SAP ABAP Interface IF_RSDME_PRED_TASK_RT_WHATIF (Prediction Task Runtime Interface - for WHATIF)
Hierarchy
☛
SAP_BW (Software Component) SAP Business Warehouse
⤷
BW-EI-DM (Application Component) Data Mining
⤷
RS_DME_IS (Package) Datamining - Intelligent Service - Adapters

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_RSDME_PRED_RT_WHAT_IF_ABS | What-If Prediction Class - Runtime | 20030804 |
Properties
Interface | IF_RSDME_PRED_TASK_RT_WHATIF | |
Short Description | Prediction Task Runtime Interface - for WHATIF |
General Data
Package | RS_DME_IS | Datamining - Intelligent Service - Adapters |
Created | 20030728 | SAP |
Last changed | 20110908 | SAP |
Unicode checks active |
Forward declarations
Interface IF_RSDME_PRED_TASK_RT_WHATIF has no forward declaration.
Interfaces
Interface IF_RSDME_PRED_TASK_RT_WHATIF has no interface.
Friends
Interface IF_RSDME_PRED_TASK_RT_WHATIF has no friend.
Attributes
Interface IF_RSDME_PRED_TASK_RT_WHATIF has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Check Value | 20030908 |
2 | ![]() |
Instance method | Public | Method | Execute What-If Analysis | 20030908 |
3 | ![]() |
Instance method | Public | Method | Get all outputs | 20030804 |
4 | ![]() |
Instance method | Public | Method | Get Prediction Output for specified field (default rank = 1) | 20030728 |
5 | ![]() |
Instance method | Public | Method | Set Engine | 20030915 |
6 | ![]() |
Instance method | Public | Method | Set Input data | 20030804 |
7 | ![]() |
Instance method | Public | Method | Set Model | 20030915 |
Events
Interface IF_RSDME_PRED_TASK_RT_WHATIF has no event.
Types
Interface IF_RSDME_PRED_TASK_RT_WHATIF has no local type.
Method Signatures
Method CHECK_VALUE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_T_RETURN | Value transfer | Type reference (TYPE) | BAPIRET2_T | 20030908 | |||
2 | ![]() |
I_FIELD | Call by reference | Type reference (TYPE) | RSDMEM_COLUMN_NAME | 20030908 | |||
3 | ![]() |
I_VALUE | Call by reference | Type reference (TYPE) | STRING | 20030908 |
Method CHECK_VALUE on Interface IF_RSDME_PRED_TASK_RT_WHATIF has no exception.
Method EXECUTE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_T_RETURN | Value transfer | Type reference (TYPE) | BAPIRET2_T | Protokolltabelle | 20030915 |
Method EXECUTE on Interface IF_RSDME_PRED_TASK_RT_WHATIF has no exception.
Method GET_OUTPUT_ALL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_T_PRED_OUTPUT | Value transfer | Type reference (TYPE) | RSDMSI_T_PRED_WHATIF_OUTPUT | Tabelle mit Ausgaben | 20030804 |
Method GET_OUTPUT_ALL on Interface IF_RSDME_PRED_TASK_RT_WHATIF has no exception.
Method GET_OUTPUT_VALUE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_VALUE | Value transfer | Type reference (TYPE) | ANY | Wert | 20030804 | ||
2 | ![]() |
E_VALUE_DESC | Value transfer | Type reference (TYPE) | RSDMEM_LANGU_DESCRIPTION | Wertbeschreibung | 20030919 | ||
3 | ![]() |
I_FIELD | Call by reference | Type reference (TYPE) | RSDMEM_PRED_FIELD | Feld für Vorhersageausgabe | 20030804 | ||
4 | ![]() |
I_RANK | Call by reference | Type reference (TYPE) | RSDMEI_RANK | 1 | Rang | 20030804 |
Method GET_OUTPUT_VALUE on Interface IF_RSDME_PRED_TASK_RT_WHATIF has no exception.
Method SET_ENGINE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_ENGINE | Call by reference | Type reference (TYPE) | RSDMEM_ANALYTICAL_SERVICE | 20030915 |
Method SET_ENGINE on Interface IF_RSDME_PRED_TASK_RT_WHATIF has no exception.
Method SET_INPUT_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_T_INPUT | Call by reference | Type reference (TYPE) | RSDMSI_T_PRED_WHATIF_INPUT | Eingabefeld-Werte-Paare | 20030804 |
Method SET_INPUT_DATA on Interface IF_RSDME_PRED_TASK_RT_WHATIF has no exception.
Method SET_MODEL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_MODEL | Call by reference | Type reference (TYPE) | RSDMEM_MODEL | 20030915 |
Method SET_MODEL on Interface IF_RSDME_PRED_TASK_RT_WHATIF has no exception.
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 350 |