Table/Structure Field list used by SAP ABAP Program LELACF01 (Include LELACF01)
SAP ABAP Program
LELACF01 (Include LELACF01) is using
# | Object Type | Object Name | Object Description | Note |
---|---|---|---|---|
![]() |
![]() |
|||
1 | ![]() |
BALHDR - OBJECT | Application log: Object name (Application code) | |
2 | ![]() |
BAPIRETURN1 - LOG_NO | Application log: log number | |
3 | ![]() |
DBERCHZ - N_ABRMENGE | Places after decimal point in billing quantity | |
4 | ![]() |
DBERCHZ - V_ABRMENGE | Places before decimal point in billing quantity | |
5 | ![]() |
EABL - ABLBELNR | Internal ID for meter reading document | |
6 | ![]() |
EABL - ABLESER | Meter reader number | |
7 | ![]() |
EABL - ABLESTYP | Meter reading category | |
8 | ![]() |
EABL - ABLHINW | Note from meter reader | |
9 | ![]() |
EABL - ABLSTAT | Meter Reading Status | |
10 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | |
11 | ![]() |
EABL - ADATERZ | Meter reading date of implausible meter reading result | |
12 | ![]() |
EABL - ADATREAL | [JBP] Real Meter Reading Date | |
13 | ![]() |
EABL - ADATSOLL | Scheduled meter reading date | |
14 | ![]() |
EABL - AKTIV | Meter reading active | |
15 | ![]() |
EABL - ARBAUF | Control Meter Reading Order ID Printed | |
16 | ![]() |
EABL - ATIM | Meter reading time (relevant to billing) | |
17 | ![]() |
EABL - ATIMREAL | [JBP] Real Meter Reading Time | |
18 | ![]() |
EABL - BP | Selection of Billing Period: Standard or JBP | |
19 | ![]() |
EABL - EQUNR | Equipment Number | |
20 | ![]() |
EABL - GERNR | Device | |
21 | ![]() |
EABL - ISTABLART | Meter reading type | |
22 | ![]() |
EABL - MASSBILL | Unit of measurement for billing | |
23 | ![]() |
EABL - N_ZWSTAND | Places After Decimal Point in the Meter Reading | |
24 | ![]() |
EABL - N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | |
25 | ![]() |
EABL - REMOVED | [JBP] Status Indicator: MR Result Suppressed | |
26 | ![]() |
EABL - STABLHW | Control of follow-up action for MR result with MR note | |
27 | ![]() |
EABL - STANZNAC | Number of decimal places for register | |
28 | ![]() |
EABL - STANZVOR | Number of predecimal places for register | |
29 | ![]() |
EABL - V_ZWSTAND | Places Before Decimal Point in Meter Reading | |
30 | ![]() |
EABL - V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | |
31 | ![]() |
EABL - ZWNUMMER | Register | |
32 | ![]() |
EABLG - ABLBELNR | Internal ID for meter reading document | |
33 | ![]() |
EABLG - ABLESGR | Meter reading reason | |
34 | ![]() |
EABLG - ANLAGE | Installation | |
35 | ![]() |
EABLH - I_VERBERW | Expected consumption: internal format | |
36 | ![]() |
EABL_JBP - ADATREAL | [JBP] Real Meter Reading Date | |
37 | ![]() |
EABL_JBP - ATIMREAL | [JBP] Real Meter Reading Time | |
38 | ![]() |
EABL_JBP - BP | Selection of Billing Period: Standard or JBP | |
39 | ![]() |
EABL_JBP - REMOVED | [JBP] Status Indicator: MR Result Suppressed | |
40 | ![]() |
EADZ - LOGIKZW | Logical register number | |
41 | ![]() |
EANL - ANLAGE | Installation | |
42 | ![]() |
EANLKEY - ANLAGE | Installation | |
43 | ![]() |
EASTI - INDEXNR | Consecutive number of register relationship | |
44 | ![]() |
