Table/Structure Field list used by SAP ABAP Program LELINF03 (Include LELINF03: CHECK_PREP_AND_ENTRY)
SAP ABAP Program
LELINF03 (Include LELINF03: CHECK_PREP_AND_ENTRY) is using
# | Object Type | Object Name | Object Description | Note |
---|---|---|---|---|
![]() |
![]() |
|||
1 | ![]() |
EABL - ABLBELNR | Internal ID for meter reading document | |
2 | ![]() |
EABL - ABLESART | Scheduled meter reading category | |
3 | ![]() |
EABL - ABLESTYP | Meter reading category | |
4 | ![]() |
EABL - ABLSTAT | Meter Reading Status | |
5 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | |
6 | ![]() |
EABL - ADATREAL | [JBP] Real Meter Reading Date | |
7 | ![]() |
EABL - ADATSOLL | Scheduled meter reading date | |
8 | ![]() |
EABL - ADATTATS | Actual meter reading date | |
9 | ![]() |
EABL - AKTIV | Meter reading active | |
10 | ![]() |
EABL - ATIM | Meter reading time (relevant to billing) | |
11 | ![]() |
EABL - ATIMREAL | [JBP] Real Meter Reading Time | |
12 | ![]() |
EABL - BP | Selection of Billing Period: Standard or JBP | |
13 | ![]() |
EABL - ENTRYNUMB | Entry number for fast entry | |
14 | ![]() |
EABL - EQUNR | Equipment Number | |
15 | ![]() |
EABL - ERDAT | Date on which the record was created | |
16 | ![]() |
EABL - E_ZVBL_BEZDAT | Scheduled meter reading date for base meter reading | |
17 | ![]() |
EABL - GERNR | Device | |
18 | ![]() |
EABL - ISTABLART | Meter reading type | |
19 | ![]() |
EABL - MASSREAD | Unit of measurement for meter reading | |
20 | ![]() |
EABL - NACHERF | Meter reading result inserted or modified | |
21 | ![]() |
EABL - N_ZWSTAND | Places After Decimal Point in the Meter Reading | |
22 | ![]() |
EABL - N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | |
23 | ![]() |
EABL - PRUEFZAHL | Check number | |
24 | ![]() |
EABL - REM_ABLBELNR | [JBP] Suppressed MR Document Number | |
25 | ![]() |
EABL - STANZNAC | Number of decimal places for register | |
26 | ![]() |
EABL - STANZVOR | Number of predecimal places for register | |
27 | ![]() |
EABL - THGDATUM | Gas allocation date | |
28 | ![]() |
EABL - V_ZWSTAND | Places Before Decimal Point in Meter Reading | |
29 | ![]() |
EABL - V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | |
30 | ![]() |
EABL - ZUORDDAT | Meter reading allocation date | |
31 | ![]() |
EABL - ZWNUMMER | Register | |
32 | ![]() |
EABLD - ABLBELNR | Internal ID for meter reading document | |
33 | ![]() |
EABLD - ABLEINH | Meter reading unit | |
34 | ![]() |
EABLD - ABLESART | Scheduled meter reading category | |
35 | ![]() |
EABLD - ABLESGR | Meter reading reason | |
36 | ![]() |
EABLD - ABLESTYP | Meter reading category | |
37 | ![]() |
EABLD - ABLSTAT | Meter Reading Status | |
38 | ![]() |
EABLD - ABRDATS | Scheduled Billing Date | |
39 | ![]() |
EABLD - ADAT | Meter reading date relevant to billing | |
40 | ![]() |
EABLD - ADATSOLL | Scheduled meter reading date | |
41 | ![]() |
EABLD - ADATTATS | Actual meter reading date | |
42 | ![]() |
EABLD - AKTIV | Meter reading active | |
43 | ![]() |
EABLD - ANLAGE | Installation | |
44 | ![]() |
EABLD - ATIM | Meter reading time (relevant to billing) | |
45 | ![]() |
EABLD - BP | Selection of Billing Period: Standard or JBP | |
46 | ![]() |
EABLD - ENTRYNUMB | Entry number for fast entry | |
47 | ![]() |
EABLD - EQUNR | Equipment Number | |
48 | ![]() |
EABLD - E_INTERNET | Meter Reading via Internet | |
49 | ![]() |
EABLD - E_ZVBL_BEZDAT | Scheduled meter reading date for base meter reading | |
50 | ![]() |
EABLD - GERAET | Device | |
51 | ![]() |
EABLD - GERNR | Device | |
52 | ![]() |
EABLD - ISTABLART | Meter reading type | |
53 | ![]() |
EABLD - MASSREAD | Unit of measurement for meter reading | |
54 | ![]() |
EABLD - NACHERF | Meter reading result inserted or modified | |
55 | ![]() |
EABLD - N_ZWSTAND | Places After Decimal Point in the Meter Reading | |
56 | ![]() |
EABLD - N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | |
57 | ![]() |
EABLD - PPM_METER | Prepayment Meter | |
58 | ![]() |
EABLD - PRUEFZAHL | Check number | |
59 | ![]() |
EABLD - SPARTYP | Division category | |
60 | ![]() |
