods tested | 20081213 | ||
5 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | Activate check: do parameter names match node names | 20081213 | ||
6 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
7 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Use BO specific buffer instead of generic AUnit FRW buffer | 20081213 | ||
8 | Importing | IV_VAL_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
9 | Importing | IV_VAL_KEY | Call by reference | Type reference (TYPE) | /BOBF/VAL_KEY | Determination | 20081213 | ||
10 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method CHECK_VALIDATION on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CLEAR_CHANGE_STACK Signature
Method CLEAR_CHANGE_STACK on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method CLEAR_CHANGE_STACK on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CLEAR_INT_ACCESS_DATA Signature
Method CLEAR_INT_ACCESS_DATA on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method CLEAR_INT_ACCESS_DATA on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method COMPARE_KEY_TAB Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IT_KEY_1 | Call by reference | Type reference (TYPE) | /BOBF/T_FRW_KEY | Key Table | 20081213 | ||
2 | Importing | IT_KEY_2 | Call by reference | Type reference (TYPE) | /BOBF/T_FRW_KEY | 20081213 | |||
3 | Importing | IV_MESSAGE | Call by reference | Type reference (TYPE) | CSEQUENCE | 20081213 |
Method COMPARE_KEY_TAB on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_TRUE | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | |
2 | Importing | IV_CHECK_EXECUTION | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_TRUE | Activate check: are all interface methods tested | 20081213 | |
3 | Importing | IV_CHECK_NODE_NAMES | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_TRUE | Activate check: do parameter names match node names | 20081213 | |
4 | Importing | IV_LCP_FACTORY_CLASS_NAME | Call by reference | Type reference (TYPE) | SEOCLSNAME | LCP Factory class. IMPORTANT: Use only for non-ESA BOs! | 20081213 | ||
5 | Importing | IV_PROVIDER_CONTEXT_CLASS_NAME | Call by reference | Type reference (TYPE) | SEOCLSNAME | Provider Context class. IMPORTANT: Use only for non-ESA BOs! | 20081213 | ||
6 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Use BO specific buffer instead of generic AUnit FRW buffer | 20081213 |
Method CONSTRUCTOR on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CONVERT_ALTERN_KEY Signature
Method CONVERT_ALTERN_KEY on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method CONVERT_ALTERN_KEY on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method CREATE Signature
Method CREATE on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method CREATE on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method DELETE Signature
Method DELETE on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method DELETE on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method DO_ACTION Signature
Method DO_ACTION on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method DO_ACTION on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method END_MODIFY Signature
Method END_MODIFY on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method END_MODIFY on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method ENTER_CHANGE_STACK Signature
Method ENTER_CHANGE_STACK on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method ENTER_CHANGE_STACK on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method FILL_CREATE_HANDLE_TAB Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_CREATE_HANDLE_LINK | Call by reference | Type reference (TYPE) | /BOBF/T_TOOL_CR_HANDLE_LINK | Create handle link | 20081213 | ||
2 | Importing | IT_META_MODEL | Call by reference | Type reference (TYPE) | /BOBF/T_TOOL_META_MODEL | Model information for testdata container | 20081213 | ||
3 | Importing | IV_TESTDATA_CONTAINER_NAME | Call by reference | Type reference (TYPE) | ETP_NAME | Name of a Parameter or Command Interface | 20081213 |
Method FILL_CREATE_HANDLE_TAB on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method GET_BUFFER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EO_BUFFER | Call by reference | Object reference (TYPE REF TO) | /BOBF/IF_FRW_BUFFER | Interface to the Data Layer | 20081213 |
Method GET_BUFFER on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method GET_DATA_DESCR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EO_DATADESCR | Call by reference | Object reference (TYPE REF TO) | CL_ABAP_DATADESCR | Runtime Type Services | 20081213 | ||
