SAP ABAP Interface IF_EX_OII_DIP_CALCULATION (BAdI interface IF_EX_OII_DIP_CALCULATION)
Hierarchy
☛
IS-OIL (Software Component) IS-OIL
⤷
IS-OIL-DS-BDR (Application Component) Bulk Distribution Requirements Planning
⤷
OII (Package) BDRP Bulk Distribution Requirement Planning
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_OII_DIP_CALCULATION | BAdI class CL_EX_OII_DIP_CALCULATION | 20000922 |
Properties
| Interface | IF_EX_OII_DIP_CALCULATION | |
| Short Description | BAdI interface IF_EX_OII_DIP_CALCULATION |
General Data
| Package | OII | BDRP Bulk Distribution Requirement Planning |
| Created | 20000922 | SAP |
| Last changed | 20050224 | SAP |
| Unicode checks active |
Forward declarations
Interface IF_EX_OII_DIP_CALCULATION has no forward declaration.
Interfaces
Interface IF_EX_OII_DIP_CALCULATION has no interface.
Friends
Interface IF_EX_OII_DIP_CALCULATION has no friend.
Attributes
Interface IF_EX_OII_DIP_CALCULATION has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Additional calculations for tank dips | 20001013 | |
| 2 | Instance method | Public | Method | Additional checks during change/deletion of tank dips | 20040511 | |
| 3 | Instance method | Public | Method | Air boyancy factor for floating roof correction | 20040301 | |
| 4 | Instance method | Public | Method | Special calculation for floating roof correction | 20030708 | |
| 5 | Instance method | Public | Method | Modify the tank dip calculation in OII_TANK_DIP_CALCULATOR | 20001013 | |
| 6 | Instance method | Public | Method | Additional calculations for tank dips | 20010125 |
Events
Interface IF_EX_OII_DIP_CALCULATION has no event.
Types
Interface IF_EX_OII_DIP_CALCULATION has no local type.
Method Signatures
Method ADDITIONAL_CALCULATION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_LINE_CHANGE | Call by reference | Type reference (TYPE) | CHAR1 | Kennzeichen für Zeilenänderung | 20001013 | |||
| 2 | I_ROIITANKDIP | Call by reference | Type reference (TYPE) | ROIITANKDIP | Tankpegel-Position | 20001013 |
Method ADDITIONAL_CALCULATION on Interface IF_EX_OII_DIP_CALCULATION has no exception.
Method ADDITIONAL_CHECKS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ROIITANKDIP | Call by reference | Type reference (TYPE) | TTROIITANKDIP | Anzeigestruktur für Tank-Volumenumrechnungs-Historie | 20040511 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Fehler während zusätzlichen Prüfungen von Kundenfeldern | 20040511 |
Method FLOATING_ROOF_AIRBUOYANCY_FACT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_PARAM | Call by reference | Type reference (TYPE) | OI_T_QCI_TAB | Tabellentyp für SMU-Parametertabelle (Schnittst. Mengenumr.) | 20040301 | |||
| 2 | MDICH_FLROOF | Call by reference | Type reference (TYPE) | OIB_A02-BDICH | Mineralöl/Erdgasdichte bei Standardbedingungen | 20040301 |
Method FLOATING_ROOF_AIRBUOYANCY_FACT on Interface IF_EX_OII_DIP_CALCULATION has no exception.
Method FLOATING_ROOF_CORRECTION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_PARAM | Value transfer | Type reference (TYPE) | OI_T_QCI_TAB | Tabellentyp für SMU-Parametertabelle (Schnittst. Mengenumr.) | 20030708 |
Method FLOATING_ROOF_CORRECTION on Interface IF_EX_OII_DIP_CALCULATION has no exception.
Method MODIFY_CALCULATION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ROIISLVCAL | Call by reference | Type reference (TYPE) | ROIISLVCAL | Zusätzliche Information | 20001013 | |||
| 2 | I_ROIISOCHK | Call by reference | Type reference (TYPE) | ROIISOCHK | Volumenumrechnungsdaten | 20001013 | |||
| 3 | I_SOCNR | Call by reference | Type reference (TYPE) | OIISOCK-SOCNR | Interne Tanknummer | 20001013 | |||
| 4 | I_TIMESTAMP | Call by reference | Type reference (TYPE) | OIISLVCH-VALFROM | Zeitstempel (Pegel) | 20001013 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Rechenfehler | 20001013 |
Method PREPARE_PARAMETERS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_LINE_CHANGE | Call by reference | Type reference (TYPE) | CHAR1 | Kennzeichen für Zeilenänderung | 20010125 | |||
| 2 | I_ROIITANKDIP | Call by reference | Type reference (TYPE) | ROIITANKDIP | Tankpegel-Position | 20010125 |
Method PREPARE_PARAMETERS on Interface IF_EX_OII_DIP_CALCULATION has no exception.
History
| Last changed by/on | SAP | 20050224 |
| SAP Release Created in |