SAP ABAP Interface /UI2/IF_WDR_CFG_REPO_HNDL (Repository interaction for a single object)
Hierarchy
☛
SAP_UI (Software Component) User Interface Technology
⤷
CA-UI2-INT-BE (Application Component) Backend Enablement
⤷
/UI2/WD_CONFIGURATION (Package) UI2: WD Configuration

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | /UI2/CL_WDR_CFG_REPO_HNDL | Repository interaction for a configuration or customizing ob | 20130313 |
Properties
Interface | /UI2/IF_WDR_CFG_REPO_HNDL | |
Short Description | Repository interaction for a single object |
General Data
Package | /UI2/WD_CONFIGURATION | UI2: WD Configuration |
Created | 20130313 | SAP |
Last changed | 20131127 | SAP |
Unicode checks active |
Forward declarations
Interface /UI2/IF_WDR_CFG_REPO_HNDL has no forward declaration.
Interfaces
Interface /UI2/IF_WDR_CFG_REPO_HNDL has no interface.
Friends
Interface /UI2/IF_WDR_CFG_REPO_HNDL has no friend.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | IS_WORKBENCH_OBJECT | Instance attribute | Public | Type reference (TYPE) | WDY_BOOLEAN | 20130313 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | 20130313 | |
2 | ![]() |
Instance method | Public | Method | 20130313 | |
3 | ![]() |
Instance method | Public | Method | 20130313 | |
4 | ![]() |
Instance method | Public | Method | 20130313 | |
5 | ![]() |
Instance method | Public | Method | 20130313 | |
6 | ![]() |
Instance method | Public | Method | 20130313 | |
7 | ![]() |
Instance method | Public | Method | 20130313 | |
8 | ![]() |
Instance method | Public | Method | 20130313 | |
9 | ![]() |
Instance method | Public | Method | 20130313 | |
10 | ![]() |
Instance method | Public | Method | 20130313 |
Events
Interface /UI2/IF_WDR_CFG_REPO_HNDL has no event.
Types
Interface /UI2/IF_WDR_CFG_REPO_HNDL has no local type.
Method Signatures
Method AFTER_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
DEVCLASS | Call by reference | Type reference (TYPE) | DEVCLASS | 20130313 | |||
2 | ![]() |
IS_WEBDYNPRO_ENV | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20130313 | |||
3 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 | |||
4 | ![]() |
OBJECT_NAME | Call by reference | Type reference (TYPE) | WDY_COMPONENT_NAME | 20130313 | |||
5 | ![]() |
TRANSPORT | Call by reference | Type reference (TYPE) | TRKORR | 20130313 |
Method AFTER_DELETE on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EXISTS | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20130313 | |||
2 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 |
Method DELETE on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method DEQUEUE_FOR_EDIT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 |
Method DEQUEUE_FOR_EDIT on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method ENQUEUE_FOR_EDIT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ENQUEUE_ERROR | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20130313 | |||
2 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 | |||
3 | ![]() |
LOCKING_USER | Call by reference | Type reference (TYPE) | SY-UNAME | 20130313 | |||
4 | ![]() |
MESSAGE | Call by reference | Type reference (TYPE) | /UI2/IF_WD_CFG_TOOL=>MESSAGE | 20130313 |
Method ENQUEUE_FOR_EDIT on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method GET_OBJECT_NAME Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EXISTS | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20130313 | |||
2 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 | |||
3 | ![]() |
OBJECT_NAME | Call by reference | Type reference (TYPE) | CSEQUENCE | 20130313 |
Method GET_OBJECT_NAME on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method GET_OBJTYPE_AS_MSGV Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
MSGV | Value transfer | Type reference (TYPE) | SYMSGV | 20130313 |
Method GET_OBJTYPE_AS_MSGV on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method HAS_CHANGE_PERMISSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
HAS_PERMISSION | Value transfer | Type reference (TYPE) | WDY_BOOLEAN | 20130313 | |||
2 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 |
Method HAS_CHANGE_PERMISSION on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method HAS_DISPLAY_PERMISSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
HAS_PERMISSION | Value transfer | Type reference (TYPE) | WDY_BOOLEAN | 20130313 | |||
2 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 |
Method HAS_DISPLAY_PERMISSION on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method IS_KEY_VALID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_VALID | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20130313 | |||
2 | ![]() |
KEY | Call by reference | Object reference (TYPE REF TO) | /UI2/CL_WDR_CFG_OBJ_KEY | 20130313 | |||
3 | ![]() |
MESSAGES | Call by reference | Type reference (TYPE) | /UI2/IF_WD_CFG_TOOL=>MESSAGES | 20130313 |
Method IS_KEY_VALID on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
Method PROVIDE_DATA_CONTAINER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
DATA_CONTAINER | Value transfer | Object reference (TYPE REF TO) | /UI2/IF_WDR_CFG_DATA_CONTAINER | 20130313 |
Method PROVIDE_DATA_CONTAINER on Interface /UI2/IF_WDR_CFG_REPO_HNDL has no exception.
History
Last changed by/on | SAP | 20131127 |
SAP Release Created in | 100 |