Table list used by SAP ABAP Function Module ISU_O_CS_METERREAD_OPEN (INTERN: Eröffnet die AuftrErstellg u. Erfassung für eine Menge von Anlagen)
SAP ABAP Function Module
ISU_O_CS_METERREAD_OPEN (INTERN: Eröffnet die AuftrErstellg u. Erfassung für eine Menge von Anlagen) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | EABL | MR Document | ||
| 2 | EABLG | MR Reasons in MR Document | ||
| 3 | EABLH | Help Fields for meter reading data | ||
| 4 | EMIO_MR_CONTRACT | Meter Reading Data Obj. for Move-In/Move-Out: Contract Data | ||
| 5 | EMIO_MR_CONTR_EXT | Meter Read. Data Obj. for Move-In/Move-Out: Ext.Control Data | ||
| 6 | EMIO_MR_CONTR_EXT | Meter Read. Data Obj. for Move-In/Move-Out: Ext.Control Data | SOURCE REFERENCE(X_CONTR_EXT) TYPE EMIO_MR_CONTR_EXT OPTIONAL |
|
| 7 | EMSG_MSG | Int. Structure for Macros | ||
| 8 | EVER | IS-U Cont. | ||
| 9 | ISU17_METERREAD_AUTO | Automation Data for Meter Reading | ||
| 10 | ISU_RANGES | Structure: Select Options | ||
| 11 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_NO_BILLORDER) LIKE REGEN-KENNZX OPTIONAL |
|
| 12 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_WMODE) LIKE REGEN-WMODE |
|
| 13 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_NO_DIALOG) LIKE REGEN-NO_DIALOG |
|
| 14 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_SUPPRESS_PREPARATION) LIKE REGEN-KENNZX OPTIONAL |
|
| 15 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_FORCE_DELAYED_SVC) LIKE REGEN-KENNZX OPTIONAL |
|
| 16 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_NO_PROPOSAL) LIKE REGEN-KENNZX OPTIONAL |
|
| 17 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_NO_ENTRY_OF_READINGS) LIKE REGEN-KENNZX OPTIONAL |
|
| 18 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_NO_BILLORDER_CREATE) LIKE REGEN-KENNZX OPTIONAL |
|
| 19 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_BAPI) LIKE REGEN-KENNZX OPTIONAL |
|
| 20 | REGEN | General Fields for IS-U Function Module Interfaces | SOURCE VALUE(X_FORCE_SVC) LIKE REGEN-KENNZX OPTIONAL |
|
| 21 | REGEN | General Fields for IS-U Function Module Interfaces | ||
| 22 | TE400 | Controls for Meter Reading Order Creation/Entry | ||
| 23 | TE490ES | General System Parameters for Move-In and Move-Out | SOURCE REFERENCE(X_TE490ES) TYPE TE490ES OPTIONAL |
|
| 24 | TE490ES | General System Parameters for Move-In and Move-Out | ||
| 25 | TE609 | MR Reasons (Values) | SOURCE VALUE(X_ABLESGR) LIKE TE609-ABLESGR |