SAP ABAP Interface /XNFE/IF_BADI_GATE_MONITOR (Interface to BAdI: /XNFE/BADI_GATE_MONITOR)
Hierarchy
☛
SLL-NFE (Software Component) xNFE
⤷
SLL-NFE-MGM (Application Component) NF-e: Communication Management & Monitoring
⤷
/XNFE/APPB2B (Package) NF-e: Application Functions - Inbound
⤷
⤷
Properties
| Interface | /XNFE/IF_BADI_GATE_MONITOR | |
| Short Description | Interface to BAdI: /XNFE/BADI_GATE_MONITOR |
General Data
| Package | /XNFE/APPB2B | NF-e: Application Functions - Inbound |
| Created | 20130220 | SAP |
| Last changed | 20141107 | |
| Unicode checks active |
Forward declarations
Interface /XNFE/IF_BADI_GATE_MONITOR has no forward declaration.
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20130220 |
Friends
Interface /XNFE/IF_BADI_GATE_MONITOR has no friend.
Attributes
Interface /XNFE/IF_BADI_GATE_MONITOR has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Method for Determining Status and Text for a CT-e | 20130220 | |
| 2 | Instance method | Public | Method | Method for Determining the Overall Status Text | 20130221 | |
| 3 | Instance method | Public | Method | Method for Determining Status and Text for an NF-e | 20130221 |
Events
Interface /XNFE/IF_BADI_GATE_MONITOR has no event.
Types
Interface /XNFE/IF_BADI_GATE_MONITOR has no local type.
Method Signatures
Method CTE_GET_STATUS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_STATUS | Call by reference | Type reference (TYPE) | /XNFE/GATE_DFE_STATUS | Gate DF-e Status | 20130307 | |||
| 2 | EV_STATUS_TEXT | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS_TEXT | DF-e Statustext für Gate Monitor | 20130307 | |||
| 3 | IV_CTEID | Call by reference | Type reference (TYPE) | /XNFE/CTEID | CT-e: 44-stelliger Zugriffsschlüssel | 20130220 | |||
| 4 | IV_STATUS | Call by reference | Type reference (TYPE) | /XNFE/GATE_DFE_STATUS | Gate DF-e Status | 20130221 | |||
| 5 | IV_STATUS_CODE | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS | DF-e Status für Gate Monitor | 20130307 | |||
| 6 | IV_STATUS_TEXT | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS_TEXT | DF-e Statustext für Gate Monitor | 20130307 | |||
| 7 | IV_XML | Call by reference | Type reference (TYPE) | /XNFE/XMLSTRING | XML-String | 20130221 |
Method CTE_GET_STATUS on Interface /XNFE/IF_BADI_GATE_MONITOR has no exception.
Method GET_OVERALL_TEXT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_OVERALL_STATUS_TEXT | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS_TEXT | DF-e Statustext für Gate Monitor | 20130221 | |||
| 2 | IT_DFE_STATUS | Call by reference | Type reference (TYPE) | /XNFE/INDFE_STATUS_T | DF-e Status Tabellentyp für Gate Monitor | 20130221 | |||
| 3 | IV_OVERALL_STATUS | Call by reference | Type reference (TYPE) | /XNFE/GATE_DFE_STATUS | Gate DF-e Status | 20130221 | |||
| 4 | IV_OVERALL_STATUS_TEXT | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS_TEXT | DF-e Statustext für Gate Monitor | 20130221 |
Method GET_OVERALL_TEXT on Interface /XNFE/IF_BADI_GATE_MONITOR has no exception.
Method NFE_GET_STATUS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_STATUS | Call by reference | Type reference (TYPE) | /XNFE/GATE_DFE_STATUS | Gate DF-e Status | 20130307 | |||
| 2 | EV_STATUS_TEXT | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS_TEXT | DF-e Statustext für Gate Monitor | 20130307 | |||
| 3 | IV_NFEID | Call by reference | Type reference (TYPE) | /XNFE/ID | 44-stelliger Zugriffsschlüssel | 20130221 | |||
| 4 | IV_STATUS | Call by reference | Type reference (TYPE) | /XNFE/GATE_DFE_STATUS | Gate DF-e Status | 20130221 | |||
| 5 | IV_STATUS_CODE | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS | DF-e Status für Gate Monitor | 20130307 | |||
| 6 | IV_STATUS_TEXT | Call by reference | Type reference (TYPE) | /XNFE/DFE_STATUS_TEXT | DF-e Statustext für Gate Monitor | 20130307 | |||
| 7 | IV_XML | Call by reference | Type reference (TYPE) | /XNFE/XMLSTRING | XML-String | 20130221 |
Method NFE_GET_STATUS on Interface /XNFE/IF_BADI_GATE_MONITOR has no exception.
History
| Last changed by/on | SAP | 20141107 |
| SAP Release Created in | 900 |