SAP ABAP Class IWCI_WDR_P13N (Web Dynpro Interface COMPONENTCONTROLLER)
Properties
Class IWCI_WDR_P13N  
Short Description Web Dynpro Interface COMPONENTCONTROLLER    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 80  Web Dynpro Runtime Object 
Package      
Created 20040825   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class IWCI_WDR_P13N has no forward declaration.
Interfaces
Class IWCI_WDR_P13N has no interface implemented.
Friends
Class IWCI_WDR_P13N has no friend class.
Attributes
Class IWCI_WDR_P13N has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 INIT_P13N Instance method Public Method 20041209
2 RESET Instance method Public Method 20041207
3 SET_P13N_RT Instance method Public Method 20050519
4 SET_SIM_VIEW_ELEMENT_CONTROL Instance method Public Method 20050408
5 SIMULATES_VIEW_ELEMENT Instance method Public Method 20050224
6 WD_GET_API Instance method Public Method 20040825
Events
Class IWCI_WDR_P13N has no event.
Types
Class IWCI_WDR_P13N has no local type.
Method Signatures

Method INIT_P13N Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ONLY_THIS_ELEMENT Call by reference Type reference (TYPE) WDY_BOOLEAN 20041209
2 Importing I_VIEW_CONTROLLER Call by reference Object reference (TYPE REF TO) IF_WD_VIEW_CONTROLLER 20041209
3 Importing I_VIEW_ELEMENT_ID Call by reference Type reference (TYPE) STRING 20041209
4 Importing I_WINDOW Call by reference Object reference (TYPE REF TO) IF_WD_WINDOW 20041209

Method INIT_P13N on class IWCI_WDR_P13N has no exception.

Method RESET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_RESET_SCOPE Call by reference Type reference (TYPE) WDR_PERS_EXCEPTION 20041216

Method RESET on class IWCI_WDR_P13N has no exception.

Method SET_P13N_RT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_P13N_RT Call by reference Object reference (TYPE REF TO) CL_WDR_P13N_RT 20050519

Method SET_P13N_RT on class IWCI_WDR_P13N has no exception.

Method SET_SIM_VIEW_ELEMENT_CONTROL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_SIM_VIEW_ELEMENT Call by reference Object reference (TYPE REF TO) IWCI_IWD_SIMULATE_VIEW_ELEMENT 20050408

Method SET_SIM_VIEW_ELEMENT_CONTROL on class IWCI_WDR_P13N has no exception.

Method SIMULATES_VIEW_ELEMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_CUR_VIEW_ELEMENT Call by reference Object reference (TYPE REF TO) CL_WDR_VIEW_ELEMENT 20050915
2 Returning R_P13N_PARAM Value transfer Object reference (TYPE REF TO) CL_WD_P13N_PARAM 20050224

Method SIMULATES_VIEW_ELEMENT on class IWCI_WDR_P13N has no exception.

Method WD_GET_API Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RESULT Value transfer Object reference (TYPE REF TO) IF_WD_CONTROLLER 20040825

Method WD_GET_API on class IWCI_WDR_P13N has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in