Table/Structure Field list used by SAP ABAP Function Module ISU_REGISTER_EXTRAPOLATION (INTERN: Hochrechnung eines Zählwerks)
SAP ABAP Function Module
ISU_REGISTER_EXTRAPOLATION (INTERN: Hochrechnung eines Zählwerks) is using
# | Object Type | Object Name | Object Description | Note |
---|---|---|---|---|
![]() |
![]() |
|||
1 | ![]() |
EABL - ABLBELNR | Internal ID for meter reading document | |
2 | ![]() |
EABL - ABLBELNR | Internal ID for meter reading document | SOURCE VALUE(X_ABLBELNR) LIKE EABL-ABLBELNR DEFAULT SPACE |
3 | ![]() |
EABL - ABLSTAT | Meter Reading Status | |
4 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | SOURCE VALUE(X_ABDAT) LIKE EABL-ADAT DEFAULT '00000000' |
5 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | |
6 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | SOURCE REFERENCE(Y_BEGIN_PROGINTERVALL) LIKE EABL-ADAT |
7 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | SOURCE REFERENCE(X_ADATSOLL) LIKE EABL-ADAT |
8 | ![]() |
EABL - ADAT | Meter reading date relevant to billing | SOURCE REFERENCE(Y_ENDE_PROGINTERVALL) LIKE EABL-ADAT |
9 | ![]() |
EABL - ADATREAL | [JBP] Real Meter Reading Date | |
10 | ![]() |
EABL - ADATSOLL | Scheduled meter reading date | |
11 | ![]() |
EABL - ADATSOLL | Scheduled meter reading date | SOURCE VALUE(X_SIM_OTHERDATE) LIKE EABL-ADATSOLL OPTIONAL |
12 | ![]() |
EABL - ATIM | Meter reading time (relevant to billing) | |
13 | ![]() |
EABL - ATIM | Meter reading time (relevant to billing) | SOURCE VALUE(X_ATIMSOLL) LIKE EABL-ATIM OPTIONAL |
14 | ![]() |
EABL - EQUNR | Equipment Number | |
15 | ![]() |
EABL - EQUNR | Equipment Number | SOURCE REFERENCE(X_EQUNR) LIKE EABL-EQUNR |
16 | ![]() |
EABL - GERNR | Device | |
17 | ![]() |
EABL - GERNR | Device | SOURCE VALUE(X_GERAET) LIKE EABL-GERNR OPTIONAL |
18 | ![]() |
EABL - N_ZWSTAND | Places After Decimal Point in the Meter Reading | |
19 | ![]() |
EABL - N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | |
20 | ![]() |
EABL - STANZNAC | Number of decimal places for register | SOURCE VALUE(X_STANZNAC) LIKE EABL-STANZNAC OPTIONAL |
21 | ![]() |
EABL - STANZNAC | Number of decimal places for register | |
22 | ![]() |
EABL - STANZVOR | Number of predecimal places for register | |
23 | ![]() |
EABL - STANZVOR | Number of predecimal places for register | SOURCE VALUE(X_STANZVOR) LIKE EABL-STANZVOR OPTIONAL |
24 | ![]() |
EABL - STANZVOR | Number of predecimal places for register | SOURCE REFERENCE(Y_STANZVOR) TYPE EABL-STANZVOR |
25 | ![]() |
EABL - V_ZWSTAND | Places Before Decimal Point in Meter Reading | |
26 | ![]() |
EABL - V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | |
27 | ![]() |
EABL - ZUORDDAT | Meter reading allocation date | SOURCE VALUE(X_ZUORDDAT) LIKE EABL-ZUORDDAT OPTIONAL |
28 | ![]() |
EABL - ZUORDDAT | Meter reading allocation date | |
