SAP ABAP Interface IF_RSRTS_TRPR (IF_RSRTS_TRPR)
Hierarchy
☛
SAP_BW (Software Component) SAP Business Warehouse
⤷ BW-BEX-OT (Application Component) OLAP Technology
⤷ RSR_TRANSIENT_SOURCE (Package) Transiente Source Engine
⤷ BW-BEX-OT (Application Component) OLAP Technology
⤷ RSR_TRANSIENT_SOURCE (Package) Transiente Source Engine
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_RSRTS_METADATA_ODP | Metadata for operational data provider | 20110107 |
Properties
Interface | IF_RSRTS_TRPR | |
Short Description |
General Data
Package | RSR_TRANSIENT_SOURCE | Transiente Source Engine |
Created | 20110107 | SAP |
Last changed | 20130531 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | CL_RSRTS_METADATA | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) |
2 | RS | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Interface IF_RSRTS_TRPR has no interface.
Friends
Interface IF_RSRTS_TRPR has no friend.
Attributes
Interface IF_RSRTS_TRPR has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ACTIVATE_DEPENDENT_OBJECTS | Instance method | Public | Method | 20110128 | |
2 | CHECK_AUTHORITY_ADMWB | Instance method | Public | Method | 20110107 | |
3 | CHECK_METADATA | Instance method | Public | Method | 20110825 | |
4 | FACTORY | Static method | Public | Method | 20110107 | |
5 | GET_DEPENDENT_OBJECTS | Instance method | Public | Method | 20110107 |
Events
Interface IF_RSRTS_TRPR has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | NT_S_OBJECT | Public | See coding | 20110107 | begin of NT_S_OBJECT,
type type RSTLOGO,
objnm type SOBJ_NAME,
is_tlogo type rs_bool,
end of nt_s_object
|
||
2 | NT_TS_OBJECT | Public | See coding | 20110107 | nt_ts_object type sorted table of nt_s_object
with unique key type objnm
|
Method Signatures
Method ACTIVATE_DEPENDENT_OBJECTS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_T_MSG | Call by reference | Type reference (TYPE) | RS_T_MSG | BW: Tabelle mit Nachrichten (Application Log Protokoll) | 20110128 | ||
2 | Importing | I_OBJFUNC | Call by reference | Type reference (TYPE) | RSOBJFUNC | Wie wird das Objekt aus dem Content übernommen | 20110412 | ||
3 | Importing | I_SIMULATE | Call by reference | Type reference (TYPE) | RS_BOOL | RS_C_FALSE | Simulationsmodus | 20110203 | |
4 | Importing | I_TRIGGER_TRANSPORT | Call by reference | Type reference (TYPE) | RS_BOOL | RS_C_FALSE | Transportobjekt schreiben | 20110512 |
Method ACTIVATE_DEPENDENT_OBJECTS on Interface IF_RSRTS_TRPR has no exception.
Method CHECK_AUTHORITY_ADMWB Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_ACTVT | Call by reference | Type reference (TYPE) | ACTIV_AUTH | 20110107 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_RS_NOT_AUTHORIZED | Keine Berechtigung (nicht als Vaterklasse benutzen !!) | 20110107 |
Method CHECK_METADATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_SUBRC | Call by reference | Type reference (TYPE) | SY-SUBRC | (Returncode > 0)= Fehler | 20110825 | ||
2 | Exporting | E_T_MSG | Call by reference | Type reference (TYPE) | RS_T_MSG | BW: Tabelle mit Nachrichten (Application Log Protokoll) | 20110825 |
Method CHECK_METADATA on Interface IF_RSRTS_TRPR has no exception.
Method FACTORY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_DONT_USE_BUFFER | Call by reference | Type reference (TYPE) | RS_BOOL | RS_C_FALSE | Boolean | 20110107 | |
2 | Importing | I_INFOPROV | Call by reference | Type reference (TYPE) | RSINFOPROV | InfoProvider | 20110107 | ||
3 | Importing | I_OBJECT | Call by reference | Type reference (TYPE) | CHAR24 | Characterfeld Länge 24 | 20110107 | ||
4 | Returning | R_R_REF | Value transfer | Object reference (TYPE REF TO) | IF_RSRTS_TRPR | TLOGO-Erweiterung für transiente InfoProvider | 20110107 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_RS_NOT_FOUND | Objekt nicht gefunden | 20110107 |
Method GET_DEPENDENT_OBJECTS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_TS_DEP_OBJECT | Call by reference | Type reference (TYPE) | NT_TS_OBJECT | 20110107 | |||
2 | Exporting | E_T_MSG | Call by reference | Type reference (TYPE) | RS_T_MSG | BW: Tabelle mit Nachrichten (Application Log Protokoll) | 20110107 | ||
3 | Importing | I_OBJVERS | Call by reference | Type reference (TYPE) | RSOBJVERS | Objektversion | 20110616 |
Method GET_DEPENDENT_OBJECTS on Interface IF_RSRTS_TRPR has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 731 |