Class Method list used by SAP ABAP Class /PLMU/CL_FRW_TEST_BADI_APPCC (Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC)
SAP ABAP Class
/PLMU/CL_FRW_TEST_BADI_APPCC (Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | /PLMU/CL_FRW_APPL_CNTRL - SET_CNR_OPERATIONS | Application Controller Service Class | ||
| 2 | /PLMU/CL_FRW_APPL_CNTRL - SET_LEADING_ABBID | Application Controller Service Class | ||
| 3 | /PLMU/CL_FRW_APPL_CNTRL - SET_CNR_OPERATIONS | Application Controller Service Class | ||
| 4 | /PLMU/CL_FRW_FACTORY - GET_ACTION_UTILITIES | Factory Class | ||
| 5 | /PLMU/CL_FRW_FACTORY - GET_BASIC_APPLICATION_MODEL | Factory Class | ||
| 6 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE it_node_id = get_scarr_id( ) |
|
| 7 | /PLMU/CL_FRW_TEST_BADI_APPCC - PREPARE_IDR | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE prepare_idr( ). |
|
| 8 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE et_node_data = et_scarr_data ). |
|
| 9 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE et_index_failed = lt_index_failed |
|
| 10 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE ev_failed = lv_failed |
|
| 11 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE IMPORTING |
|
| 12 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE iv_lock = abap_false |
|
| 13 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE iv_node_name = /plmu/if_frw_test_mp_c=>gs_c_node-scarr |
|
| 14 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE mo_model->retrieve( |
|
| 15 | /PLMU/CL_FRW_TEST_BADI_APPCC - BUFFER_SPFLI_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE buffer_spfli_id( io_wire_services = io_wire_services ). |
|
| 16 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_DATA | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE get_scarr_data( |
|
| 17 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_DATA | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE IMPORTING |
|
| 18 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_DATA | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE et_scarr_data = lt_scarr_data ). |
|
| 19 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_DATA | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE get_scarr_data( |
|
| 20 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_DATA | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE IMPORTING |
|
| 21 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_DATA | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE et_scarr_data = lt_scarr_data ). |
|
| 22 | /PLMU/CL_FRW_TEST_BADI_APPCC - GET_SCARR_ID | Class for BAdI Impl.: /PLMU/EH_FRW_TEST_APPCC | SOURCE EXPORTING |
|
| 23 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_NEEDS_CONFIRMATION | OIF Application Controller | ||
| 24 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - PROCESS_EVENT | OIF Application Controller | ||
| 25 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - PROCESS_BEFORE_OUTPUT | OIF Application Controller | ||
| 26 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - OVERRIDE_EVENT_OIF | OIF Application Controller | ||
| 27 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - OVERRIDE_CONFIG_TABBED | OIF Application Controller | ||
| 28 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - NEEDS_CONFIRMATION | OIF Application Controller | ||
| 29 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - INITIALIZATION | OIF Application Controller | ||
| 30 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - FLUSH | OIF Application Controller | ||
| 31 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_PROCESS_EVENT | OIF Application Controller | ||
| 32 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_PROCESS_BEFORE_OUTPUT | OIF Application Controller | ||
| 33 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_FLUSH | OIF Application Controller | ||
| 34 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_FAILED_EVENT | OIF Application Controller | ||
| 35 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_CLEANUP | OIF Application Controller | ||
| 36 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_AFTER_FAILED_EVENT | OIF Application Controller | ||
| 37 | /PLMU/IF_EX_FRW_CONSUMER_APPCC - AFTER_SAVE | OIF Application Controller | ||
| 38 | /PLMU/IF_FRW_ACTION_UTIL - ADD_SERVICES_TO_CNR | Navigation Utilities | ||
| 39 | /PLMU/IF_FRW_APPL_CNTRL - SET_CNR_OPERATIONS | Application Controller Service Class | ||
| 40 | /PLMU/IF_FRW_APPL_CNTRL - SET_CNR_OPERATIONS | Application Controller Service Class | ||
| 41 | /PLMU/IF_FRW_APPL_CNTRL - SET_LEADING_ABBID | Application Controller Service Class | ||
| 42 | /PLMU/IF_FRW_BASIC_APPL_MODEL - ACTION | Basic Application Model | ||
| 43 | /PLMU/IF_FRW_BASIC_APPL_MODEL - RETRIEVE | Basic Application Model | ||
| 44 | /PLMU/IF_FRW_MAP_HEADER - SUPPLY_HEADER_DATA | Header Object Mapper | ||
| 45 | /PLMU/IF_FRW_W_SERVICES - GET_NODE_DATA | Wiring Services | ||
| 46 | CL_FPM_CONFIRMATION_REQUEST - CONSTRUCTOR | Requests an end-user confirmation (e.g. data loss warning) | ||
| 47 | CL_FPM_FACTORY - GET_INSTANCE | Factory to provide an instance of interface IF_FPM_API | ||
| 48 | IF_FPM - GET_SERVICE | Interface for accessing FPM functionality | ||
| 49 | IF_FPM_IDR - ADD_ITEM_GROUP_BY_VAL | IF_FPM_IDR-ADD_ITEM_GROUP_BY_VAL | ||
| 50 | IF_FPM_IDR - CHANGE_ITEM_GROUP_BY_VAL | IF_FPM_IDR-CHANGE_ITEM_GROUP_BY_VAL | ||
| 51 | IF_FPM_PARAMETER - GET_VALUE | Property Bag | ||
| 52 | IF_FPM_PARAMETER - SET_VALUE | Property Bag |