EABLD - STANZNAC | Number of decimal places for register | |
61 | ![]() |
EABLD - STANZVOR | Number of predecimal places for register | |
62 | ![]() |
EABLD - THGDATUM | Gas allocation date | |
63 | ![]() |
EABLD - UNTERDR | Suppression indicator | |
64 | ![]() |
EABLD - V_ZWSTAND | Places Before Decimal Point in Meter Reading | |
65 | ![]() |
EABLD - V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | |
66 | ![]() |
EABLD - ZUORDDAT | Meter reading allocation date | |
67 | ![]() |
EABLD - ZWNUMMER | Register | |
68 | ![]() |
EABLD - ZWTYP | Register category | |
69 | ![]() |
EABLG - ABLBELNR | Internal ID for meter reading document | |
70 | ![]() |
EABLG - ABLEINH | Meter reading unit | |
71 | ![]() |
EABLG - ABLESGR | Meter reading reason | |
72 | ![]() |
EABLG - ABRDATS | Scheduled Billing Date | |
73 | ![]() |
EABLG - ADATSOLL | Scheduled meter reading date | |
74 | ![]() |
EABLG - ANLAGE | Installation | |
75 | ![]() |
EABLG - UNTERDR | Suppression indicator | |
76 | ![]() |
EABL_JBP - ADATREAL | [JBP] Real Meter Reading Date | |
77 | ![]() |
EABL_JBP - ATIMREAL | [JBP] Real Meter Reading Time | |
78 | ![]() |
EABL_JBP - BP | Selection of Billing Period: Standard or JBP | |
79 | ![]() |
EABL_JBP - REM_ABLBELNR | [JBP] Suppressed MR Document Number | |
80 | ![]() |
EASTS - AB | Date from which time slice is valid | |
81 | ![]() |
EJBP - BP | Selection of Billing Period: Standard or JBP | |
82 | ![]() |
EMSG_GEN - MSGID | Message Class | |
83 | ![]() |
EMSG_GEN - MSGNO | Message Number | |
84 | ![]() |
EMSG_GEN - MSGTY | Message type | |
85 | ![]() |
EMSG_GEN - OKCODE | OK code for message object | |
86 | ![]() |
EMSG_MSG - KZ_BREAK | Indicator: Breakpoint | |
87 | ![]() |
EMSG_MSG - KZ_EXC | Indicator: Output EXCEPTION | |
88 | ![]() |
EMSG_MSG - KZ_MSG | Indicator: Output message | |
89 | ![]() |
EMSG_MSG - MSGID | Message Class | |
90 | ![]() |
EMSG_MSG - MSGNO | Message Number | |
91 | ![]() |
EMSG_MSG - MSGTY | Message Type | |
92 | ![]() |
EMSG_MSG - MSGV1 | Message Variable | |
93 | ![]() |
EMSG_MSG - MSGV2 | Message Variable | |
94 | ![]() |
EMSG_MSG - MSGV3 | Message Variable | |
95 | ![]() |
EMSG_MSG - MSGV4 | Message Variable | |
96 | ![]() |
ETDZ - AB | Date from which time slice is valid | |
97 | ![]() |
ETDZ - BIS | Date at Which a Time Slice Expires | |
98 | ![]() |
ETDZ - EQUNR | Equipment Number | |
99 | ![]() |
ETDZ - LOGIKZW | Logical register number | |
100 | ![]() |
ETDZ - ZWNUMMER | Register | |
101 | ![]() |
EZWG - ZWTYP | Register category | |
102 | ![]() |
ISU17_METERREAD_AUTO - EABL_USE | Indicators | |
103 | ![]() |
ISU_ADMINL - ERDAT | Date on which the record was created | |
104 | ![]() |
REG30_GERA - ACTION | Action in the work list for installation, etc. (IS-U) | |
105 | ![]() |
REGEN - KENNZX | Indicators | |
106 | ![]() |
REGEN - MAXCOUNT | Maximum number of devices to be selected | |
107 | ![]() |
REGEN - UPD_ONLINE | Update online | |
108 | ![]() |
SYST - DATUM | ABAP System Field: Current Date of Application Server | |
109 | ![]() |
SYST - INDEX | ABAP System Field: Loop Index | |
110 | ![]() |
SYST - MSGID | ABAP System Field: Message ID | |
111 | ![]() |
SYST - MSGNO | ABAP System Field: Message Number | |
112 | ![]() |
SYST - MSGTY | ABAP System Field: Message Type | |
113 | ![]() |
SYST - MSGV1 | ABAP System Field: Message Variable | |
114 | ![]() |
SYST - MSGV2 | ABAP System Field: Message Variable | |
115 | ![]() |
SYST - MSGV3 | ABAP System Field: Message Variable | |
116 | ![]() |
SYST - MSGV4 | ABAP System Field: Message Variable | |
117 | ![]() |
SYST - TABIX | ABAP System Field: Row Index of Internal Tables | |
118 | ![]() |
SYST - UZEIT | ABAP System Field: Current Time of Application Server | |
119 | ![]() |
TE422 - ABLART | Meter reading by customer | |
120 | ![]() |
TE422 - TERMSCHL | Meter reading unit | |
121 | ![]() |
TE610 - STAUFTERZ | Always create meter reading order | |
122 | ![]() |
TE614 - ABLESART | Meter reading category | |
123 | ![]() |
TESPT - SPARTYP | Division category | |
124 | ![]() |
TFDIR - FUNCNAME | Name of Function Module |