2 | Importing | IT_COMPONENT | Call by reference | Type reference (TYPE) | ABAP_COMPONENT_TAB | 20081213 | |||
3 | Importing | IV_NAME | Call by reference | Type reference (TYPE) | /BOBF/OBM_NAME | Name | 20081213 |
Method GET_DATA_DESCR on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method GET_ROOT_KEY Signature
Method GET_ROOT_KEY on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method GET_ROOT_KEY on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method GET_SUBNODE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CT_SUBNODE_KEY | Call by reference | Type reference (TYPE) | /BOBF/T_CONFRO_NODE_KEY | Key Table | 20081213 | ||
2 | Importing | IT_COMP_CONF | Call by reference | Type reference (TYPE) | /BOBF/T_CONFRO_ASSOC2 | Configuration: Associations | 20081213 | ||
3 | Importing | IV_NODE_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_NODE_KEY | Node | 20081213 |
Method GET_SUBNODE on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method GET_SUBNODE_INSTANCES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CT_HOST_NODE | Call by reference | Type reference (TYPE) | /BOBF/T_FRW_NODE | Node Table | 20081213 | ||
2 | Exporting | EO_MESSAGE | Call by reference | Object reference (TYPE REF TO) | /BOBF/IF_FRW_MESSAGE | Interface of Message Object | 20081213 | ||
3 | Importing | IT_KEY | Call by reference | Type reference (TYPE) | /BOBF/T_FRW_KEY | Key Table | 20081213 | ||
4 | Importing | IV_NODE_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_NODE_KEY | Node | 20081213 |
Method GET_SUBNODE_INSTANCES on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method GET_TESTABLE_CONTENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_BO_CONTENT_KEY | Call by reference | Type reference (TYPE) | TT_BO_CONTENT_KEY | 20081213 | |||
2 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 | ||
3 | Importing | IV_CONTENT_CAT | Call by reference | Type reference (TYPE) | /BOBF/OBM_CONTENT_CAT | Entity Category | 20081213 | ||
4 | Importing | IV_CONTENT_CLASS | Call by reference | Type reference (TYPE) | SEOCLSNAME | Object Type Name | 20081213 | ||
5 | Importing | IV_CONTENT_KEY | Call by reference | Type reference (TYPE) | /BOBF/CONF_KEY | NodeID | 20081213 | ||
6 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_BO_KEY | Business Object | 20081213 |
Method GET_TESTABLE_CONTENT on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method GET_UNEQUAL_FIELDS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_FIELDNAME | Call by reference | Type reference (TYPE) | /BOBF/T_FRW_NAME | List of Names (e.g. Fieldnames) | 20081213 | ||
2 | Importing | IO_STRUCDESCR | Call by reference | Object reference (TYPE REF TO) | CL_ABAP_STRUCTDESCR | Runtime Type Services | 20081213 | ||
3 | Importing | IS_STRUC1 | Call by reference | Type reference (TYPE) | ANY | 20081213 | |||
4 | Importing | IS_STRUC2 | Call by reference | Type reference (TYPE) | ANY | 20081213 | |||
5 | Importing | IV_PREFIX | Call by reference | Type reference (TYPE) | STRING | 20081213 | |||
6 | Importing | IV_SUFFIX | Call by reference | Type reference (TYPE) | STRING | 20081213 |
Method GET_UNEQUAL_FIELDS on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method HAS_A_TEST Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | EV_HAS_A_TEST | Value transfer | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
2 | Importing | IV_TESTDATA_CONTAINER_NAME | Call by reference | Type reference (TYPE) | ETP_NAME | Name of a Parameter or Command Interface | 20081213 | ||
3 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method HAS_A_TEST on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method INITIALIZE_ENVIRONMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_OBJ_KEY | Business Object Version | 20081213 | ||
2 | Importing | IV_CHECK_BO_ESR_AVAILABILITY | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
3 | Importing | IV_DO_KEY | Call by reference | Type reference (TYPE) | /BOBF/OBM_OBJ_KEY | Business Object Version | 20081213 |
Method INITIALIZE_ENVIRONMENT on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method INITIALIZE_TESTDATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_NAME_TABTYPE | Table with Variant Names | 20081213 | ||
2 | Exporting | EV_TESTDATA_CONTAINER_NAME | Call by reference | Type reference (TYPE) | ETP_NAME | Name of a Parameter or Command Interface | 20081213 | ||
3 | Importing | IT_META_MODEL | Call by reference | Type reference (TYPE) | /BOBF/T_TOOL_META_MODEL | Model information for testdata container | 20081213 | ||
