Hierarchy
⤷ IS-HMED (Application Component) Clinical System
⤷ NMED_DS (Package) Departmental Solutions
IMG Activity
ID | SIMG_ISHMED_CACORDCD | Description of Cardiological CORD Components |
Transaction Code | S_PRI_97000063 | (empty) |
Created on | 20061215 | |
Customizing Attributes | SIMG_ISHMED_CACORDCD | Description of Cardiological CORD Components |
Customizing Activity |
Document
Document Class | SIMG | Hypertext: Object Class - Class to which a document belongs. |
Document Name | SIMG_ISHMED_CACORDCD |
Use
Cardiological components are provided for the clinical order. These can be integrated during the maintenance of the order type.
General Cardiology Header Component
Component name: SAP_CARDIOLOGY
A prerequisite for the component is that the "General Medical Data" header component is also integrated.
You can use the Prefindings pushbutton to call a dialog in order to transfer an individual field or a long text into the Short Anamnesis long text, from a PMD which has been specifically assigned to the order type as a prefinding (generator version 1 or 2 ).
The All Documents pushbutton returns a document viewer, in which all documents of the patient are offered. Filtering and / or sorting can be resolved using an administrator display variant.
Proposal texts for the Other Cardiovascular Risks field can be stored as combo box values (TA N2KA) for the documentation element N8CACAVSON.
Cardiac Catheter Item Component
Component name: SAP_CARD_HCAT
Proposal texts for the Other Info 1 and 2 fields can be stored for the element N8CACORDS1.
Proposal texts for the Procedure field in the table for previous interventions can be stored for the element N8CAINTER.
ECG Item Component
Component name: SAP_CARD_ECG
Proposal texts for the Other Rel. Medication field can be stored for the element N8CAMEDSON.
Proposal texts for the Pacemaker Type field can be stored for the element N8CA_PMTY.
Proposal texts for the ICD Type field can be stored for the element N8CA_ICDTY.
Special functions using additional programming:
When you create a new order, the fields of the component can be preset, for example, from existing orders. The PREALLOC method of the BAdI N1_CORDER_PREALLOC must be implemented for such presetting.
Required entry fields of the item component can be directly determined using the transaction N1COT on the Screen Modification tab page. A check is only made if the component is visible (e.g. tab page selected).
Required fields for header components can only be determine in this way from ERP2005 onwards. Using the functions of IS-H screen modification it is possible to achieve a fixed definition of some fields as required entry fields. A dynamic check must be implemented in BAdI N1_CORDER_CHECK.
The form N8CA_CORDER_DETAILS (Smart Form) has been provided for printing cardiological data within the framework of the printing of clinical order details. In this form the name of the integrated cardiological component is determined and the printout of corresponding content is realized. The name of the form must be overridden in BAdI N1_CORDER_PRINT_SSF. The method MODIFY_DATA is implemented for this.
The function module ISH_N2_DS_SHOW_CORD_DATA has been provided for the implementation of a quick view of the clinical order. The ID of the order must be transferred.
The clinical order is displayed via XML as a HTML view.
As standard the stylesheet 'ISH_CORDER_STANDARD' is used.
In customizing you can use system parameter N1COSTYL to name your own stylesheet.
If this function should be integrated into a PMD (with service reference), the user exit Z_DO_SHOW_CORDER (from the supplied include RN2DSCA_PMD_COMMON_UE) can be started using a pushbutton.
Requirements
Standard settings
Activities
Example
Business Attributes
ASAP Roadmap ID | 899 | not to be assigned |
Mandatory / Optional | 3 | Nonrequired activity |
Critical / Non-Critical | 2 | Non-critical |
Country-Dependency | A | Valid for all countries |
Assigned Application Components
Documentation Object Class | Documentation Object Name | Current line number | Application Component | Application Component Name |
---|---|---|---|---|
SIMG | SIMG_ISHMED_CACORDCD | 0 | I010004300 | Clinical System |
Maintenance Objects
Maintenance object type |
History
Last changed by/on | SAP | 20070103 |
SAP Release Created in | 700 |