Table/Structure Field list used by SAP ABAP Function Module DPWTY_HD_MWARRANTY_CHECK_SIMU (Check master warranty header object without measure doc. only claim values)
SAP ABAP Function Module
DPWTY_HD_MWARRANTY_CHECK_SIMU (Check master warranty header object without measure doc. only claim values) is using
# | Object Type | Object Name | Object Description | Note |
---|---|---|---|---|
![]() |
![]() |
|||
1 | ![]() |
BAPIRET2 - MESSAGE | Message Text | |
2 | ![]() |
BGMS - MGANR | Master warranty number | |
3 | ![]() |
BGMS - POSNM | Warranty item number | |
4 | ![]() |
BGMS - POSTX | Text, length 40 | |
5 | ![]() |
BGMS - SPRAS | Language Key | |
6 | ![]() |
BGMZ - GAZNA | Warranty counter | |
7 | ![]() |
BGMZ - MGANR | Master warranty number | |
8 | ![]() |
BGMZ - POSNM | Warranty item number | |
9 | ![]() |
DPWTY_S_MGANR - GAART | Warranty Type | |
10 | ![]() |
DPWTY_S_MGANR - GAKTX | Text, length 40 | |
11 | ![]() |
DPWTY_S_MGANR - GWLDT | Start Date of Assigned Warranty | |
12 | ![]() |
DPWTY_S_MGANR - MGANR | Master warranty number | |
13 | ![]() |
DPWTY_S_MGANR - MGPOS | DPWTY_S_MGANR-MGPOS | |
14 | ![]() |
DPWTY_S_MGANR_POS - LVORM | Deletion Indicator | |
15 | ![]() |
DPWTY_S_MGANR_POS - MGANR | Master warranty number | |
16 | ![]() |
DPWTY_S_MGANR_POS - POSNM | Warranty item number | |
17 | ![]() |
IMPTT - ATINN | Internal characteristic | |
18 | ![]() |
IMPTT - POINT | Measuring Point | |
19 | ![]() |
PNWTYH - PNGUID | Internal Number of iPPE Node | |
20 | ![]() |
PNWTYH - REFDT | Reference Date | |
21 | ![]() |
PNWTYH - RELOB | Internal Object Number | |
22 | ![]() |
PNWTYH - RELOB_EXT | External Object Number | |
23 | ![]() |
PNWTYH - RELTY | Type of Warranty Object | |
24 | ![]() |
PNWTYH - RESULT_IN_MWTY | Result of Warranty Check for Object (Vendor) | |
25 | ![]() |
PNWTYH - RESULT_OUT_MWTY | Result of Object Warranty Check (Customer) | |
26 | ![]() |
PNWTYH - SERNO | Serial Number | |
27 | ![]() |
PNWTYHD - REFDT | Reference Date | |
28 | ![]() |
PNWTYHD - RELOB | Internal Object Number | |
29 | ![]() |
PNWTYHD - RELOB_EXT | External Object Number | |
30 | ![]() |
PNWTYHD - RELTY | Type of Warranty Object | |
31 | ![]() |
PNWTYHD - RESULT_IN_MWTY | Result of Warranty Check for Object (Vendor) | |
32 | ![]() |
PNWTYHD - RESULT_OUT_MWTY | Result of Object Warranty Check (Customer) | |
33 | ![]() |
PNWTYHD - SERNO | Serial Number | |
34 | ![]() |
PNWTYV - PNGUID | Internal Number of iPPE Node | |
35 | ![]() |
SYST - DATUM | ABAP System Field: Current Date of Application Server | |
36 | ![]() |
SYST - LANGU | ABAP System Field: Language Key of Text Environment | |
37 | ![]() |
T006A - MSEH6 | External Unit of Measurement in Technical Format (6-Char.) | |
38 | ![]() |
T006A - MSEHI | Unit of Measurement | |
39 | ![]() |
T006A - SPRAS | Language Key | |
40 | ![]() |
T790G_T - GAART | Warranty type | |
41 | ![]() |
T790G_T - KTEXT | Text, length 40 | |
42 | ![]() |
T790G_T - LANGU | Language Key | |
43 | ![]() |
T791Z - GAZNA | Warranty counter | |
44 | ![]() |
T791Z - KZKAL | Indicator: Calendar time | |
45 | ![]() |
WTYV_IMRG_DIA - LAST_MEASUREMENT | Last Meas. Read. for Distance Covered by Reference Object | |
46 | ![]() |
WTYV_IMRG_DIA - LAST_MEASUREM_UNIT | Unit of Measurement | |
47 | ![]() |
WTYV_IMRG_DIA - MSEH6 | External Unit of Measurement in Technical Format (6-Char.) | |
48 | ![]() |
WTYV_IMRG_DIA - MSEHI | Unit of Measurement | |
49 | ![]() |
WTYV_IMRG_DIA - POINT | Measuring Point | |
50 | ![]() |
WTYV_IMRG_DYN - LAST_MEASUREMENT | Last Meas. Read. for Distance Covered by Reference Object | |
51 | ![]() |
WTYV_IMRG_DYN - LAST_MEASUREM_UNIT | Unit of Measurement | |
52 | ![]() |
WTY_CHECK_ADD_INFO - CHECK_DATE | Date on Which Warranty is Checked | |
53 | ![]() |
WTY_CHECK_ADD_INFO - EQART | Type of Technical Object | |
54 | ![]() |
WTY_CHECK_ADD_INFO - GAATX | Description for Warranty Type | |
55 | ![]() |