29 | ![]() |
EABL - ZWNUMMER | Register | |
30 | ![]() |
EABL - ZWNUMMER | Register | SOURCE REFERENCE(X_ZWNUMMER) LIKE EABL-ZWNUMMER |
31 | ![]() |
EABLG - ABLBELNR | Internal ID for meter reading document | |
32 | ![]() |
EABLG - ABLESGR | Meter reading reason | SOURCE VALUE(X_ABLESGR) LIKE EABLG-ABLESGR DEFAULT SPACE |
33 | ![]() |
EABLG - ABLESGR | Meter reading reason | |
34 | ![]() |
EABLH - I_VERBERW | Expected consumption: internal format | SOURCE REFERENCE(Y_BALGESVERBERW) LIKE EABLH-I_VERBERW |
35 | ![]() |
EABLH - I_VERBERW | Expected consumption: internal format | |
36 | ![]() |
EABLH - I_VERBERW | Expected consumption: internal format | SOURCE REFERENCE(Y_VERBERW) LIKE EABLH-I_VERBERW |
37 | ![]() |
EABLH - I_ZWSTERW | Expected meter reading: internal format | |
38 | ![]() |
EABLH - I_ZWSTERW | Expected meter reading: internal format | SOURCE REFERENCE(Y_ZWSTERW) LIKE EABLH-I_ZWSTERW |
39 | ![]() |
EABL_JBP - ADATREAL | [JBP] Real Meter Reading Date | |
40 | ![]() |
EADZ - PROFEST | Consumption fixed value to be weighted linearly | |
41 | ![]() |
EADZ - PROPROZ | Consumption percentage for weighting | |
42 | ![]() |
EADZ - ZEITRAUM | Validity period | |
43 | ![]() |
EANL - ANLAGE | Installation | SOURCE VALUE(X_ANLAGE) LIKE EANL-ANLAGE OPTIONAL |
44 | ![]() |
EANL - ANLAGE | Installation | |
45 | ![]() |
EANL - BAPERTYP | Base period category | |
46 | ![]() |
EANL - BAPERTYP | Base period category | SOURCE VALUE(XY_BAPERTYP) LIKE EANL-BAPERTYP OPTIONAL |
47 | ![]() |
EANLDATA - BAPERTYP | Base period category | |
48 | ![]() |
EANLDATA - BAPERTYP | Base period category | SOURCE VALUE(XY_BAPERTYP) LIKE EANL-BAPERTYP OPTIONAL |
49 | ![]() |
EANLDATASAP - BAPERTYP | Base period category | |
50 | ![]() |
EANLDATASAP - BAPERTYP | Base period category | SOURCE VALUE(XY_BAPERTYP) LIKE EANL-BAPERTYP OPTIONAL |
51 | ![]() |
EANLKEY - ANLAGE | Installation | SOURCE VALUE(X_ANLAGE) LIKE EANL-ANLAGE OPTIONAL |
52 | ![]() |
EANLKEY - ANLAGE | Installation | |
53 | ![]() |
EASTE - AB | Start date for consumption period | |
54 | ![]() |
EASTE - BIS | Date at Which a Time Slice Expires | |
55 | ![]() |
EASTE - PERVERBR | Period Consumption | |
56 | ![]() |
EASTS - ANLAGE | Installation | |
57 | ![]() |
EJBP - BP | Selection of Billing Period: Standard or JBP | |
58 | ![]() |
EMSG_GEN - MSGID | Message Class | |
59 | ![]() |
EMSG_GEN - MSGNO | Message Number | |
60 | ![]() |
EMSG_GEN - MSGTY | Message type | |
61 | ![]() |
EMSG_GEN - OKCODE | OK code for message object | |
62 | ![]() |
EMSG_MSG - KZ_BREAK | Indicator: Breakpoint | |
63 | ![]() |
EMSG_MSG - KZ_EXC | Indicator: Output EXCEPTION | |
64 | ![]() |
EMSG_MSG - KZ_MSG | Indicator: Output message | |
65 | ![]() |
EMSG_MSG - MSGID | Message Class | |
66 | ![]() |
EMSG_MSG - MSGNO | Message Number | |
