SAP ABAP IMG Activity SIMG_ISHMED_CAPDOCUH (Notes on Cardiac Catheter Documentation)
Hierarchy
IS-H (Software Component) SAP Healthcare
   IS-HMED (Application Component) Clinical System
     NMED_DS (Package) Departmental Solutions
IMG Activity
ID SIMG_ISHMED_CAPDOCUH Notes on Cardiac Catheter Documentation  
Transaction Code S_PRI_97000055   (empty) 
Created on 20061214    
Customizing Attributes SIMG_ISHMED_CAPDOCUH   Notes on Cardiac Catheter Documentation 
Customizing Activity    
Document
Document Class SIMG   Hypertext: Object Class - Class to which a document belongs.
Document Name SIMG_ISHMED_CAPDOCUH    

Use

Cardiac Catheter Log

Cardiac catheter log data is transferred into the findings.
For each service there can therefore be only one cardiac catheter log. In document category N8CA_HKP the 'Unique' indicator is therefore set and may not be removed in the correspondingly created customer document category!

  • Display Material Consumption
    In the "Diagnostic and Therapeutic Steps" table there are various alternative fields for the material consumed:
    - N8CAHKDSMA Simple combo box field
    or
    - N8CAMAT Field for a material code
                    During MM integration the material number
                    and if the material is defined as a service
                    the service code is entered here.
    - N8CAMATTXT Name of material
  • Overview of Procedure Progress
    Currently, two lists are offered, which contain an overview of the progress of the procedure. On the "General Data" tab page you can request an overview for each service, which displays all time-dependent data of the "Progress" and "Hemodynamics" tab pages.
    On the "Progress" tab page you can create a list of the chronological process of a procedure including comments and the administration of drugs.
    In order to display the diagnostic and theraprutic steps in the overview, the Grouping column must contain a column sequence. If a column should not be displayed, no entry is made.
    On the ALV grid you cannot change the layout, as the lists do not have homogeneous column structures.

Cardiac Catheter Findings

  • CC number in cardiac catheter findings
    The cardiac catheter number is automatically transferred from the suitable CC log (element list -> external data supply)
  • Evaluation in Cardiac Catheter Findings
    In document category definition the grouping for the Evaluation documentation element must contain the alias name of the field to be transferred from the cardiac catheter log. The document category must be entered in the grouping of the field for the CC number.
    With the help of this entry the provisional evaluation is then transferred from the suitable CC log (pushbutton).
  • Further Fields in Cardiac Catheter Findings with Data Transfer
    Automatic presetting from the CC log is stored in the document category for the following fields (element list->external data supply):
    Body Weight, Patient Height, Complications
  • Input Help Based on Simulated Combo Boxes (N2KA)
    The input help for the findings abbreviations is based in the entries in table N2KA. This means combo box entries are simulated here. The fields are simple documentation elements and can only be filled with values from the input help.
    The same applies to the following fields:
    Study Participation
    Bypass Type in Bypass Table
  • Entries for Presetting Interventions
    In order for the Interventions table to be filled from the diagnostic/therapeutic steps of the CC log, the following prerequisites must be satisfied:
    • In document category definition the document category of the cardiac catheter log is entered in the groupin gfor the CC number documentation element.
    • In the short text of the combo box entry for a diagnostic or therapeutic step in the CC log the code 'CORO' is entered for a coronary intervention or 'OTHER' for another intervention.
    • The entered segment corresponds, in syntax, exactly to the name on the Coronary Angiography tab page, so that Stenosis pre can be preset from diagnostics.
  • Print Cardiac Catheter Findings with Smart Forms
    Five Smart Form sample forms have been provided, which are processed, one after the other in the Print Output user exit:
    N8CAHKB_1 Basic CC findings form (always print)
    N8CAHKB_2 Coronary angiography (only if executed)
    N8CAHKB_3 Interventions (only if executed)
    N8CAHKB_4 Ventriculography (only if executed)
    N8CAHKB_5 Vitien forms (only if executed)
    If you wish to use these samples, they should be copied into the customer namespace and the new names entered in the user exit.
    As a rule you will probably wish to make changes to at least Smart Form N8CAHKB_1.

    The forms have the include RN2DSCA_HKB_FORM with form routine and RN2DSCA_HKB_TYPES, which do not usually need to be copied.

Requirements

Standard settings

Activities

Example

Business Attributes
ASAP Roadmap ID 899   not to be assigned 
Mandatory / Optional 3   Nonrequired activity 
Critical / Non-Critical 2   Non-critical 
Country-Dependency A   Valid for all countries 
Assigned Application Components
Documentation Object Class Documentation Object Name Current line number Application Component Application Component Name
SIMG SIMG_ISHMED_CAPDOCUH 0 I010004300 Clinical System 
Maintenance Objects
Maintenance object type    
History
Last changed by/on SAP  20070103 
SAP Release Created in 700