EASTI - LOGIKZW | Logical register number | |
45 | ![]() |
EASTI - OPCODE | Operation code: Role of register in relationship | |
46 | ![]() |
EASTI - ZWZUART | Register relationship type | |
47 | ![]() |
EASTIH - INDEXNR | Consecutive number of register relationship | |
48 | ![]() |
EASTIH - ZWZUART | Register relationship type | |
49 | ![]() |
EASTS - AB | Date from which time slice is valid | |
50 | ![]() |
EASTS - ANLAGE | Installation | |
51 | ![]() |
EASTS - BIS | Date at Which a Time Slice Expires | |
52 | ![]() |
EASTS - LOGIKZW | Logical register number | |
53 | ![]() |
EFKKPATH - LINKID | Read path for the structure reader: Link ID | |
54 | ![]() |
EFKKPATH - TABFROM | Read path for structure reader: Start entity | |
55 | ![]() |
EFKKPATH - TABTO | Read path for structure reader: Target entity | |
56 | ![]() |
EJBP - BP | Selection of Billing Period: Standard or JBP | |
57 | ![]() |
EMSG - BANFN | Purchase requisition number | |
58 | ![]() |
EMSG - MSGID | Message identification | |
59 | ![]() |
EMSG - MSGNO | System Message Number | |
60 | ![]() |
EMSG - MSGTY | Message Type | |
61 | ![]() |
EMSG - MSGV1 | Message variable 01 | |
62 | ![]() |
EMSG - MSGV2 | Message variable 02 | |
63 | ![]() |
EMSG - MSGV3 | Message variable 03 | |
64 | ![]() |
EMSG - MSGV4 | Message variable 04 | |
65 | ![]() |
EMSG_GEN - HANDLE | Message object identification | |
66 | ![]() |
EMSG_GEN - KZ_ACTIVE | Message object is active | |
67 | ![]() |
EMSG_GEN - MSGTY | Message type | |
68 | ![]() |
EMSG_GEN - OKCODE | OK code for message object | |
69 | ![]() |
EMSG_MSG - KZ_BREAK | Indicator: Breakpoint | |
70 | ![]() |
EMSG_MSG - KZ_EXC | Indicator: Output EXCEPTION | |
71 | ![]() |
EMSG_MSG - KZ_MSG | Indicator: Output message | |
72 | ![]() |
EMSG_MSG - MSGID | Message Class | |
73 | ![]() |
EMSG_MSG - MSGNO | Message Number | |
74 | ![]() |
EMSG_MSG - MSGTY | Message Type | |
75 | ![]() |
EMSG_MSG - MSGV1 | Message Variable | |
76 | ![]() |
EMSG_MSG - MSGV2 | Message Variable | |
77 | ![]() |
EMSG_MSG - MSGV3 | Message Variable | |
78 | ![]() |
EMSG_MSG - MSGV4 | Message Variable | |
79 | ![]() |
ERCHZ - I_ABRMENGE | Billing quantity for internal billing format | |
80 | ![]() |
ERCHZ_D - N_ABRMENGE | Places after decimal point in billing quantity | |
81 | ![]() |
ERCHZ_D - V_ABRMENGE | Places before decimal point in billing quantity | |
82 | ![]() |
ERCHZ_N - I_ABRMENGE | Billing quantity for internal billing format | |
83 | ![]() |
ETDZ - AB | Date from which time slice is valid | |
84 | ![]() |
ETDZ - BIS | Date at Which a Time Slice Expires | |
85 | ![]() |
ETDZ - EQUNR | Equipment Number | |
86 | ![]() |
ETDZ - LOGIKZW | Logical register number | |
87 | ![]() |
ETDZ - ZWNUMMER | Register | |
88 | ![]() |
EZUZ - LOGIKZW | Logical register number | |
89 | ![]() |
ISU00_OBJ_CONTR - CALLED_BY_IDOC | Called by IDoc | |
90 | ![]() |
ISU00_OBJ_CONTR - NO_DIALOG | Suppress database update | |
91 | ![]() |
ISU00_OBJ_CONTR - UPD_ONLINE | Update online | |
92 | ![]() |
ISU00_TIMESLICE - AB | Date | |
93 | ![]() |
ISU00_TIMESLICE - BIS | Date | |
94 | ![]() |
ISU07_INSTALL_STRUC - IEADZ | ISU07_INSTALL_STRUC-IEADZ | |
95 | ![]() |
