Class Method list used by SAP ABAP Class CL_EAMS_UI_FD_MP_INIT (WD feeder for measuring point initial screen)
SAP ABAP Class
CL_EAMS_UI_FD_MP_INIT (WD feeder for measuring point initial screen) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | /PLMU/CL_FRW_FACTORY - GET_BASIC_APPLICATION_MODEL | Factory Class | ||
| 2 | /PLMU/IF_FRW_BASIC_APPL_MODEL - ACTION | Basic Application Model | ||
| 3 | /PLMU/IF_FRW_BASIC_APPL_MODEL - UPDATE | Basic Application Model | ||
| 4 | /PLMU/IF_FRW_BASIC_APPL_MODEL - RETRIEVE | Basic Application Model | ||
| 5 | /PLMU/IF_FRW_BASIC_APPL_MODEL - RETRIEVE | Basic Application Model | ||
| 6 | /PLMU/IF_FRW_BASIC_APPL_MODEL - ACTION | Basic Application Model | ||
| 7 | /PLMU/IF_FRW_BASIC_APPL_MODEL - ACTION | Basic Application Model | ||
| 8 | /PLMU/IF_FRW_BASIC_APPL_MODEL - ACTION | Basic Application Model | ||
| 9 | /PLMU/IF_FRW_CONTEXT - GET_ROW | Context | ||
| 10 | /PLMU/IF_FRW_CONTEXT - GET_ROW | Context | ||
| 11 | /PLMU/IF_FRW_CONTEXT - GET_ROW | Context | ||
| 12 | /PLMU/IF_FRW_CONTEXT - GET_ROW | Context | ||
| 13 | /PLMU/IF_FRW_CONTEXT - GET_ROW | Context | ||
| 14 | /PLMU/IF_FRW_CONTEXT - SET_ROW | Context | ||
| 15 | /PLMU/IF_FRW_CONTEXT - SET_ROW | Context | ||
| 16 | /PLMU/IF_FRW_C_APPL_MODEL - ACTION | Context Dependent Application Model | ||
| 17 | /PLMU/IF_FRW_C_APPL_MODEL - UPDATE | Context Dependent Application Model | ||
| 18 | /PLMU/IF_FRW_C_APPL_MODEL - RETRIEVE | Context Dependent Application Model | ||
| 19 | /PLMU/IF_FRW_C_APPL_MODEL - RETRIEVE | Context Dependent Application Model | ||
| 20 | /PLMU/IF_FRW_C_APPL_MODEL - ACTION | Context Dependent Application Model | ||
| 21 | /PLMU/IF_FRW_C_APPL_MODEL - ACTION | Context Dependent Application Model | ||
| 22 | /PLMU/IF_FRW_C_APPL_MODEL - ACTION | Context Dependent Application Model | ||
| 23 | /PLMU/IF_FRW_G_ACTIONS - GET_ACTION_DEFINITION | Feeder Callback - Define and Process Actions | ||
| 24 | /PLMU/IF_FRW_G_ACTIONS - PROCESS_ACTION_EVENT | Feeder Callback - Define and Process Actions | ||
| 25 | /PLMU/IF_FRW_G_AFTER_GET_DATA - AFTER_GET_DATA | Feeder Callback - After GET_DATA | ||
| 26 | /PLMU/IF_FRW_G_APPL_MODEL - ACTION | Application Model | ||
| 27 | /PLMU/IF_FRW_G_APPL_MODEL - ACTION | Application Model | ||
| 28 | /PLMU/IF_FRW_G_APPL_MODEL - ACTION | Application Model | ||
| 29 | /PLMU/IF_FRW_G_APPL_MODEL - RETRIEVE | Application Model | ||
| 30 | /PLMU/IF_FRW_G_APPL_MODEL - RETRIEVE | Application Model | ||
| 31 | /PLMU/IF_FRW_G_APPL_MODEL - UPDATE | Application Model | ||
| 32 | /PLMU/IF_FRW_G_APPL_MODEL - ACTION | Application Model | ||
| 33 | /PLMU/IF_FRW_G_BEFORE_FLUSH - BEFORE_FLUSH | Feeder Callback - Before FLUSH | ||
| 34 | /PLMU/IF_FRW_G_BEFORE_GET_DATA - BEFORE_GET_DATA | Feeder Callback - Before GET_DATA | ||
| 35 | /PLMU/IF_FRW_G_CONFIG_PARAM - GET_PARAMETER_DESCRIPTION | Feeder Callback - Set and Get Configuration Parameter | ||
| 36 | /PLMU/IF_FRW_G_CONFIG_PARAM - SET_PARAMETER_VALUES | Feeder Callback - Set and Get Configuration Parameter | ||
| 37 | /PLMU/IF_FRW_G_CONTEXT - GET_ROW | Context | ||
| 38 | /PLMU/IF_FRW_G_CONTEXT - GET_ROW | Context | ||
| 39 | /PLMU/IF_FRW_G_CONTEXT - GET_ROW | Context | ||
| 40 | /PLMU/IF_FRW_G_CONTEXT - GET_ROW | Context | ||
| 41 | /PLMU/IF_FRW_G_CONTEXT - GET_ROW | Context | ||
| 42 | /PLMU/IF_FRW_G_CONTEXT - SET_ROW | Context | ||
| 43 | /PLMU/IF_FRW_G_CONTEXT - SET_ROW | Context | ||
| 44 | /PLMU/IF_FRW_G_FIELD_DEF - CHANGE_FIELD_DEFINITION | Feeder Callback - Field Definition (Form/List/Tree) | ||
| 45 | /PLMU/IF_FRW_G_GLOBAL_EVENTS - PROCESS_GLOBAL_EVENT | Feeder Callback - Global Event Processing | ||
| 46 | /PLMU/IF_FRW_G_OVS - HANDLE_PHASE_0 | Feeder Callback - OVS Handler | ||
