Table/Structure Field list used by SAP ABAP Function Module ISU_ANALYZE_REPRESENTATION (INTERN: Prüfung, ab wann die Representativität von Ablesungen beginnt)
SAP ABAP Function Module
ISU_ANALYZE_REPRESENTATION (INTERN: Prüfung, ab wann die Representativität von Ablesungen beginnt) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | EABL - ADAT | Meter reading date relevant to billing | SOURCE REFERENCE(X_ADAT) LIKE EABL-ADAT |
|
| 2 | EABL - ADAT | Meter reading date relevant to billing | SOURCE REFERENCE(Y_BEGIN_REPRESENTATIVITY) LIKE EABL-ADAT |
|
| 3 | EABL - ZWNUMMER | Register | ||
| 4 | EABL - ZWNUMMER | Register | SOURCE REFERENCE(X_ZWNUMMER) LIKE EABL-ZWNUMMER |
|
| 5 | EABL - EQUNR | Equipment Number | ||
| 6 | EABL - ADAT | Meter reading date relevant to billing | ||
| 7 | EABL - EQUNR | Equipment Number | SOURCE REFERENCE(X_EQUNR) LIKE EABL-EQUNR |
|
| 8 | EABLH - I_VERBERW | Expected consumption: internal format | ||
| 9 | EANL - ANLAGE | Installation | ||
| 10 | EANL - ANLAGE | Installation | SOURCE VALUE(X_ANLAGE) LIKE EANL-ANLAGE OPTIONAL |
|
| 11 | EANLKEY - ANLAGE | Installation | SOURCE VALUE(X_ANLAGE) LIKE EANL-ANLAGE OPTIONAL |
|
| 12 | EANLKEY - ANLAGE | Installation | ||
| 13 | EASTS - ANLAGE | Installation | ||
| 14 | EASTS - TARIFART | Rate Type | ||
| 15 | EMSG_GEN - MSGTY | Message type | ||
| 16 | EMSG_MSG - KZ_BREAK | Indicator: Breakpoint | ||
| 17 | EMSG_MSG - MSGV4 | Message Variable | ||
| 18 | EMSG_MSG - MSGV3 | Message Variable | ||
| 19 | EMSG_MSG - MSGV2 | Message Variable | ||
| 20 | EMSG_MSG - MSGV1 | Message Variable | ||
| 21 | EMSG_MSG - MSGTY | Message Type | ||
| 22 | EMSG_MSG - MSGNO | Message Number | ||
| 23 | EMSG_MSG - MSGID | Message Class | ||
| 24 | EMSG_MSG - KZ_MSG | Indicator: Output message | ||
| 25 | EMSG_MSG - KZ_EXC | Indicator: Output EXCEPTION | ||
| 26 | ERTFND - TARIFNR | Rate key | ||
| 27 | ES31GEN - EANLDISCST | Disconnection status of an installation | ||
| 28 | ETDZ - LOGIKZW | Logical register number | ||
| 29 | ETDZ - LOGIKZW | Logical register number | SOURCE VALUE(X_LOGIKZW) LIKE ETDZ-LOGIKZW OPTIONAL |
|
| 30 | ETDZ - SPARTYP | Division category | ||
| 31 | ETDZ - TEMP_AREA | Temperature area | ||
| 32 | ETDZ - ZWTYP | Register category | ||
| 33 | ETDZ_LOC - TEMP_AREA | Temperature area | ||
| 34 | ETRF - MINPROZ | Minimum portion in percent | ||
| 35 | EZWG - ZWTYP | Register category | ||
| 36 | REA00 - BREAK | Description of breakpoint in billing program | ||
| 37 | REA00 - BREAK | Description of breakpoint in billing program | SOURCE VALUE(XY_BP) LIKE REA00-BREAK OPTIONAL |
|
| 38 | REGEN - MAXCOUNT | Maximum number of devices to be selected | ||
| 39 | REGEN - UPD_ONLINE | Update online | ||
| 40 | REGEN - KENNZX | Indicators | ||
| 41 | SYST - TABIX | ABAP System Field: Row Index of Internal Tables | ||
| 42 | TE265 - GEWVERF | Weighting procedures | ||
| 43 | TE266 - GEWKEY | Weighting key | ||
| 44 | TE266 - GEWVERF | Weighting procedures | ||
| 45 | TE420 - PERIODED | Period length in days | ||
| 46 | TE422 - PERIODEW | Period length: months | ||
| 47 | V_EANL - ABLEINH | Meter reading unit | ||
| 48 | V_EANL - TARIFTYP | Rate category | ||
| 49 | V_EANL - TEMP_AREA | Temperature area | ||
| 50 | V_EGER - GERAET | Serial Number | ||
| 51 | V_EGER - LOGIKNR | Logical device number |