Message Number list used by SAP ABAP Program LOIU_VA_BUILD_PROFILESF18 (Include LOIU_VA_BUILD_PROFILESF18)
SAP ABAP Program
LOIU_VA_BUILD_PROFILESF18 (Include LOIU_VA_BUILD_PROFILESF18) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | OIUPR - 789 | FATAL: FURTHEST UPSTREAM NODES NOT FOUND | ||
| 2 | OIUPR - 601 | A Measurement Point tied to the contract does not support the product | ||
| 3 | OIUPR - 602 | No PAM data exists for the contract to which the MP is cross referenced | ||
| 4 | OIUPR - 611 | Multiple plant allocation methods exist for the listed FUN | ||
| 5 | OIUPR - 624 | Contaminating percents found for more than one product at listed WL/WC | ||
| 6 | OIUPR - 625 | Different contaminating percents found for a product at listed WL/WC | ||
| 7 | OIUPR - 627 | PAM specified for the product is not compatible | ||
| 8 | OIUPR - 642 | Invalid Well Class for WL/WC &/&, Prod &, and VT & | ||
| 9 | OIUPR - 787 | FATAL: INVALID DN REFERENCE NO | ||
| 10 | OIUPR - 788 | Unable to set traverse starting position: & | ||
| 11 | OIUPR - 600 | Processing product not covered by a plant allocation method | ||
| 12 | OIUPR - 790 | FATAL: FURTHEST DOWNSTREAM NODES NOT FOUND | ||
| 13 | OIUPR - 791 | FATAL: RECORD NOT FOUND FOR PRODUCT CORRESPONDING TO MATERIAL | ||
| 14 | OIUPR - 819 | FATAL: DOWNSTREAM OF WC & & IS A WELL & &. | ||
| 15 | OIUPR - 820 | Network Measurement Point internal table is empty | ||
| 16 | OIUPR - 821 | Network is a fuel system and has furthest upstream node wc's | ||
| 17 | OIUPR - 822 | Network Well Completion internal table is empty | ||
| 18 | OIUPR - 823 | Network Well Completion Profile internal table is empty | ||
| 19 | OIUPR - 824 | Network Measurement Point Profile internal table is empty | ||
| 20 | OIUPR - 523 | A gas plant MP was found in a DN not specified as a gas plant | ||
| 21 | OIUPR - 508 | MP Dated Characteristics were not found for MP & | ||
| 22 | OIUPR - 511 | O/C Mix DN has inconsistent MPAP for material & | ||
| 23 | OIUPR - 512 | A tank battery MP is required in the structure of DN's that have tanks | ||
| 24 | OIUPR - 514 | More than one tank battery exists in the DN structure | ||
| 25 | OIUPR - 518 | A MP Allocation Profile was not found for listed material and volume type | ||
| 26 | OIUPR - 519 | Inconsistency found in upstream MP's profile | ||
| 27 | OIUPR - 520 | Traversed from an oil or gas well without passing through a tank battery | ||
| 28 | OIUPR - 522 | Delivery Network is a gas plant and no gas plant MP was found | ||
| 29 | OIUPR - 506 | 1-to-1 relationship between MP & and its upstream node must exist | ||
| 30 | OIUPR - 524 | The well class code is invalid | ||
| 31 | OIUPR - 527 | Characteristics for WellComp & / & not in table & | ||
| 32 | OIUPR - 529 | A gas plant inlet was not found within the structure of the Gas Plant DN | ||
| 33 | OIUPR - 530 | A gas plant inlet was found in a DN that is not a Gas Plant | ||
| 34 | OIUPR - 531 | Indicated material is inconsistent with the well class for the wc | ||
| 35 | OIUPR - 534 | Fuel system has a produced or purchased fuel point as FUN | ||
| 36 | OIUPR - 598 | Header Plant Allocation Method info not found for contract & effective & | ||
| 37 | OIUPR - 599 | Detail Plant Allocation Method info not found for contract & effective & |