Class Method list used by SAP ABAP Class CL_ILM_ARC_WRI_VARIANT_FEEDER (Feeder Class for File Details)
SAP ABAP Class
CL_ILM_ARC_WRI_VARIANT_FEEDER (Feeder Class for File Details) is using
# | Object Type | Object Name | Object Description | Note |
---|---|---|---|---|
![]() |
![]() |
|||
1 | ![]() |
CL_ABAP_STRUCTDESCR - GET_COMPONENTS | Runtime Type Services | |
2 | ![]() |
CL_ABAP_TYPEDESCR - DESCRIBE_BY_NAME | Runtime Type Services | |
3 | ![]() |
CL_ARC_DAS_ROUT_ADK - CONSTRUCTOR | DAS Connector for ADK: IRM Connection | |
4 | ![]() |
CL_ARC_DAS_ROUT_ADK - GET_ILM_USAGE | DAS Connector for ADK: IRM Connection | |
5 | ![]() |
CL_FPM_CONFIRMATION_REQUEST - CONSTRUCTOR | Requests an end-user confirmation (e.g. data loss warning) | |
6 | ![]() |
CL_FPM_FACTORY - GET_INSTANCE | Factory to provide an instance of interface IF_FPM_API | |
7 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_AO | Central Data Retention for Archiving Work Center | |
8 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - NAVIGATE_TO_MAINTAIN_VARIANT | Central Data Retention for Archiving Work Center | |
9 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_SESSION_DETAILS | Central Data Retention for Archiving Work Center | |
10 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_INSTANCE | Central Data Retention for Archiving Work Center | |
11 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_AO | Central Data Retention for Archiving Work Center | |
12 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_AO | Central Data Retention for Archiving Work Center | |
13 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_AO | Central Data Retention for Archiving Work Center | |
14 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_AO | Central Data Retention for Archiving Work Center | |
15 | ![]() |
CL_ILM_ARC_CENTRAL_DATA - GET_AO | Central Data Retention for Archiving Work Center | |
16 | ![]() |
CL_ILM_ARC_VARIANT - VARIANT_SUPPORTS_ACTION | Services for Variants | |
17 | ![]() |
CL_ILM_ARC_VARIANT - VARIANT_USED_IN_ARCH_JOBS | Services for Variants | |
18 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - SET_PARAM_VISIBILITY | Feeder Class for File Details | SOURCE set_param_visibility( |
19 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - SET_PARAM_VISIBILITY | Feeder Class for File Details | SOURCE cs_ilm_create_data = |
20 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - SET_PARAM_VISIBILITY | Feeder Class for File Details | SOURCE CHANGING |
21 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - SET_PARAM_VISIBILITY | Feeder Class for File Details | SOURCE iv_variant_exists = lv_variant_exists |
22 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - SET_PARAM_VISIBILITY | Feeder Class for File Details | SOURCE EXPORTING |
23 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - GET_INCOMPLETE_INTERRUPT_MSG | Feeder Class for File Details | SOURCE APPEND LINES OF get_incomplete_interrupt_msg( ) TO et_messages. |
24 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - GET_INCLUDE_TYPE | Feeder Class for File Details | SOURCE IF iv_variant_exists = abap_false OR get_include_type( ) = mc_include_none. |
25 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - GET_INCLUDE_TYPE | Feeder Class for File Details | SOURCE CHECK get_include_type( ) <> mc_include_none. "<<===============CHECK |
26 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - FILL_TECH_DATA_FROM_VARIANT | Feeder Class for File Details | SOURCE cs_ilm_create_data = |
27 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - FILL_TECH_DATA_FROM_VARIANT | Feeder Class for File Details | SOURCE CHANGING |
28 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - FILL_TECH_DATA_FROM_VARIANT | Feeder Class for File Details | SOURCE fill_tech_data_from_variant( |
29 | ![]() |
CL_ILM_ARC_WRI_VARIANT_FEEDER - GET_INCLUDE_TYPE | Feeder Class for File Details | SOURCE IF get_include_type( ) = mc_include_1. |
30 | ![]() |
IF_FPM - OPEN_DIALOG_BOX | Interface for accessing FPM functionality | |
31 | ![]() |
IF_FPM_GUIBB - GET_PARAMETER_LIST | Generic UI Building Block | |
32 | ![]() |
IF_FPM_GUIBB - INITIALIZE | Generic UI Building Block | |
33 | ![]() |
IF_FPM_GUIBB_FORM - GET_DEFAULT_CONFIG | Generic Form UI Building Block | |
34 | ![]() |
IF_FPM_GUIBB_FORM - PROCESS_EVENT | Generic Form UI Building Block | |
35 | ![]() |
IF_FPM_GUIBB_FORM - GET_DEFINITION | Generic Form UI Building Block | |
36 | ![]() |
IF_FPM_GUIBB_FORM - GET_DATA | Generic Form UI Building Block | |
37 | ![]() |
IF_FPM_GUIBB_FORM - FLUSH | Generic Form UI Building Block | |
38 | ![]() |
IF_FPM_GUIBB_FORM - CHECK_CONFIG | Generic Form UI Building Block | |
39 | ![]() |
IF_FPM_GUIBB_FORM_EXT - AFTER_FAILED_EVENT | GUIBB Form extended | |
40 | ![]() |
IF_FPM_GUIBB_FORM_EXT - BEFORE_DISPATCH_EVENT | GUIBB Form extended | |
41 | ![]() |
IF_FPM_GUIBB_FORM_EXT - NEEDS_CONFIRMATION | GUIBB Form extended | |
42 | ![]() |
IF_ILM_AO - GET_ARCH_OBJ | Interface Archiving Object | |
43 | ![]() |
IF_ILM_AO - GET_ARCH_OBJ | Interface Archiving Object | |
44 | ![]() |
IF_ILM_AO - GET_ARCH_OBJ | Interface Archiving Object | |
45 | ![]() |
IF_ILM_AO - GET_ARCH_OBJ | Interface Archiving Object | |
46 | ![]() |
IF_ILM_AO - GET_ARCH_OBJ | Interface Archiving Object | |
47 | ![]() |
IF_ILM_AO - GET_ARCH_OBJ | Interface Archiving Object | |
48 | ![]() |
IF_ILM_AO - GET_ARCH_USR | Interface Archiving Object |