SAP ABAP Interface IWCI_FPM_BICS_GRID_DIALOG (WebDynpro Interface COMPONENTCONTROLLER)
Hierarchy
SAP_BW (Software Component) SAP Business Warehouse
   BW-RUI-FPM (Application Component) FPM Analytical GUIBB
     BW_REPORTING_FPM (Package) FPM UIBBs
Properties
Interface IWCI_FPM_BICS_GRID_DIALOG  
Short Description WebDynpro Interface COMPONENTCONTROLLER    
General Data
Package BW_REPORTING_FPM   FPM UIBBs 
Created 20130918   SAP 
Last changed 20140121   SAP 
Unicode checks active    
Forward declarations
Interface IWCI_FPM_BICS_GRID_DIALOG has no forward declaration.
Interfaces
Interface IWCI_FPM_BICS_GRID_DIALOG has no interface.
Friends
Interface IWCI_FPM_BICS_GRID_DIALOG has no friend.
Attributes
Interface IWCI_FPM_BICS_GRID_DIALOG has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 OPEN_FILTER_DIALOG Instance method Public Method 20130918
2 OPEN_HIERSEL_DIALOG Instance method Public Method 20130918
3 OPEN_MEASURE_DIALOG Instance method Public Method 20130918
4 OPEN_P13N_DIALOG Instance method Public Method 20130918
5 OPEN_PARAMETER_DIALOG Instance method Public Method 20130918
6 WD_GET_API Instance method Public Method 20130918
Events
Interface IWCI_FPM_BICS_GRID_DIALOG has no event.
Types
Interface IWCI_FPM_BICS_GRID_DIALOG has no local type.
Method Signatures

Method OPEN_FILTER_DIALOG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_BICS_CHARACTERISTIC Call by reference Object reference (TYPE REF TO) IF_BICS_CHARACTERISTIC 20130918
2 Importing IO_BICS_QUERY Call by reference Object reference (TYPE REF TO) IF_BICS_QV 20130918
3 Importing IO_FPM Call by reference Object reference (TYPE REF TO) IF_FPM 20130918
4 Importing IO_FPM_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20130918
5 Importing IV_INSTANCE_ID Call by reference Type reference (TYPE) FPM_BICS_INSTANCE_ID 20130918
6 Importing IV_QUERY_ID Call by reference Type reference (TYPE) RSZCOMPID 20130918

Method OPEN_FILTER_DIALOG on Interface IWCI_FPM_BICS_GRID_DIALOG has no exception.

Method OPEN_HIERSEL_DIALOG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_BICS_CHARACTERISTIC Call by reference Object reference (TYPE REF TO) IF_BICS_CHARACTERISTIC 20130918
2 Importing IO_FPM Call by reference Object reference (TYPE REF TO) IF_FPM 20130918
3 Importing IO_FPM_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20130918
4 Importing IV_INSTANCE_ID Call by reference Type reference (TYPE) FPM_BICS_INSTANCE_ID 20130918
5 Importing IV_QUERY_ID Call by reference Type reference (TYPE) RSZCOMPID 20130918

Method OPEN_HIERSEL_DIALOG on Interface IWCI_FPM_BICS_GRID_DIALOG has no exception.

Method OPEN_MEASURE_DIALOG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_BICS_DATA_CELL Call by reference Object reference (TYPE REF TO) IF_BICS_QV_DATA_CELL 20130918
2 Importing IO_BICS_QUERY Call by reference Object reference (TYPE REF TO) IF_BICS_QV 20130918
3 Importing IO_FPM Call by reference Object reference (TYPE REF TO) IF_FPM 20130918
4 Importing IO_FPM_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20130918
5 Importing IV_INSTANCE_ID Call by reference Type reference (TYPE) FPM_BICS_INSTANCE_ID 20130918
6 Importing IV_QUERY_ID Call by reference Type reference (TYPE) RSZCOMPID 20130918

Method OPEN_MEASURE_DIALOG on Interface IWCI_FPM_BICS_GRID_DIALOG has no exception.

Method OPEN_P13N_DIALOG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_BICS_QUERY Call by reference Object reference (TYPE REF TO) IF_BICS_QV 20130918
2 Importing IO_BM_MANAGER Call by reference Object reference (TYPE REF TO) CL_FPM_BICS_PERSISTENCE 20130918
3 Importing IO_FPM Call by reference Object reference (TYPE REF TO) IF_FPM 20130918
4 Importing IO_FPM_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20130918
5 Importing IV_INSTANCE_ID Call by reference Type reference (TYPE) FPM_BICS_INSTANCE_ID 20130918
6 Importing IV_QUERY_ID Call by reference Type reference (TYPE) RSZCOMPID 20130918

Method OPEN_P13N_DIALOG on Interface IWCI_FPM_BICS_GRID_DIALOG has no exception.

Method OPEN_PARAMETER_DIALOG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_BICS_PLANNING_FUNCTION Call by reference Object reference (TYPE REF TO) IF_BICS_PLANNING_FUNCTION 20130918
2 Importing IO_BICS_QUERY Call by reference Object reference (TYPE REF TO) IF_BICS_QV 20130918
3 Importing IO_FPM Call by reference Object reference (TYPE REF TO) IF_FPM 20130918
4 Importing IO_FPM_EVENT Call by reference Object reference (TYPE REF TO) CL_FPM_EVENT 20130918
5 Importing IV_INSTANCE_ID Call by reference Type reference (TYPE) FPM_BICS_INSTANCE_ID 20130918
6 Importing IV_QUERY_ID Call by reference Type reference (TYPE) RSZCOMPID 20130918

Method OPEN_PARAMETER_DIALOG on Interface IWCI_FPM_BICS_GRID_DIALOG has no exception.

Method WD_GET_API Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RESULT Value transfer Object reference (TYPE REF TO) IF_WD_CONTROLLER 20130918

Method WD_GET_API on Interface IWCI_FPM_BICS_GRID_DIALOG has no exception.
History
Last changed by/on SAP  20140121 
SAP Release Created in 740