SAP ABAP Interface IF_EX_OII_DIP_CALCULATION (BAdI interface IF_EX_OII_DIP_CALCULATION)
Hierarchy
☛
IS-OIL (Software Component) IS-OIL
⤷ IS-OIL-DS-BDR (Application Component) Bulk Distribution Requirements Planning
⤷ OII (Package) BDRP Bulk Distribution Requirement Planning
⤷ IS-OIL-DS-BDR (Application Component) Bulk Distribution Requirements Planning
⤷ OII (Package) BDRP Bulk Distribution Requirement Planning
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_OII_DIP_CALCULATION | BAdI class CL_EX_OII_DIP_CALCULATION | 20000922 |
Properties
Interface | IF_EX_OII_DIP_CALCULATION | |
Short Description | BAdI interface IF_EX_OII_DIP_CALCULATION |
General Data
Package | OII | BDRP Bulk Distribution Requirement Planning |
Created | 20000922 | SAP |
Last changed | 20050224 | SAP |
Unicode checks active |
Forward declarations
Interface IF_EX_OII_DIP_CALCULATION has no forward declaration.
Interfaces
Interface IF_EX_OII_DIP_CALCULATION has no interface.
Friends
Interface IF_EX_OII_DIP_CALCULATION has no friend.
Attributes
Interface IF_EX_OII_DIP_CALCULATION has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ADDITIONAL_CALCULATION | Instance method | Public | Method | Additional calculations for tank dips | 20001013 |
2 | ADDITIONAL_CHECKS | Instance method | Public | Method | Additional checks during change/deletion of tank dips | 20040511 |
3 | FLOATING_ROOF_AIRBUOYANCY_FACT | Instance method | Public | Method | Air boyancy factor for floating roof correction | 20040301 |
4 | FLOATING_ROOF_CORRECTION | Instance method | Public | Method | Special calculation for floating roof correction | 20030708 |
5 | MODIFY_CALCULATION | Instance method | Public | Method | Modify the tank dip calculation in OII_TANK_DIP_CALCULATOR | 20001013 |
6 | PREPARE_PARAMETERS | Instance method | Public | Method | Additional calculations for tank dips | 20010125 |
Events
Interface IF_EX_OII_DIP_CALCULATION has no event.
Types
Interface IF_EX_OII_DIP_CALCULATION has no local type.
Method Signatures
Method ADDITIONAL_CALCULATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | I_LINE_CHANGE | Call by reference | Type reference (TYPE) | CHAR1 | Kennzeichen für Zeilenänderung | 20001013 | ||
2 | Changing | I_ROIITANKDIP | Call by reference | Type reference (TYPE) | ROIITANKDIP | Tankpegel-Position | 20001013 |
Method ADDITIONAL_CALCULATION on Interface IF_EX_OII_DIP_CALCULATION has no exception.
Method ADDITIONAL_CHECKS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | I_ROIITANKDIP | Call by reference | Type reference (TYPE) | TTROIITANKDIP | Anzeigestruktur für Tank-Volumenumrechnungs-Historie | 20040511 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | SET_ERROR | Fehler während zusätzlichen Prüfungen von Kundenfeldern | 20040511 |
Method FLOATING_ROOF_AIRBUOYANCY_FACT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CT_PARAM | Call by reference | Type reference (TYPE) | OI_T_QCI_TAB | Tabellentyp für SMU-Parametertabelle (Schnittst. Mengenumr.) | 20040301 | ||
2 | Changing | MDICH_FLROOF | Call by reference | Type reference (TYPE) | OIB_A02-BDICH | Mineralöl/Erdgasdichte bei Standardbedingungen | 20040301 |
Method FLOATING_ROOF_AIRBUOYANCY_FACT on Interface IF_EX_OII_DIP_CALCULATION has no exception.
Method FLOATING_ROOF_CORRECTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CT_PARAM | Value transfer | Type reference (TYPE) | OI_T_QCI_TAB | Tabellentyp für SMU-Parametertabelle (Schnittst. Mengenumr.) | 20030708 |
Method FLOATING_ROOF_CORRECTION on Interface IF_EX_OII_DIP_CALCULATION has no exception.
Method MODIFY_CALCULATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_ROIISLVCAL | Call by reference | Type reference (TYPE) | ROIISLVCAL | Zusätzliche Information | 20001013 | ||
2 | Changing | I_ROIISOCHK | Call by reference | Type reference (TYPE) | ROIISOCHK | Volumenumrechnungsdaten | 20001013 | ||
3 | Importing | I_SOCNR | Call by reference | Type reference (TYPE) | OIISOCK-SOCNR | Interne Tanknummer | 20001013 | ||
4 | Importing | I_TIMESTAMP | Call by reference | Type reference (TYPE) | OIISLVCH-VALFROM | Zeitstempel (Pegel) | 20001013 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CALCULATION_ERROR | Rechenfehler | 20001013 |
Method PREPARE_PARAMETERS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | I_LINE_CHANGE | Call by reference | Type reference (TYPE) | CHAR1 | Kennzeichen für Zeilenänderung | 20010125 | ||
2 | Changing | I_ROIITANKDIP | Call by reference | Type reference (TYPE) | ROIITANKDIP | Tankpegel-Position | 20010125 |
Method PREPARE_PARAMETERS on Interface IF_EX_OII_DIP_CALCULATION has no exception.
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in |