Table/Structure Field list used by SAP ABAP Program LELHLF01 (Include LELHLF01)
SAP ABAP Program
LELHLF01 (Include LELHLF01) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | DEMAND_TAB - AKTIV | Meter reading active | ||
| 2 | DEMAND_TAB - AB | Date from which time slice is valid | ||
| 3 | DEMAND_TAB - ZWSTAND_PREV | Meter reading recorded | ||
| 4 | DEMAND_TAB - ZWSTAND | Meter reading recorded | ||
| 5 | DEMAND_TAB - HERKUNFT | Origin | ||
| 6 | DEMAND_TAB - LEISTUNGSWERT | Expected consumption: internal format | ||
| 7 | DEMAND_TAB - BIS | Date at Which a Time Slice Expires | ||
| 8 | EABL - ABLBELNR | Internal ID for meter reading document | ||
| 9 | EABL - ABLSTAT | Meter Reading Status | ||
| 10 | EABL - ADAT | Meter reading date relevant to billing | ||
| 11 | EABL - ADATSOLL | Scheduled meter reading date | ||
| 12 | EABL - AKTIV | Meter reading active | ||
| 13 | EABL - ATIM | Meter reading time (relevant to billing) | ||
| 14 | EABL - EQUNR | Equipment Number | ||
| 15 | EABL - GERNR | Device | ||
| 16 | EABL - N_ZWSTAND | Places After Decimal Point in the Meter Reading | ||
| 17 | EABL - N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | ||
| 18 | EABL - STANZVOR | Number of predecimal places for register | ||
| 19 | EABL - V_ZWSTAND | Places Before Decimal Point in Meter Reading | ||
| 20 | EABL - V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | ||
| 21 | EABL - ZWNUMMER | Register | ||
| 22 | EABLG - ANLAGE | Installation | ||
| 23 | EABLG - ABLBELNR | Internal ID for meter reading document | ||
| 24 | EABLG - ABLESGR | Meter reading reason | ||
| 25 | EABLH - I_VERBERW | Expected consumption: internal format | ||
| 26 | EABLH - I_ZWSTERW | Expected meter reading: internal format | ||
| 27 | EADZ - AB | Date from which time slice is valid | ||
| 28 | EADZ - BIS | Date at Which a Time Slice Expires | ||
| 29 | EADZ - LOGIKZW | Logical register number | ||
| 30 | EANL - ANLAGE | Installation | ||
| 31 | EANLKEY - ANLAGE | Installation | ||
| 32 | EASTE - LOGIKZW | Logical register number | ||
| 33 | EASTE - PERVERBR | Period Consumption | ||
| 34 | EASTE - AB | Start date for consumption period | ||
| 35 | EMSG_GEN - MSGID | Message Class | ||
| 36 | EMSG_GEN - MSGNO | Message Number | ||
| 37 | EMSG_GEN - MSGTY | Message type | ||
| 38 | EMSG_GEN - OKCODE | OK code for message object | ||
| 39 | EMSG_MSG - MSGV4 | Message Variable | ||
| 40 | EMSG_MSG - MSGV3 | Message Variable | ||
| 41 | EMSG_MSG - MSGV2 | Message Variable | ||
| 42 | EMSG_MSG - MSGV1 | Message Variable | ||
| 43 | EMSG_MSG - MSGNO | Message Number | ||
| 44 | EMSG_MSG - MSGID | Message Class | ||
| 45 | EMSG_MSG - MSGTY | Message Type | ||
| 46 | EMSG_MSG - KZ_BREAK | Indicator: Breakpoint | ||
| 47 | EMSG_MSG - KZ_EXC | Indicator: Output EXCEPTION | ||
| 48 | EMSG_MSG - KZ_MSG | Indicator: Output message | ||
| 49 | ERCHZ - I_ABRMENGE | Billing quantity for internal billing format | ||
| 50 | ERCHZ_N - I_ABRMENGE | Billing quantity for internal billing format | ||
| 51 | ETDZ - AB | Date from which time slice is valid | ||
| 52 | ETDZ - BIS | Date at Which a Time Slice Expires | ||
| 53 | ETDZ - EQUNR | Equipment Number | ||
| 54 | ETDZ - LOGIKZW | Logical register number | ||
| 55 | ETDZ - MASSREAD | Unit of measurement for meter reading | ||
| 56 | ETDZ - SPARTYP | Division category | ||
| 57 | ETDZ - STANZVOR | Places before the decimal point in a register | ||
| 58 | ETDZ - ZWFAKT | Register factor | ||
| 59 | ETDZ - ZWNUMMER | Register | ||
| 60 | ETDZ - ZWTYP | Register category | ||
| 61 | EZUZ - ZUART | Device allocation type | ||
| 62 | EZUZ - LOGIKZW | Logical register number | ||
| 63 | EZUZ - ABRFAKT | Billing factor | ||
| 64 | EZUZ - AB | Date from which time slice is valid | ||
| 65 | EZUZ - BIS | Date at Which a Time Slice Expires | ||
| 66 | EZWG - ZWTYP | Register category | ||
| 67 | ISU17_INTERFACE_STRUCTURES - EABL | ISU17_INTERFACE_STRUCTURES-EABL | ||
| 68 | ISU17_INTERFACE_STRUCTURES - EABLG | ISU17_INTERFACE_STRUCTURES-EABLG | ||
| 69 | ISU17_INTERFACE_STRUCTURES - EABL_PROVIDED | Indicators | ||
| 70 | ISU17_INTERFACE_STRUCTURES - ETDZ_PROVIDED | Indicators | ||
| 71 | ISU17_INTERFACE_STRUCTURES - EZUZ | ISU17_INTERFACE_STRUCTURES-EZUZ | ||
| 72 | ISU17_INTERFACE_STRUCTURES - EZUZ_PROVIDED | Indicators | ||
| 73 | ISU2A_INST_STRUC - IEADZ | ISU2A_INST_STRUC-IEADZ | ||
| 74 | REGEN - KENNZX | Indicators | ||
| 75 | REGEN - UPD_ONLINE | Update online | ||
| 76 | REGEN - MAXCOUNT | Maximum number of devices to be selected | ||
| 77 | SYST - MSGV1 | ABAP System Field: Message Variable | ||
| 78 | SYST - MSGV2 | ABAP System Field: Message Variable | ||
| 79 | SYST - MSGV3 | ABAP System Field: Message Variable | ||
| 80 | SYST - MSGV4 | ABAP System Field: Message Variable | ||
| 81 | SYST - TABIX | ABAP System Field: Row Index of Internal Tables | ||
| 82 | TE221 - MASS | Unit of Measurement | ||
| 83 | TESPT - SPARTYP | Division category | ||
| 84 | V_EGER - GERAET | Serial Number |