| 47 | /PLMU/IF_FRW_G_OVS - HANDLE_PHASE_1 | Feeder Callback - OVS Handler | ||
| 48 | /PLMU/IF_FRW_G_OVS - HANDLE_PHASE_2 | Feeder Callback - OVS Handler | ||
| 49 | /PLMU/IF_FRW_G_OVS - HANDLE_PHASE_3 | Feeder Callback - OVS Handler | ||
| 50 | /PLMU/IF_FRW_G_OVS_CALLBACK - GET_ROW_DATA | Handle for Object Value Selection (OVS) | ||
| 51 | /PLMU/IF_FRW_G_OVS_CALLBACK - GET_ROW_DATA | Handle for Object Value Selection (OVS) | ||
| 52 | /PLMU/IF_FRW_G_OVS_CALLBACK - GET_SELECTION | Handle for Object Value Selection (OVS) | ||
| 53 | /PLMU/IF_FRW_G_OVS_CALLBACK - SET_CONFIGURATION | Handle for Object Value Selection (OVS) | ||
| 54 | /PLMU/IF_FRW_G_OVS_CALLBACK - SET_INPUT_STRUCTURE | Handle for Object Value Selection (OVS) | ||
| 55 | /PLMU/IF_FRW_G_OVS_CALLBACK - SET_ROW_DATA | Handle for Object Value Selection (OVS) | ||
| 56 | CL_EAMS_UI_CONVEXIT - CONVEXIT_SGENR | Conversion exits for different objects | ||
| 57 | CL_EAMS_UI_CONVEXIT - S_GET_INSTANCE | Conversion exits for different objects | ||
| 58 | CL_EAMS_UI_CONVEXIT - CONVEXIT_SWENR | Conversion exits for different objects | ||
| 59 | CL_EAMS_UI_CONVEXIT - CONVEXIT_SWENR | Conversion exits for different objects | ||
| 60 | CL_EAMS_UI_CONVEXIT - CONVEXIT_SMENR | Conversion exits for different objects | ||
| 61 | CL_EAMS_UI_CONVEXIT - CONVEXIT_SMENR | Conversion exits for different objects | ||
| 62 | CL_EAMS_UI_CONVEXIT - CONVEXIT_SGENR | Conversion exits for different objects | ||
| 63 | CL_EAMS_UI_FD_MP_INIT - VALIDATE_INITIAL_SCREEN | WD feeder for measuring point initial screen | ||
| 64 | CL_EAMS_UI_FD_MP_INIT - UPDATE_INITIAL_DATA | WD feeder for measuring point initial screen | ||
| 65 | CL_EAMS_UI_FD_MP_INIT - SET_IDR_INIT | WD feeder for measuring point initial screen | ||
| 66 | CL_EAMS_UI_FD_MP_INIT - OVS_GET_OVS_INFO | WD feeder for measuring point initial screen | ||
| 67 | CL_EAMS_UI_FD_MP_INIT - RETRIEVE_INITIAL_DATA | WD feeder for measuring point initial screen | ||
| 68 | CL_EAMS_UI_FD_MP_INIT - OVS_GET_OVS_INFO | WD feeder for measuring point initial screen | ||
| 69 | CL_EAMS_UI_FD_MP_INIT - GET_REF_OBJ_TYPE_FIXED_VALUES | WD feeder for measuring point initial screen | ||
| 70 | CL_EAMS_UI_FD_MP_INIT - GET_REAL_EST_TYPE_FIXED_VALUES | WD feeder for measuring point initial screen | ||
| 71 | CL_EAMS_UI_FD_MP_INIT - CHECK_AUTHORIZATIONS | WD feeder for measuring point initial screen | ||
| 72 | CL_EAMS_UI_FD_MP_INIT - OVS_GET_OVS_INFO | WD feeder for measuring point initial screen | ||
| 73 | CL_EAMS_UI_SERVICE - OVS_HANDLE_PHASE_2 | Service and convertion methods | ||
| 74 | CL_EAMS_UI_SERVICE - S_GET_INSTANCE | Service and convertion methods | ||
| 75 | CL_EAMS_UI_SERVICE - S_GET_INSTANCE | Service and convertion methods | ||
| 76 | CL_EAMS_UI_SERVICE - SET_APPL_MODE | Service and convertion methods | ||
| 77 | CL_EAMS_UI_SERVICE - OVS_BUILD_STRUC_FROM_SHLP | Service and convertion methods | ||
| 78 | CL_EAMS_UI_SERVICE - GET_SHLP_FOR_FIELD | Service and convertion methods | ||
| 79 | CL_EAMS_UI_SERVICE - CHECK_TECH_OBJ_NO | Service and convertion methods | ||
| 80 | CL_EAMS_UI_SERVICE - CHECK_MANDATORY_FIELDS | Service and convertion methods | ||
| 81 | CL_FPM_FACTORY - GET_INSTANCE | Factory to provide an instance of interface IF_FPM_API | ||
| 82 | CL_WD_RUNTIME_SERVICES - GET_URL_PARAMETER | General Services of Web Dynpro Runtime | ||
| 83 | IF_FPM - GET_SERVICE | Interface for accessing FPM functionality | ||
| 84 | IF_FPM - SET_APPLICATION_TITLE | Interface for accessing FPM functionality | ||
| 85 | IF_FPM_IDR - INITIALIZE_ITEMS | IF_FPM_IDR-INITIALIZE_ITEMS | ||
| 86 | IF_FPM_IDR - SET_APPLICATION_TITLE | IF_FPM_IDR-SET_APPLICATION_TITLE |