SAP ABAP Interface IWCI_IF_FPM_FLOORPLAN_COMP (WebDynpro Interface INTERFACECONTROLLER)
Hierarchy
SAP_UI (Software Component) User Interface Technology
   BC-WD-CMP-FPM (Application Component) Floorplan Manager Web Dynpro ABAP
     APB_FPM_CORE (Package) Floorplan Manager (Framework)
Properties
Interface IWCI_IF_FPM_FLOORPLAN_COMP  
Short Description WebDynpro Interface INTERFACECONTROLLER    
General Data
Package APB_FPM_CORE   Floorplan Manager (Framework) 
Created 20070411   SAP 
Last changed 20130531   SAP 
Unicode checks active    
Forward declarations
Interface IWCI_IF_FPM_FLOORPLAN_COMP has no forward declaration.
Interfaces
Interface IWCI_IF_FPM_FLOORPLAN_COMP has no interface.
Friends
Interface IWCI_IF_FPM_FLOORPLAN_COMP has no friend.
Attributes
Interface IWCI_IF_FPM_FLOORPLAN_COMP has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CLOSE_APPLICATION Instance method Public Method 20080221
2 CONFIRM_EVENT_COMPLETION Instance method Public Method 20070515
3 GET_DIALOG_WINDOW Instance method Public Method 20100709
4 GET_EMBEDMENT_LEVEL Instance method Public Method 20110328
5 GET_INFO_OBJECT Instance method Public Method 20080825
6 GET_ROOT_VIEW_CONTROLLER Instance method Public Method 20121016
7 GET_SUSPEND_RESUME_UTILITY Instance method Public Method 20110103
8 GET_TRANSIENT_STATE Instance method Public Method 20080312
9 GET_UIBBS_FOR_EVENT Instance method Public Method 20070412
10 INPLACE_NAVIGATION Instance method Public Method 20110103
11 MODIFY_VIEW_ASSEMBLY Instance method Public Method 20070411
12 REQUEST_CONFIRMATION Instance method Public Method 20070504
13 SUSPEND Instance method Public Method 20110103
14 WD_GET_API Instance method Public Method 20070411
Events
Interface IWCI_IF_FPM_FLOORPLAN_COMP has no event.
Types
Interface IWCI_IF_FPM_FLOORPLAN_COMP has no local type.
Method Signatures

Method CLOSE_APPLICATION Signature

Method CLOSE_APPLICATION on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no parameter.
Method CLOSE_APPLICATION on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method CONFIRM_EVENT_COMPLETION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20070531
2 Returning RV_CONTINUE Value transfer Type reference (TYPE) WDY_BOOLEAN 20070515

Method CONFIRM_EVENT_COMPLETION on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method GET_DIALOG_WINDOW Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EO_DIALOG_WINDOW Call by reference Object reference (TYPE REF TO) IF_WD_WINDOW 20100709

Method GET_DIALOG_WINDOW on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method GET_EMBEDMENT_LEVEL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_UIBB_ID Call by reference Type reference (TYPE) FPM_S_UIBB_ID 20110328
2 Returning RV_LEVEL Value transfer Type reference (TYPE) I 20110328

Method GET_EMBEDMENT_LEVEL on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method GET_INFO_OBJECT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RO_INFO_OBJECT Value transfer Object reference (TYPE REF TO) OBJECT 20080825

Method GET_INFO_OBJECT on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method GET_ROOT_VIEW_CONTROLLER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RO_VIEW_CONTROLLER Value transfer Object reference (TYPE REF TO) IF_WD_VIEW_CONTROLLER 20121016

Method GET_ROOT_VIEW_CONTROLLER on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method GET_SUSPEND_RESUME_UTILITY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RO_FPM_SUSPEND_RESUME_UTILITY Value transfer Object reference (TYPE REF TO) CL_FPM_SUSPEND_RESUME_UTILITY 20110103

Method GET_SUSPEND_RESUME_UTILITY on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method GET_TRANSIENT_STATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_TRANSIENT_STATE Call by reference Type reference (TYPE) FPM_TRANSIENT_STATE 20080312

Method GET_TRANSIENT_STATE on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method GET_UIBBS_FOR_EVENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CO_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20070418
2 Exporting ET_UIBB Call by reference Type reference (TYPE) FPM_T_UIBB_KEY 20070418
3 Exporting EV_CANCEL_EVENT Call by reference Type reference (TYPE) WDY_BOOLEAN 20070418

Method GET_UIBBS_FOR_EVENT on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method INPLACE_NAVIGATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_POST_PARAMETERS Call by reference Type reference (TYPE) WDY_BOOLEAN 20110103
2 Importing ID_URL Call by reference Type reference (TYPE) STRING 20110103
3 Importing IT_PARAMETERS Call by reference Type reference (TYPE) TIHTTPNVP 20110103

Method INPLACE_NAVIGATION on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method MODIFY_VIEW_ASSEMBLY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20070531
2 Importing IV_EVENT_FAILED Call by reference Type reference (TYPE) BOOLE_D 20070413

Method MODIFY_VIEW_ASSEMBLY on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method REQUEST_CONFIRMATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_CONFIRMATION_REQUEST Call by reference Object reference (TYPE REF TO) CL_FPM_CONFIRMATION_REQUEST 20070504

Method REQUEST_CONFIRMATION on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method SUSPEND Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ID_ENVIRONMENT Call by reference Type reference (TYPE) I 20110103
2 Importing ID_POST_PARAMETERS Call by reference Type reference (TYPE) BOOLE_D 20110103
3 Importing ID_URL Call by reference Type reference (TYPE) STRING 20110103
4 Importing IT_PARAMETERS Call by reference Type reference (TYPE) TIHTTPNVP 20110103

Method SUSPEND on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.

Method WD_GET_API Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RESULT Value transfer Object reference (TYPE REF TO) IF_WD_CONTROLLER 20070411

Method WD_GET_API on Interface IWCI_IF_FPM_FLOORPLAN_COMP has no exception.
History
Last changed by/on SAP  20130531 
SAP Release Created in