ISU07_INSTALL_STRUC - IEASTI | ISU07_INSTALL_STRUC-IEASTI | |
96 | ![]() |
ISU07_INSTALL_STRUC - IEASTS | ISU07_INSTALL_STRUC-IEASTS | |
97 | ![]() |
ISU07_INSTALL_STRUC - IETDZ | ISU07_INSTALL_STRUC-IETDZ | |
98 | ![]() |
ISU07_INSTALL_STRUC - IEZUZ | ISU07_INSTALL_STRUC-IEZUZ | |
99 | ![]() |
ISU17_EABL_OBJ - EQUNR | Equipment Number | |
100 | ![]() |
ISU17_EABL_OBJ - IEABL | ISU17_EABL_OBJ-IEABL | |
101 | ![]() |
ISU17_EABL_OBJ - IEABLG | ISU17_EABL_OBJ-IEABLG | |
102 | ![]() |
ISU17_EABL_OBJ - LOGIKZW | Logical register number | |
103 | ![]() |
ISU17_EABL_OBJ - ZWNUMMER | Register | |
104 | ![]() |
ISU17_EZWG_NEW - EQUNR | Equipment Number | |
105 | ![]() |
ISU17_EZWG_NEW - EZWG | ISU17_EZWG_NEW-EZWG | |
106 | ![]() |
ISU17_METERDOCU_MASTERDATA - IEABL | ISU17_METERDOCU_MASTERDATA-IEABL | |
107 | ![]() |
ISU17_METERDOCU_MASTERDATA - IEANL | ISU17_METERDOCU_MASTERDATA-IEANL | |
108 | ![]() |
ISU17_METERDOCU_MASTERDATA - IEASTS | ISU17_METERDOCU_MASTERDATA-IEASTS | |
109 | ![]() |
ISU17_METERDOCU_MASTERDATA - IETDZ | ISU17_METERDOCU_MASTERDATA-IETDZ | |
110 | ![]() |
ISU17_METERDOCU_MASTERDATA - IEZWG_NEW | ISU17_METERDOCU_MASTERDATA-IEZWG_NEW | |
111 | ![]() |
ISU_EE00 - KEY_LENGTH | Length of table key | |
112 | ![]() |
ISU_RANGES - LOW | ABAP/4: Selection value (LOW or HIGH value, external format) | |
113 | ![]() |
ISU_RANGES - OPTION | ABAP: Selection option (EQ/BT/CP/...) | |
114 | ![]() |
ISU_RANGES - SIGN | ABAP: ID: I/E (include/exclude values) | |
115 | ![]() |
PREVMR - PRMR_ABLR | Meter reader number | |
116 | ![]() |
PREVMR - PRMR_ADAT | Date of Previous Meter Reading for Register | |
117 | ![]() |
PREVMR - PRMR_ART | Meter reading type | |
118 | ![]() |
PREVMR - PRMR_ATIM | Meter Reading Time of Previous Meter Reading for Register | |
119 | ![]() |
PREVMR - PRMR_BELNR | Internal ID for meter reading document | |
120 | ![]() |
PREVMR - PRMR_GR | Meter reading reason | |
121 | ![]() |
PREVMR - PRMR_HINW | Note from meter reader | |
122 | ![]() |
PREVMR - PRMR_NZWAB | Decimal Places in the Billed Meter Reading | |
123 | ![]() |
PREVMR - PRMR_NZWST | Places After Decimal Point in the Meter Reading | |
124 | ![]() |
PREVMR - PRMR_STAT | Meter Reading Status | |
125 | ![]() |
PREVMR - PRMR_VZWAB | Predecimal Places in Billed Meter Reading | |
126 | ![]() |
PREVMR - PRMR_VZWST | Places Before Decimal Point in Meter Reading | |
127 | ![]() |
PREVMR - PRMR_ZWST | Previous Meter Reading Result of Register | |
128 | ![]() |
REABLD - ABLBELNR | Internal ID for meter reading document | |
129 | ![]() |
REABLD - ABLESGR | Meter reading reason | |
130 | ![]() |
REABLD - ADAT | Meter reading date relevant to billing | |
131 | ![]() |
REABLD - ADATSOLL | Scheduled meter reading date | |
132 | ![]() |
REABLD - ARBAUF | Control Meter Reading Order ID Printed | |
133 | ![]() |
REABLD - ATIM | Meter reading time (relevant to billing) | |
134 | ![]() |
REABLD - DEV_STATE | Device status | |
135 | ![]() |
REABLD - ENDBILLPER | End of billing period | |
136 | ![]() |
REABLD - EQUNR | Equipment Number | |
137 | ![]() |
REABLD - GERNR | Device | |
138 | ![]() |
REABLD - LOGIKZW | Logical register number | |
139 | ![]() |