4 | Importing | IV_CONTENT_CAT | Call by reference | Type reference (TYPE) | /BOBF/OBM_CONTENT_CAT | Type of Object-Specific Logic | 20081213 | ||
5 | Importing | IV_CONTENT_KEY | Call by reference | Type reference (TYPE) | /BOBF/CONF_KEY | NodeID | 20081213 | ||
6 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method INITIALIZE_TESTDATA on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method LEAVE_CHANGE_STACK Signature
Method LEAVE_CHANGE_STACK on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method LEAVE_CHANGE_STACK on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method PREPARE_BUFFER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IT_META_MODEL | Call by reference | Type reference (TYPE) | /BOBF/T_TOOL_META_MODEL | Model information for testdata container | 20081213 | ||
2 | Importing | IV_TESTDATA_CONTAINER_NAME | Call by reference | Type reference (TYPE) | ETP_NAME | Name of a Parameter or Command Interface | 20081213 | ||
3 | Importing | IV_USE_OWN_BUFFER | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
4 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method PREPARE_BUFFER on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method PREPARE_MOCK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | ET_MOCK_BO_KEY | Value transfer | Type reference (TYPE) | /BOBF/T_FRW_KEY2 | Key table | 20090319 | ||
2 | Importing | IT_MOCK_CONF | Call by reference | Type reference (TYPE) | /BOBF/T_TOOL_AUNIT_MOCK_BO | Table for mock BO configuration | 20090316 |
Method PREPARE_MOCK on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method READ_BO_CONTAINER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_DATA | Call by reference | Type reference (TYPE) | ANY | 20081213 | |||
2 | Importing | IS_MESSAGE | Call by reference | Type reference (TYPE) | TY_AUNIT_MESSAGE | Error message if read is not successful | 20081213 | ||
3 | Importing | IV_CONTAINER_NAME | Call by reference | Type reference (TYPE) | ETOBJ_NAME | eCATT Object | 20081213 | ||
4 | Importing | IV_PARNAME | Call by reference | Type reference (TYPE) | ETP_NAME | Name of a Parameter or Command Interface | 20081213 | ||
5 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method READ_BO_CONTAINER on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method READ_TD_CONTAINER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CV_PAR_MISSING | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | ||
2 | Exporting | EV_DATA | Call by reference | Type reference (TYPE) | ANY | 20081213 | |||
3 | Exporting | EV_REF | Call by reference | Object reference (TYPE REF TO) | DATA | 20081213 | |||
4 | Importing | IS_MESSAGE | Call by reference | Type reference (TYPE) | TY_AUNIT_MESSAGE | Error message if read is not successful | 20081213 | ||
5 | Importing | IV_AUNIT_PARAM | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_TRUE | AUnit parameter or model entity? | 20081213 | |
6 | Importing | IV_CONTAINER_NAME | Call by reference | Type reference (TYPE) | ETOBJ_NAME | eCATT Object | 20081213 | ||
7 | Importing | IV_PARNAME | Call by reference | Type reference (TYPE) | ETP_NAME | Name of a Parameter or Command Interface | 20081213 | ||
8 | Importing | IV_PARNAME_DEFAULT | Call by reference | Type reference (TYPE) | ETP_NAME | Name of a Parameter or Command Interface | 20081213 | ||
9 | Importing | IV_VALUE_REQUIRED | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_TRUE | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20081213 | |
10 | Importing | IV_VARIANT | Call by reference | Type reference (TYPE) | ETVAR_ID | Variant name | 20081213 |
Method READ_TD_CONTAINER on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method RELEASE_MOCK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IT_MOCK_BO_KEY | Call by reference | Type reference (TYPE) | /BOBF/T_FRW_KEY2 | mocked BO keys | 20090319 |
Method RELEASE_MOCK on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method RETRIEVE Signature
Method RETRIEVE on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method RETRIEVE on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method RETRIEVE_BY_ASSOCIATION Signature
Method RETRIEVE_BY_ASSOCIATION on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method RETRIEVE_BY_ASSOCIATION on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
Method UPDATE Signature
Method UPDATE on class /BOBF/CL_TOOL_AUNIT_FRW has no parameter.
Method UPDATE on class /BOBF/CL_TOOL_AUNIT_FRW has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 702 |