WTY_CHECK_ADD_INFO - GAKTX | Description of Master Warranty | |
56 | ![]() |
WTY_CHECK_ADD_INFO - OBJKEY | Key of Checked Object | |
57 | ![]() |
WTY_CHECK_ADD_INFO - OBJTX | Descriptive Text for Checked Object | |
58 | ![]() |
WTY_CHECK_ADD_INFO - POSTX | Description for Master Warranty Item | |
59 | ![]() |
WTY_CHECK_ADD_INFO - RELTY | Type of Warranty Object | |
60 | ![]() |
WTY_CHECK_OBJECT - C_RESULT_OBJ | Warranty Check Result by Counter | |
61 | ![]() |
WTY_MWARRANTY - CHECK_ICON | Icon for Warranty Check Result | |
62 | ![]() |
WTY_MWARRANTY - CHECK_RESULT | Result of Warranty Check for each Warranty | |
63 | ![]() |
WTY_MWARRANTY - GAATX | Description for Warranty Type | |
64 | ![]() |
WTY_MWARRANTY - GAKTX | Description of Master Warranty | |
65 | ![]() |
WTY_MWARRANTY - GWLDT | Start Date of Assigned Warranty | |
66 | ![]() |
WTY_MWARRANTY - OBJKEY | Key of Checked Object | |
67 | ![]() |
WTY_MWARRANTY - OBJNR | Object number | |
68 | ![]() |
WTY_MWARRANTY - OBJTX | Descriptive Text for Checked Object | |
69 | ![]() |
WTY_PNWTYH_DIA - EQUNR | Equipment Number | |
70 | ![]() |
WTY_PNWTYH_DIA - MODTX | Description of Model / Object | |
71 | ![]() |
WTY_PNWTYH_DIA - OBJCT_TXT | Description of Model / Object | |
72 | ![]() |
WTY_PNWTYH_DIA - PNGUID | Internal Number of iPPE Node | |
73 | ![]() |
WTY_PNWTYH_DIA - REFDT | Reference Date | |
74 | ![]() |
WTY_PNWTYH_DIA - RELOB | Internal Object Number | |
75 | ![]() |
WTY_PNWTYH_DIA - RELOB_EXT | External Object Number | |
76 | ![]() |
WTY_PNWTYH_DIA - RELTY | Type of Warranty Object | |
77 | ![]() |
WTY_PNWTYH_DIA - RESULT_IN_MWTY | Result of Warranty Check for Object (Vendor) | |
78 | ![]() |
WTY_PNWTYH_DIA - RESULT_OUT_MWTY | Result of Object Warranty Check (Customer) | |
79 | ![]() |
WTY_PNWTYH_DIA - SERNO | Serial Number | |
80 | ![]() |
WTY_PNWTYH_DYN - EQUNR | Equipment Number | |
81 | ![]() |
WTY_PNWTYH_DYN - MODTX | Description of Model / Object | |
82 | ![]() |
WTY_PNWTYH_DYN - OBJCT_TXT | Description of Model / Object | |
83 | ![]() |
WTY_PNWTYH_DYN_EXT - EQUNR | Equipment Number | |
84 | ![]() |
WTY_PNWTYH_DYN_EXT - MODTX | Description of Model / Object | |
85 | ![]() |
WTY_PNWTYH_DYN_EXT - OBJCT_TXT | Description of Model / Object | |
86 | ![]() |
WTY_PNWTYV_EXT - LAST_MEASUREMENT | Last Meas. Read. for Distance Covered by Reference Object | |
87 | ![]() |
WTY_PNWTYV_EXT - LAST_MEASUREM_UNIT | Unit of Measurement | |
88 | ![]() |
WTY_RESULT_COUNTER - CHECK_DATE | Date on Which Warranty is Checked | |
89 | ![]() |
WTY_RESULT_COUNTER - EQART | Type of Technical Object | |
90 | ![]() |
WTY_RESULT_COUNTER - GAATX | Description for Warranty Type | |
91 | ![]() |
WTY_RESULT_COUNTER - J_OBJNR | Object Number for Status Management | |
92 | ![]() |
WTY_RESULT_COUNTER - MGANR | Master Warranty | |
93 | ![]() |
WTY_RESULT_COUNTER - OBJTX | Descriptive Text for Checked Object | |
94 | ![]() |
WTY_RESULT_COUNTER - POSTX | Description for Master Warranty Item | |
95 | ![]() |
WTY_RESULT_COUNTER - RELTY | Type of Warranty Object | |
96 | ![]() |
WTY_RESULT_KEY - J_OBJNR | Object Number for Status Management | |
97 | ![]() |
WTY_RESULT_KEY - MGANR | Master Warranty | |
98 | ![]() |
WTY_RESULT_OBJECT - C_RESULT_OBJ | Warranty Check Result by Counter | |
99 | ![]() |
WTY_RESULT_OBJECT - MGANR | Master Warranty | |
100 | ![]() |
WTY_RIFLTCOUN - MSEH6 | External Unit of Measurement in Technical Format (6-Char.) | |
101 | ![]() |
WTY_RIFLTCOUN - MSEHI | Unit of Measurement | |
102 | ![]() |
WTY_RIFLTCOUN - POINT | Measuring Point | |
103 | ![]() |
WTY_VERS_RIFLTCOUN - MSEH6 | External Unit of Measurement in Technical Format (6-Char.) | |
104 | ![]() |
WTY_VERS_RIFLTCOUN - MSEHI | Unit of Measurement | |
105 | ![]() |
WTY_VERS_RIFLTCOUN - POINT | Measuring Point | |
106 | ![]() |
WTY_VERS_RIFLTCOUN - PSORT | Item Number of Measuring Point of Object (Sort Field) | |
107 | ![]() |
WTY_VERS_RIFLTCOUN - RECNT | Counter Reading in Entry Unit |