Table/Structure Field list used by SAP ABAP Program LEPA1F01 (Include LEPA1F01)
SAP ABAP Program
LEPA1F01 (Include LEPA1F01) is using
# | Object Type | Object Name | Object Description | Note |
---|---|---|---|---|
![]() |
![]() |
|||
1 | ![]() |
EABL - ABLBELNR | Internal ID for meter reading document | |
2 | ![]() |
EABL - ABLHINW | Note from meter reader | |
3 | ![]() |
EABL - ABLSTAT | Meter Reading Status | |
4 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | |
5 | ![]() |
EABL - ADATSOLL | Scheduled meter reading date | |
6 | ![]() |
EABL - ATIM | Meter reading time (relevant to billing) | |
7 | ![]() |
EABL - ENTRYNUMB | Entry number for fast entry | |
8 | ![]() |
EABL - GERNR | Device | |
9 | ![]() |
EABL - ISTABLART | Meter reading type | |
10 | ![]() |
EABL - N_ZWSTAND | Places After Decimal Point in the Meter Reading | |
11 | ![]() |
EABL - N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | |
12 | ![]() |
EABL - POPCODE | Dependent validation | |
13 | ![]() |
EABL - PRUEFPKT | Independent validation | |
14 | ![]() |
EABL - STABLHW | Control of follow-up action for MR result with MR note | |
15 | ![]() |
EABL - STANZNAC | Number of decimal places for register | |
16 | ![]() |
EABL - STANZVOR | Number of predecimal places for register | |
17 | ![]() |
EABL - V_ZWSTAND | Places Before Decimal Point in Meter Reading | |
18 | ![]() |
EABL - V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | |
19 | ![]() |
EABL - ZWNUMMER | Register | |
20 | ![]() |
EABLG - ABLBELNR | Internal ID for meter reading document | |
21 | ![]() |
EABLG - ABLESGR | Meter reading reason | |
22 | ![]() |
EABLH - SELECT2 | Internal: Selection indicator for MR orders or MR results | |
23 | ![]() |
EASTI - AB | Date from which time slice is valid | |
24 | ![]() |
EASTI - BIS | Date at Which a Time Slice Expires | |
25 | ![]() |
EASTI - INDEXNR | Consecutive number of register relationship | |
26 | ![]() |
EASTI - LOGIKZW | Logical register number | |
27 | ![]() |
EASTI - OPCODE | Operation code: Role of register in relationship | |
28 | ![]() |
EASTI - ZWZUART | Register relationship type | |
29 | ![]() |
EASTIH - PRUEFGR | Validation group for dependent validations | |
30 | ![]() |
EASTS - AB | Date from which time slice is valid | |
31 | ![]() |
EASTS - BIS | Date at Which a Time Slice Expires | |
32 | ![]() |
EASTS - LOGIKZW | Logical register number | |
33 | ![]() |
EDEPVALOBJ - CORR_DYNNR | Number of the following screen | |
34 | ![]() |
EDEPVALOBJ - CORR_SUBSCR | Number of the following screen | |
35 | ![]() |
EDEPVALOBJ - DEVIATION | Actual deviation | |
36 | ![]() |
EDEPVALOBJ - DIM_DEVIATION | Dimension of actual deviation | |
37 | ![]() |
EDEPVALOBJ - INDEXNR | Consecutive number of register relationship | |
38 | ![]() |
EDEPVALOBJ - MASSBILL | Unit of measurement for billing | |
39 | ![]() |
EDEPVALOBJ - MAXIMUM | Meter reading recorded | |
40 | ![]() |
EDEPVALOBJ - MINIMUM | Meter reading recorded | |
41 | ![]() |
EDEPVALOBJ - MSGID | Message Class | |
42 | ![]() |
EDEPVALOBJ - MSGNO | Message Number | |
43 | ![]() |
EDEPVALOBJ - MSGTY | Message Type | |
44 | ![]() |
EDEPVALOBJ - MSGV1 | Message Variable | |
45 | ![]() |
EDEPVALOBJ - MSGV2 | Message Variable | |
46 | ![]() |
EDEPVALOBJ - MSGV3 | Message Variable | |
47 | ![]() |
EDEPVALOBJ - MSGV4 | Message Variable | |
48 | ![]() |
EDEPVALOBJ - PERMIS_DEVIATION | Permissible deviation from guide value | |
49 | ![]() |
EDEPVALOBJ - POPCODE | Dependent validation | |
50 | ![]() |
EDEPVALOBJ - VALUE1 | Meter reading recorded | |
51 | ![]() |
EDEPVALOBJ - VALUE2 | Meter reading recorded | |
52 | ![]() |
