SAP ABAP Interface IF_BSP_WD_COMPONENT_DESCRIPTOR (Component Description)
Hierarchy
☛
WEBCUIF (Software Component) SAP Web UI Framework
⤷ CA-WUI-UI-RT (Application Component) UI Runtime Environment
⤷ CRM_BSP_WD_CUST (Package) Customizing Objects for the WebClient UI Framework Runtime
⤷ CA-WUI-UI-RT (Application Component) UI Runtime Environment
⤷ CRM_BSP_WD_CUST (Package) Customizing Objects for the WebClient UI Framework Runtime
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_BSP_WD_COMPONENT_DESCRIPTOR | BSP WD Component Descriptor | 20060130 |
Properties
Interface | IF_BSP_WD_COMPONENT_DESCRIPTOR | |
Short Description | Component Description |
General Data
Package | CRM_BSP_WD_CUST | Customizing Objects for the WebClient UI Framework Runtime |
Created | 20060130 | SAP |
Last changed | 20100303 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ABAP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no interface.
Friends
Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no friend.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | COMPONENT_NAME | Instance attribute | Public | Type reference (TYPE) | BSP_WD_COMPONENT_NAME | Component Name | 20060823 | ||
2 | ENHANCEMENT_SET | Instance attribute | Public | Type reference (TYPE) | BSP_WD_ENHANCEMENT_SET | Enhancement Set | 20070913 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ADD_CONTROLLER_REPLACEMENT | Instance method | Public | Method | Delete a Substitute Controller (Persistent) | 20060830 |
2 | CHECK_ANY_CNTR_REPL_EXISTS | Instance method | Public | Method | Check Whether a Substitute Controller Is Defined | 20080721 |
3 | CHECK_IS_ADDITIONAL_CONTROLLER | Instance method | Public | Method | Check Whether Controller Is an Additional Controller | 20070907 |
4 | CHECK_IS_ENHANCED_COMPONENT | Instance method | Public | Method | Checks Whether the Component Was Enhanced | 20060823 |
5 | CHECK_IS_REPLACED | Instance method | Public | Method | Gets the Substitute Controller if Required | 20070907 |
6 | DELETE_CONTROLLER_REPLACEMENT | Instance method | Public | Method | Adds a Substitute Controller (Persistent) | 20070907 |
7 | GET_ADDITIONAL_CONTROLLERS | Instance method | Public | Method | Gets the Substitute Controller if Required | 20070907 |
8 | GET_BSP_APPL_OF_COMPONENT | Instance method | Public | Method | Returns BSP Application for a Component | 20060823 |
9 | GET_CONTROLLER_REPLACEMENT | Instance method | Public | Method | Gets the Substitute Controller if Required | 20060823 |
10 | GET_RUNTIME_REPOSITORY_SOURCE | Instance method | Public | Method | Gets the Source of the Runtime Repository | 20060823 |
Events
Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no event.
Types
Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no local type.
Method Signatures
Method ADD_CONTROLLER_REPLACEMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_CONTROLLER_NAME | Call by reference | Type reference (TYPE) | STRING | Name einer BSP-Seite/-Controller (in Groß-/Kleinschreibung) | 20060830 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_BSP_WD_ENHANCEMENT_ERROR | Fehler bei der Komponentenerweiterung | 20060908 |
Method CHECK_ANY_CNTR_REPL_EXISTS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RV_RESULT | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20080721 |
Method CHECK_ANY_CNTR_REPL_EXISTS on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
Method CHECK_IS_ADDITIONAL_CONTROLLER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_CONTROLLER | Call by reference | Type reference (TYPE) | STRING | 20070907 | |||
2 | Returning | RV_RESULT | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20070907 |
Method CHECK_IS_ADDITIONAL_CONTROLLER on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
Method CHECK_IS_ENHANCED_COMPONENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RV_RESULT | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20060823 |
Method CHECK_IS_ENHANCED_COMPONENT on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
Method CHECK_IS_REPLACED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_CONTROLLER | Call by reference | Type reference (TYPE) | STRING | Controller | 20070907 | ||
2 | Returning | RV_RESULT | Value transfer | Type reference (TYPE) | ABAP_BOOL | 'X'- is replaced , space-no replacement | 20070907 |
Method CHECK_IS_REPLACED on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
Method DELETE_CONTROLLER_REPLACEMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_CONTROLLER_NAME | Call by reference | Type reference (TYPE) | STRING | Name einer BSP-Seite/-Controller (in Groß-/Kleinschreibung) | 20070907 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_BSP_WD_ENHANCEMENT_ERROR | Fehler bei der Komponentenerweiterung | 20070907 |
Method GET_ADDITIONAL_CONTROLLERS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RT_ADDITIONAL_CONTROLLERS | Value transfer | Type reference (TYPE) | BSP_WD_CONTR_REPLACEMENT_T | Substitute Controller | 20070907 |
Method GET_ADDITIONAL_CONTROLLERS on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
Method GET_BSP_APPL_OF_COMPONENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RV_BSP_APPL | Value transfer | Type reference (TYPE) | O2APPLNAME | Name einer BSP-Applikation | 20060823 |
Method GET_BSP_APPL_OF_COMPONENT on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
Method GET_CONTROLLER_REPLACEMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_CONTROLLER | Call by reference | Type reference (TYPE) | STRING | Controller | 20060823 | ||
2 | Returning | RV_REPLACEMENT | Value transfer | Type reference (TYPE) | STRING | Ersatz-Controller | 20060823 |
Method GET_CONTROLLER_REPLACEMENT on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
Method GET_RUNTIME_REPOSITORY_SOURCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_BSP_APPLNAME | Call by reference | Type reference (TYPE) | O2APPLNAME | Name der BSP-Anwendung (BSP) | 20060823 | ||
2 | Exporting | EV_BSP_PAGENAME | Call by reference | Type reference (TYPE) | O2PAGEEXT | Name einer BSP Seite | 20060823 | ||
3 | Exporting | EV_HTTP_URL | Call by reference | Type reference (TYPE) | STRING | Uniform Resource Locator (HTTP) | 20060823 | ||
4 | Exporting | EV_TYPE | Call by reference | Type reference (TYPE) | STRING | Repository Quelltyp (BSP | HTTP) | 20060823 |
Method GET_RUNTIME_REPOSITORY_SOURCE on Interface IF_BSP_WD_COMPONENT_DESCRIPTOR has no exception.
History
Last changed by/on | SAP | 20100303 |
SAP Release Created in | 700 |