Hierarchy

⤷

⤷

Attribute
Message class | ![]() |
PPESTATUS | |
Short Description | ![]() |
Messages: iPPE Status Management | |
Message Number | ![]() |
012 | |
Documentation status | ![]() |
||
Authorization check Error Message | |||
Changed On | ![]() |
20040316 |
Message Text
Help Document
Diagnosis
The same status can only be assigned multiple iPPE object types if the same technical type (node, variant, or alternative) and application are assigned.
Example:
You cannot assign STATUS_1 to the node type S_GEN and variant type S_CMPST at the same time because the technical types are different. In addition, you cannot assign STATUS_1 to a node type of the application product structure (CMP) and a node type of the application process structure (ACT). However, you can assign STATUS_1 to the component variant and assembly item because the technical types (variant) and the applications (product structure (CMP)) are the same.
System Response
Procedure
Choose General Settings -> Define Settings for Status Management in iPPE Customizing, and make the relevant settings under Status Object Types.
Procedure for System Administration
History
Last changed on/by | ![]() |
20040316 | SAP |
SAP Release Created in | 46C2 |