67 | ![]() |
EMSG_MSG - MSGTY | Message Type | |
68 | ![]() |
EMSG_MSG - MSGV1 | Message Variable | |
69 | ![]() |
EMSG_MSG - MSGV2 | Message Variable | |
70 | ![]() |
EMSG_MSG - MSGV3 | Message Variable | |
71 | ![]() |
EMSG_MSG - MSGV4 | Message Variable | |
72 | ![]() |
ES31GEN - EANLDISCST | Disconnection status of an installation | |
73 | ![]() |
ETDZ - LOGIKZW | Logical register number | |
74 | ![]() |
ETDZ - LOGIKZW | Logical register number | SOURCE VALUE(X_LOGIKZW) LIKE ETDZ-LOGIKZW OPTIONAL |
75 | ![]() |
ETDZ - LOGIKZW | Logical register number | SOURCE REFERENCE(Y_LOGIKZW) TYPE ETDZ-LOGIKZW |
76 | ![]() |
ETDZ - SPARTYP | Division category | |
77 | ![]() |
ETDZ - STEUERGRP | Control group for multiple meter reading order creation | |
78 | ![]() |
ETDZ - TEMP_AREA | Temperature area | |
79 | ![]() |
ETDZ - ZWTYP | Register category | |
80 | ![]() |
ETDZ_LOC - TEMP_AREA | Temperature area | |
81 | ![]() |
ETFND - TARIFNR | Rate key | |
82 | ![]() |
ETFND - TARIFNR | Rate key | SOURCE VALUE(X_TARIFNR) LIKE ETFND-TARIFNR OPTIONAL |
83 | ![]() |
ETRF - MINPROZ | Minimum portion in percent | |
84 | ![]() |
ETRF - MINPROZ | Minimum portion in percent | SOURCE VALUE(X_MINPROZ) TYPE ETRF-MINPROZ OPTIONAL |
85 | ![]() |
ETRF - OPERAND | Register operand in rate | SOURCE VALUE(X_OPERAND) LIKE ETRF-OPERAND OPTIONAL |
86 | ![]() |
ETRF - OPERAND | Register operand in rate | |
87 | ![]() |
EVER - EINZDAT | Move-In Date | |
88 | ![]() |
EVERU - EINZDAT | Move-In Date | |
89 | ![]() |
EZUZ - ABRFAKT | Billing factor | SOURCE VALUE(X_ABRFAKT) LIKE EZUZ-ABRFAKT OPTIONAL |
90 | ![]() |
EZUZ - ABRFAKT | Billing factor | |
91 | ![]() |
EZWG - ZWTYP | Register category | |
92 | ![]() |
ISU17_INTERFACE_STRUCTURES - EABL_PROVIDED | Indicators | |
93 | ![]() |
ISU17_INTERFACE_STRUCTURES - EASTL | ISU17_INTERFACE_STRUCTURES-EASTL | |
94 | ![]() |
ISU17_INTERFACE_STRUCTURES - EASTL_PROVIDED | Indicators | |
95 | ![]() |
ISU17_INTERFACE_STRUCTURES - ETDZ_PROVIDED | Indicators | |
96 | ![]() |
ISU17_INTERFACE_STRUCTURES - EZUZ_PROVIDED | Indicators | |
97 | ![]() |
REA00 - BREAK | Description of breakpoint in billing program | |
98 | ![]() |
REA00 - BREAK | Description of breakpoint in billing program | SOURCE VALUE(XY_BP) LIKE REA00-BREAK OPTIONAL |
99 | ![]() |
REABLD - DEV_STATE | Device status | |
100 | ![]() |
REABLD - DEV_STATE | Device status | SOURCE VALUE(X_DEV_STATE) LIKE REABLD-DEV_STATE OPTIONAL |
101 | ![]() |
REGEN - DB_UPDATE | Database updated (x) or not (SPACE) | |
102 | ![]() |
REGEN - KENNZX | Indicators | SOURCE VALUE(X_ACTUAL) LIKE REGEN-KENNZX OPTIONAL |
103 | ![]() |
REGEN - KENNZX | Indicators | |
104 | ![]() |
REGEN - KENNZX | Indicators | SOURCE VALUE(X_HERKUNFT) LIKE REGEN-KENNZX DEFAULT SPACE |
105 | ![]() |