EMSG_GEN - MSGID | Message Class | |
53 | ![]() |
EMSG_GEN - MSGNO | Message Number | |
54 | ![]() |
EMSG_GEN - MSGTY | Message type | |
55 | ![]() |
EMSG_GEN - OKCODE | OK code for message object | |
56 | ![]() |
EMSG_MSG - KZ_BREAK | Indicator: Breakpoint | |
57 | ![]() |
EMSG_MSG - KZ_EXC | Indicator: Output EXCEPTION | |
58 | ![]() |
EMSG_MSG - KZ_MSG | Indicator: Output message | |
59 | ![]() |
EMSG_MSG - MSGID | Message Class | |
60 | ![]() |
EMSG_MSG - MSGNO | Message Number | |
61 | ![]() |
EMSG_MSG - MSGTY | Message Type | |
62 | ![]() |
EMSG_MSG - MSGV1 | Message Variable | |
63 | ![]() |
EMSG_MSG - MSGV2 | Message Variable | |
64 | ![]() |
EMSG_MSG - MSGV3 | Message Variable | |
65 | ![]() |
EMSG_MSG - MSGV4 | Message Variable | |
66 | ![]() |
ERCHZ - I_ABRMENGE | Billing quantity for internal billing format | |
67 | ![]() |
ERCHZ_N - I_ABRMENGE | Billing quantity for internal billing format | |
68 | ![]() |
ETDZ - AB | Date from which time slice is valid | |
69 | ![]() |
ETDZ - BIS | Date at Which a Time Slice Expires | |
70 | ![]() |
ETDZ - EQUNR | Equipment Number | |
71 | ![]() |
ETDZ - LOGIKZW | Logical register number | |
72 | ![]() |
ETDZ - ZWNUMMER | Register | |
73 | ![]() |
EZUZ - AB | Date from which time slice is valid | |
74 | ![]() |
EZUZ - ABRFAKT | Billing factor | |
75 | ![]() |
EZUZ - BIS | Date at Which a Time Slice Expires | |
76 | ![]() |
EZUZ - LOGIKZW | Logical register number | |
77 | ![]() |
EZWG - ZWTYP | Register category | |
78 | ![]() |
ISU00_OBJ_CONTR - CALLED_BY_IDOC | Called by IDoc | |
79 | ![]() |
ISU00_OBJ_CONTR - INPERR | Indicator: input fields in this field group | |
80 | ![]() |
ISU00_OBJ_CONTR - NO_DIALOG | Suppress database update | |
81 | ![]() |
ISU00_OBJ_CONTR - SETCURDYNNR | Dynpro Number | |
82 | ![]() |
ISU00_OBJ_CONTR - SETCURFIELD | Cursor field | |
83 | ![]() |
ISU00_OBJ_CONTR - SETCURLINE | Index of Current Step Loop Line | |
84 | ![]() |
ISU17_METERDOCU_MASTERDATA - IEASTS | ISU17_METERDOCU_MASTERDATA-IEASTS | |
85 | ![]() |
ISU17_METERDOCU_MASTERDATA - IETDZ | ISU17_METERDOCU_MASTERDATA-IETDZ | |
86 | ![]() |
ISU17_METERDOCU_MASTERDATA - IEZUZ | ISU17_METERDOCU_MASTERDATA-IEZUZ | |
87 | ![]() |
ISU_RANGES - LOW | ABAP/4: Selection value (LOW or HIGH value, external format) | |
88 | ![]() |
ISU_RANGES - OPTION | ABAP: Selection option (EQ/BT/CP/...) | |
89 | ![]() |
ISU_RANGES - SIGN | ABAP: ID: I/E (include/exclude values) | |
90 | ![]() |
PREVMR - PRMR_ADAT | Date of Previous Meter Reading for Register | |
91 | ![]() |
PROGDATA - COMPT | INTERNAL: calculation format for readings and consumption | |
92 | ![]() |
PROGDATA - COMPT_EXP | INTERNAL: calculation format for readings and consumption | |
93 | ![]() |
REABLD - ABLBELNR | Internal ID for meter reading document | |
94 | ![]() |
REABLD - ABLHINW | Note from meter reader | |
95 | ![]() |
REABLD - ABLHIN_OLD | Note from meter reader | |
96 | ![]() |
REABLD - ABLSTAT | Meter Reading Status | |
97 | ![]() |
REABLD - ABRFAKT | Billing factor | |
98 | ![]() |
REABLD - ADAT | Meter reading date relevant to billing | |
99 | ![]() |
REABLD - ADATSOLL | Scheduled meter reading date | |
100 | ![]() |
REABLD - ADAT_OLD | Meter reading date relevant to billing | |
101 | ![]() |
REABLD - BACKBILL_STAT | Backbilling Status | |
102 | ![]() |
REABLD - BUKRS | Company Code | |
103 | ![]() |
REABLD - COMPT | INTERNAL: calculation format for readings and consumption | |
104 | ![]() |
REABLD - COMPT_CHANGED | Indicators | |
105 | ![]() |
REABLD - COMPT_EXP | INTERNAL: calculation format for readings and consumption | |
106 | ![]() |
REABLD - CORR_DYNNR | Dynpro Number | |