REABLD - MASSBILL | Unit of measurement for billing | |
140 | ![]() |
REABLD - N_ZWSTAND | Places After Decimal Point in the Meter Reading | |
141 | ![]() |
REABLD - N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | |
142 | ![]() |
REABLD - PRMR_ABLR | Meter reader number | |
143 | ![]() |
REABLD - PRMR_ADAT | Date of Previous Meter Reading for Register | |
144 | ![]() |
REABLD - PRMR_ART | Meter reading type | |
145 | ![]() |
REABLD - PRMR_ATIM | Meter Reading Time of Previous Meter Reading for Register | |
146 | ![]() |
REABLD - PRMR_BELNR | Internal ID for meter reading document | |
147 | ![]() |
REABLD - PRMR_GR | Meter reading reason | |
148 | ![]() |
REABLD - PRMR_HINW | Note from meter reader | |
149 | ![]() |
REABLD - PRMR_NZWAB | Decimal Places in the Billed Meter Reading | |
150 | ![]() |
REABLD - PRMR_NZWST | Places After Decimal Point in the Meter Reading | |
151 | ![]() |
REABLD - PRMR_STAT | Meter Reading Status | |
152 | ![]() |
REABLD - PRMR_VZWAB | Predecimal Places in Billed Meter Reading | |
153 | ![]() |
REABLD - PRMR_VZWST | Places Before Decimal Point in Meter Reading | |
154 | ![]() |
REABLD - PRMR_ZWST | Previous Meter Reading Result of Register | |
155 | ![]() |
REABLD - SEGNUM | Number of SAP segment | |
156 | ![]() |
REABLD - SPARTYP | Division category | |
157 | ![]() |
REABLD - STANZNAC | Number of decimal places for register | |
158 | ![]() |
REABLD - STANZVOR | Number of predecimal places for register | |
159 | ![]() |
REABLD - V_ZWSTAND | Places Before Decimal Point in Meter Reading | |
160 | ![]() |
REABLD - V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | |
161 | ![]() |
REABLD - ZWNUMMER | Register | |
162 | ![]() |
REABLD - ZWSTAND | Meter reading recorded | |
163 | ![]() |
REG30_GERA - ACTION | Action in the work list for installation, etc. (IS-U) | |
164 | ![]() |
REGEN - KENNZX | Indicators | |
165 | ![]() |
REGEN - MAXCOUNT | Maximum number of devices to be selected | |
166 | ![]() |
REGEN - UPD_ONLINE | Update online | |
167 | ![]() |
SYST - DATUM | ABAP System Field: Current Date of Application Server | |
168 | ![]() |
SYST - TABIX | ABAP System Field: Row Index of Internal Tables | |
169 | ![]() |
SYST - UZEIT | ABAP System Field: Current Time of Application Server | |
170 | ![]() |
TE221 - MASS | Unit of Measurement | |
171 | ![]() |
TE259 - STABLHW | Control of follow-up action for MR result with MR note | |
172 | ![]() |
TE266 - GEWKEY | Weighting key | |
173 | ![]() |
TE409 - KARNEUBR | Interval days for new calculation of expected quantity | |
174 | ![]() |
TE410 - IGNESTIRESULTS | Ignore Estimated Meter Reading Results During Extrapolation | |
175 | ![]() |
TE613 - ABLESGR | Meter reading reason | |
176 | ![]() |
TE613 - ATIM | Meter reading time (relevant to billing) | |
177 | ![]() |
TE613 - BP | Selection of Billing Period: Standard or JBP | |
178 | ![]() |
TE613 - MR_PRIO | Priority of Meter Reading Reason if Times Are Same | |
179 | ![]() |
TE614 - ABLESART | Meter reading category | |
180 | ![]() |
TESPT - SPARTYP | Division category | |
181 | ![]() |
V_EANL - ANLAGE | Installation | |
182 | ![]() |
V_EGER - EQUNR | Equipment Number |