REGEN - KENNZX | Indicators | SOURCE VALUE(X_IGN_INCORR_MR) LIKE REGEN-KENNZX DEFAULT SPACE |
106 | ![]() |
REGEN - KENNZX | Indicators | SOURCE VALUE(X_BILA) LIKE REGEN-KENNZX DEFAULT SPACE |
107 | ![]() |
REGEN - KENNZX | Indicators | SOURCE VALUE(X_READ_ALL_EABL) LIKE REGEN-KENNZX DEFAULT SPACE |
108 | ![]() |
REGEN - KENNZX | Indicators | SOURCE VALUE(X_REKURSIV) LIKE REGEN-KENNZX DEFAULT SPACE |
109 | ![]() |
REGEN - KENNZX | Indicators | SOURCE VALUE(X_SPEZVERF) LIKE REGEN-KENNZX DEFAULT SPACE |
110 | ![]() |
REGEN - KENNZX | Indicators | SOURCE REFERENCE(Y_BAL_AND_ZVBL) LIKE REGEN-KENNZX |
111 | ![]() |
REGEN - MAXCOUNT | Maximum number of devices to be selected | |
112 | ![]() |
REGEN - UPD_ONLINE | Update online | |
113 | ![]() |
REL01 - ALLE_EABL | Selection | |
114 | ![]() |
REL01 - ALLE_EABL | Selection | SOURCE REFERENCE(Y_COMP_BY_EABL) LIKE REL01-ALLE_EABL |
115 | ![]() |
REL01 - ALLE_EABL | Selection | SOURCE REFERENCE(Y_COMP_BY_PERVERB) LIKE REL01-ALLE_EABL |
116 | ![]() |
REL01 - ALLE_EABL | Selection | SOURCE REFERENCE(Y_COMP_BY_REFVAL) LIKE REL01-ALLE_EABL |
117 | ![]() |
REL01 - ALLE_EABL | Selection | SOURCE REFERENCE(Y_TYPE_OF_EXTRAPOLATION) LIKE REL01-ALLE_EABL |
118 | ![]() |
REL01 - ALLE_EABL | Selection | SOURCE REFERENCE(Y_COMP_BY_CUSTOMER) LIKE REL01-ALLE_EABL |
119 | ![]() |
SYST - MSGV1 | ABAP System Field: Message Variable | |
120 | ![]() |
SYST - MSGV2 | ABAP System Field: Message Variable | |
121 | ![]() |
SYST - MSGV3 | ABAP System Field: Message Variable | |
122 | ![]() |
SYST - MSGV4 | ABAP System Field: Message Variable | |
123 | ![]() |
SYST - TABIX | ABAP System Field: Row Index of Internal Tables | |
124 | ![]() |
TE221 - MASS | Unit of Measurement | SOURCE REFERENCE(Y_MASS) TYPE TE221-MASS |
125 | ![]() |
TE221 - MASS | Unit of Measurement | SOURCE VALUE(X_MASS) LIKE TE221-MASS OPTIONAL |
126 | ![]() |
TE221 - MASS | Unit of Measurement | |
127 | ![]() |
TE266 - GEWKEY | Weighting key | |
128 | ![]() |
TE266 - GEWKEY | Weighting key | SOURCE VALUE(X_GEWKEY) LIKE TE266-GEWKEY OPTIONAL |
129 | ![]() |
TE266 - GEWVERF | Weighting procedures | |
130 | ![]() |
TE411 - LEISTMS | Estimation of watt and resetting registers | |
131 | ![]() |
TE422 - PERIODEW | Period length: months | SOURCE VALUE(X_ANZMON) LIKE TE422-PERIODEW OPTIONAL |
132 | ![]() |
TE422 - PERIODEW | Period length: months | SOURCE VALUE(X_ANZPER) LIKE TE422-PERIODEW DEFAULT 1 |
133 | ![]() |
TE422 - PERIODEW | Period length: months | |
134 | ![]() |
TE629 - KENNZ1 | No subperiodic meter reading | |
135 | ![]() |
TE629 - ZVRSZWUE | MR orders for periodic MR of resetting registers | |
136 | ![]() |
V_EGER - GERAET | Serial Number | |
137 | ![]() |
V_EGER - LOGIKNR | Logical device number | |
138 | ![]() |
V_EGER - LOGIKNR | Logical device number | SOURCE VALUE(X_LOGIKNR) LIKE V_EGER-LOGIKNR OPTIONAL |