107 | ![]() |
REABLD - DEV_STATE | Device status | |
108 | ![]() |
REABLD - ENTNO_OLD | Entry number for fast entry | |
109 | ![]() |
REABLD - ENTRYNUMB | Entry number for fast entry | |
110 | ![]() |
REABLD - GERNR | Device | |
111 | ![]() |
REABLD - ISTABLART | Meter reading type | |
112 | ![]() |
REABLD - ISTABLART_OLD | Meter reading type | |
113 | ![]() |
REABLD - LOGIKZW | Logical register number | |
114 | ![]() |
REABLD - MSGID | Message Class | |
115 | ![]() |
REABLD - MSGNO | Message Number | |
116 | ![]() |
REABLD - MSGTY | Message Type | |
117 | ![]() |
REABLD - MSGV1 | Message Variable | |
118 | ![]() |
REABLD - MSGV2 | Message Variable | |
119 | ![]() |
REABLD - MSGV3 | Message Variable | |
120 | ![]() |
REABLD - MSGV4 | Message Variable | |
121 | ![]() |
REABLD - N_ZWSTAND | Places After Decimal Point in the Meter Reading | |
122 | ![]() |
REABLD - POPCODE | Dependent validation | |
123 | ![]() |
REABLD - PRMR_ADAT | Date of Previous Meter Reading for Register | |
124 | ![]() |
REABLD - PRUEFPKT | Independent validation | |
125 | ![]() |
REABLD - SPARTE | Division | |
126 | ![]() |
REABLD - STABLHW | Control of follow-up action for MR result with MR note | |
127 | ![]() |
REABLD - STANZNAC | Number of decimal places for register | |
128 | ![]() |
REABLD - STANZVOR | Number of predecimal places for register | |
129 | ![]() |
REABLD - TARIFART | Rate Type | |
130 | ![]() |
REABLD - V_ZWSTAND | Places Before Decimal Point in Meter Reading | |
131 | ![]() |
REABLD - ZWNUMMER | Register | |
132 | ![]() |
REABLD - ZWSTAND | Meter reading recorded | |
133 | ![]() |
REABLD - ZWST_OLD | Meter reading recorded | |
134 | ![]() |
REABLD - ZWTYP | Register category | |
135 | ![]() |
REGEN - KENNZX | Indicators | |
136 | ![]() |
SYST - DATUM | ABAP System Field: Current Date of Application Server | |
137 | ![]() |
SYST - DYNNR | ABAP System Field: Current Dynpro Number | |
138 | ![]() |
SYST - MSGV1 | ABAP System Field: Message Variable | |
139 | ![]() |
SYST - MSGV2 | ABAP System Field: Message Variable | |
140 | ![]() |
SYST - MSGV3 | ABAP System Field: Message Variable | |
141 | ![]() |
SYST - MSGV4 | ABAP System Field: Message Variable | |
142 | ![]() |
SYST - STEPL | ABAP System Field: Current Step Loop or Table Control Line | |
143 | ![]() |
SYST - TABIX | ABAP System Field: Row Index of Internal Tables | |
144 | ![]() |
TE259 - STABLHW | Control of follow-up action for MR result with MR note | |
145 | ![]() |
TE402 - ONLY_BILLING_REL | Field "MRR triggers billing" is permitted | |
146 | ![]() |
TE406 - ONLY_BILLING_REL | Main operation code for field "MRR triggers billing" | |
147 | ![]() |
TE410 - BUKRS | Company Code | |
148 | ![]() |
TE410 - NOCHGE_BACKBMRES | No change to billed reading during floating backbilling | |
149 | ![]() |
TE410 - NOCHGE_DPCMRES | No Change to Billed Meter Reading for Dynamic Period Control | |
150 | ![]() |
TE410 - SPARTE | Division | |
151 | ![]() |
TE410S - NO_DEPVAL_SECREG | Do not include secondary meter in dependent validation | |
152 | ![]() |
TE413 - ZWZUART | Register relationship type | |
153 | ![]() |
TE414 - FEHLKLAS | Error class for validations | |
154 | ![]() |
TE414 - POPCODE | Dependent validation | |
155 | ![]() |
TE902 - POPCODE | Dependent validation | |
156 | ![]() |
TE903 - DYNNR | Number of the following screen | |
157 | ![]() |
TE903 - NO_FUNCALL | No of Function Modules for User-Defined Dependent Validation | |
158 | ![]() |
TE903 - POPCODE | Dependent validation | |
159 | ![]() |
V_EGER - GERAET | Serial Number | |
160 | ![]() |
V_TE414 - POPCODE | Dependent validation |