SAP ABAP Interface IF_HRPA_STANDARD_CONVERSIONS (HRPAD Standard Interface MAC Conversion)
Hierarchy
☛
EA-HRCDE (Software Component) Sub component EA-HRCDE of EA-HR
⤷
PA-ESS-DE (Application Component) Germany
⤷
PAOC_FACE_ESS_DE (Package) Reports and PersInfo Scenarios for Germany

⤷

⤷

Properties
Interface | IF_HRPA_STANDARD_CONVERSIONS | |
Short Description | HRPAD Standard Interface MAC Conversion |
General Data
Package | PAOC_FACE_ESS_DE | Reports and PersInfo Scenarios for Germany |
Created | 20030617 | SAP |
Last changed | 20040315 | SAP |
Unicode checks active |
Forward declarations
Interface IF_HRPA_STANDARD_CONVERSIONS has no forward declaration.
Interfaces
Interface IF_HRPA_STANDARD_CONVERSIONS has no interface.
Friends
Interface IF_HRPA_STANDARD_CONVERSIONS has no friend.
Attributes
Interface IF_HRPA_STANDARD_CONVERSIONS has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Conversion of Screen Structure to Infotype Structure | 20030617 |
2 | ![]() |
Instance method | Public | Method | Conversion of Screen Structure to Infotype Repeat Structure | 20030617 |
3 | ![]() |
Instance method | Public | Method | Conversion of Infotype Structure to Screen Structure | 20030617 |
4 | ![]() |
Instance method | Public | Method | Conversion of Infotype Repeat Structure to Screen Structure | 20030617 |
Events
Interface IF_HRPA_STANDARD_CONVERSIONS has no event.
Types
Interface IF_HRPA_STANDARD_CONVERSIONS has no local type.
Method Signatures
Method INPUT_CONVERSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_OK | Call by reference | Type reference (TYPE) | BOOLE_D | Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') | 20030617 | ||
2 | ![]() |
MESSAGE_HANDLER | Call by reference | Object reference (TYPE REF TO) | IF_HRPA_MESSAGE_HANDLER | HR Master Data: Messages | 20030617 | ||
3 | ![]() |
PNNNN | Call by reference | Type reference (TYPE) | ANY | Primär-Infotypstruktur | 20030617 | ||
4 | ![]() |
PNNNN2 | Call by reference | Type reference (TYPE) | ANY | Sekundär-Infotypstruktur | 20030625 | ||
5 | ![]() |
PREF | Call by reference | Type reference (TYPE) | PREF | Zuordnungsgrößen für HR-Objekte | 20030702 | ||
6 | ![]() |
SCREEN_STRUCTURE | Call by reference | Type reference (TYPE) | ANY | Screen Struktur | 20030617 | ||
7 | ![]() |
SCREEN_STRUCTURE_NAME | Call by reference | Type reference (TYPE) | CRMT_BSP_SCRSTRUCNAME | Name der Screen Struktur | 20030617 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
HR: Stammdaten, unerfüllte Programmbedingung | 20030617 |
Method INPUT_TABLE_CONVERSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_OK | Call by reference | Type reference (TYPE) | BOOLE_D | Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') | 20030617 | ||
2 | ![]() |
MESSAGE_HANDLER | Call by reference | Object reference (TYPE REF TO) | IF_HRPA_MESSAGE_HANDLER | HR Master Data: Messages | 20030617 | ||
3 | ![]() |
PNNNN | Call by reference | Type reference (TYPE) | ANY | Primär-Infotypstruktur | 20030617 | ||
4 | ![]() |
PNNNN2 | Call by reference | Type reference (TYPE) | ANY | Sekundär-Infotypstruktur | 20030625 | ||
5 | ![]() |
SCREEN_STRUCTURE | Call by reference | Type reference (TYPE) | ANY | Screen Struktur | 20030617 | ||
6 | ![]() |
SCREEN_STRUCTURE_NAME | Call by reference | Type reference (TYPE) | CRMT_BSP_SCRSTRUCNAME | Name der Screen Struktur | 20030617 | ||
