SAP ABAP Interface IWCI_FPM_HCT_GENERAL_SETTINGS (WebDynpro Interface COMPONENTCONTROLLER)
Hierarchy
SAP_UI (Software Component) User Interface Technology
   BC-WD-CMP-FPM (Application Component) Floorplan Manager Web Dynpro ABAP
     APB_FPM_HCT (Package) Harmonized Configuration Tool
Properties
Interface IWCI_FPM_HCT_GENERAL_SETTINGS  
Short Description WebDynpro Interface COMPONENTCONTROLLER    
General Data
Package APB_FPM_HCT   Harmonized Configuration Tool 
Created 20090622   SAP 
Last changed 20141121    
Unicode checks active    
Forward declarations
Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no forward declaration.
Interfaces
Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no interface.
Friends
Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no friend.
Attributes
Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CHECK Instance method Public Method 20090622
2 CLEAN_UP Instance method Public Method 20101104
3 GET_SCREEN_SETTINGS Instance method Public Method 20140203
4 GET_TOOLBAR_ITEMS Instance method Public Method 20090724
5 INIT_SCREEN_SETTINGS Instance method Public Method 20140203
6 ON_ACTION_TOOLBAR_ITEM Instance method Public Method 20090724
7 SET_CONTEXT Instance method Public Method 20090622
8 SET_ELEMENT Instance method Public Method 20090622
9 SET_GLOBAL_ATTRIBUTES Instance method Public Method 20090622
10 SET_SERVICE_HANDLER Instance method Public Method 20090622
11 WD_GET_API Instance method Public Method 20090622
Events
Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no event.
Types
Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no local type.
Method Signatures

Method CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_MESSAGE_MANAGER Call by reference Object reference (TYPE REF TO) IF_WD_MESSAGE_MANAGER 20090622
2 Returning RV_OK Value transfer Type reference (TYPE) WDY_BOOLEAN 20090622

Method CHECK on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method CLEAN_UP Signature

Method CLEAN_UP on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no parameter.
Method CLEAN_UP on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method GET_SCREEN_SETTINGS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_MORE_ACTIVE Call by reference Type reference (TYPE) WDY_BOOLEAN 20140203

Method GET_SCREEN_SETTINGS on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method GET_TOOLBAR_ITEMS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_BUTTON Call by reference Type reference (TYPE) FPM_T_HCT_BUTTON 20091126
2 Exporting ET_BUTTON_CHOICE Call by reference Type reference (TYPE) FPM_T_HCT_BUTTON_CHOICE 20091126

Method GET_TOOLBAR_ITEMS on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method INIT_SCREEN_SETTINGS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_MORE_ACTIVE Call by reference Type reference (TYPE) WDY_BOOLEAN 20140203

Method INIT_SCREEN_SETTINGS on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method ON_ACTION_TOOLBAR_ITEM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_ID Call by reference Type reference (TYPE) STRING 20090724

Method ON_ACTION_TOOLBAR_ITEM on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method SET_CONTEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_CONTEXT_NODE Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_NODE 20090622
2 Importing IV_CHANGE_MODE Call by reference Type reference (TYPE) WDY_BOOLEAN 20090622

Method SET_CONTEXT on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method SET_ELEMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT 20090622
2 Importing IT_CONTEXT_ELEMENT Call by reference Type reference (TYPE) WDR_CONTEXT_ELEMENT_SET 20090713

Method SET_ELEMENT on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method SET_GLOBAL_ATTRIBUTES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_GLOBAL_ATTRIBUTES Call by reference Type reference (TYPE) FPM_S_CFG_GLOBAL_ATTRIBUTES 20090622

Method SET_GLOBAL_ATTRIBUTES on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method SET_SERVICE_HANDLER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_SERVICE_HANDLER Call by reference Object reference (TYPE REF TO) IF_FPM_CFG_SERVICE_HANDLER 20090622

Method SET_SERVICE_HANDLER on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.

Method WD_GET_API Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RESULT Value transfer Object reference (TYPE REF TO) IF_WD_CONTROLLER 20090622

Method WD_GET_API on Interface IWCI_FPM_HCT_GENERAL_SETTINGS has no exception.
History
Last changed by/on SAP  20141121 
SAP Release Created in 730