SAP ABAP Table RPLM_TS_POWL_MPOINTS_DEF (Object Definition for Measuring Points in Worklist)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷ EP-PCT-MAN-MP (Application Component) BP for Maintenance Planner
⤷ RPLM_MP_BE (Package) Maintenance Planner Backend
⤷ EP-PCT-MAN-MP (Application Component) BP for Maintenance Planner
⤷ RPLM_MP_BE (Package) Maintenance Planner Backend
Basic Data
Table Category | INTTAB | Structure |
Structure | RPLM_TS_POWL_MPOINTS_DEF | Table Relationship Diagram |
Short Description | Object Definition for Measuring Points in Worklist |
Delivery and Maintenance
Pool/cluster | ||
Delivery Class | ||
Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|
---|---|---|---|---|---|---|---|---|---|
1 | MANDT | MANDT | MANDT | CLNT | 3 | 0 | Client | * | |
2 | POINT | IMRC_POINT | IMRC_POINT | CHAR | 12 | 0 | Measuring Point | * | |
3 | PTTXT | IMRC_PTTXT | TEXT40 | CHAR | 40 | 0 | Description of Measuring Point | ||
4 | ATNAM | ATNAM | ATNAM | CHAR | 30 | 0 | Characteristic Name | ||
5 | UNITC | IMRC_UNITC | MSEC6 | CHAR | 6 | 0 | Unit of Measurement for Measuring Point Characteristic | * | |
6 | INDCT | IMRC_INDCT | X | CHAR | 1 | 0 | Indicator to Show that Measuring Point Is a Counter | ||
7 | TPLNR | ILOM_STRNO | ILOM_STRNO | CHAR | 40 | 0 | Functional location label | ||
8 | EQUNR | EQUNR | EQUNR | CHAR | 18 | 0 | Equipment Number | * | |
9 | MPOBJ | IMRC_MPOBJ | J_OBJNR | CHAR | 22 | 0 | Object Number for the Measuring Point Object | * | |
10 | PSORTR | IMRCRPSORT | X | CHAR | 1 | 0 | Indicator: Position Number Comes From Reference MeasPoint | ||
11 | MLANG | SPRAS | SPRAS | LANG | 1 | 0 | Language Key | * | |
12 | KZLTX | ILOM_KZLTX | X | CHAR | 1 | 0 | Indicator: Long text exists | ||
13 | MPTYP | IMRC_MPTYP | IMRC_MPTYP | CHAR | 1 | 0 | Measuring Point Category | * | |
14 | IRFMP | IMRC_IRFMP | X | CHAR | 1 | 0 | Indicator: MeasPoint Is a Reference Measuring Point | ||
15 | ERDAT | ICRDT | DATUM | DATS | 8 | 0 | Date on Which Object Was Created | ||
16 | ERNAM | ICRNA | USNAM | CHAR | 12 | 0 | Name of User Who Created the Object | ||
17 | AEDAT | IUPDT | DATUM | DATS | 8 | 0 | Date on which the object was last changed | ||
18 | AENAM | IUPNA | USNAM | CHAR | 12 | 0 | Name of the User Who Last Changed the Object | ||
19 | INACT | IMRC_INACT | X | CHAR | 1 | 0 | Indicator: Measuring Point Inactive | ||
20 | LVORM | IMRC_DEL2 | IMRC_DEL2 | CHAR | 1 | 0 | Deletion Flag for 2-Level Deletion Logic | ||
21 | LOCAS | IMRC_LOCAS | MATNR | CHAR | 18 | 0 | Assembly for Localization of Measuring Point | * | |
22 | REFMP | IMRC_REFMP | IMRC_POINT | CHAR | 12 | 0 | Reference Meas.Pt | * | |
23 | DESIRR | IMRCRDESIR | X | CHAR | 1 | 0 | Indicator: Target Value Comes From Reference Measuring Point | ||
24 | DSTXT | IMRC_DSTXT | TEXT40 | CHAR | 40 | 0 | Aditional Short Text for Measuring Point | ||
25 | DSTXTR | IMRCRDSTXT | X | CHAR | 1 | 0 | Indicator: Additional Text Comes From Reference MeasPoint | ||
26 | INDRV | IMRC_INDRV | X | CHAR | 1 | 0 | Indicator: Counter Runs Backwards | ||
27 | INDTR | IMRC_INDTR | X | CHAR | 1 | 0 | Indicator That Measurement Reading Transfer is Supported | ||
28 | TRANS | IMRC_TRANS | IMRC_POINT | CHAR | 12 | 0 | Measuring Point from Which Meas. Reading Was Transferred | * | |
29 | CODCT | IMRC_CODCT | QKATART | CHAR | 1 | 0 | Catalog Type - Measurement Reading Valuation Code | * | |
30 | CODGR | IMRC_CODGR | QCODEGRP | CHAR | 8 | 0 | Code Group - Measurement Reading Valuation Code | * | |
31 | CODGRR | IMRCRCODGR | X | CHAR | 1 | 0 | Indicator: Code Group Comes From Reference Measuring Point | ||
32 | CDSUF | IMRC_CDSUF | X | CHAR | 1 | 0 | Indicator: Valuation Code Sufficient for Measurmnt. Document | ||
33 | ATVOR | IMRC_INEGV | X | CHAR | 1 | 0 | Indicator: Negative Values Allowed | ||
34 | MSEHI | MSEHI | MEINS | UNIT | 3 | 0 | Unit of Measurement | * | |
35 | CJUMC | IMRC_CJUMC | FLTP_INOUT | CHAR | 22 | 0 | Counter Overflow Reading | ||
36 | PYEAC | IMRC_PYEAC | FLTP_INOUT | CHAR | 22 | 0 | Annual Estimate | ||
37 | MRMIC | IMRC_MRMIC | FLTP_INOUT | CHAR | 22 | 0 | Lower Measurement Range Limit in Measurement Range Unit | ||
38 | MRMAC | IMRC_MRMAC | FLTP_INOUT | CHAR | 22 | 0 | Upper Measurement Range Limit in Measurement Range Unit | ||
39 | UNITM | IMRC_UNITM | MSEC6 | CHAR | 6 | 0 | Measurement Range Unit | * | |
40 | ATINN | ATINN | ATINN | NUMC | 10 | 0 | Internal characteristic | * | |
41 | ATINNR | IMRCRATINN | X | CHAR | 1 | 0 | Indicator: Charac Comes From Reference Measuring Point | ||
42 | EXPON | IMRC_EXPON | IMRC_EXPON | INT2 | 5 | 0 | Power of Ten Exponent for Floating Point Display | ||
43 | DECIM | IMRC_DECIM | IMRC_DECIM | INT2 | 5 | 0 | Number of Decimal Places for Number Display | ||
44 | MODTR | IMRC_MODTR | IMRC_MODTR | CHAR | 1 | 0 | Mode of Counter Reading Transfer | ||
45 | DESIC | IMRC_DESIC | FLTP_INOUT | CHAR | 22 | 0 | Measuring Point Target Value |
History
Last changed by/on | SAP | 20130529 |
SAP Release Created in | 700 |