7 | ![]() |
TABNO | Call by reference | Type reference (TYPE) | HRTABSEQNR | Nummer des Repeatsatzes im Infotyp | 20030630 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
HR: Stammdaten, unerfüllte Programmbedingung | 20030617 |
Method OUTPUT_CONVERSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
FIELD_ATTRIBUTES | Call by reference | Type reference (TYPE) | CRMT_BSP_FIELDATTRIB_TAB | Feldeigenschaften | 20030717 | ||
2 | ![]() |
IS_OK | Call by reference | Type reference (TYPE) | BOOLE_D | Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') | 20030617 | ||
3 | ![]() |
MASSG | Call by reference | Type reference (TYPE) | MASSG | Maßnahmengrund | 20030724 | ||
4 | ![]() |
MASSN | Call by reference | Type reference (TYPE) | MASSN | Maßnahmenart | 20030724 | ||
5 | ![]() |
MESSAGE_HANDLER | Call by reference | Object reference (TYPE REF TO) | IF_HRPA_MESSAGE_HANDLER | HR Master Data: Messages | 20030617 | ||
6 | ![]() |
MODE | Call by reference | Type reference (TYPE) | HRPAD_CHAR20 | letzter Modus (MODIFY, INSERT, COPY, DELETE, space) | 20031002 | ||
7 | ![]() |
PNNNN | Call by reference | Type reference (TYPE) | ANY | Primär-Infotypstruktur | 20030617 | ||
8 | ![]() |
PNNNN2 | Call by reference | Type reference (TYPE) | ANY | Sekundär-Infotypstruktur | 20030625 | ||
9 | ![]() |
PREF | Call by reference | Type reference (TYPE) | PREF | Zuordnungsgrößen für HR-Objekte | 20030702 | ||
10 | ![]() |
SCREEN_STRUCTURE | Call by reference | Type reference (TYPE) | ANY | Screen- Struktur | 20030617 | ||
11 | ![]() |
SCREEN_STRUCTURE_NAME | Call by reference | Type reference (TYPE) | CRMT_BSP_SCRSTRUCNAME | Name der Screen- Struktur | 20030617 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
HR: Stammdaten, unerfüllte Programmbedingung | 20030630 |
Method OUTPUT_TABLE_CONVERSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
FIELD_ATTRIBUTES | Call by reference | Type reference (TYPE) | CRMT_BSP_FIELDATTRIB_TAB | Feldeigenschaften | 20030717 | ||
2 | ![]() |
IS_OK | Call by reference | Type reference (TYPE) | BOOLE_D | Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') | 20030617 | ||
3 | ![]() |
MASSG | Call by reference | Type reference (TYPE) | MASSG | Maßnahmengrund | 20030724 | ||
4 | ![]() |
MASSN | Call by reference | Type reference (TYPE) | MASSN | Maßnahmenart | 20030724 | ||
5 | ![]() |
MESSAGE_HANDLER | Call by reference | Object reference (TYPE REF TO) | IF_HRPA_MESSAGE_HANDLER | HR Master Data: Messages | 20030617 | ||
6 | ![]() |
MODE | Call by reference | Type reference (TYPE) | HRPAD_CHAR20 | letzter Modus (MODIFY, INSERT, COPY, DELETE, space) | 20031002 | ||
7 | ![]() |
PNNNN | Call by reference | Type reference (TYPE) | ANY | Primär-Infotypstruktur | 20030617 | ||
8 | ![]() |
PNNNN2 | Call by reference | Type reference (TYPE) | ANY | Sekundär--Infotypstruktur | 20030625 | ||
9 | ![]() |
SCREEN_STRUCTURES | Call by reference | Type reference (TYPE) | STANDARD TABLE | Tabelle zur Screenstruktur | 20030717 | ||
10 | ![]() |
SCREEN_STRUCTURE_NAME | Call by reference | Type reference (TYPE) | CRMT_BSP_SCRSTRUCNAME | Name der Screen Struktur | 20030617 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
HR: Stammdaten, unerfüllte Programmbedingung | 20030630 |
History
Last changed by/on | SAP | 20040315 |
SAP Release Created in | 100 |